Search NASA⌕ Search

SEARCH · Search NASA

Results for “Semiconductor Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

High-resolution x-ray spectroscopy with the EBIT Calorimeter Spectrometer

The EBIT Calorimeter Spectrometer (ECS) is a production-class 36 pixel x-ray calorimeter spectrometer that has been continuously operating at the Electron Beam Ion Trap (EBIT) facility at Lawrence Livermore National Laboratory for almost 2 years. The ECS was designed to be a long-lifetime, turn-key spectrometer that couples high performance with ease of operation and minimal operator intervention. To this end, a variant of the Suzaku/XRS spaceflight detector system has been coupled to a low-maintenance cryogenic system consisting of a long-lifetime liquid He cryostat, and a closed cycle, {sup 3}He pre-cooled adiabatic demagnetization refrigerator. The ECS operates for almost 3 weeks between cryogenic servicing and the ADR operates at 0.05 K for more than 60 hours between automatic recycles under software control. Half of the ECS semiconductor detector array is populated with mid-band pixels that have a resolution of 4.5 eV FWHM, a bandpass from 0.05-12 keV, and a quantum efficiency of 95% at 6 keV. The other half of the array has thick HgTe absorbers that have a bandpass from 0.3 to over 100 keV, an energy resolution of 33 eV FWHM, and a quantum efficiency of 32% at 60 keV. In addition, the ECS uses a real-time, autonomous, data collection and analysis system developed for the Suzaku/XRS instrument and implemented in off-the-shelf hardware for the ECS. Here we will discuss the performance of the ECS instrument and its implementation as a turnkey cryogenic detector system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Technique for Increasing the Sensitivity of a Solid-State Fission Probe

A small silicon p-n junction wafer, when coated with uranium 235, can be used as a compact fission probe for low power flux and power mapping. Because of the inverse relation between the magnitude of a neutron-induced fission pulse and the inherent capacitance of the detecting element (capacitance is proportional to area), the size, and hence the sensitivity, of the semiconductor detector has been limited. New developments in the field of semiconductor detectors have made it possible to fabricate large area detectors which are essentially free from the capacitance effect. However, preliminary results indicate that they are much more susceptible to radiation damage than the detectors described in this report and as such may not be suitable for flux mapping. increasing the sensitivity cannot be accomplished by simply fabricating a larger detector. It has been observed that by combining the silicon p-n junction wafers in a series configuration the capacitance effect can be bypassed, and a fission probe can be made with a resultant increase in sensitivity by a factor of ten while sustaining only a minor decrease in pulse height. Analysis further indicates that for n silicon wafers in series, if n(C(sub i)) + C(sub c)/C(sub b) less than 0.1 where C(sub i) and C(sub c) are the preamplifier input and cable capacitances, respectively, and C(sub b) is the junction capacitance of a single silicon wafer, there should be no substantial reduction in pulse height due to series circuitry.

Steinberg, Robert↗

Thermal neutron detection using a silicon pad detector and {sup 6}LiF removable converters

A semiconductor detector coupled with a neutron converter is a good candidate for neutron detection, especially for its compactness and reliability if compared with other devices, such as {sup 3}He tubes, even though its intrinsic efficiency is rather lower. In this paper we show a neutron detector design consisting of a 3 cm Multiplication-Sign 3 cm silicon pad detector coupled with one or two external {sup 6}LiF layers, enriched in {sup 6}Li at 95%, placed in contact with the Si active surfaces. This prototype, first characterized and tested at INFN Laboratori Nazionali del Sud and then at JRC Ispra, was successfully shown to detect thermal neutrons with the expected efficiency and an outstanding gamma rejection capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DEVELOPMENT OF CdZnTe RADIATION DETECTORS

