Search NASA⌕ Search

SEARCH · Search NASA

Results for “Source code (Computer science)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

WE-D-204-06: An Open Source ImageJ CatPhan Analysis Tool

Purpose: The CatPhan is a popular QA device for assessing CT image quality. There are a number of software options which perform analysis of the CatPhan. However, there is often little ability for the user to adjust the analysis if it isn’t running properly, and these are all expensive options. An open source tool is an effective solution. Methods: To use the software, the user imports the CT as an image sequence in ImageJ. The user then scrolls to the slice with the lateral dots. The user then runs the plugin. If tolerance constraints are not already created, the user is prompted to enter them or to use generic tolerances. Upon completion of the analysis, the plugin calls pdfLaTex to compile the pdf report. There is a csv version of the report as well. A log of the results from all CatPhan scans is kept as a csv file. The user can use this to baseline the machine. Results: The tool is capable of detecting the orientation of the phantom. If the CatPhan was scanned backwards, one can simply flip the stack of images horizontally and proceed with the analysis. The analysis includes Sensitometry (estimating the effective beam energy), HU values and linearity, Low Contrast Visibility (using LDPE & Polystyrene), Contrast Scale, Geometric Accuracy, Slice Thickness Accuracy, Spatial resolution (giving the MTF using the line pairs as well as the point spread function), CNR, Low Contrast Detectability (including the raw data), Uniformity (including the Cupping Effect). Conclusion: This is a robust tool that analyzes more components of the CatPhan than other software options (with the exception of ImageOwl). It produces an elegant pdf and keeps a log of analyses for long-term tracking of the system. Because it is open source, users are able to customize any component of it.

60 APPLIED LIFE SCIENCES↗

SU-E-J-45: The Correlation Between CBCT Flat Panel Misalignment and 3D Image Guidance Accuracy

Purpose To simulate the impact of CBCT flat panel misalignment on the image quality, the calculated correction vectors in 3D image guided proton therapy and to determine if these calibration errors can be caught in our QA process. Methods The X-ray source and detector geometrical calibration (flexmap) file of the CBCT system in the AdaPTinsight software (IBA proton therapy) was edited to induce known changes in the rotational and translational calibrations of the imaging panel. Translations of up to ±10 mm in the x, y and z directions (see supplemental) and rotational errors of up to ±3° were induced. The calibration files were then used to reconstruct the CBCT image of a pancreatic patient and CatPhan phantom. Correction vectors were calculated for the patient using the software’s auto match system and compared to baseline values. The CatPhan CBCT images were used for quantitative evaluation of image quality for each type of induced error. Results Translations of 1 to 3 mm in the x and y calibration resulted in corresponding correction vector errors of equal magnitude. Similar 10mm shifts were seen in the y-direction; however, in the x-direction, the image quality was too degraded for a match. These translational errors can be identified through differences in isocenter from orthogonal kV images taken during routine QA. Errors in the z-direction had no effect on the correction vector and image quality.Rotations of the imaging panel calibration resulted in corresponding correction vector rotations of the patient images. These rotations also resulted in degraded image quality which can be identified through quantitative image quality metrics. Conclusion Misalignment of CBCT geometry can lead to incorrect translational and rotational patient correction vectors. These errors can be identified through QA of the imaging isocenter as compared to orthogonal images combined with monitoring of CBCT image quality.

60 APPLIED LIFE SCIENCES↗

Combining protein sequences and structures with transformers and equivariant graph neural networks to predict protein function

Abstract Motivation Millions of protein sequences have been generated by numerous genome and transcriptome sequencing projects. However, experimentally determining the function of the proteins is still a time consuming, low-throughput, and expensive process, leading to a large protein sequence-function gap. Therefore, it is important to develop computational methods to accurately predict protein function to fill the gap. Even though many methods have been developed to use protein sequences as input to predict function, much fewer methods leverage protein structures in protein function prediction because there was lack of accurate protein structures for most proteins until recently. Results We developed TransFun—a method using a transformer-based protein language model and 3D-equivariant graph neural networks to distill information from both protein sequences and structures to predict protein function. It extracts feature embeddings from protein sequences using a pre-trained protein language model (ESM) via transfer learning and combines them with 3D structures of proteins predicted by AlphaFold2 through equivariant graph neural networks. Benchmarked on the CAFA3 test dataset and a new test dataset, TransFun outperforms several state-of-the-art methods, indicating that the language model and 3D-equivariant graph neural networks are effective methods to leverage protein sequences and structures to improve protein function prediction. Combining TransFun predictions and sequence similarity-based predictions can further increase prediction accuracy. Availability and implementation The source code of TransFun is available at https://github.com/jianlin-cheng/TransFun.

