Search NASA⌕ Search

SEARCH · Search NASA

Results for “Solar Plus Storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Form Follows Function (F3): A framework for community-based energy resilience planning in the Midwest

This is the final technical report for the Form Follows Function (F3) grant project led by the City of Duluth, MN. F3 was an innovative two-year initiative that created a replicable, human-centered energy resilience planning process specifically designed for smaller, cold-climate communities in the Midwest. F3 demonstrated both systems-level government planning and community-based research techniques to inform renewable investments and community preparedness strategies.

14 SOLAR ENERGY↗

Q1 2023 U.S. Solar Photovoltaic System and Energy Storage Cost Benchmarks With Minimum Sustainable Price Analysis Data File

The U.S. Department of Energy's (DOE's) Solar Energy Technologies Office (SETO) aims to accelerate the advancement and deployment of solar technology in support of an equitable transition to a decarbonized economy no later than 2050, starting with a decarbonized power sector by 2035. Its approach to achieving this goal includes driving innovations in technology, hardware, and soft cost reductions to make solar affordable and accessible for all. As part of this effort, SETO must track solar cost trends so it can focus its research and development (R&D) on the highest-impact activities. The benchmarks in this report are bottom-up cost estimates of all major inputs to PV and energy storage system installations. Bottom-up costs are based on national averages and do not necessarily represent typical costs in all local markets. Like last year's report, this year's report includes two distinct sets of benchmarks: minimum sustainable price (MSP) benchmarks and modeled market price (MMP) benchmarks. MSP benchmarks can be interpreted as the minimum price a company needs to charge to remain financially solvent in the long term based on the minimum sustainable prices of all inputs including minimum sustainable profit margins. MMP benchmarks can be interpreted as the actual cash sales price a company charges in the given benchmark period. These simplified estimates are useful for tracking technological progress, but they do not reflect all experiences. In fact, no individual estimate under any approach can reflect the diversity of the PV and storage manufacturing and installation industries.

14 SOLAR ENERGY↗

Preliminary Hyde Memorial State Park Modular Pumped Hydro Energy Storage Sizing Study

Hyde Memorial State Park has lost grid supplied power and has been running on a diesel generator for some time now. The powerline that feeds the park is a state owned, 5 mile underground extension from the PNM service connection point. The line has decayed over the past 30 plus years and due to the location (much of it running under the road) the cost of repair and the logistics of closing the road are not good options. In June 2019 through a state contractor, the State of New Mexico Energy, Minerals and Natural Resources Department completed a renewable energy microgrid feasibility study to see if it was technically and economically feasible to operate the park without future grid power. The study looked at solar plus battery storage and a propane generator as a possible option. New Mexico State Parks Division has indicated their wish to move forward with the microgrid project which will now go out to one of the state’s energy services performance contractors. The contractor will have to finalize the feasibility study and develop a complete list of construction costs. Given, the lack of long-term O&M data on the battery, as part of the next phase of the project the State of New Mexico Energy, Minerals and Natural Resources Department asked Los Alamos National Laboratory to preliminary examine the potential for pumped hydro as an alternative to batteries.

13 HYDRO ENERGY↗

Solar + Storage Synergies for Managing Commercial-Customer Demand Charges

We study the synergies between behind-the-meter solar and storage in reducing commercial-customer demand charges. This follows two previous studies that examined demand charge savings for stand-alone solar in both the residential and commercial sectors. In this study we show that solar and storage show consistent synergies for demand charge management, that the magnitude of reductions are highly customer-specific, and that the magnitude of savings is influenced by the design of the electricity tariff.

