Search NASA⌕ Search

SEARCH · Search NASA

Results for “Single photon sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Characterization of a Small-Scale Prototype Detector With Wide Dynamic Range for Time-Resolved High-Energy X-Ray Applications

We present characterization measurements of a fast-framing, wide-dynamic-range x-ray area detector intended for high-energy applications (≥20 keV photons). The MM-PAD-2.1 combines an integrating pixel front-end with a charge-removal mechanism to extend the maximum measurable signal to > 107 20-keV ph/pixel/frame. The charge-removal mechanism is dead-time-less (i.e., incoming signal continues to be integrated by the front-end while charge removal is taking place) up to an incoming photon rate of > 109 20-keV ph/pix/s. A 16×16 pixel prototype was fabricated and characterized using both laboratory and synchrotron x-ray sources, allowing for measurements from single-photon to high-flux conditions. High-flux measurements show linear performance up to ~1010 ph/s in a spot spanning approximately 2×1.5 pixels (FWHM). The onset of temporary radiation damage in the detector was observed during these measurements, manifesting as failure of the digital readout from the detector. These effects were seen to reverse after annealing at 30° C for several hours.

47 OTHER INSTRUMENTATION↗

Some atmospheric scattering considerations relevant to BATSE: A model calculation

The orbiting Burst and Transient Source Experiement (BATSE) will locate gamma ray burst sources by analysis of the relative numbers of photons coming directly from a source and entering its prescribed array of detectors. In order to accurately locate burst sources it is thus necessary to identify and correct for any counts contributed by events other than direct entry by a mainstream photon. An effort is described which estimates the photon numbers which might be scattered into the BATSE detectors from interactions with the Earth atmosphere. A model was developed which yielded analytical expressions for single-scatter photon contributions in terms of source and satellite locations.

Young, John H.↗

An Evaluation of a Passively Cooled Cylindrical Spectrometer Array in Lunar Orbit

This thesis will evaluate a passively cooled cylindrical spectrometer array in lunar orbit characterizing the thermal response in order to provide context for decision-making to scientists and engineers. To provide perspective on thermal issues and controls of space science instruments, a background search of historical lunar missions is provided. Next, a trial science mission is designed and analyzed which brings together the elements of the background search, lunar orbit environment and passive cooling. Finally, the trial science mission analysis results are provided along with the conclusions drawn. Scintillators are materials that when struck by particle radiation, absorb the particle energy which is then reemitted as light in or near the visible range. Nuclear astrophysics utilizes scintillating materials for observation of high-energy photons which are generated by sources such as solar flares, supernovae and neutron stars. SPMs are paired with inorganic scintillators to detect the light emitted which is converted into electronic signals. The signals are captured and analyzed in order to map the number and location of the high-energy sources. The SPM is utilized as it has single photon sensitivity, low voltage requirements and a fast response. SPMs are also compact, relatively inexpensive and allow the usage of lower-cost scintillating materials within the spectrometer. These characteristics permit large-area arrays while lowering cost and power requirements. The ability of a spectrometer to record and identify the interaction of high-energy photons for scientific return is not a trivial matter. Background noise is generated when particles that have not originated from the desired distant source impact the spectrometer. Additionally, thermally induced electrical signals are randomly generated within the SPM even in the absence of light which is referred to as dark current. Overcoming these obstacles requires greater light emittance and energy resolution with reduced dark current. Strong scintillation photon emittance ensures that low energy impacts will produce enough visible photons to be detected by the SPM. Higher energy resolution will ensure that single photon impacts can be distinguished from others of similar wavelength and energy; reduced dark current decreases the generation of random signals not associated with a photon impact. Increasing efficiency in each of these properties in a spectrometer comprised of inorganic scintillators and SPMs requires low temperatures. Low temperature maintenance in a lunar environment presents many unique challenges of its own. Even with the accumulated successes of past missions, the lunar environment remains a thermal challenge for engineers. The lunar orbit thermal environment is driven by radiation from three sources, direct solar radiation, reflected solar radiation from the lunar surface (albedo) and lunar radiation (Clawson 2002). Direct solar radiation values are consistent with those seen in Earth orbit (1325 W/m2) (Clawson 2002). The percentage of solar radiation reflected from the moon is consistently very low with the moon's dark regolith covered surface absorbing nearly 90% of the incident light (Clawson 2002). Yet, it is this absorption that gives the lunar orbit environment one of its most difficult thermal attributes as the absorbed solar radiation is released from the lunar surface as infrared radiation (IR). IR is of a wavelength that is readily absorbed by surfaces designed to function as radiation emitters. It is practical to therefore "choose radiator locations and spacecraft attitude to minimize radiator views to the lunar surface, when possible...pointing the radiator towards the sun to some extent, to minimize its view to the lunar surface, is frequently preferable. (Clawson 2002)" Additionally, the amount of direct solar radiation, lunar IR and albedo an orbiting satellite receives varies from one side of the moon to the other as the moon blocks the sun from view. This environment produces large temperature variations in a satellite's instrumentation, control electronics and propulsion systems which must be understood to characterize operating temperature envelopes.

