Search NASA⌕ Search

SEARCH · Search NASA

Results for “Shutdown”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Multi-Step CADIS method for shutdown dose rate calculations and uncertainty propagation

Shutdown dose rate (SDDR) analysis requires (a) a neutron transport calculation to estimate neutron flux fields, (b) an activation calculation to compute radionuclide inventories and associated photon sources, and (c) a photon transport calculation to estimate final SDDR. In some applications, accurate full-scale Monte Carlo (MC) SDDR simulations are needed for very large systems with massive amounts of shielding materials. However, these simulations are impractical because calculation of space- and energy-dependent neutron fluxes throughout the structural materials is needed to estimate distribution of radioisotopes causing the SDDR. Biasing the neutron MC calculation using an importance function is not simple because it is difficult to explicitly express the response function, which depends on subsequent computational steps. Furthermore, the typical SDDR calculations do not consider how uncertainties in MC neutron calculation impact SDDR uncertainty, even though MC neutron calculation uncertainties usually dominate SDDR uncertainty.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design Report for the ½ Scale Air-Cooled RCCS Tests in the Natural convection Shutdown heat removal Test Facility (NSTF)

The Natural convection Shutdown heat removal Test Facility (NSTF) is a large scale thermal hydraulics test facility that has been built at Argonne National Laboratory (ANL). The facility was constructed in order to carry out highly instrumented experiments that can be used to validate the performance of passive safety systems for advanced reactor designs. The facility has principally been designed for testing of Reactor Cavity Cooling System (RCCS) concepts that rely on natural convection cooling for either air or water-based systems. Standing 25-m in height, the facility is able to supply up to 220 kW at 21 kW/m 2 to accurately simulate the heat fluxes at the walls of a reactor pressure vessel. A suite of nearly 400 data acquisition channels, including a sophisticated fiber optic system for high density temperature measurements, guides test operations and provides data to support scaling analysis and modeling efforts. Measurements of system mass flow rate, air and surface temperatures, heat flux, humidity, and pressure differentials, among others; are part of this total generated data set. The following report provides an introduction to the top level-objectives of the program related to passively safe decay heat removal, a detailed description of the engineering specifications, design features, and dimensions of the test facility at Argonne. Specifications of the sensors and their placement on the test facility will be provided, along with a complete channel listing of the data acquisition system.

42 ENGINEERING↗

Benchmark specifications and data requirements for EBR-II shutdown heat removal tests SHRT-17 and SHRT-45R

Argonne National Laboratory’s (ANL) Experimental Breeder Reactor II (EBR-II) was a liquid metal reactor (LMR) with a sodium-bonded metallic fuel core that contributed very favorably to the reactor’s negative reactivity feedback. On June 20, 1984, a severe loss-of-flow test in the Shutdown Heat Removal Test (SHRT) series demonstrated the effectiveness of natural circulation in the EBR-II reactor. This test was SHRT-17 and at the beginning of the test the primary pumps were tripped at the same time as a full control rod insertion.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Oak Ridge National Laboratory Shutdown Dose Rate Code Suite

The Oak Ridge National Laboratory (ORNL) shutdown dose rate (SDDR) code suite calculates gamma dose rates at a location of interest due to activation of materials. The code suite is based on the rigorous two-step (R2S) method that involves two radiation transport calculations: (1) neutron radiation transport to determine neutron fluxes in the material for which activation calculations will be performed and (2) gamma radiation transport to determine dose rates at a location of interest, due to material activation. The ORNL SDDR code suite is used to determine an importance function that characterizes the neutron’s importance to the final SDDR when the Monte Carlo radiation transport method is used. This report demonstrates how the ORNL SDDR code suite is implemented through the following codes: Monte Carlo N-Particle (MCNP) code Version 5-1.60, Oak Ridge Isotope Generator (ORIGEN), MSX suite of utilities, Neutron Activation Gamma Source Sampler (NAGSS), and Automated Variance Reduction Generator (ADVANTG). For this demonstration, the International Thermonuclear Experimental Reactor (ITER) SDDR benchmark problem is used and the dose rate result is compared to previously published work.