59 BASIC BIOLOGICAL SCIENCES↗

SU-C-303-02: Correlating Metabolic Response to Radiation Therapy with HIF-1alpha Expression

Purpose: To understand radiation induced alterations in cellular metabolism which could be used to assess treatment or normal tissue response to aid in patient-specific adaptive radiotherapy. This work aims to compare the metabolic response of two head and neck cell lines, one malignant (UM-SCC-22B) and one benign (Normal Oral Keratinocyte), to ionizing radiation. Responses are compared to alterations in HIF-1alpha expression. These dynamics can potentially serve as biomarkers in assessing treatment response allowing for patient-specific adaptive radiotherapy. Methods: Measurements of metabolism and HIF-1alpha expression were taken before and X minutes after a 10 Gy dose of radiation delivered via an orthovoltage x-ray source. In vitro changes in metabolic activity were measured via fluorescence lifetime imaging (FLIM) to assess the mean lifetime of NADH autofluorescence following a dose of 10 Gy. HIF-1alpha expression was measured via immunohistochemical staining of in vitro treated cells and expression was quantified using the FIJI software package. Results: FLIM demonstrated a decrease in the mean fluorescence lifetime of NADH by 100 ps following 10 Gy indicating a shift towards glycolytic pathways for malignant cells; whereas this benign cell line showed little change in metabolic signature. Immunohistochemical analysis showed significant changes in HIF-1alpha expression in response to 10 Gy of radiation that correlate to metabolic profiles. Conclusion: Radiation induces significant changes in metabolic activity and HIF-1alpha expression. These alterations occur on time scales approximating the duration of common radiation treatments (approximately tens of minutes). Further understanding these dynamics has important implications with regard to improvement of therapy and biomarkers of treatment response.

60 APPLIED LIFE SCIENCES↗

Sci-Thur PM – Brachytherapy 02: Positional accuracy in Pd-103 permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC)

Purpose: This retrospective study aims to quantify the positional accuracy of seed delivery in permanent breast seed implant (PBSI) brachytherapy at the Tom Baker Cancer Centre (TBCC). Methods: Treatment planning and post-implant CT scans for 5 patients were rigidly registered using the MIM Symphony™ software (MIM Software, Cleveland, OH) and used to evaluate differences between planned and implanted seed positions. Total and directional seed displacements were calculated for each patient in a clinically relevant ‘needle coordinate system’, defined relative to the angle of fiducial needle insertion. Results: The overall average total seed displacement was 10±8 mm. Systematic seed displacements were observed in individual patients and the magnitude and direction of these offsets varied among patients. One patient showed a significant directional seed displacement in the shallow-deep direction compared with the other four patients. With the exception of this one patient outlier, no significant systematic directional displacements in the needle coordinate system were observed for this cohort; the average directional displacements were −1±5 mm, 2±3 mm, and −2±4 mm in the shallow-deep, up-down, and right-left directions respectively. Conclusion: With the exception of one patient outlier, the magnitude of seed displacements were relatively consistent among patients. The results indicate that the shallow-deep direction possesses the largest uncertainty for the seed delivery method used at the TBCC. The relatively large uncertainty in seed placement in this direction is expected, as this is the direction of needle insertion. Further work will involve evaluating deflections of delivered needle tracks from their planned positions.