Waggoner, Jason↗

Supporting Data for "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mössbauer spectroscopy"

Contents of this DOI are data for the research paper "Constraints on magnetism and correlations in RuO2 from lattice dynamics and Mossbauer spectroscopy" by the authors: George Yumnam, et. al. The dataset contains data from inelastic x-ray scattering measurements of RuO2 single crystals performed at the Advanced Photon Source in Argonne National Lab. This dataset also contains data from inelastic neutron scattering experiments of RuO2 powder performed at the ARCS spectrometer at Spallation Neutron Source at ORNL. Supporting theoretical calculations based on density functional theory with r2SCAN and DFT+U methods is also included in this dataset. Please see the README.txt files for more information of the dataset and file contents. For comments and questions, please contact: George Yumnam (yumnamg@ornl.gov) and/or Raphael P Hermann (hermannrp@ornl.gov)

density functional theory↗

Photonic Source for Binary Source Simulations

More than half of the sun-like stars are in binary systems or have companions that hinder the search for planets around them using traditional technologies. There are only 69 FGK dwarfs within ten pc that can harbor true earth analogs. Direct imaging can detect and study the habitability of those targets measuring the chemical composition of the atmosphere, and astrometry can measure the planet's mass. We use Multi-Star Wavefront Control (MSWC), a technique that removes stellar leakage from both stellar components to enable direct imaging of binary systems. Currently, there is a technology demonstration experiment of MSWC for the Roman coronagraph instrument at the High Contrast Imaging Testbeds operated at JPL. One of the challenges for this experiment is to produce a binary source where both stars are incoherent with each other at close physical separation. On the other hand, to measure masses, it is possible to obtain relative astrometry measurements between the binary. The TOLIMAN concept proposes to use a diffractive pupil to calibrate the distortion and detector effects to reach 1uas astrometric accuracy. JPL currently has a laboratory to demonstrate this technology, which faces the same challenge as the MSWC project of producing two incoherent nearby sources. We developed Photonic Chips with multiple waveguides in Silicon Nitride for both projects to create incoherent single sources as close as 15um. In this paper, we present the concept application, the chips design, and the first results.

photonic chips↗

Phase Contrast X‐Ray Imaging of the Collapse of an Engineered Void in Single‐Crystal HMX

Abstract Imaging the collapse of a single void that creates a hot spot initiation site in an otherwise defect‐free explosive is challenging given the spatial and temporal scales involved in explosive systems. This work presents our attempt to examine a single hot spot mode (void collapse) in single‐crystal octahydro‐l,3,5,7‐tetranitro‐l,3,5,7‐tetrazocine (HMX) embedded in Sylgard. The hot spot heating mechanisms involved with pore collapse include adiabatic heating, jetting, and viscoplastic dissipation. Quantifying the dynamics of a pore collapse is a crucial step to understanding which mechanisms dominate during ignition events. Our experiments were conducted with a single‐stage, light‐gas gun at Argonne National Laboratory's Advanced Photon Source, applying the phase contrast imaging technique while collecting high‐speed video. The details of HMX single crystal production, defect (pore) engineering, and sample construction, along with experimental results are presented here. These results demonstrate that detailed collapse dynamics can be obtained from homogeneous, single‐crystal explosives with this approach. Qualitative comparisons are made with simulation data which show good agreement in the transition between a quasi‐symmetric pore collapse and an asymmetric collapse with jetting across the pore as measured with normalized pore area and pore circularity.