61 RADIATION PROTECTION AND DOSIMETRY↗

CMS DAQ Current and Future Hardware Upgrades Up to Post Long Shutdown 3 (LS3) Times

Following the first LHC collisions seen and recorded by CMS in 2009, the DAQ hardware went through a major upgrade during LS1 (2013- 2014) and new detectors have been connected during 2015-2016 and 2016-2017 winter shutdowns. Now, LS2 (2019-2020) and LS3 (2024-mid 2026) are actively being prepared. This paper shows how CMS DAQ hardware has evolved from the beginning and will continue to evolve in order to meet the future challenges posed by High Luminosity LHC (HL-LHC) and the CMS detector evolution. In particular, post LS3 DAQ architectures are focused upon.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computer study of emergency shutdowns of a 60-kilowatt reactor Brayton space power system

A digital computer study of emergency shutdowns of a 60-kWe reactor Brayton power system was conducted. Malfunctions considered were (1) loss of reactor coolant flow, (2) loss of Brayton system gas flow, (3)turbine overspeed, and (4) a reactivity insertion error. Loss of reactor coolant flow was the most serious malfunction for the reactor. Methods for moderating the reactor transients due to this malfunction are considered.

Tew, R. C.↗

Transient shutdown analysis of low-temperature thermal diodes

The various thermal diodes available for use in cryogenic systems are described. Two diode types, liquid-trap and liquid-blockage diodes, were considered to be the most attractive, and thermal models were constructed to predict their behavior in the reverse mode. The diodes, which are of similar size and throughput, were also examined experimentally in a parallel test setup under nominally identical conditions. Their characteristics were ascertained in terms of forward-mode and reverse-mode conductances, shutdown times and energies, and recovery to forward-mode operation with ethane as the working fluid in the temperature range 170 K to 220 K. Results show that the liquid-blockage diode is the quicker of the two diodes to shut down from the forward mode (8 min as opposed to 10 min). However, the liquid-blockage diode has a larger reverse-mode conductance which results in a greater overall evaporator temperature rise. The importance of the relative size and heat inputs to the condenser/reservoir configuration of the liquid-blockage diode and the evaporator trap configuration for the liquid-trap diode are demonstrated. Also included are data which show the susceptibility of the diodes to recovery to forward-mode operation. Guidelines for the choice of a particular diode for an actual application are given.

Williams, R. J.↗

An investigation of space shuttle main engine shutdown chugging instability

The Space Shuttle Main Engines experience a low frequency pressure pulsation in both the fuel and oxidizer preburners during shutdown. The pressure pulsations (chugging) occur during the helium purge of oxidizer from the preburner manifolds. Possible causes and triggering mechanisms are considered as details of the chugging process are presented and discussed. A simple chugging model capable of predicting pressure excursion amplitudes and frequencies is proposed and preliminary results presented.

George, P. E., II↗

Hydraulic Shutdown Monitor

Adding switch allows inappropriate control actions to be overridden. Four-pole, double-throw switch added to front panel of controller to disable tracking-error and endpoint-error circuitry yet still retain overload-detection capability. Previously, it was necessary to use adjustable-voltage-level detection equipment connected with cables to hydraulic "dump" or shutdown circuitry in controller.

Fleming, S. T.↗

Investigation and modeling of space shuttle main engine shutdown transient chugging

The space shuttle main engines experience a low frequency pressure pulsation in both the fuel and oxidizer preburners during the shutdown transient. This pressure pulsation, called chugging, has been linked to undesirable bearing loads and possible damage to the spark ignitor supply piping for the fuel preburner. The problem is briefly described and a model is proposed that includes: (1) a transient stirred tank reactor model for the combustion chamber, (2) a resistance capacitance model for the supply piping and (3) purge gas/liquid oxygen interface tracking.

George, P. E., II↗