Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Arrays”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

DOE Plasma Science Center - Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems (Final Report DE-SC0001939)

Low temperature plasmas (LTPs) are the plasmas of electron-volt (eV) physics and eV technologies. LTPs have characteristic electron temperatures of a few eV and fractional ionizations that are typically small. Since LTPs have electron temperatures commensurate with the threshold energies of excited states in neutral atoms and molecules, power transfer from electrons to these atoms and molecules efficiently produces activated species (e.g., radicals, excited states, photons). Acceleration of ions in the sheaths of LTPs to energies of tens to hundreds of eV enable activation of surface modifying processes – sputtering, etching, deposition. With such properties, LTPs are often and beneficially used in technological devices, ranging from etching and deposition in microelectronics and solar cell fabrication, to hardening of surgical instruments. LTPs harbor fundamental science issues that are intellectually challenging and rewarding. At the same time, there are enormous societal benefits that are enabled by LTPs. The entire present-day and future information technology infrastructure owes its very existence to LTPs. Renewable energy sources, such as solar cell arrays, could not be economically produced in the absence of deposition and etching by LTPs. In acknowledgment of the importance of LTPs, the DOE Office of Fusion Energy Sciences supported the Plasma Science Center for Predictive Control of Plasma Kinetics: Multi-Phase and Bounded Systems from August 2009 to July 2021, consisting of an initial 5-year grant, 3 funded extensions and 2 no-cost extensions. This is the final report of the Center in which the productivity of the Center is discussed in terms of publications, impact and personnel. High-lights of the research performed in the Center are provided.

36 MATERIALS SCIENCE↗

Grassland carbon-water cycling is minimally impacted by a photovoltaic array

Agrivoltaic systems, whereby photovoltaic arrays are co-located with crop or forage production, can alleviate the tension between expanding solar development and loss of agricultural land. However, the ecological ramifications of these arrays are poorly known. We used field measurements and a plant hydraulic model to quantify carbon-water cycling in a semi-arid C 3 perennial grassland growing beneath a single-axis tracking solar array in Colorado, USA. Although the agrivoltaic array reduced light availability by 38%, net photosynthesis and aboveground net primary productivity were reduced by only 6–7% while evapotranspiration decreased by 1.3%. The minimal changes in carbon-water cycling occurred largely because plant photosynthetic traits underneath the panels changed to take advantage of the dynamic shading environment. Our results indicate that agrivoltaic systems can serve as a scalable way to expand solar energy production while maintaining ecosystem function in managed grasslands, especially in climates where water is more limiting than light.

14 SOLAR ENERGY↗

Overview of Solar Panel Recycling for Indigenous Communities

In recent years, Native tribes across the country have embraced solar energy to power their communities. However, in approximately 25-30 years after installation, the solar panels will enter end-of-life (EOL) status, meaning that they will begin to operate less efficiently than upon initial implementation. At this point, tribes can determine the outcome: they can continue to operate the array, or they can dispose of the panels. Recycling is an option that promotes the use of high-value recyclable materials in solar panels in the circular economy. There are several companies across the US that offer recycling of solar panels, but at various costs. It is important that a hazardous waste expert makes an initial assessment of the solar array to identify any solar panels that cannot be recycled. Currently, recycling solar panels is not cost-effective or environmentally sustainable, but significant research into improving the cost and carbon footprint is ongoing.

14 SOLAR ENERGY↗

Increased panel height enhances cooling for photovoltaic solar farms

We report solar photovoltaic (PV) systems suffer substantial efficiency loss due to environmental and internal heating. However, increasing the canopy height of these systems promotes surface heat transfer and boosts production. This work represents the first wind tunnel experiments to explore this concept in terms of array flow behavior and relative convective heat transfer, comparing model solar arrays of varied height arrangements - a nominal height, extended height, and a staggered height configuration. Analyses of surface thermocouple data show average Nusselt number (Nu) to increase with array elevation, where panel convection at double height improved up to 1.88 times that of the nominal case. This behavior is an effect of sub-array entrainment of high velocity flow and panel interactions as evidenced through flow statistics and mean kinetic energy budgets on particle image velocimetry (PIV) data. The staggered height arrangement encourages faster sub-panel flow than in the nominal array. Despite sub-array blockage due to the lower panel interaction, heat shedding at panel surfaces promotes improvements on over 1.3 times that of the nominal height case.