Cadmium Zinc Telluride (CdZnTe or CZT) is a very attractive material for room-temperature semiconductor detectors because of its wide band-gap and high atomic number. Despite these advantages, CZT still presents some material limitations and poor hole mobility. In the past decade most of the developing CZT detectors focused on designing different electrode configurations, mainly to minimize the deleterious effect due to the poor hole mobility. A few different electrode geometries were designed and fabricated, such as pixelated anodes and Frisch-grid detectors developed at Brookhaven National Lab (BNL). However, crystal defects in CZT materials still limit the yield of detector-grade crystals, and, in general, dominate the detector's performance. In the past few years, our group's research extended to characterizing the CZT materials at the micro-scale, and to correlating crystal defects with the detector's performance. We built a set of unique tools for this purpose, including infrared (IR) transmission microscopy, X-ray micro-scale mapping using synchrotron light source, X-ray transmission- and reflection-topography, current deep level transient spectroscopy (I-DLTS), and photoluminescence measurements. Our most recent work on CZT detectors was directed towards detailing various crystal defects, studying the internal electrical field, and delineating the effects of thermal annealing on improving the material properties. In this paper, we report our most recent results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of attenuation coefficients of heavyweight concretes containing colemanite by using {sup 133}Ba radioactive isotope source - Paper 140

As it is well known, colemanite is a boron ore. Boron is one of the most important underground richness of Turkey. Boron is employed as a constituent material of neutron shielding because of its high absorption of thermal neutrons. Barite ore includes BaSO{sub 4}, which is a well photon radiation absorbent. The literature about radiation attenuation in heavy concretes (including boron and barite ores) is fairly abundant. Abdo and Abdo et al. theoretically calculated and determined cross section by using XCOM computer program for photon and neutron radiations shielding. Akkurt et al. measured radiation transmission of heavy concretes including normal and barite aggregates for different γ-ray energies and calculated linear attenuation coefficients. Bashter et al. studied heavy concretes including hematite-serpentine, ilmenite-limonite as control absorber in nuclear reactors γ-rays and neutron particles shielding. Bashter and Bashter et al. studied heavy concretes including hematite-serpentine, ilmenite-limonite, basalt-magnetite, ilmenite, basalt, steel and magnetite for only photon radiation shielding and calculated linear and mass attenuation coefficients from 10 keV to 1 GeV. Dealmeid et al. studied radiation transmission and angular distribution for 25 MV X-rays by using LINAC. Demir and Keles measured radiation transmission of concrete including boron waste for 59.54 and 80.99 keV γ-rays. Kaplan reported about many heavy concretes studies in his book. Kitis et al. studied heavy concretes including barite aggregates for cyclotron shielding. Mollah et al. determined concretes including ilmenite and magnetite aggregates for neutron shielding by using {sup 252}Cf radioactive source and BF{sub 3} neutron detector. Yarar and Bayuelken studied concretes including colemanite aggregates for neutron shielding. In this paper, we have measured radiation transmission of thirteen different heavy concretes produced by using barite, colemanite and normal aggregates for 276, 303, 356 and 383 keV γ-ray energies of {sup 133}Ba radioactive isotope by using CdTe semiconductor detector and calculated linear and mass attenuation coefficients. Results were compared to X-ray mass attenuation coefficient values of NIST. The attenuation of γ-ray photons is governed primarily by the atomic number and density of the concrete as a shielding material. Photon attenuation depends on pair production, photoelectric effect and Compton scattering. In this study, linear attenuation coefficients (μ) decrease with the increasing the photon energy for these concretes. Heavy elements there is a fairly sharp minimum in the absorption cross section at about this energy region. It is indicated that attenuation coefficient is useful parameter for radiation shielding. As known, the linear attenuation coefficients of the concretes used in this study at these γ-ray energies are not available in the literature by using CdTe semiconductor detectors. The data shows the effects of including boron-rich colemanite or barium-rich barite in addition to normal aggregate in the concrete mixtures. As would be expected, the barite is desirable for photon attenuation, while the colemanite is desirable for neutron attenuation. The concretes including barite and colemanite would be preferred as materials for building construction of radiation oncology departments, radiology departments, nuclear reactors and radiation research laboratories against photon and neutron particle radiations. But other aggregate properties of colemanite such as abrasion resistance and freeze-thaw durability are also found to be important for concrete but they cannot be quantified at this study. (authors)

36 MATERIALS SCIENCE↗

Final Report on Project “Ton-scale Germanium: Beyond Zeptobarn WIMP Cross-section”

