Transparent sound screens

Transparent sound screens consisting of glass (organic glass) plates placed at fixed angles with respect to the floor are considered. Noise levels in the screened area depend on the cumulative effect of direct, reverberated and refracted components of sound energy radiated by the source. This effect is analyzed on the analogy of the summation of electrical impedances. Inasmuch as under given circumstances sufficient noise control can be obtained, transparent screens seem to solve the problem of unimpeded supervision of installations in noisy workshops and power plants; in administrative buildings, computing centers, design bureaus, etc., they ensure acoustic comfort without space losses and without inspiring claustrophobia.

Bizo, F.↗

Accelerated test techniques for micro-circuits: Evaluation of high temperature (473 k - 573 K) accelerated life test techniques as effective microcircuit screening methods

The application of high temperature accelerated test techniques was shown to be an effective method of microcircuit defect screening. Comprehensive microcircuit evaluations and a series of high temperature (473 K to 573 K) life tests demonstrated that a freak or early failure population of surface contaminated devices could be completely screened in thirty two hours of test at an ambient temperature of 523 K. Equivalent screening at 398 K, as prescribed by current Military and NASA specifications, would have required in excess of 1,500 hours of test. All testing was accomplished with a Texas Instruments' 54L10, low power triple-3 input NAND gate manufactured with a titanium- tungsten (Ti-W), Gold (Au) metallization system. A number of design and/or manufacturing anomalies were also noted with the Ti-W, Au metallization system. Further study of the exact nature and cause(s) of these anomalies is recommended prior to the use of microcircuits with Ti-W, Au metallization in long life/high reliability applications. Photomicrographs of tested circuits are included.

Johnson, G. M.↗

Irradiate-anneal screening of total dose effects in semiconductor devices

An extensive investigation of irradiate-anneal (IRAN) screening against total dose radiation effects was carried out as part of a program to harden the Mariner Jupiter/Saturn 1977 (MJS'77) spacecraft to survive the Jupiter radiation belts. The method consists of irradiating semiconductor devices with Cobalt-60 to a suitable total dose under representative bias conditions and of separating the parts in the undesired tail of the distribution from the bulk of the parts by means of a predetermined acceptance limit. The acceptable devices are then restored close to their preirradiation condition by annealing them at an elevated temperature. IRAN was used when lot screen methods were impracticable due to lack of time, and when members of a lot showed a diversity of radiation response. The feasibility of the technique was determined by testing of a number of types of linear bipolar integrated circuits, analog switches, n-channel JFETS and bipolar transistors. Based on the results of these experiments a number of device types were selected for IRAN of flight parts in the MJS'77 spacecraft systems. The part types, screening doses, acceptance criteria, number of parts tested and rejected as well as the program steps are detailed.

Stanley, A. G.↗

Direct measurement of the plasma screening length and surface potential near the lunar terminator

Direct measurement of the lunar dayside surface potential and screening length has been made by the suprathermal ion detector experiment (Side) near the terminator. In a region 20-30 deg from the terminator at the Apollo 14 and 15 sites the surface potential is found to be approximately 50 V negative, and the screening length to be about 1 km. This value of the screening length is more than 2 orders of magnitude greater than the solar wind 'Debye' length. The strong negative surface potential in this region may be due to enhanced temperature and density of the solar wind plasma.

Benson, J.↗

Simultaneous image reproduction on CRT screen: Moves ultrasonic sectional view and electrocardiogram curves

A method for simultaneous reproduction of images, requiring different amounts of time to reproduce, on a cathode ray tube (CRT) screen is disclosed. Ultrasonic sectional views and electrocardiogram curves are simultaneously reproduced on the CRT screen by producing the images on different areas of a screen with two phosphors having different persistence times and luminous colors, within the times required for the appearance of the images. In front of the area on which is produced the image requiring the shorter time is a color filter which is permeable to the color of the phosphor with the shorter persistence time by which absorbs the color of the other phosphor.

Source record↗

System and method for obtaining wide screen Schlieren photographs

A system for use in Schlieren photography includes (1) a viewing screen adjacently related to a large grating; (2) a small grating disposed in spaced relation with the large grating; (3) a transparent retainer for confining a transparent medium between the gratings; and (4) optics for imaging the small grating on the large grating. A light source and optically aligned lens are used to project a beam of light along axes extending through the small grating and strike the large grating, subsequent to passing through the medium. A Schlieren image of striations resulting from distortions of light rays proposed by the medium are formed on the screen. A camera is used to photograph the Schlieren image projected on the large screen.