42 ENGINEERING↗

DENNIS: a design and analysis tool for dynamic material x-ray diffraction experiments

We present DENNIS (Diffraction Experiment desigN and aNalysiS): a graphical software tool useful for the design and analysis of dynamic x-ray diffraction experiments, such as those performed on the Z Pulsed Power Facility, Thor Pulsed Power Generator, and Dynamic Compression Sector (DCS) of the Advanced Photon Source. DENNIS provides rapid powder and single-crystal diffraction pattern predictions and powder diffraction pattern image integration in three-dimensional geometries. Additional features include crystallographic information file reading, image processing, and synthetic diffraction pattern image generation. We overview the software's capabilities, detail the prediction and integration methodologies, and provide example implementations on Z and DCS experiments.

47 OTHER INSTRUMENTATION↗

NASA Tech Briefs, November 2011

The topics include: 1) Flight Test Results from the Rake Airflow Gage Experiment on the F-15B; 2) Telemetry and Science Data Software System; 3) CropEx Web-Based Agricultural Monitoring and Decision Support; 4) High-Performance Data Analysis Tools for Sun-Earth Connection Missions; 5) Experiment in Onboard Synthetic Aperture Radar Data Processing; 6) Microfabrication of a High-Throughput Nanochannel Delivery/Filtration System; 7) Improved Design and Fabrication of Hydrated-Salt Pills; 8) Monolithic Flexure Pre-Stressed Ultrasonic Horns; 9) Cryogenic Quenching Process for Electronic Part Screening; 10) Broadband Via-Less Microwave Crossover Using Microstrip-CPW Transitions; 11) Wheel-Based Ice Sensors for Road Vehicles; 12) G-DYN Multibody Dynamics Engine; 13) Multibody Simulation Software Testbed for Small-Body Exploration and Sampling; 14) Propulsive Reaction Control System Model; 15) Licklider Transmission Protocol Implementation; 16) Core Recursive Hierarchical Image Segmentation; 17) Two-Stage Centrifugal Fan; 18) Combined Structural and Trajectory Control of Variable-Geometry Planetary Entry Systems; 19) Pressure Regulator With Internal Ejector Circulation Pump, Flow and Pressure Measurement Porting, and Fuel Cell System Integration Options; 20) Temperature-Sensitive Coating Sensor Based on Hematite; 21) Standardization of a Volumetric Displacement Measurement for Two-Body Abrasion Scratch Test Data Analysis; 22) Detection of Carbon Monoxide Using Polymer-Carbon Composite Films; 23) Substituted Quaternary Ammonium Salts Improve Low-Temperature Performance of Double-Layer Capacitors; 24) Sustainably Sourced, Thermally Resistant, Radiation Hard Biopolymer; 25) Integrated Lens Antennas for Multi-Pixel Receivers; 26) 180-GHz Interferometric Imager; 27) Maturation of Structural Health Management Systems for Solid Rocket Motors; 28) Validating Phasing and Geometry of Large Focal Plane Arrays; 29) Transverse Pupil Shifts for Adaptive Optics Non-Common Path Calibration; 30) Qualification of Fiber Optic Cables for Martian Extreme Temperature Environments; 31) Solid-State Spectral Light Source System; 32) Multiple-Event, Single-Photon Counting Imaging Sensor; 33) Surface Modeling to Support Small-Body Spacecraft Exploration and Proximity Operations; and 34) Achieving Exact and Constant Turnaround Ratio in a DDS-Based Coherent Transponder.