60 APPLIED LIFE SCIENCES↗

Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak

A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GS2: an efficiently computable measure of GO-based similarity of gene sets

Motivation: The growing availability of genome-scale datasets has attracted increasing attention to the development of computational methods for automated inference of functional similarities among genes and their products. One class of such methods measures the functional similarity of genes based on their distance in the Gene Ontology (GO). To measure the functional relatedness of a gene set, these measures consider every pair of genes in the set, and the average of all pairwise distances is calculated. However, as more data becomes available and gene sets used for analysis become larger, such pair-based calculation becomes prohibitive. Results: In this article, we propose GS2 (GO-based similarity of gene sets), a novel GO-based measure of gene set similarity that is computable in linear time in the size of the gene set. The measure quantifies the similarity of the GO annotations among a set of genes by averaging the contribution of each gene’s GO terms and their ancestor terms with respect to the GO vocabulary graph. To study the performance of our method, we compared our measure with an established pair-based measure when run on gene sets with varying degrees of functional similarities. In addition to a significant speed improvement, our method produced comparable similarity scores to the established method. Our method is available as a web-based tool and an open-source Python library. Availability: The web-based tools and Python code are available at: http://bioserver.cs.rice.edu/gs2.

59 BASIC BIOLOGICAL SCIENCES↗

FQC Dashboard: integrates FastQC results into a web-based, interactive, and extensible FASTQ quality control tool

Abstract Summary FQC is software that facilitates quality control of FASTQ files by carrying out a QC protocol using FastQC, parsing results, and aggregating quality metrics into an interactive dashboard designed to richly summarize individual sequencing runs. The dashboard groups samples in dropdowns for navigation among the data sets, utilizes human-readable configuration files to manipulate the pages and tabs, and is extensible with CSV data. Availability and implementation FQC is implemented in Python 3 and Javascript, and is maintained under an MIT license. Documentation and source code is available at: https://github.com/pnnl/fqc.

59 BASIC BIOLOGICAL SCIENCES↗

Validation of Non-Invasive Waste Assay System (Gamma Box Counter) Performance at AECL Whiteshell Laboratories - 13136

Low-level radioactive waste (LLW) in solid form, resulting from decommissioning and operations activities at AECL's Whiteshell Laboratories (WL), is packaged in B-25 and B-1000 standard waste containers and characterized before it is shipped to an on-site interim storage facility, pending AECL decisions on long term management of its LLW. Assay of the waste packages before shipment contributes to an inventory of the interim storage facility and provides data to support acceptance at a future repository. A key characterization step is a gamma spectrometric measurement carried out under standard conditions using an automated, multi-detector Waste Assay System (WAS), purchased from Antech Corporation. A combination of ORTEC gamma acquisition software and custom software is used in this system to incorporate multiple measurements from two collimated high-resolution detectors. The software corrects the intensities of the gamma spectral lines for geometry and attenuation, and generates a table of calculated activities or limits of detection for a user-defined list of radioisotopes that may potentially be present. Validation of WAS performance was a prerequisite to routine operation. Documentation of the validation process provides assurance of the quality of the results produced, which may be needed one or two decades after they were generated. Aspects of the validation included setting up a quality control routine, measurements of standard point sources in reproducible positions, study of the gamma background, optimization of user-selectable software parameters, investigation of the effect of non-uniform distribution of materials and radionuclides, and comparison of results with measurements made using other gamma detector systems designed to assay bulk materials. The following key components of the validation process have been established. A daily quality control routine has been instituted, to verify stability of the gamma detector operation and the background levels. A test box containing plywood (specific gravity 0.5) with holes for reproducible positioning of known point sources has been constructed and used in several configurations. Gamma spectra have been processed multiple times with user-adjustable parameters set to a variety of values to gain agreement on the most appropriate settings. A similar optimization process was followed with the custom software provided by the instrument manufacturer to reach agreement on the most stable settings for reliable results. Measurements made with the Canberra In-Situ Object Counting System (ISOCS) instrument were compared with the WAS results as part of an estimate of instrument precision and accuracy. The validation report will conclude with recommendations for the configuration, appropriate use and limitations of the Waste Assay System. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of Martian meteorites with earth composition: Study of effective atomic numbers in the energy range 1 keV-100 GeV

Effective atomic (Z{sub eff}) and electron numbers (N{sub eff}) for 24 Martian meteorites have been determined in the energy range from 1 keV to 100 GeV and also for sixteen significant energies of commonly used radioactive sources. The values of Z{sub eff} and N{sub eff} for all sample were obtained from the DirectZeff program. The obtained results for Martian meteorites have been compared with the results for Earth composition and similarities or differences also evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wildfire Smoke PM2.5 per Zipcode

This dataset contains daily aggregated measurements of daily PM2.5 from ambient wildfire smoke in the contiguous United States, spanning from 2006 to 2016. The data is sourced from a study by Childs et al. (2022), titled "Daily Local-Level Estimates of Ambient Wildfire Smoke PM2.5 for the Contiguous US" published in Environmental Science & Technology. To compute the standardized weight across different zip codes, we computed the weight calculation on a 10km grids. To compute the weight, we obtain area-weights that add up to 1 in each polygon of zipcodes. This enabled us to calculate the smoke values per zipcode for the aforementioned period. Those interested in replicating our data processing pipeline can access it at https://github.com/NSAPH-Data-Processing/smoke_aggregation.

