Search NASA⌕ Search

SEARCH · Search NASA

Results for “Scintillation detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Terrestrial Gamma-ray Flash (TGF) Observations with the Gamma-ray Burst Monitor on the Fermi Observatory

Terrestrial Gamma-ray Flashes (TGFs) have now been detected with four different orbiting spacecraft. The latest observations are being made with the scintillation detectors of Gamma-ray Burst Monitor (GBM) on the Fermi Gamma-ray Space Telescope Observatory (Fermi). Although this experiment was designed and optimized for the observation of cosmic gamma-ray bursts (GRBs), it has unprecedented capabilities for TGF observations, surpassing those of the experiment that discovered TGFs, the BATSE experiment on the Compton Gamma-ray Observatory. Launched in June 2008 from the Kennedy Space Center, the Fermi-GBM has been detecting about one TGF every four weeks. The thick bismuth germinate (BGO) scintillation detectors of the GBM have now observed photon energies from TGFs at energies up to approx.40 MeV. Individual photons are detected with an absolute timing accuracy of 2 microsec. Unlike the BATSE instrument, the GBM data system allows higher counting rates to be recorded and deadtime characteristics are well-known and correctable; thus the saturation effects seen with BATSE are avoided. TGF pulses as narrow as approx.0.1ms have been observed with the GBM. Like BATSE (and unlike RHESSI) an on-board trigger is required to detect TGFs. The minimum time window for this trigger is 16ms. A trigger window this wide greatly reduces the number of detected TGFs, since they most often have a much shorter duration than this window, thus reducing the signal-to-background. New on-board trigger algorithms based on detected photon energies are about to be implemented; this should increase the number of TGF triggers. High-energy spectra from TGFs observed with Fermi-GBM will be described.

Fishman, Gerald J.↗

Proportional counter for X-ray analysis of lunar and planetary surfaces

A position sensitive proportional scintillation detector was developed and evaluated for use in applications involving X-ray imaging as well as spectroscopy. Topics covered include limitations of the proportional scintillation counter for use in space; purification of the xenon gas in the detector, and the operation of the detector system. Results show that the light signal in a proportional scintillation detector remains well localized. With modest electric fields in xenon, the primary electrons from a photoelectric absorption of an X-ray can be brought a distance of a few millimeters to a higher field region without spreading more than a millimeter or so. Therefore, it is possible to make a proportional scintillation detector with good position sensitivity that could be used to calibrate out the difference in light collection over its sensitive volume.

Source record↗

DUAL-PARTICLE DOSEMETER BASED ON ORGANIC SCINTILLATOR

Abstract Traditionally available handheld dosemeters are generally sensitive to only one type of radiation: neutrons or photons. Some dosemeters also rely on very specific attenuation correlations between response and dose, are not scalable in size and multiple dosemeters are required to characterise mixed-particle fields. The research presented here serves as a proof-of-concept for a method to simultaneously measure dose rates from neutrons and photons using a particle discriminating organic scintillation detector without the need for spectral deconvolution. The method was compared with traditional instruments and to simulation. Isotopic photon dose rates measured with this method were within 4% of simulated truth, whereas fission spectrum neutron dose rates were measured within 21%. Measurements of dose rates from both particles agree with simulated truth better than traditional instruments. This new method allows for measurement of dose equivalent from both neutrons and photons with a single instrument and no reliance on spectral deconvolution.

Miller, C. A.↗

Nuclear Science Symposium, 30th, and Symposium on Nuclear Power Systems, 15th, San Francisco, CA, October 19-21, 1983, Proceedings

The range of disciplines covered includes physics instrumentation, data acquisition, FASTBUS, radiation detectors, scintillators, photomultipliers and optical detectors, subnanosecond 2-D imaging, medical and health instrumentation, reactor instrumentation, and space instrumentation. Cerenkov detectors, the prevention and rate capability of breakdown processes in wire chambers, and an interactive parallel processor for data analysis are studied. Attention is also given to bismuth germanate's role in gamma-ray spectroscopy, and the construction of a broadband universal sampling head is described. Gamma-ray imaging with a rotating hexagonal uniform redundant array, and broadband X-ray astronomical spectrometry are considered.

