Search NASA⌕ Search

SEARCH · Search NASA

Results for “Simulation system performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Enabling parallel simulation of large-scale HPC network systems

Here, with the increasing complexity of today’s high-performance computing (HPC) architectures, simulation has become an indispensable tool for exploring the design space of HPC systems—in particular, networks. In order to make effective design decisions, simulations of these systems must possess the following properties: (1) have high accuracy and fidelity, (2) produce results in a timely manner, and (3) be able to analyze a broad range of network workloads. Most state-of-the-art HPC network simulation frameworks, however, are constrained in one or more of these areas. In this work, we present a simulation framework for modeling two important classes of networks used in today’s IBM and Cray supercomputers: torus and dragonfly networks. We use the Co-Design of Multi-layer Exascale Storage Architecture (CODES) simulation framework to simulate these network topologies at a flit-level detail using the Rensselaer Optimistic Simulation System (ROSS) for parallel discrete-event simulation. Our simulation framework meets all the requirements of a practical network simulation and can assist network designers in design space exploration. First, it uses validated and detailed flit-level network models to provide an accurate and high-fidelity network simulation. Second, instead of relying on serial time-stepped or traditional conservative discrete-event simulations that limit simulation scalability and efficiency, we use the optimistic event-scheduling capability of ROSS to achieve efficient and scalable HPC network simulations on today’s high-performance cluster systems. Third, our models give network designers a choice in simulating a broad range of network workloads, including HPC application workloads using detailed network traces, an ability that is rarely offered in parallel with high-fidelity network simulations

97 MATHEMATICS AND COMPUTING↗

New Automotive Air Conditioning System Simulation Tool Developed in MATLAB/Simulink

Further improvements in vehicle fuel efficiency require accurate evaluation of the vehicle's transient total power requirement. When operated, the air conditioning (A/C) system is the largest auxiliary load on a vehicle; therefore, accurate evaluation of the load it places on the vehicle's engine and/or energy storage system is especially important. Vehicle simulation software, such as 'Autonomie,' has been used by OEMs to evaluate vehicles' energy performance. A transient A/C simulation tool incorporated into vehicle simulation models would also provide a tool for developing more efficient A/C systems through a thorough consideration of the transient A/C system performance. The dynamic system simulation software Matlab/Simulink was used to develop new and more efficient vehicle energy system controls. The various modeling methods used for the new simulation tool are described in detail. Comparison with measured data is provided to demonstrate the validity of the model.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Flame acceleration and transition to detonation in a pre-/main-chamber combustion system

Numerical simulations are performed to study the mechanism of deflagration to detonation transition (DDT) in a pre-/main-chamber combustion system with a stoichiometric ethylene–oxygen mixture. A Godunov algorithm, fifth-order in space, and third-order in time, is used to solve the fully compressible Navier–Stokes equations on a dynamically adapting mesh. A single-step, calibrated chemical diffusive model described by Arrhenius kinetics is used for energy release and conservation between the fuel and the product. The two-dimensional simulation shows that a laminar flame grows in the pre-chamber and then develops into a jet flame as it passes through the orifice. A strong shock forms immediately ahead of the flame, reflecting off the walls and interacting with the flame front. The shock–flame interactions are crucial for the development of flame instabilities, which trigger the subsequent flame development. The DDT arises due to a shock-focusing mechanism, where multiple shocks collide at the flame front. A chemical explosive mode analysis (CEMA) criterion is developed to study the DDT ignition mode. Preliminary one-dimensional computations for a laminar propagating flame, a fast flame deflagration, and a Chapman–Jouguet detonation are conducted to demonstrate the validity of CEMA on the chemical-diffusive model, as well as to determine the proper conditioning value for CEMA diagnostic. The two-dimensional analysis with CEMA indicates that the DDT initiated by the shock-focusing mechanism can form a strong thermal expansion region at the flame front that features large positive eigenvalues for the chemical explosive mode and dominance of the local autoignition mode. Thus, the CEMA criterion proposed in this study provides a robust diagnostic for identifying autoignition-supported DDT, of which the emergence of excessive local autoignition mode is found to be a precursor. The effect of grid size, initial temperature, and orifice size are then evaluated, and results show that although the close-chamber DDT is highly stochastic, the detonation initiation mechanism remains robust.