14 SOLAR ENERGY↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Navy Ratchets Up Resilience Through Agency/Utility Collaboration

The Naval Construction Battalion Center (NCBC) in Gulfport, Mississippi, and Mississippi Power Company (MPC) have integrated a 15-acre solar photovoltaic (PV) array, battery storage, and backup generation with an innovative microgrid. The Navy and utility teams are helping ensure mission readiness at NCBC while increasing renewable energy generation on the grid in MPC's service area. The NCBC/MPC resilience effort will allow the base to more effectively deploy disaster recovery activities in the event of a grid outage.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Nonlinear Direct Power Controller for a Three-Phase Grid-Connected Inverter with Online Parameter Update for PV Application

This work proposes a nonlinear direct power controller for a three-phase grid-connected inverter for photovoltaic application. Grid-connected converters for solar applications require advanced control architectures to ensure optimal operation and extraction of maximum power from the photovoltaic arrays. Therefore, to ensure this, a nonlinear power controller architecture has been proposed to extract the maximum power from the solar arrays and to achieve the most optimal operation. To further improve the performance, a parameter update scheme has been utilized which is based on model reference adaptive system. The latter helps to accomplish not only good dynamic response but also excellent tracking performance. The overall control come estimation architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

direct power control↗

Viewing convection as a solar farm phenomenon broadens modern power predictions for solar photovoltaics

We report heat mitigation for large-scale solar photovoltaic (PV) arrays is crucial to extend lifetime and energy harvesting capacity. PV module temperature is dependent on site-specific farm geometry, yet common predictions consider panel-scale and environmental factors only. Here, we characterize convective cooling in diverse PV array designs, capturing combined effects of spatial and atmospheric variation on panel temperature and production. Parameters, including row spacing, panel inclination, module height, and wind velocity, are explored through wind tunnel experiments, high-resolution numerical simulations, and operating field data. A length scale based on fractal lacunarity encapsulates all aspects of arrangement (angle, height, etc.) in a single value. When applied to the Reynolds number Re within the canonical Nusselt number heat transfer correlation, lacunarity reveals a relationship between convection and farm-specific geometry. This correlation can be applied to existing and forthcoming array designs to optimize convective cooling, ultimately increasing production and PV cell life.

14 SOLAR ENERGY↗

A Dual-Mode Hybrid System Combining Solar Thermal With Pumped Thermal Energy Storage

A hybrid system that delivers renewable electricity generation and electricity storage capabilities is introduced. This dual-mode hybrid system is based on Pumped Thermal Energy Storage (PTES) which uses a heat pump to convert electricity into thermal energy that is trans-ferred to silica particles which are stored in concrete silos. The stored heat is later converted back to electricity in a heat engine. The heat pump and heat engine use a closed Joule-Brayton cycle and fluidized bed heat exchangers. If the PTES system is co-located with an array of concentrating solar mirrors and a particle receiver, then the silica particles may also be heated up by the concentrating solar power (CSP) system. The PTES heat engine may also be used to convert the stored solar heat into electricity, thereby sharing this system between the PTES and CSP systems and reducing costs. However, this requires careful management of the heat engine off-design parameters. A thermodynamic model is used to evaluate the performance of the dual mode PTES-CSP hybrid system. The model accounts for turbomachinery effi-ciency, and approach temperature and pressure loss in heat exchangers, as well as other sources of inefficiency, such as motor-generator losses, and air fan power. The hybrid system also requires the evaluation of the turbomachinery efficiency and pressure ratio at off-design conditions since the CSP system operates over different temperature ratios than the Carnot Battery. Several design variables and design modifications are investigated, such as pressure ratios and maximum temperatures.