PM2.5↗

gRASPA

GPU Monte Carlo Simulation Code with a taste of RASPA We present enhancements in Monte Carlo simulation speed and functionality within an open-source code, gRASPA, which uses graphical processing units (GPUs) to achieve significant performance improvements compared to serial, CPU implementations of Monte Carlo. The code supports a wide range of Monte Carlo simulations, including canonical ensemble (NVT), grand canonical, NVT Gibbs, Widom test particle insertions, and continuous-fractional component Monte Carlo. Implementation of grand canonical transition matrix Monte Carlo (GC-TMMC) and a novel feature to allow different moves for the different components of metal-organic framework (MOF) structures exemplify the capabilities of gRASPA for precise free energy calculations and enhanced adsorption studies, respectively. The introduction of a High-Throughput Computing (HTC) mode permits many Monte Carlo simulations on a single GPU device for accelerated materials discovery. The code can incorporate machine learning (ML) potentials. The open-source nature of gRASPA promotes reproducibility and openness in science, and users may add features to the code and optimize it for their own purposes. The code is written in CUDA/C++ and SYCL/C++ to support different GPU vendors. The gRASPA code is publicly available at https://github.com/snurr-group/gRASPA.

Li, Zhao [Purdue/Northwestern/Notre Dame Universit↗

SU-G-BRB-02: An Open-Source Software Analysis Library for Linear Accelerator Quality Assurance

Purpose: Routine linac quality assurance (QA) tests have become complex enough to require automation of most test analyses. A new data analysis software library was built that allows physicists to automate routine linear accelerator quality assurance tests. The package is open source, code tested, and benchmarked. Methods: Images and data were generated on a TrueBeam linac for the following routine QA tests: VMAT, starshot, CBCT, machine logs, Winston Lutz, and picket fence. The analysis library was built using the general programming language Python. Each test was analyzed with the library algorithms and compared to manual measurements taken at the time of acquisition. Results: VMAT QA results agreed within 0.1% between the library and manual measurements. Machine logs (dynalogs & trajectory logs) were successfully parsed; mechanical axis positions were verified for accuracy and MLC fluence agreed well with EPID measurements. CBCT QA measurements were within 10 HU and 0.2mm where applicable. Winston Lutz isocenter size measurements were within 0.2mm of TrueBeam’s Machine Performance Check. Starshot analysis was within 0.2mm of the Winston Lutz results for the same conditions. Picket fence images with and without a known error showed that the library was capable of detecting MLC offsets within 0.02mm. Conclusion: A new routine QA software library has been benchmarked and is available for use by the community. The library is open-source and extensible for use in larger systems.

43 PARTICLE ACCELERATORS↗

Impedance Measurement of an Antenna with Hydrogen Plasma Driven by 13.56 MHz-rf for J-PARC H{sup -} ion source

In order to satisfy the Japan Proton Accelerator Research Complex (J-PARC) second stage requirements of an H{sup -} ion beam current of 50 mA and a life-time of 2000 hours, the development of a 13.56 MHz-rf-driven H{sup -} ion source was started by using an antenna developed at the Spallation Neutron Source (SNS). As the first step, the impedance of an antenna with hydrogen plasma, which is one of the most important parameters, was measured. For an rf-power of 0 kW, 1.25 kW or 7.45 kW, it was measured as j84.19+5.107 {Omega}, j80.22+11.82 {Omega} or j58.24+21.16 {Omega}, respectively. Its real-part had a rather large value and rather large rf-power dependence unexpectedly. By using the measured impedance, the circuit to produce rf-plasma in the plasma chamber on a -50 kV potential with a 13.56 MHz-rf-source on the ground potential was designed by the circuit simulation code LTSpice IV.