42 ENGINEERING↗

Experimental validation of a co-simulation architecture for modeling whole-building and detailed electrical distribution performance

This article presents an experimental validation of a co-simulation architecture for simultaneously modeling whole-building energy performance and detailed building electrical distribution system performance. The co-simulation architecture consists of a whole-building energy model (EnergyPlus®) embedded within a Modelica-based building electrical distribution system library called the Building Electrical Efficiency Analysis Model (BEEAM) using the Functional Mock-up Interface standard. We validate the model using experimental data collected at a full-scale test cell within Lawrence Berkeley National Laboratory’s FLEXLAB® facility. In conclusion, we show that the co-simulation model accurately predicts the electrical, mechanical, and thermal performance of the test cell for typical loads with both an AC and a DC electrical distribution topology.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Comparative Study on the Environmental Impact of CO2 Supermarket Refrigeration Systems

Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Accordingly, the interest in using natural refrigerants, such as carbon dioxide (CO2), and new refrigerant blends with low GWP in such systems is increasing. In this paper, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of three supermarket refrigeration systems. These systems include a transcritical CO2 booster system, a cascade CO2/N-40 system, and a baseline R-404A multiplex direct expansion system. The study is performed for cities representing different climates within the USA using EnergyPlus to simulate the systems' hourly performance. Finally, a parametric analysis is performed to study the impact of annual leak rate on the systems' LCCP.

LCCP↗

A comparative study on the environmental impact of supermarket refrigeration systems using low GWP refrigerants

Supermarket refrigeration systems have high environmental impact due to their large refrigerant charge and high leak rates. Consequently, the interest in using low GWP refrigerants such as carbon dioxide (CO 2 ) and new refrigerant blends is increasing. In this study, an open-source Life Cycle Climate Performance (LCCP) framework is presented and used to compare the environmental impact of four supermarket refrigeration systems: a transcritical CO 2 booster system, a cascade CO 2 /N-40 system, a combined secondary circuit with central DX N-40/L-40 system, and a baseline multiplex direct expansion system utilizing R-404A and N-40. The study is performed for different climates within the USA using EnergyPlus to simulate the systems' hourly performance. Finally, further analyses are presented such as parametric, sensitivity, and uncertainty analyses to study the impact of different system parameters on the LCCP.

54 ENVIRONMENTAL SCIENCES↗

Metrics for Availability Analysis Using a Discrete Event Simulation Method

The system performance metric 'availability' is a central concept with respect to the concerns of a plant's operators and owners, yet it can be abstract enough to resist explanation at system levels. Hence, there is a need for a system-level metric more closely aligned with a plant's (or, more generally, a system's) raison d'etre. Historically, availability of repairable systems - intrinsic, operational, or otherwise - has been defined as a ratio of times. This paper introduces a new concept of availability, called endogenous availability, defined in terms of a ratio of quantities of product yield. Endogenous availability can be evaluated using a discrete event simulation analysis methodology. A simulation example shows that endogenous availability reduces to conventional availability in a simple series system with different processing rates and without intermediate storage capacity, but diverges from conventional availability when storage capacity is progressively increased. It is shown that conventional availability tends to be conservative when a design includes features, such as in - process storage, that partially decouple the components of a larger system.