The DOE CAREER proposal primarily focused on establishing a modern semiconductor detector fabrication facility that would provide significant improvement in the cost profile and performance of the cryogenic semiconductor detectors used by the CDMS experiment so as to enable a next generation ton-scale experiment. The proposal also included significant work on performing data analysis on the Soudan experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implementation of in vivo Dosimetry with Isorad{sup TM} Semiconductor Diodes in Radiotherapy Treatments of the Pelvis

This report describes the results obtained with the Isorad{sup TM} (Red) semiconductor detectors for implementing an in vivo dosimetry program in patients subject to radiotherapy treatment of the pelvis. Four n-type semiconductor diodes were studied to characterize them for the application. The diode calibration consisted of establishing reading-to-dose conversion factors in reference conditions and a set of correction factors accounting for deviations of the diode response in comparison to that of an ion chamber. Treatments of the pelvis were performed by using an isocentric 'box' technique employing a beam of 18 MV with the shape of the fields defined by a multileaf collimator. The method of Rizzotti-Leunen was used to assess the dose at the isocenter based on measurements of the in vivo dose at the entrance and at the exit of each radiation field. The in vivo dose was evaluated for a population of 80 patients. The diodes exhibit good characteristics for their use in in vivo dosimetry; however, the high attenuation of the beam ({approx}12% at 5.0-cm depth) produced, and some important correction factors, must be taken into account. The correction factors determined, including the source-to-surface factor, were within a range of {+-}4%. The frequency histograms of the relative difference between the expected and measured doses at the entrance, the exit, and the isocenter, have mean values and standard deviations of -0.09% (2.18%), 0.77% (2.73%), and -0.11% (1.76%), respectively. The method implemented has proven to be very useful in the assessment of the in vivo dose in this kind of treatment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Alpha particle response study of polycrstalline diamond radiation detector

Chemical vapor deposition has opened the possibility to grow high purity synthetic diamond at relatively low cost. This has opened up uses of diamond based detectors for wide range of applications. These detectors are most suitable for harsh environments where standard semiconductor detectors cannot work. In this paper, we present the fabrication details and performance study of polycrystalline diamond based radiation detector. Effect of different operating parameters such as bias voltage and shaping time for charge collection on the performance of detector has been studied.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Defects in {sup 6}LiInSe{sub 2} neutron detector investigated by photo-induced current transient spectroscopy and photoluminescence

{sup 6}LiInSe{sub 2} is a promising thermal neutron semiconductor detector material. The performance of the detector is affected by the carrier mobility-lifetime products. Therefore, defects that function as carrier recombination centers need to be identified. In this letter, characterization of defect levels in {sup 6}LiInSe{sub 2} by photo-induced current transient spectroscopy (PICTS) and photoluminescence is reported. PICTS measurements revealed electron-related defects located at 0.22, 0.36, and 0.55 eV and hole-related defects at 0.19, 0.30, and 0.73 eV. Free exciton and donor-acceptor pairs (DAP) emissions were observed. The PICTS defect level values are consistent with those extracted from DAP transitions.

36 MATERIALS SCIENCE↗

Special Nuclear Material Characterization Using Digital 3-D Position Sensitive CdZnTe Detectors and High Purity Germanium Spectrometers

Special nuclear material (SNM) monitoring often requires high resolution gamma-ray spectroscopy for material characterization. Portable systems and rapid deployment are also highly valued for some applications. Deployable gamma-ray imaging spectrometers using pixelated CdZnTe semiconductor detectors have become commercially available within the past three years to meet these requirements. CdZnTe systems have demonstrated room-temperature energy resolutions below 0.5% FWHM at 662 keV using single pixel events and below 0.7% FWHM at 662 keV using all events. The systems are able to go from storage to measurement in less than two minutes. Special nuclear materials were measured at the Y-12 National Security Complex and at the Device Assembly Facility at the Nevada National Security Site. The use of a CdZnTe system to measure uranium enrichment was demonstrated and uranium spectral features were compared to a commercially available high purity germanium (HPGe) spectrometer. The use of passive gamma ray spectroscopy techniques to estimate plutonium grade using CdZnTe detectors was demonstrated for the first time.