43 PARTICLE ACCELERATORS↗

Radiometric characterization process for locating radioactivity hold-up and measuring non-uniformly distributed sources - 15342

A novel approach to facility radiometric characterization for non-uniformly distributed radiation sources has been developed by ANTECH and is currently being employed at the Argonne National Laboratory. It is being applied to the measurement of a wide range of objects and the interiors and contents of laboratories and buildings. The integrated non destructive assay measurement process involves the use of a scanning spectroscopic gamma ray camera as well as high purity Germanium detectors with different collimators and hence differing detector fields of view to measure and quantify non-uniformly distributed sources of radioactivity in laboratory equipment, glove boxes, storage tanks, pipework and general laboratory objects and process components. The purpose of the radiometric characterization is to quantify radiation sources and radioactive contamination levels in facilities containing nuclear material and to ensure compliance with facility characterization requirements and for decontamination and decommissioning planning and execution. The integrated measurement process also involves automated data capture and processing software and a database with which both measurement instrument operators and subject matter expert analysts can interact. An appropriate measuring instrument (gamma camera, scintillation detector, high purity Germanium detector system, neutron detector or alpha-beta counter) records the measurement data and the measurement site is recorded in a photograph. All of the data relevant to the measurement (or set of measurements for a particular object) are recorded in the database including measured gamma ray spectra, equipment description and relevant calibration, measurement site photograph and measurement descriptive data. Once data analysis protocols are established for specific geometries and measurement situations they can be applied to the measured data in a partially automated manner, reducing analysis and transcription errors. In addition to measurements and data analysis the process also utilises radiometric modelling computer codes including MicroShield and Monte Carlo Neutrons Photons in order to perform model calculations where appropriate. In a typical measurement, the ANTECH RadSearch spectroscopic gamma camera is utilized to find areas of concentrated activity so that these areas can be measured and calculated separately from areas with diffuse contamination. The use of the gamma camera in scanning mode helps to ensure that the assay does not overestimate the detected radiation source, which is a frequent consequence of using standard far field geometry and attenuation analysis codes that assume uniformity of both density and radioactive source distribution. Once the hot spots are identified, high purity Germanium detector measurements are made using various collimators with wide or narrow fields of view as required. These measurements are then processed through a semi-automatic calculation process assuming an appropriate source configuration as identified by RadSearch. These source configurations include point sources, line sources or surface sources. The Generalized Geometry Hold-up algorithms are employed to determine an estimate of the activity of the various sources that are identified in a measurement. The ANTECH integrated measurement process provides an automated calculation procedure where the analyst can select the source type, geometry and appropriate input data, and then the software calculates the activity by radionuclide for all sources identified in the measurement. The measurement and analysis process is controlled under the ANTECH ISO9001: 2008 Quality Assurance System and managed by a site specific Quality Assurance Plan. Both Argonne National Laboratory and Department of Energy technical reviewers have vetted the Integrated Measurement and Analysis Process. The application of the measurement and analysis process is described and measurement examples are provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ProteoSign: an end-user online differential proteomics statistical analysis platform

Profiling of proteome dynamics is crucial for understanding cellular behavior in response to intrinsic and extrinsic stimuli and maintenance of homeostasis. Over the last 20 years, mass spectrometry (MS) has emerged as the most powerful tool for large-scale identification and characterization of proteins. Bottom-up proteomics, the most common MS-based proteomics approach, has always been challenging in terms of data management, processing, analysis and visualization, with modern instruments capable of producing several gigabytes of data out of a single experiment. Here, we present ProteoSign, a freely available web application, dedicated in allowing users to perform proteomics differential expression/abundance analysis in a userfriendly and self-explanatory way. Although several non-commercial standalone tools have been developed for post-quantification statistical analysis of proteomics data, most of them are not end-user appealing as they often require very stringent installation of programming environments, third-party software packages and sometimes further scripting or computer programming. To avoid this bottleneck, we have developed a user-friendly software platform accessible via a web interface in order to enable proteomics laboratories and core facilities to statistically analyse quantitative proteomics data sets in a resource-efficient manner. ProteoSign is available at http://bioinformatics.med.uoc.gr/ProteoSign and the source code at https://github.com/yorgodillo/ ProteoSign.