Nakamura, M.↗

Silicon Photomultipliers Coupled to Scintillators With the Emission Maximum at 550 nm

A majority of the silicon photomultipliers (SiPMs) are sensitive to blue and near-ultraviolet (NUV) photons that are not optimized for scintillators with the emission maximum at wavelengths longer than 500 nm. The red–green–blue (RGB) SiPM is developed for the maximum photon detection efficiency (PDE) at 550 nm, which is a good match for some high-light-yield scintillators, such as CsI:Tl (CsI) and Gd 1.5 Y 1.5 Ga 2 Al 3 O 12 :Ce (GYGAG). Comparisons are made for the performance of these scintillators coupled to the RGB SiPM and a blue-sensitive SiPM. Because it takes tens of nanoseconds for the microcells to recharge after registering a photon hit, the linearity of these scintillation detectors was studied for high-energy gammas where numerous scintillation photons are generated. In addition, the energy resolution of the 662-keV gamma emitted by 137 Cs was measured for temperatures between –20 °C and 50 °C. The nonlinearity was observed above 1 MeV for all measurements, and however, it can be corrected by energy calibration using a third-degree polynomial. For CsI, the energy resolution is better with the blue-sensitive SiPM because of the lower dark count rate (DCR). In contrast, GYGAG coupled to the RGB SiPM has a better energy resolution for temperatures below 30 °C because of the well-matched emission spectrum and PDE distribution. Nevertheless, the advantage disappears for temperatures above 30 °C due to the higher DCR. It would be useful to further develop the RGB SiPM with a lower DCR and higher operating temperatures.

42 ENGINEERING↗

Analysis of 83m Kr prompt scintillation signals in the PIXeY detector

Prompt scintillation signals from 83m Kr calibration sources are a useful metric to calibrate the spatial variation of light collection efficiency and electric field magnitude of a two phase liquid-gas xenon time projection chamber. Because 83m Kr decays in two steps, there are two prompt scintillation pulses for each calibration event, denoted S1a and S1b. We study the ratio of S1b to S1a signal sizes in the Particle Identification in Xenon at Yale (PIXeY) experiment and its dependence on the time separation between the two signals (Δ t), notably its increase at low Δ t. Finally, in PIXeY data, the Δ t dependence of S1b/S1a is observed to exhibit two exponential components: one with a time constant of 0.05 ± 0.02 μ s, which can be attributed to processing effects and pulse overlap and one with a time constant of 10.2 ± 2.2 μs that increases in amplitude with electric drift field, the origin of which is not yet understood.

47 OTHER INSTRUMENTATION↗

A 4 x 4 SiPM Sensor Array with Fast Preamplified Output Engineered for the PWO Detectors of the EIC EEEMCAL

The PbWO4 scintillation detectors for the Electron-Ion Collider Electron Endcap Electromagnetic Calorimeter (EEEMCAL) cannot use vacuum photomultipler tubes due to the high magnetic field environment. We are presenting a readout solution with a 4 x 4 SiPM array directly coupled to a preamplification and summing stage. A second amplification stage with variable gain and offset adjustments is also included in the compact electronics module. The integrated power supply feeds the signal processing chain and the adjustable bias control. The parameter settings are saved locally on a EEPROM and are adjustable via the integrated communication interface through USB or RS485. The design was optimized to maximize signal collection energy resolution, for fast timing and wide dynamic range while keeping a small footprint with low power consumption and heat dissipation. The output response is fast enough to meet the 100 ? 200 ns digitization gate requirements for the detector. The electronics assembly requires no active cooling and includes a temperature sensor and a gain compensation of thermal variations which are important features for stable operation in large scale detector structures. A detector prototype was constructed with 20 mm x 20 mm x 200 mm PWO crystals affixed with individual SiPM array readouts and arranged in a 3 x 3 array. This detector was tested at the Thomas Jefferson National Accelerator Facility with 5GeV positrons. We will present the results of these detector characterization measurements.