14 SOLAR ENERGY↗

Toward Solar Photovoltaic Storm Resilience: Learning from Hurricane Loss and Rebuilding Better

This case study report focuses on the rebuild of a 469 kW ground array located at the Almeric L. Christian Federal Building in Christiansted, St. Croix, in the U.S. Virgin Islands. The General Service Administration (GSA) suffered extensive damage to its solar arrays located throughout the Caribbean from Hurricanes Irma and Maria in 2017. While the damage that occurred was unfortunate, there are excellent lessons learned that can be gained and utilized on new systems. The St. Croix site provides a particularly high-value opportunity for lessons learned due to the innovative rebuilding process utilized by GSA managers and the in-depth analysis performed by the project engineers.

14 SOLAR ENERGY↗

Modeling Wind in Agrivoltaics and its Impact on Eddy Covariance Flux Measurements

Silicon Ranch is conducting a research study at their 138MW Bancroft Station agrivoltaics site, the largest agrivoltaics research array in the US, in which they are using an eddy covariance flux tower to measure the carbon budget. They are interested in finding out if the presence of the panels changes the effectiveness of these measurements. To investigate this topic, NLR performed numerical simulations of wind through the agrivoltaic array to identify under what environmental conditions (wind speed, wind direction, temperatures) and panel tilt angles the mean wind speeds at the measurement heights are significantly altered by the presence of the solar panels. NLR adapted and used the PVade simulation tool [1] to model wind in Silicon Ranch's agrivoltaic array and found that at the height of the flux tower (6m), the wind speed measured is not significantly altered by the presence of solar panels. The percent difference is less than 4% and is generally greatest during daytime conditions at higher wind speeds and perpendicular wind direction. Closer to the ground, the flow is significantly altered (wind speeds are reduced) by the presence of solar panels and the percent difference increases in strong winds. The work confirmed that eddy covariance flux towers can be used within the context of a solar array field.

14 SOLAR ENERGY↗

Scaler Rates from the Pierre Auger Observatory: A New Proxy of Solar Activity

The modulation of low-energy galactic cosmic rays reflects interplanetary magnetic field variations and can provide useful information on solar activity. An array of ground-surface detectors can reveal the secondary particles, which originate from the interaction of cosmic rays with the atmosphere. In this work, we present an investigation of the low-threshold rate (scaler) time series recorded in 16 yr of operation by the Pierre Auger Observatory surface detectors in Malargüe, Argentina. Through an advanced spectral analysis, we detected highly statistically significant variations in the time series with periods ranging from the decadal to the daily scale. We investigate their origin, revealing a direct connection with solar variability. Thanks to their intrinsic very low noise level, the Auger scalers allow a thorough and detailed investigation of the galactic cosmic-ray flux variations in the heliosphere at different timescales and can, therefore, be considered a new proxy of solar variability.

79 ASTRONOMY AND ASTROPHYSICS↗

Building Resiliency into Grand Canyon West Micro-Grid

The objective of the project was to improve the resilience of the non-regional-grid-connected electrical generation system at Grand Canyon West (GCW) to withstand short-term disruptions and rising energy costs by installing an 885-kW solar photovoltaic (PV) array and 750-kilowatts (kW)/2,145-kilowatt hour (kWh) battery energy storage system (BESS). The system is designed to provide 50% of the annual energy needed for the essential facilities at GCW, supplementing the existing diesel generators, saving approximately $\$$463,339 per year and an estimated $\$$11,583,475 over the 25-year life of the system. The project aligns with the Tribe’s conservation ethic and self-determination in the area of energy development.