Parthasarathy, S. P.↗

Intagliated phosphor screen image tube project

The production and evaluation of a magnetic focus image tube for astronomical photography that has an intagliated phosphor screen is described. The modulation transfer function of such a tube was measured by electronic means and by film tests, and the results compared with tubes of more conventional construction. The physical properties of the image tube and film combination, the analytical model of the optical interface, and the salient features of the intagliated screen tube are described. The results of electronic MTF tests of the intagliated image tube and of the densitometry of the tube and film test samples are presented. It is concluded that the intagliated screen is a help, but that the thickness of the photographic film is also important.

Hertzel, R. J.↗

Ocular screening tests of elementary school children

This report presents an analysis of 507 abnormal retinal reflex images taken of Huntsville kindergarten and first grade students. The retinal reflex images were obtained by using an MSFC-developed Generated Retinal Reflex Image System (GRRIS) photorefractor. The system uses a 35 mm camera with a telephoto lens with an electronic flash attachment. Slide images of the eyes were examined for abnormalities. Of a total of 1835 students screened for ocular abnormalities, 507 were found to have abnormal retinal reflexes. The types of ocular abnormalities detected were hyperopia, myopia, astigmatism, esotropia, exotropia, strabismus, and lens obstuctions. The report shows that the use of the photorefractor screening system is an effective low-cost means of screening school children for abnormalities.

Richardson, J.↗

Development of standardized specifications for screening space level integrated circuits and semiconductors

Standardized methods are established for screening of JAN B microcircuits and JANTXV semiconductor components for space mission or other critical applications when JAN S devices are not available. General specifications are provided which outline the DPA (destructive physical analysis), environmental, electrical, and data requirements for screening of various component technologies. This standard was developed for Air Force Space Division, and is available for use by other DOD agencies, NASA, and space systems contractors for establishing common screening methods for electronic components.

Source record↗

Gas flow across a wet screen - Analogy to a relief valve with hysteresis

The flow of gas through a wet fine-mesh screen is analyzed in terms of the capillary forces of the liquid wetting the screen and the pressure difference across the screen thickness driving the gas flow. Several different types of time-dependent flow are shown to be possible. The most interesting type is one in which the pressure difference opens small channels in the liquid, which are then closed rapidly by the wetting action of the liquid. The opening and closing exhibit hysteresis, and the flow is highly oscillatory.

Nachman, A.↗

Test and evaluation of the 2.4-micron photorefractor ocular screening system

An improved 2.4-m photorefractor ocular screening system was tested and evaluated. The photorefractor system works on the principal of obtaining a colored photograph of both human eyes; and, by analysis of the retinal reflex images, certain ocular defects can be detected such a refractive error, strabismus, and lens obstructions. The 2.4-m photorefractory system uses a 35-mm camera with a telephoto lens and an electronic flash attachment. Retinal reflex images obtained from the new 2.4-m system are significantly improved over earlier systems in image quality. Other features were also improved, notably portability and reduction in mass. A total of 706 school age children were photorefracted, 211 learning disabled and 495 middle school students. The total students having abnormal retinal reflexes were 156 or 22 percent, and 133 or 85 percent of the abnormal had refractive error indicated. Ophthalmological examination was performed on 60 of these students and refractive error was verified in 57 or 95 percent of those examined. The new 2.4-m system has a NASA patent pending and is authorized by the FDA. It provides a reliable means of rapidly screening the eyes of children and young adults for vision problems. It is especially useful for infants and other non-communicative children who cannot be screened by the more conventional methods such as the familiar E chart.

Richardson, J. R.↗

Vapor-screen flow-visualization experiments in the NASA Langley 0.3-m transonic cryogenic tunnel

The vortical flow on the leeward side of a delta-wing model has been visualized at several different tunnel conditions in the NASA Langley 0.3-Meter Transonic Cryogenic Tunnel using a vapor-screen flow-visualization technique. Vapor-screen photographs of the subject flow field are presented and interpreted relative to phenomenological implications. Results indicate that the use of nitrogen fog in conjunction with the vapor-screen technique is feasibile.