99 GENERAL AND MISCELLANEOUS↗

Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

14 SOLAR ENERGY↗

Multiscale Solar Water Heating (MSWH) v1.0

The main purpose of the software is to model energy use for individual and community scale solar water heating projects in California. Usage The user provides a climate zone for a project, an occupancy for each household and whether any of the occupants stay at home during the day. The software can then load a set of example California specific hourly domestic hot water end-use load profiles from a database, size and locate the systems. The user can now simulate the hourly system performance over a period of one representative year, visualize and explore the simulation results using time-series plots for temperature profiles, heat and power rates, or look at annual summaries. Similarly the user can model individual household solar water heating projects and base case conventional gas tank water heater systems, such that the results can be compared between the individual, community and base case systems. This functionality is readily available through a Jupyter notebook and a Django web framework, depending on what level of detail the user would like to access. Features - Python module to calculate solar irradiation on a tilted surface - Python module with simplified component models for Converter (solar collectors, electric resistance heater, gas burner, photovoltaic panels, heat pump), Storage (solar thermal tank, heat pump thermal tank, conventional gas tank water heater), and Distribution (distribution and solar pump, piping losses) components - Python module with preconfigured system simulation models for: base case gas tank water heaters, solar thermal water heaters (solar collector feeding a storage tank, with a tankeless gas water heater backup in a new installation cases and a base case gas tank water heater in a retrofit case) and solar electric water heaters (heat pump storage tank with an electric resistance backup) - Database with component performance parameters, California specific weather data and domestic hot water end-use load profiles - Django web framework to configure project, parametrize components and run simulation from a web browser The package contains functional and unit tests and it is structured so that it can be extended with further technologies, applications and locations.

Grahovac, Milica↗

The Urban Deployment Model: A Toolset for the Simulation and Performance Characterization of Radiation Detector Deployments in Urban Environments

Static and mobile radiation detectors can be deployed in urban environments for a range of nuclear security applications, including radiological source search-and-tracking scenarios. Modeling detector performance for such applications is challenging, as it does not depend solely on the detector capabilities themselves. Many factors must be taken into consideration, including specific source and background signatures, the topology and constraints of the deployment environment, the presence of nuisance sources, and whether detectors are mobile or static. When considering the simultaneous deployment of multiple, heterogeneous detectors, assessment of the system-wide performance requires the simulation of the individual detectors, and a system-level analysis of the detection performance. In radiological source search-and-tracking scenarios, performance is mostly dominated by the probability of encounter, which depends on the specifics of a given deployment, e.g., static vs. mobile detectors or a combination of both modalities, the number of detectors deployed, the dynamic vs. static setting of false alarm rates, and individual vs. networked operation. The Urban Deployment Model (UDM) toolset was specifically developed to cover the gap in the available generic frameworks for the simulation of radiation detector deployments at city scales. UDM provides a unified and modular framework to support the simulation and performance characterization of heterogeneous detector deployments in urban environments. This paper presents the key components along the UDM workflow.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

DYNAMIC - The Nonlinear Dynamical Network Simulator v. 0.1

The purpose of the DYNAMIC software system is to perform simulations to validate a new research concept called “Chaotic Logic” which we recently published. The problem to be solved is to simulate certain networks of nonlinearly-interacting dynamical variables, and collect statistics on their behavior, to show that they can reliably perform useful computations. The dynamical trajectories for such networks are computed by time integration of their Hamilton’s equations.

Frank, MichaelP.↗

Faster than Real-Time Dynamic Simulation for Large-Size Power System with Detailed Dynamic Models using High-Performance Computing Platform

This paper presents a faster-than-real-time dynamic simulation software package that is designed for large-size power system dynamic simulation. It was developed on the GridPACKTM high-performance computing (HPC) framework. The key features of the developed software package include (1) faster-than-real-time dynamic simulation for a WECC system (17,000 buses) with different types of detailed generator, controller, and relay dynamic models, (2) a decoupled parallel dynamic simulation algorithm with optimized computation architecture to better leverage HPC resources and technologies, (3) options for HPC-based linear and iterative solvers, (4) hidden HPC details, such as data communication and distribution, to enable development centered on mathematical models and algorithms rather than on computational details for power system researchers, and (5) easy integration of new dynamic models and related algorithms into the software package.

Huang, Renke↗

Extended-Term Dynamic Simulations with High Penetrations of Photovoltaic Generation.