14 SOLAR ENERGY↗

REopt ® Lite Overview - Resilience Analysis: Clear Sky Tampa Bay [Slides]

Through the Solar Energy Innovation Network (SEIN), the Clear Sky Tampa Bay team, led by the Tampa Bay Regional Planning Council (TBRPC), developed a toolkit to help local governments prioritize sites for solar photovoltaics (PV) and battery energy storage in the context of resilience and emergency management. At a high level, the Clear Sky Tampa Bay process involves: (1) Identifying sites based on community resilience needs and priorities ("Where do we need a resilient energy solution?"); (2) Screening and prioritizing sites for solar PV and storage suitability based on site conditions and other factors; and (3) Using REopt Lite to screen down-selected facilities to prioritize sites based on resilience project economics. This slide deck focuses on Step 3 above, and provides a general overview of REopt Lite and suggestions and examples tailored to the Clear Sky Tampa Bay team about how to use REopt Lite for additional analysis.

14 SOLAR ENERGY↗

Assessing uncertainty in the timing of energy use during cost-optimal distributed energy technology selection and sizing

This paper empirically derives uncertainty ranges in cost-optimal solar PV and storage sizing by comparing results from the REopt Lite optimization platform from metered data and a set of simulated Department of Energy Commercial Reference Building (CRB) profiles at 65 sites. We find load profile shape alone does not explain a site’s optimal configurations (i.e., PV, Storage, PV and Storage, No System). Still, load profile shape does introduce uncertainty to optimal PV and storage capacities. Across all cases where PV is part of an optimal configuration, we find the average ratio of power capacities derived from metered loads to capacities derived from CRB profiles to be 0.97 (and as high as 1463), where 1 would be a perfect match in system size. For storage, the ratio is 1.6 (and as high as 42). We also assess how, in the absence of complete metered data, a CRB profile can be selected that would be expected to yield the most similar solar PV and storage capacities. From those metrics that can be available from billing data (i.e., peak demand, monthly load totals), we find that uncertainty is most reduced by selecting the CRB’s with an annual peak occurring at the most similar time, or those with the lowest average root mean square error (RMSE) among monthly peak loads. This research can help improve the implementation and interpretation of results derived from simulated load profiles and is an important next step in advancing smart grid solutions.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A Reliable, Cost-Effective Transformerless Medium-Voltage Inverter for Grid Integration of Combined Solar and Energy Storage

The goal of this project is to utilize an innovative holistic power electronic inverter design approach, which can leverage best-in-class silicon carbide (SiC) power modules, novel multi-level power electronic circuits, high frequency transformers, switching sequence based control and co-designed electro-thermal management methods, to realize a 300 kW transformerless medium-voltage (MV) inverter system. The system cost of the inverter is considered as a primary design objective alongside high power density, efficiency, low electromagnetic interference (EMI) and long lifespan. This design-oriented research activity, especially the proposed multi-objective optimization approach, will have broad impacts in holistic power electronic system design methods and in technologies that can be commercialized into a wide variety of wide bandgap power electronic applications.

14 SOLAR ENERGY↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncer- tainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

SolarAPP+ Performance Review: Final Technical Report

The National Renewable Energy Laboratory (NREL) and its project partners have developed the novel Solar Automated Permit Processing plus (SolarAPP+) software platform that provides a flexible, web-based PV-permitting tool for residential systems that can be integrated with existing and complementary software platforms. The main objective of this research is to analyze the implementation of SolarAPP+. Analysis was conducted by identifying the benefits, tradeoffs, and overall performance of SolarAPP+, including achieving its goals of delivering automated, code compliant systems, influencing permitting cycle times, and improving application submittals and/or inspection performance. The NREL team published the results of this analysis in annual SolarAPP+ Performance Review technical reports.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Updating PV and Battery Bill Savings Calculations for Net Billing: New Best Practices for Input Data and Uncertainty

Jurisdictions are increasingly adopting compensation structures for distributed PV and PV-battery systems that price exported energy lower than energy consumed onsite (net billing rates). Standard methods for calculating the bill savings from PV and PV-battery systems were developed for net metering structures, and applying these same methods to net billing structures (such as using Typical Meteorological Year weather with actual year load) introduces bias errors that underestimate PV-battery system bill savings by between 1.5\% and 9\%, depending on the utility rate. We assess the magnitude of these errors and compare them to other sources of uncertainty when estimating the bill savings from PV and PV-battery systems under more complex utility rates.

