Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single Event Effect”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

96 records · Page 6

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Measurements of Beam Spin Asymmetries in p+p0 and p´p0 Dihadron Production at CLAS12

Semi-Inclusive Deep Inelastic Scattering (SIDIS) is a powerful experimental tool for studying the internal structure and dynamics of the proton, revealing how quarks and gluons are distributed and interact within it. SIDIS describes a process where an elec tron scatters off one of the constituent quarks within the proton, causing it to undergo hadronization, creating multiple hadrons in the final state. Through factorization, the full process can be split into probabilistic components: one which describes the internal structure of the proton using Parton Distribution Functions (PDFs), and another which describes the hadronization process using Fragmentation Functions (FFs). These functions are non-perturbative quantities of Quantum Chromodynamics (QCD), meaning they cannot be calculated directly from first principles and must instead be extracted from experimental measurements. Acommon approach for accessing PDFs and FFs using SIDIS is to measure asymmetries. In this context, asymmetries correspond to subtle differences in the angular distribution of outgoing particles that arise when the spin orientation of the incoming beam or target is reversed. Because many of these effects only appear when spin is involved, they isolate specific, nuanced properties of the proton’s spin-structure that are otherwise hidden in spin averaged measurements. In practice, they show up as specific azimuthal modulations (e.g., sin ¿R, sin(¿h ´ ¿R)), whose amplitudes isolate convolutions of PDFs and FFs at leading and subleading twist. Non-zero asymmetries of these angular distributions can be traced back to unique combinations of PDFs and FFs, offering a way to probe them directly. In this work, we measure SIDIS by analyzing high energy electron-proton scattering events using the CLAS12 detector at Jefferson Lab. This study focuses on subset of SIDIS referred to as dihadron SIDIS, where pairs of hadrons — here p+p0 and p´p0 — are observed. We analyzed these dihadrons using detector data collected during Fall 2018 and Spring 2019, where longitudinally polarized electrons from the CEBAF accelerator were incident on a liquid hydrogen target. A photon classifier using a Gradient Boosted Trees (GBTs) architecture was trained using Monte Carlo simulations to reduce the amount of iv false combinatorial background p0’s. When deployed on experimental data, the model in creases our dihadron statistics by up to five-fold compared to previous CLAS12 p0 analyses. This work reports the first measurements of beam spin asymmetries for p+p0 and p´p0 dihadron production in SIDIS. The measured asymmetries offer new insights to the spin-dependent structure and dynamics within the proton, as well as the spin-dependent properties of quark fragmentation. Non-zero twist-3 sin¿R amplitudes are observed, pro viding sensitivity to the subleading twist PDF e(x). The PDF e(x) encodes quark-gluon correlations within the proton — a property that is otherwise inaccessible at leading twist. Additionally, this work measured significant twist-2 modulations carried by sin(¿h ´ ¿R) and sin(2¿h ´2¿R), providing experimental access to the helicity dihadron fragmentation function (DiFF) GK 1 . Because there is no equivalent quark helicity-dependent FF in single pion SIDIS, the DiFF GK 1 offers a unique lens into novel spin-dependent fragmentation. For instance, the twist-2 modulations observed in this study are enhanced by vector mesons created during fragmentation — a behavior predicted by phenomenological models. This study broadens our understanding of dihadron fragmentation, revealing new details about the flavor and charge dependence of hadronization.