The uncontrolled intermittent availability of renewable energy sources makes integration of such devices into today's grid a challenge. Thus, it is imperative that dynamic simulation tools used to analyze power system performance are able to support systems with high amounts of photovoltaic (PV) generation. Additionally, simulation durations expanding beyond minutes into hours must be supported. This report aims to identify the path forward for dynamic simulation tools to accom- modate these needs by characterizing the properties of power systems (with high PV penetration), analyzing how these properties affect dynamic simulation software, and offering solutions for po- tential problems. We present a study of fixed time step, explicit numerical integration schemes that may be more suitable for these goals, based on identified requirements for simulating high PV penetration systems. We also present the alternative of variable time step integration. To help determine the characteristics of systems with high PV generation, we performed small signal sta- bility studies and time domain simulations of two representative systems. Along with feedback from stakeholders and vendors, we identify the current gaps in power system modeling including fast and slow dynamics and propose a new simulation framework to improve our ability to model and simulate longer-term dynamics.

14 SOLAR ENERGY↗

Updated (BP3) Technical and Economic Feasibility Study - Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

This topical report summarizes the results of an updated Technical & Economic Feasibility Study (T&EFS) which was conducted in Budget Period 3 of the project to evaluate the performance and cost of the Electrochemical Membrane (ECM)-based CO2 capture system. The ECM technology is derived from commercially available inorganic membranes; the same used in FuelCell Energy’s commercial fuel cell power plants and sold under the trade name Direct FuelCell® (DFC®). The ECM stacks are utilized in the Combined Electric Power (generation) And Carbon dioxide Separation (CEPACS) systems which can be deployed as add-ons to conventional power plants (Pulverized Coal, Combined Cycle, etc.) or industrial facilities to simultaneously produce power while capturing >90% of the CO2 from the flue gas. In this study, an ECM-based CEPACS plant was designed to capture and compress >90% of the CO2 (for sequestration or beneficial use) from the flue gas of a reference 550 MW (nominal, net AC) Pulverized Coal (PC) Rankine Cycle (Subcritical steam) power plant. ECM performance was updated based on bench scale ECM stack test results. The system process simulations were performed to generate the CEPACS plant performance estimates. The performance assessment included estimation of the parasitic power consumption for CO2 capture and compression, and the efficiency impact on the PC plant. While the ECM-based CEPACS system for the 550 MW PC plant captures 90% of CO2 from the flue gas, it generates additional (net AC) power after compensating for the auxiliary power requirements of CO2 capture and compression. An equipment list, ECM stacks packaging design, and CEPACS plant layout were developed to facilitate the economic analysis. Vendor quotes were also solicited. The economic feasibility study included estimation of CEPACS plant capital cost, cost of electricity (COE) analyses and estimation of cost per ton of CO2 captured. The incremental COE for the ECM-based CO2 capture is expected to meet U.S. DOE’s target of 35%. This study has indicated that CEPACS systems offer significant benefits with respect to cost, performance, water consumption and emissions to environment. The realization of these benefits will provide a single solution to carbon dioxide capture in addition to meeting the increasing demand for electricity.

20 FOSSIL-FUELED POWER PLANTS↗

Scintillation light in SBND: simulation, reconstruction, and expected performance of the photon detection system

SBND is the near detector of the Short-Baseline Neutrino program at Fermilab. Its location near to the Booster Neutrino Beam source and relatively large mass will allow the study of neutrino interactions on argon with unprecedented statistics. This paper describes the expected performance of the SBND photon detection system, using a simulated sample of beam neutrinos and cosmogenic particles. Its design is a dual readout concept combining a system of 120 photomultiplier tubes, used for triggering, with a system of 192 X-ARAPUCA devices, located behind the anode wire planes. Furthermore, covering the cathode plane with highly-reflective panels coated with a wavelength-shifting compound recovers part of the light emitted towards the cathode, where no optical detectors exist. We show how this new design provides a high light yield and a more uniform detection efficiency, an excellent timing resolution and an independent 3D-position reconstruction using only the scintillation light. Finally, the whole reconstruction chain is applied to recover the temporal structure of the beam spill, which is resolved with a resolution on the order of nanoseconds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Updated (BP3) Technical and Economic Feasibility Study - Electrochemical Membrane for Carbon Dioxide Capture and Power Generation