14 SOLAR ENERGY↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Heuristic Dispatch Based on Price Signals for Behind-the-Meter PV-Battery Systems in the System Advisor Model: Preprint

The economic potential of a behind-the-meter (BTM) PV-battery system depends greatly on how the battery is dispatched. Different utility rates, system sizes, generation and load profiles can all require different dispatch strategies. This paper presents price signals dispatch, a new algorithm for automated economic dispatch of BTM PV-battery systems, which utilizes 24-hour PV and load forecasts, degradation data, and utility rates. The algorithm is integrated with the System Advisor Model (SAM) tool and is tested with a nonlinear generic electrochemical battery model. Price signals dispatch outperforms SAM’s existing algorithms in cases requiring a balance between demand charge management and energy arbitrage, and in cases where battery degradation imposes a significant cost.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Impacts of Dispatch Strategies and Forecast Errors on the Economics of Behind-the-Meter PV-Battery Systems: Preprint

To assess the economic value of batteries in hybrid PV-battery systems, one must create a dispatch profile for the battery. Many analyses of battery value assume perfect forecasts of PV generation and load, determining an upper limit on the value of the battery. Prior work that accounts for forecast uncertainty often does so in the context of a single dispatch algorithm, which does not provide a baseline for comparison. Furthermore, when multiple dispatch algorithms are assessed with uncertainty, the benefits considered are for diesel generation in a microgrid, not retail rate savings. This work addresses the gaps in the literature by comparing the performance of both heuristic and optimal dispatch algorithms for retail rate savings under forecast uncertainty, and provides comparisons of the robustness of these algorithms and their associated estimates of economic value. We find that using a perfect forecast can overestimate the value of hybrid PV-battery systems between 1% and 8% compared to the reality of using a day-ahead forecast, depending on the dispatch algorithm used. Thus, accounting for forecast uncertainty in system design and analysis will significantly improve the accuracy of modeled system values.

batteries↗

Recent and Planned Improvements to the System Advisor Model (SAM)

This talk will focus on recent and planned modeling improvements to the NREL System Advisor ModelTM (SAM), including PV hourly clipping correction, expanded geographic scope of PVWatts including Ukraine, additional options for hybrids, and enhanced PySAM and GUI interoperability. Additional topics will also include: bifacial modeling features including irradiance on the ground for agrivoltaics, PV uncertainty simulation features, and integrations with other NREL and industry tools.

battery↗

Minneapolis American Indian Center Solar + Battery Resilience Hub

To meet south Minneapolis, Minnesota's clean energy goals, the community exploring opportunities to transition Minneapolis American Indian Center (MAIC) into a resilience hub to provide critical community services during power outages, including shelter and warmth or cooling, continued food distribution services, and more. The National Renewable Energy Laboratory, through the U.S. Department of Energy's Communities LEAP (Local Energy Action Program) pilot, worked with MAIC to quantify the costs and benefits of installing stand-alone solar photovoltaics (PV) and PV paired with battery systems to reduce energy costs, avoid emissions, and improve resilience.

BESS↗

Recent and Planned Improvements to the System Advisor Model (SAM)

This talk will focus on recent and planned modeling improvements to the NREL System Advisor ModelTM (SAM), with recently released features including PV hourly clipping correction, expanded geographic scope of SAM's NSRDB interface to Europe and Africa, and additional options for hybrids. Upcoming improvements include a case comparison feature, improved visualizations, and extensions of PVWatts for battery modeling and utility rate calculations.

batteries↗

Considerations for Implementing PV Plus Storage Systems at Federal Buildings and Campuses

Federal agencies have a long history of using solar photovoltaics and battery storage (PV plus storage) systems at remote sites where the technologies can offset costly diesel fuel. However, recent declines in lithium-ion battery costs, along with changes in net metering policies and utility rate structures, are opening up opportunities for PV plus storage to be deployed cost-effectively at grid-connected sites.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