Source record↗

Single-photon superradiance in individual caesium lead halide quantum dots

The brightness of an emitter is ultimately described by Fermi’s golden rule, with a radiative rate proportional to its oscillator strength times the local density of photonic states. As the oscillator strength is an intrinsic material property, the quest for ever brighter emission has relied on the local density of photonic states engineering, using dielectric or plasmonic resonators. By contrast, a much less explored avenue is to boost the oscillator strength, and hence the emission rate, using a collective behaviour termed superradiance. Recently, it was proposed that the latter can be realized using the giant oscillator-strength transitions of a weakly confined exciton in a quantum well when its coherent motion extends over many unit cells. Here we demonstrate single-photon superradiance in perovskite quantum dots with a sub-100 picosecond radiative decay time, almost as short as the reported exciton coherence time. The characteristic dependence of radiative rates on the size, composition and temperature of the quantum dot suggests the formation of giant transition dipoles, as confirmed by effective-mass calculations. The results aid in the development of ultrabright, coherent quantum light sources and attest that quantum effects, for example, single-photon emission, persist in nanoparticles ten times larger than the exciton Bohr radius.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

An Algorithm to Calibrate and Correct the Response to Unpolarized Radiation of the X-Ray Polarimeter Onboard IXPE

The Gas Pixel Detector (GPD) is an X-ray polarimeter to fly onboard IXPE and other missions. To correctly measure the source polarization, the response of IXPE’s GPDs to unpolarized radiation has to be calibrated and corrected. In this paper, we describe the way such response is measured with laboratory sources and the algorithm to apply such correction to the observations of celestial sources. The latter allows to correct the response to polarization of single photons, therefore allowing great flexibility in all the subsequent analysis. Our correction approach is tested against both monochromatic and nonmonochromatic laboratory sources and with simulations, finding that it correctly retrieves the polarization up to the statistical limits of the planned IXPE observations.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

The IRAS Bright Galaxy Sample. IV - Complete IRAS observations

Total flux densities, peak flux densities, and spatial extents at 12, 25, 60, and 100 microns are presented for the 330 sources in the IRAS Bright Galaxy Sample. The flux density ratios S sub nu (60 microns)/S sub nu (100 microns) and S sub nu (12 microns)/S sub n (25 microns) are found to correlate with both the infrared luminosity and the ratio of IR to visible flux. The relation between these two flux density ratios is shown to follow that found previously, with different slopes appearing for the warmer and colder galaxies in the sample. The results suggest that single photon heating of small grains (often the dominant source of 12 and 25 micron radiation from galaxies) significantly affects the emission of some galaxies at 60 microns, and that optical depth effects may alter the emergent radiation at 12 and 25 microns.

Soifer, B. T.↗

Compact single-shot soft X-ray photon spectrometer for free-electron laser diagnostics

The photon spectrum from free-electron laser (FEL) light sources offers valuable information in time-resolved experiments and machine optimization in the spectral and temporal domains. We have developed a compact single-shot photon spectrometer to diagnose soft X-ray spectra. The spectrometer consists of an array of off-axis Fresnel zone plates (FZP) that act as transmission-imaging gratings, a Ce:YAG scintillator, and a microscope objective to image the scintillation target onto a two-dimensional imaging detector. This spectrometer operates in segmented energy ranges which covers tens of electronvolts for each absorption edge associated with several atomic constituents: carbon, nitrogen, oxygen, and neon. The spectrometer’s performance is demonstrated at a repetition rate of 120 Hz, but our detection scheme can be easily extended to 200 kHz spectral collection by employing a fast complementary metal oxide semiconductor (CMOS) line-scan camera to detect the light from the scintillator. This compact photon spectrometer provides an opportunity for monitoring the spectrum downstream of an endstation in a limited space environment with sub-electronvolt energy resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Heterodyne spectrometer sensitivity limit for quantum networking

We report optical heterodyne detection-based spectrometers are attractive due to their relatively simple construction and ultrahigh resolution. Here we demonstrate a proof-of-principle single-mode optical-fiber-based heterodyne spectrometer that has picometer resolution and quantum-limited sensitivity around 1550 nm. Moreover, we report a generalized quantum limit of detecting broadband multispectral-temporal-mode light using heterodyne detection, which provides a sensitivity limit on a heterodyne detection-based optical spectrometer. We then compare this sensitivity limit to several spectrometer types and dim light sources of interest such as spontaneous parametric downconversion, Raman scattering, and spontaneous four-wave mixing. We calculate that the heterodyne spectrometer is significantly less sensitive than a single-photon detector and is unable to detect these dim light sources, except for the brightest and narrowest-bandwidth examples.