14 SOLAR ENERGY↗

PV-BESS DC-Series Integration for Regulated DC Systems

DC-series integration introduces a novel approach to seamlessly integrate a solar photovoltaic (PV) array and a battery energy storage (BES) in series. This system, referred to as the PV-integrated battery energy storage system—dc series (PVBESS-DCS), simplifies integration and enhances power density by leveraging the inherent voltage-source characteristics of batteries and adopting the concept of partial power processing. However, addressing voltage variations of a PV array and a BES under different operational conditions remains a challenge to apply the PVBESS-DCS to a regulated dc system, where the dc-bus voltage is fixed. This article proposes a PVBESS-DCS solution tailored for regulated dc systems. Within this framework, we present a controllable series voltage source compensating for the voltage differences between the PV and BES sources and the dc bus. Thus, the system can perform PV maximum power point tracking and curtailment control while charging and discharging BES and connected to a regulated dc bus. Additionally, we present a single-stage multiport partial power processing dc–dc converter designed for the proposed PVBESS-DCS. It utilizes a triple active bridge dc–dc converter topology. Finally, this article presents operating principles, control strategies, simulation results, and experimental findings of the proposed PVBESS-DCS for regulated dc systems.

25 ENERGY STORAGE↗

Remote Alaska Communities Energy Efficiency Competition: Energy Efficiency for the Gem of the Yukon (Final Report)

Over the past decade, the City of Ruby has been proactive in working to reduce cost and energy use in the community. Ruby (Tl’aa’ologhe) is a remote city in Alaska located on the south bank of the Yukon River near the Kilbuck-Kuskokwim Mountains, about 50 air miles east of Galena and 230 air miles west of Fairbanks. As of 2019, the community has a population of over 150 people and most of Ruby’s residents are Koyukon Athabascan. Ruby has a long history of promoting local efficiency and clean energy in an effort to become more sustainable. Between 2007-2010, the community hosted Alaska’s first demonstration of an in-river hydrokinetic test project, sponsored by the Yukon River Inter-Tribal Watershed Council. In 2011, a 5kW solar photo-voltaic (PV) array was installed by the Interior Regional Housing Authority. In 2012, the community had a new power plant constructed by the Alaska Energy Authority that supplies waste heat to the washeteria, clinic and public safety garage, saving the community more than 4,000 gallons of heating fuel per year. The clinic, constructed by the Tanana Chiefs Conference, is one of the most energy efficient buildings in the interior and utilizes new building efficiency standards that were passed by the tribes. It has a 5kW solar PV array that provides energy into the local electric grid and offsets approximately 20% of the annual energy use. Building on this legacy, the City of Ruby entered into Department of Energy’s (DOE’s) Remote Alaska Communities Energy Efficiency Competition (RACEE) in 2016, pledging to reduce per-capita energy use 15% by 2020. During the second phase of the competition, 13 communities including Ruby were provided funding for tailored technical assistance to measure energy use and create energy efficiency plans.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

PVade (PV Aerodynamic Design Engineering) [SWR-23-49]

PV Aerodynamic Design Engineering (PVade) is an open-source fluid-structure interaction (FSI) solver which can accurately simulate wind loads and aerodynamic stability in solar-tracking PV arrays. PVade’s pressure profiles and inertial load time series can be used as inputs into mechanical module models to study degradation mechanisms including cracking of cells, weathering of cracked cells, and glass breakage. This software enables PV plant owners to predict optimal high-wind stow strategies under a variety of weather and site conditions.

Young, Ethan↗

Planning for the storm: Considering renewable energy for critical infrastructure resilience

This study uses the renewable energy optimization model to assess three critical facilities in North Carolina. Techno-economic results were then compared to analyses completed for critical facilities in California and New York to assess energy system cost effectiveness. Though solar photovoltaic (PV) arrays are cost-effective across each of the three North Carolina facilities, adopting battery storage to enable PV to operate with existing diesel generators in a hybrid energy system reduces the economic value of the system. This is in contrast to more economically viable systems in California and New York. All of these systems also offer unquantified resilience benefits by extending operation from hours to weeks across the facilities. If decision makers were able to value the resilience benefits offered by each system or utility rate structures were changed to incentivize battery storage during normal operations, it would impact these assessments. Even so, this analysis provides decision makers a key set of cost benchmarks when considering how they might improve resilience at their critical operations.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