Philip, O.↗

Characterization of Scintillating Crystal for High Energy Radiation Detection and Applications

Cesium Hafnium Chloride (Cs2Hfl6) is a promising metal halide scintillating detector due to its excellent characteristics such as non-hygroscopicity, high light yield without doping. Scintillators plays an important role in nuclear security applications as detectors at border monitoring stations. We grew and characterized CHC crystals to be fabricated for gamma detection. Photoluminescence was performed using the Duetta Fluorescence and Absorbance Spectrometer. The energy response to Cs-137 and Co-60 reference sources was recorded for a representative sodium iodide (NaI) scintillating detector.

Reeder, Angel↗

An Artificial Neural Network System for Photon-Based Active Interrogation Applications

Active interrogation (AI) is a promising technique to detect shielded special nuclear materials (SNMs). At the University of Michigan, we are developing a photon-based AI system that uses bremsstrahlung radiation from an electron linear accelerator (linac) as an ionizing source and stilbene organic scintillating detectors for neutron detection. Stilbene scintillators are sensitive to fast neutrons and photons and have excellent pulse shape discrimination (PSD) capabilities. The traditional charge integration (CI) method commonly used for PSD analysis eliminates piled-up pulses and relies on a particle discrimination line to separate neutrons and photons. The presence of the intense photon flux during AI creates a significant number of piled-up events in the stilbene scintillator, thereby posing a great challenge to the traditional CI method. Identifying true single neutron pulses becomes challenging due to the presence of a pile-up cloud and overlapping neutron, photon and pile-up clouds in the PSD analysis. To mitigate the effect of pulse pile up and identify true single neutron pulses from stilbene scintillators, an artificial neural network (ANN) system is developed. The developed ANN system identifies single neutron pulses and neutron-photon combinations from piled-up events. The results obtained from a 252Cf measurement in the presence of the intense photon flux show that the developed ANN system outperforms the traditional CI method. Since many piled-up events lie above the particle discrimination line, they get misclassified as neutrons by the traditional CI method resulting in 25% overestimation of the net neutron count rate during the linac pulse. The overall net neutron count rate (single and restored neutrons) during the linac pulse, estimated by the ANN system is 60% of the ground truth. Energy spectroscopy of the ANN attributed single neutron pulses further provides evidence on the detection of prompt fission neutrons from the 252Cf fission source.

42 ENGINEERING↗

Advances in solar and cosmic X-ray astronomy - A survey of experimental techniques and observational results.

The current status of X-ray astronomy is surveyed by reviewing observational results and theoretical conclusions gained within the past two years in areas dealing with the quiet-sun, slowly-varying, and burst components of solar X-radiation and with the features of cosmic X-ray sources. Thermal and nonthermal processes responsible for a wide variety of X-ray emission mechanisms in nature are explained, and characteristics of X radiation from specific solar structures are described. Attention is given to the effects of interstellar and intergalactic matter on cosmic X-rays; the properties of galactic and extragalactic X-ray sources; and the specifications of such instruments as gas-filled ionization detectors, proportional counters, Geiger counters, scintillation detectors, photoelectric detectors, polarimeters, collimators, spectrometers, and imaging systems.