Selby, G. V.↗

Anharmonic and screening corrections to the melting of a two-dimensional charged colloidal crystal

The Kosterlitz-Thouless-Halperin-Nelson-Young theory of melting is applied to a two-dimensional charged colloidal crystal. The renormalization of elastic constants due to anharmonic and dislocation pair-screening effects is calculated. For colloidal spheres ('polyballs') suspended in a thin film of water confined between two glass plates whose surfaces are highly charged, as in recent experimental configurations, the corrections to the harmonic results simply require an altered effective polyball charge to reproduce virtually the identical melting curve of the harmonic approximation (which agrees well with experiment). The effect on the melting curve of added salt is also calculated; the corresponding experiments have yet to be performed. For a film between uncharged surfaces the anharmonic correction again softens the lattice significantly. Dislocation pair screening causes an additional but minor reduction of the elastic constants. Neither correction eliminates a nonmelting behavior characteristic of the two-dimensional screened Coulomb system in this configuration.

Chang, Enson↗

Cloud-screening for Africa using a geographically and seasonally variable infrared threshold

A spatially variable monthly, infrared cloud-threshold data base has been used to screen cloud-contaminated observations from radiances measured by the NOAA-9 AVHRR over Africa. Cloud-screening through a monthly average infrared threshold based on measured surface air temperature, which is geographically dependent, shows an improvement over using a seasonally and geographically independent thermal cloud threshold of 287 K. It is found that differences in cloud-screening for these two thresholds occur for cases of lower altitude clouds or subpixel clouds where the radiative temperature is higher than the 287 K infrared threshold, yet colder than the variable threshold developed by Stowe et al. (1988) for the Nimbus-7 global cloud climatology. The variable IR threshold is shown to be effective over persistently cloud-covered regions, such as the coastal region of the Gulf of Guinea, but may introduce some erroneous cloud identifications over mountains.

Eck, T. F.↗

Vaporization heat transfer of dielectric liquids on enhanced surfaces covered with screen wicks

Experiments were conducted to investigate the vaporization heat transfer characteristics for the dielectric liquid FC-72 on several wicking surfaces which may be used in flat-plate heat pipes. The wicking materials studied included microstructure enhanced surfaces and coarse surfaces covered with screen meshes. Experimental data for q versus deltaT curves and critical heat fluxes were obtained for the two different operating conditions of a heat pipe, evaporation, and shallow pool boiling. When the liquid level was above the heated surface, the height of the liquid level above the surface was varied from 0 to 10 mm. When the liquid level was below the heated surface, the distance from the liquid level to the edge of the surface was adjusted from 0 to 15 mm. Experimental results revealed that for shallow pool boiling when the heated surface was covered with a wire screen mesh, the heat transfer coefficient increased at lower heat fluxes but the critical heat flux (CHF) decreased for all the surfaces tested. In the case of evaporation, both CHF and the heat transfer coefficient increased as the microstructure surfaces were covered with screen meshes.

Gu, C. B.↗

A hydrodynamic model of the oscillating screen viscometer

The viscometer consists of an oscillating screen immersed in a fluid and free to rotate about an axis in its plane. The viscosity can be determined from the measured ratio of the periodic driving force to the screen motion when an adequate hydrodynamical model of the immersed oscillator is available. The screen is formed by a square mesh of thin wire whose dimensions invite comparison with asymptotic results for narrow hollow bodies translating in Stokes flow. These indicate that the closed hole structure of the grid plays an important role in determining its motion. It is shown that this role diminishes as the frequency increases. The computed results, obtained from a system of linear equations, are consistent with experimental values over the appropriate range of frequency.

Davis, A. M. J.↗

Variation with Mach Number of Static and Total Pressures Through Various Screens

Tests were conducted in the Langley 24-inch highspeed tunnel to ascertain the static-pressure and total-pressure losses through screens ranging in mesh from 3 to 12 wires per inch and in wire diameter from 0.023 to 0.041 inch. Data were obtained from a Mach number of approximately 0.20 up to the maximum (choking) Mach number obtainable for each screen. The results of this investigation indicate that the pressure losses increase with increasing Mach number until the choking Mach number, which can be computed, is reached. Since choking imposes a restriction on the mass rate of flow and maximum losses are incurred at this condition, great care must be taken in selecting the screen mesh and wire dimmeter for an installation so that the choking Mach number is

Adler, Alfred A↗

The field of a screened magnetic dipole

The purpose of this note is to quantitatively study the asymptotic behavior of the dipole magnetic field in the tail region of a paraboloidal or cylindrical model of the magnetosphere, assuming the complete screening of the internal field by magnetopause currents. This screening assumption is equivalent to imposing the boundary condition that the normal component of the magnetic field is zero at the magnetopause. With this boundary condition, the screened dipole field falls off exponentially with distance down the tail, in sharp constrast to the bare dipole field. Analytic expressions for a cylindrical and paraboloidal magnetopause are given.