59 BASIC BIOLOGICAL SCIENCES↗

On the feasibility of optical-CT imaging in media of different refractive index

Purpose: Achieving accurate optical-CT 3D dosimetry without the use of viscous refractive index (RI) matching fluids would greatly increase convenience. Methods: Software has been developed to simulate optical-CT 3D dosimetry for a range of scanning configurations including parallel-beam, point, and converging light sources. For each configuration the efficacy of three refractive media was investigated: air, water, a fluid closely matched to PRESAGE{sup Registered-Sign }, and perfect matching (RI = 1.00, 1.33, 1.49, and 1.501 respectively). Reconstructions were performed using both filtered backprojection (FBP) and algebraic reconstruction technique (ART). The efficacy of the three configurations and the two algorithms was evaluated by calculating the usable radius (i.e., the outermost radius where data were accurate to within 2%), and gamma ({Gamma}) analysis. This definition recognizes that for optical-CT imaging, errors are greatest near the edge of the dosimeter, where refraction can be most pronounced. Simulations were performed on three types of dose distribution: uniform, volumetric modulated arc therapy (VMAT), and brachytherapy (Cs-137). Results: For a uniformly irradiated dosimeter the usable radius achieved with filtered backprojection was 68% for water-matching and 31% for dry-scanning in air. Algebraic reconstruction gave usable radii of 99% for both water and air (dry-scanning), indicating greater recovery of useful data for the uniform distribution. FBP and ART performed equally well for a VMAT dose distribution where less dose is delivered near the edge of the dosimeter. In this case, the usable radius was 86% and 53% for scanning in water and air, respectively. For brachytherapy, the usable radius was 99% and 98% for scanning in water and air, respectively using FBP, and a major decrease was seen with ART. Point source geometry provided 1%-2% larger usable radii than parallel geometry. Converging geometry recovered less usable dosimetry data (up to 10% reduced usable radii) than point and parallel geometries. A further disadvantage of converging geometry was an increased requirement on detector size by up to 18 Degree-Sign . Conclusions: For applications where dose information is not required in the periphery of the dosimeter, some dry and low-viscous matching configurations may be feasible. For all three dose distributions (uniform, VMAT, brachytherapy) the point source geometry produced slightly more favorable results (an extra 1%-2% usable radii) than parallel and converging. When dosimetry is required on the periphery, best results were obtained using close refractive matching and ART. A concern for water or dry-scanning is the increase in required detector size, introducing potential cost penalties for manufacturing.

36 MATERIALS SCIENCE↗

Final Report for ALCC Allocation: Predictive Simulation of Complex Flow in Wind Farms

This report documents work performed using ALCC computing resources granted under a proposal submitted in February 2016, with the resource allocation period spanning the period July 2016 through June 2017. The award allocation was 10.7 million processor-hours at the National Energy Research Scientific Computing Center. The simulations performed were in support of two projects: the Atmosphere to Electrons (A2e) project, supported by the DOE EERE office; and the Exascale Computing Project (ECP), supported by the DOE Office of Science. The project team for both efforts consists of staff scientists and postdocs from Sandia National Laboratories and the National Renewable Energy Laboratory. At the heart of these projects is the open-source computational-fluid-dynamics (CFD) code, Nalu. Nalu solves the low-Mach-number Navier-Stokes equations using an unstructured- grid discretization. Nalu leverages the open-source Trilinos solver library and the Sierra Toolkit (STK) for parallelization and I/O. This report documents baseline computational performance of the Nalu code on problems of direct relevance to the wind plant physics application - namely, Large Eddy Simulation (LES) of an atmospheric boundary layer (ABL) flow and wall-modeled LES of a flow past a static wind turbine rotor blade. Parallel performance of Nalu and its constituent solver routines residing in the Trilinos library has been assessed previously under various campaigns. However, both Nalu and Trilinos have been, and remain, in active development and resources have not been available previously to rigorously track code performance over time. With the initiation of the ECP, it is important to establish and document baseline code performance on the problems of interest. This will allow the project team to identify and target any deficiencies in performance, as well as highlight any performance bottlenecks as we exercise the code on a greater variety of platforms and at larger scales. The current study is rather modest in scale, examining performance on problem sizes of O(100 million) elements and core counts up to 8k cores. This will be expanded as more computational resources become available to the projects.

17 WIND ENERGY↗