Hoover, R. B.↗

Auger@TA: In-situ Cross-Calibration of the World's Largest Cosmic Ray Observatories

The Pierre Auger Observatory (Auger) and the Telescope Array (TA) are the world's two largest ultra-high-energy cosmic ray (UHECR) observatories. They operate in the Southern and Northern hemispheres, respectively, at similar latitudes but with distinct surface detector (SD) designs. A significant challenge in studying UHECR physics across the full sky is the apparent discrepancy in flux measurements between the two experiments. This discrepancy could arise from astrophysical differences and/or systematic effects related to their detector designs and sensitivities to extensive air shower components. To address this, the Auger@TA working group aims to cross-calibrate the two observatories with a self-triggering micro-Auger array within the TA array. This micro-array consists of eight Auger Surface Detector (SD) stations equipped with Water Cherenkov Detectors (WCDs) and AugerPrime Surface Scintillator Detectors. Seven SD stations, configured with a centered-1-PMT design, are arranged in a hexagonal pattern with one station in the center, with 1.5 km spacing, mirroring the Auger layout. The eighth station, which features a standard 3-PMT Auger station, is located in conjunction with a TA detector at the center of the hexagon, forming a triplet for high-statistics and low-uncertainty cross-calibration. A custom communication system that uses readily available components enables seamless communication between stations and remote access to each station through a central computer. The micro-array is now fully deployed, and initial data-taking is about to start. This presentation will detail the instrumentation, communication systems, central data acquisition system, expected performance of the micro-array, and preliminary results as appropriate.

Mocellin, Adriel G.B. [Colorado School of Mines]↗

Detector research

Pulse shape discrimination circuitry for dual crystal scintillation detector - Compton reduction

SCINTILLATION↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Scintillator-based Timepix3 detector for neutron spin-echo techniques using intensity modulation

A scintillator-based Timepix3 (TPX3) detector was developed to resolve the high-frequency modulation of a neutron beam in both spatial and temporal domains, as required for neutron spin-echo experiments. In this system, light from a scintillator is manipulated with an optical lens and is intensified using an image intensifier, making it detectable with the TPX3 chip. Two different scintillators, namely, 6 LiF:ZnS(Ag) and 6 LiI:Eu, were investigated to achieve the high resolution needed for spin-echo modulated small-angle neutron scattering (SEMSANS) and modulation of intensity with zero effort (MIEZE). The methodology for conducting event-mode analysis is described, including the optimization of clustering parameters for both scintillators. The detector with both scintillators was characterized with respect to detection efficiency, spatial resolution, count rate, uniformity, and γ-sensitivity. The 6 LiF:ZnS(Ag) scintillator-based detector achieved a spatial resolution of 200 μm and a count rate capability of 1.1 × 10 5 cps, while the 6 LiI:Eu scintillator-based detector demonstrated a spatial resolution of 250 μm and a count rate capability exceeding 2.9 × 10 5 cps. Furthermore, high-frequency intensity modulations in both spatial and temporal domains were successfully observed, confirming the suitability of this detector for SEMSANS and MIEZE techniques, respectively.

47 OTHER INSTRUMENTATION↗

Comparing Thermal Neutron Scintillators for Use With SiPM-Readout Detectors

Scintillator-based thermal neutron detectors for scientific scattering facilities offer an effective combination of large-area coverage and good spatial resolution. At Oak Ridge National Laboratory, silicon photomultiplier (SiPM)-readout Anger cameras using 6 Li glass scintillators have been developed, but the spatial resolution of these detectors is limited by the relatively low light yield of the glass. Recently, several brighter scintillator compositions with sufficient 6 Li concentration have emerged as promising candidates for higher-resolution imaging. Here, in this work, we evaluate five scintillator materials: GS20, LiF/ZnS:Ag, LiF/ZnO:Zn, LiI:Eu, and Cs 2 LiYCl 6 :Ce, each mounted on a SiPM Anger camera. For each scintillator, the neutron detection efficiency, spatial resolution, and count rate capabilities were measured and compared. Each of the new compositions achieved a spatial resolution better than 0.5 mm, compared to 0.66 mm for GS20, with LiI:Eu reaching the best value of 0.32 mm. Although these compositions improve the spatial resolution of the Anger camera, their longer pulse decay times limit their use in high count rate applications, and the camera’s hardware must be optimized for the different properties of the new scintillators.

Neutron detectors↗