47 OTHER INSTRUMENTATION↗

Single-photon absorption and emission from a natural photosynthetic complex

Photosynthesis is generally assumed to be initiated by a single photon from the Sun, which, as a weak light source, delivers at most a few tens of photons per nanometre squared per second within a chlorophyll absorption band1. Yet much experimental and theoretical work over the past 40 years has explored the events during photosynthesis subsequent to absorption of light from intense, ultrashort laser pulses. Here, we use single photons to excite under ambient conditions the light-harvesting 2 (LH2) complex of the purple bacterium Rhodobacter sphaeroides, comprising B800 and B850 rings that contain 9 and 18 bacteriochlorophyll molecules, respectively. Excitation of the B800 ring leads to electronic energy transfer to the B850 ring in approximately 0.7 ps, followed by rapid B850-to-B850 energy transfer on an approximately 100-fs timescale and light emission at 850–875 nm. Using a heralded single photon source20,21 along with coincidence counting, we establish time correlation functions for B800 excitation and B850 fluorescence emission and demonstrate that both events involve single photons. We also find that the probability distribution of the number of heralds per detected fluorescence photon supports the view that a single photon can upon absorption drive the subsequent energy transfer and fluorescence emission and hence, by extension, the primary charge separation of photosynthesis. An analytical stochastic model and a Monte Carlo numerical model capture the data, further confirming that absorption of single photons is correlated with emission of single photons in a natural light-harvesting complex.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Challenges of Measuring Methane from Space with a Lidar

The global and regional quantification of methane fluxes and identification of its sources and sinks has been highlighted as one of the goals of the NASA 2017 Earth Science Decadal Survey. Detecting methane from space and airborne platforms with an active (laser) remote sensing instrument presents several unique technology and measurement challenges. The instrument must have a single frequency, narrow-linewidth light source, and photon-sensitive detector at the right spectral region to make continuous measurements from orbit, day and night, all seasons and at all latitudes. It must have a high signal to noise ratio and must be relatively immune to biases from aerosol/cloud scattering, spectroscopic and meteorological data uncertainties, and instrument systematic errors. At Goddard Space Flight Center (GSFC), in collaboration with industry, we have developed an airborne instrument to measure methane. Our instrument is a nadir-viewing lidar that uses Integrated Path Differential Absorption (IPDA), to measure methane near 1.65 µm. We sample the absorption line using multiple wavelengths from a narrow linewidth laser source and a sensitive photodetector. This measurement approach provides maximum information content about the CH4 column, and minimizes biases in the XCH4 retrieval. In this paper, we will review our progress to date and discuss the technology challenges, options and tradeoffs to measure methane from space and airborne platforms.

airborne instruments↗

Near L-edge Single and Multiple Photoionization of Doubly Charged Iron Ions

Using the photon-ion merged-beams technique at a synchrotron light source, we have measured relative cross sections for single and up to five-fold photoionization of Fe 2+ ions in the energy range of 690-920 eV. This range contains thresholds and resonances associated with ionization and excitation of 2p and 2s electrons. Calculations were performed to simulate the total absorption spectra. The theoretical results show very good agreement with the experimental data, if overall energy shifts of up to 2.5 eV are applied to the calculated resonance positions and assumptions are made about the initial experimental population of the various levels of the Fe 2+ ([Ar]3d 6 ) ground configuration. Furthermore, we performed extensive calculations of the Auger cascades that result when an electron is removed from the 2p subshell of Fe 2+ . These computations lead to a better agreement with the measured product-charge-state distributions as compared to earlier work. We conclude that the L-shell absorption features of low-charged iron ions are useful for identifying gas-phase iron in the interstellar medium and for discriminating against the various forms of condensed-phase iron bound to composite interstellar dust grains.

79 ASTRONOMY AND ASTROPHYSICS↗