This topical report summarizes the results of an updated Technical & Economic Feasibility Study (T&EFS) which was conducted in Budget Period 3 of the project to evaluate the performance and cost of the Electrochemical Membrane (ECM)-based CO 2 capture system. The ECM technology is derived from commercially available inorganic membranes; the same used in FuelCell Energy’s commercial fuel cell power plants and sold under the trade name Direct FuelCell® (DFC®). The ECM stacks are utilized in the Combined Electric Power (generation) And Carbon dioxide Separation (CEPACS) systems which can be deployed as add-ons to conventional power plants (Pulverized Coal, Combined Cycle, etc.) or industrial facilities to simultaneously produce power while capturing >90% of the CO 2 from the flue gas. In this study, an ECM-based CEPACS plant was designed to capture and compress >90% of the CO 2 (for sequestration or beneficial use) from the flue gas of a reference 550 MW (nominal, net AC) Pulverized Coal (PC) Rankine Cycle (Subcritical steam) power plant. ECM performance was updated based on bench scale ECM stack test results. The system process simulations were performed to generate the CEPACS plant performance estimates. The performance assessment included estimation of the parasitic power consumption for CO 2 capture and compression, and the efficiency impact on the PC plant. While the ECM-based CEPACS system for the 550 MW PC plant captures 90% of CO 2 from the flue gas, it generates additional (net AC) power after compensating for the auxiliary power requirements of CO 2 capture and compression. An equipment list, ECM stacks packaging design, and CEPACS plant layout were developed to facilitate the economic analysis. Vendor quotes were also solicited. The economic feasibility study included estimation of CEPACS plant capital cost, cost of electricity (COE) analyses and estimation of cost per ton of CO 2 captured. The incremental COE for the ECM-based CO 2 capture is expected to meet U.S. DOE’s target of 35%. This study has indicated that CEPACS systems offer significant benefits with respect to cost, performance, water consumption and emissions to environment. The realization of these benefits will provide a single solution to carbon dioxide capture in addition to meeting the increasing demand for electricity.

20 FOSSIL-FUELED POWER PLANTS↗

Dynamic Human-in-the-Loop Simulated Nuclear Power Plant Thermal Dispatch System Demonstration and Evaluation Study

An Idaho National Laboratory research team performed a human-in-the-loop study with two formerly licensed retired operators to evaluate thermal power dispatch operations supported by the modified GSE Systems GPWR plant simulator. Virtual representations of the analog control panels were presented on touch-screen bays configured to mimic the control room layout in the newly renovated Human Systems Simulation Laboratory. The operators performed 15 scenarios covering normal evolutions to transition the plant from full turbine operation to joint turbine and thermal power dispatch operations in addition to transient response scenarios induced with simulated faults to evaluate the impact of thermal power dispatch system on operator and plant responses. A prototype human-system interface (HSI) was developed and displayed in tandem with the virtual analog panels to support the operators executing the procedurally drive evolutions and transient responses. An interdisciplinary team of operations experts, nuclear engineers, and human factors experts observed the operators performing the scenarios to evaluate the operations. Only a preliminary analysis of the results has been performed. The full analysis will be shared in a milestone report scheduled for release at the end of September; however, some high-level conclusions were readily available. Two high level findings for the system design were captured in the study. The manual control supported by the HSI to transition from standard operations to thermal power dispatch operation imposed a considerable amount of workload on the operators due to tedious manual valve manipulations and system monitoring required to verify their intended effect. An additional operator would be required in the control room to support the daily evolution. Automatic control for the transition was deemed a requirement for plant adoption without imposing additional staffing costs. The second finding was the necessity for an automatic thermal power dispatch system trip isolation function linked to a turbine and reactor trip signal. The operators completed scenarios with automatic isolation functionality and manually required actuation of the thermal power dispatch system. The operator response was sufficiently slower in the manual trip condition, such that operators were unable to manually actuate key post trip safety functions an indicate a degraded control capability that should be avoided. With an automatic trip signal little to no impact of the thermal power dispatch system was identified on the primary plant response and therefore the system could be readily and safely adopted. Together these two findings represent the need to support the adoption of thermal power dispatch capability into existing operations by leveraging automation to augment any additional operator tasking required to control and monitor an additional system beyond existing operations.

99 GENERAL AND MISCELLANEOUS↗