CdZnTe detectors, gamma-ray imaging, gamma-ray spe↗

Multilayer Semiconductor Charged-Particle Spectrometers for Accelerator Experiments

The current state of studies in the field of development of multilayer semiconductor systems (semiconductor detector (SCD) telescopes), which allow the energy to be precisely measured within a large dynamic range (from a few to a few hundred MeV) and the particles to be identified in a wide mass range (from pions to multiply charged nuclear fragments), is presented. The techniques for manufacturing the SCD telescopes from silicon and high-purity germanium are described. The issues of measuring characteristics of the constructed detectors and their impact on the energy resolution of the SCD telescopes and on the quality of the experimental data are considered. Much attention is given to the use of the constructed semiconductor devices in experimental studies at accelerators of PNPI (Gatchina), LANL (Los Alamos) and CELSIUS (Uppsala).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transport phenomena in intrinsic semiconductors and insulators at high current densities: Suppression of the broken neutrality drift

It is shown that, in addition to the diffusion and broken neutrality drift (BND) modes well-known for insulators and very lightly doped semiconductors, the quasineutral drift (QND) mode is possible. The transition from the BND to QND mode is accompanied by the appearance of a portion with a very sharp current rise in the current-voltage characteristic. This effect is observed in a new type of semiconductor detectors (CIDs, Current Injected Detectors) of high-intensity neutron and proton radiation, suggested, in particular, for Large Hadron Collider. The effect is unambiguously attributed now to the presence of radiation-induced deep centers in a semiconductor. It is shown, however, in this paper that the effect of a very sharp rise in current upon a slight increase in voltage is even possible when there are no deep centers. An equation adequately describing the possible transport modes in intrinsic semiconductors and insulators is derived. The results of an analytical study are confirmed by an adequate simulation.

36 MATERIALS SCIENCE↗

First-principles study of defects and carrier compensation in semiconductor radiation detector materials

We discuss defect engineering strategies in radiation detector materials. The goal is to increase resistivity by defect-induced Fermi level pinning without causing defect-induced reductions in the carrier drifting length. We show calculated properties of various intrinsic defects and impurities in CdTe. We suggest that the defect complex of a hydrogen atom and an isovalent impurity on an anion site may be an excellent candidate in many semiconductors for Fermi level pinning without carrier trapping.

08 HYDROGEN↗

Full characterization of laser-accelerated ion beams using Faraday cup, silicon carbide, and single-crystal diamond detectors

Multi-MeV beams of light ions have been produced using the 300 picosecond, kJ-class iodine laser, operating at the Prague Asterix Laser System facility in Prague. Real-time ion diagnostics have been performed by the use of various time-of-flight (TOF) detectors: ion collectors (ICs) with and without absorber thin films, new prototypes of single-crystal diamond and silicon carbide detectors, and an electrostatic ion mass spectrometer (IEA). In order to suppress the long photopeak induced by soft X-rays and to avoid the overlap with the signal from ultrafast particles, the ICs have been shielded with Al foil filters. The application of large-bandgap semiconductor detectors (>3 eV) ensured cutting of the plasma-emitted visible and soft-UV radiation and enhancing the sensitivity to the very fast proton/ion beams. Employing the IEA spectrometer, various ion species and charge states in the expanding laser-plasma have been determined. Processing of the experimental data based on the TOF technique, including estimation of the plasma fast proton maximum and peak energy, ion beam currents and total charge, total number of fast protons, as well as deconvolution processes, ion stopping power, and ion/photon transmission calculations for the different metallic filters used, are reported.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental study of double-{beta} decay modes using a CdZnTe detector array

An array of sixteen 1 cm{sup 3} CdZnTe semiconductor detectors was operated at the Gran Sasso Underground Laboratory (LNGS) to further investigate the feasibility of double-{beta} decay searches with such devices. As one of the double-{beta} decay experiments with the highest granularity the 4x4 array accumulated an overall exposure of 18 kg days. The setup and performance of the array is described. Half-life limits for various double-{beta} decay modes of Cd, Zn, and Te isotopes are obtained. No signal has been found, but several limits beyond 10{sup 20} years have been performed. They are an order of magnitude better than those obtained with this technology before and comparable to most other experimental approaches for the isotopes under investigation. An improved limit for the {beta}{sup +}/EC decay of {sup 120}Te is given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