Matousek, Gregory [Duke Univ., Durham, NC (United ↗

Relating flow resistance to equivalent roughness

Describing flow resistance using the physical properties of an underlying surface is a recalcitrant problem in overland flow models. If discharge measurements are available, an equivalent roughness (e.g., Manning’s n) can be calibrated to represent the effects of surface properties within the domain with a single numerical value. Alternatively, the flow resistance can be estimated from discharge and velocity measured at a point, typically a runoff plot outlet. However, such experimental estimates are often inconsistent with the equivalent roughness determined from calibration to discharge, even if both derive from the same dataset. For example, if Manning’s equation is used to parameterize flow resistance, the Manning’s n obtained by calibrating a model to discharge differs from the value of n calculated from measured flow and velocity at the hillslope outlet. Here, this discrepancy is resolved by deriving a correction factor relating experimentally-determined flow resistance to the equivalent roughness. The derived correction factor is tested for four commonly-used resistance formulations using 129 rainfall simulator experiments. The correction factor is necessary to reproduce measured velocities, and yields minor improvements in discharge prediction. Plain Language Summary: Accurate runoff prediction is needed for land and water management in dryland regions, where sporadic and limited rainfall necessitate efficient water use and drought mitigation strategies. The skill of runoff models is known to be hindered by out ability to estimate flow resistance, which is the quantity that describes how energy is lost from flowing water to the underlying surface. Typically, models represent flow resistance with an equivalent roughness, e.g., Manning’s n, that is adjusted until the model can reproduce available discharge observations at watershed scale. However, the flow resistance measured in plot-scale experiments (1–10 m) often exceeds equivalent roughness coefficients by a factor of 10. This means that the direct use of plot-scale experimental data to parameterize runoff models could cause errors in discharge and runoff velocity predictions. Here, we resolve these differences by deriving an analytic correction factor that relates flow resistance to the equivalent roughness required for models to reproduce experimental velocity and discharge data. This correction factor is tested using rainfall simulator data from 129 experiments performed in the US Southwest covering a wide range of precipitation intensities, soil textures and vegetation types. Use of the correction factor substantially improves model prediction of flow velocity, which is needed for reproducing the timing of flood events and the estimation of erosion.

54 ENVIRONMENTAL SCIENCES↗

Hybrid PDES Simulation of HPC Networks Using Zombie Packets

Although high-fidelity network simulations have proven to be reliable and cost-effective tools to peer into architectural questions for high-performance computing (HPC) networks, they incur a high resource cost. The time spent in simulating a single millisecond of network traffic in the highest detail can take hours, even for static, well-behaved traffic patterns such as uniform random. Surrogate models offer a significant reduction in runtime, yet they cannot serve as complete replacements and should only be used when appropriate. Thus, there is a need for hybrid modeling, where high-fidelity simulation and surrogates run side-by-side. Here, we present a surrogate model for HPC networks in which: packets bypass the network, while the network state is left untouched, i.e., suspended. To bypass the network, we use historical data to estimate the arrival time at which every packet should be scheduled at; to suspend the network, all in-flight packets are scheduled to arrive at their destinations, and are kept in the system to awaken as zombies when switching back to high-fidelity. Speedup for a hybrid model is relative to the proportion of surrogate to high-fidelity. This light-weight surrogate obtained up to 76× speedup. Keeping the zombies in the network showed an increase in the accuracy of the high-fidelity simulation on restart when compared to restarting the network from an empty state.

HPC networks↗

Search for Baryon Number Violation in Top Quark Production and Decay Using Proton-Proton Collisions at $\sqrt{𝑠}$ = 13 TeV

A search is presented for baryon number violating interactions in top quark production and decay. The analysis uses data from proton-proton collisions at a center-of-mass energy of 13 TeV, collected with the CMS detector at the LHC with an integrated luminosity of 138 fb −1 . Candidate events are selected by requiring two oppositely charged leptons (electrons or muons) and exactly one jet identified as originating from a bottom quark. Multivariate discriminants are used to separate the signal from the background. No significant deviation from the standard model prediction is observed. Upper limits are placed on the strength of baryon number violating couplings. For the first time the production of single top quarks via baryon number violating interactions is studied. This allows the search to set the most stringent constraints to date on the branching fraction of the top quark decay to a lepton, an up-type quark (𝑢 or 𝑐), and a down-type quark (𝑑, 𝑠, or 𝑏). The results improve the previous bounds by 3 to 6 orders of magnitude based on the fermion flavor combination of the baryon number violating interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