Search NASASearch

SEARCH · Search NASA

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Dataset for First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics

The Nab apparatus at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source was designed to measure key observations in neutron beta decay, test the Standard Model's description of the weak interaction, and search for new physics. This data was collected using the Nab apparatus and are presented in the article "First Full Dalitz Plot Measurement in Neutron β-Decay using the Nab Spectrometer and Implications for New Physics." This data publication includes CSV (comma-separated values) files which are used to generate Figures 3 - 11 in the linked journal article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Fast data-driven spectrometer with direct measurement of time and frequency for multiple single photons

We present a single-photon-sensitive spectrometer based on a linear array of 512 single-photon avalanche diode detectors with 0.04 nm spectral and 40 ps temporal resolutions. We employ a fast data-driven operation that allows direct measurement of time and frequency for simultaneous single photons, time- and frequency-stamping each single-photon detection. Our results combine excellent temporal and spectral resolution. This work opens numerous applications in quantum photonics, especially when both spectral and temporal properties of single photons can be exploited.

79 ASTRONOMY AND ASTROPHYSICS

Milestone report for MRT 8504: Commission EXAFS spectrometer with spectral range of 17.95-18.6 keV design to obtain EXAFS data for Pu L shell experiments

This milestone describes the development and fielding of EXAFS Phase II spectrometer designed to provide high quality (SNR>=5) EXAFS spectra for Plutonium measurements at the National Ignition facility (NIF). Benefits: the EXAFS data will be used by the High Energy Density (HED) Physics and more specifically the Focused Material Science program to measure the thermal state of compressed materials with good temperature sensitivity (~100-1000 Kelvin). Data with good signal to noise ratio (SNR>=5) and good spectral resolution allows the FMS program to fill a gap in diagnosing temperature to completely constrain material properties for weapon physics and Stockpile Stewardship applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Continued Evaluation of the Use of a Raman Spectrometer for H-Canyon Dissolver Monitoring

Remote monitoring of dissolver activities in H-Canyon can help operators avoid delays associated with excessive levels of fuel fragments remaining after a run. SRNL has proposed that effective monitoring can be achieved by using a Raman spectrometer to measure NO 2 concentrations in the offgas stream sampled from the facility stack. Prior work (SRNL-STI-2021-00451) measuring the offgas from one dissolution batch of High Flux Isotope Reactor (HFIR) fuel suggested a relationship between %NO 2 levels and fragment height. Herein, we report the results of monitoring and analysis of the dissolution of four batches of Material Test Reactor (MTR) fuel. A rigorous quantitative relationship between %NO 2 measurements and fragment heights could not be established, due to high uncertainties associated with both measurements. Uncertainties with gas measurements are associated with the %NO 2 levels in the offgas being close to the detection limit for the analyzer. Alternative gas measurement strategies are discussed which could improve sensitivity and reduce uncertainty. Limitations to the precision of the probe measurements are also discussed. It is also noted that the offgas is an average of the products from simultaneous dissolution of elements in multiple wells. Detection of a high fragment height level in an individual well may be hindered by low levels in other wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W

Characterization of the Multi-Coincident Bismuth Germanate Oxide Spectrometer at the Nuclear Counting Facility

A multi-detector γ-ray spectroscopy system including 3 high-purity germanium (HPGe) detectors has been developed at the Nuclear Counting Facility at Lawrence Livermore National Laboratory. This system operates not only in conventional singles γ-ray detection mode but also incorporates features like coincidence and anti-coincidence techniques. These advanced detection modes can significantly enhance the system’s sensitivity, making it a powerful tool for isotope identification and quantification, especially for complex samples with high background and overlapping peaks. In this re port, we present a comprehensive performance characterization of the Multi-Coincident Bismuth Oxide Spectrometer (MCBOS) using a variety of sample types, including 60 Co, 48 Sc, and mixed fission product samples. Each sample provides unique tests for the MCBOS capabilities. Additionally, a GEANT4 model of the MCBOS has been generated to aid with the characterization of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Improved Chopper System for a Direct Geometry Spectrometer at the Second Target Station

This report describes a chopper cascade suitable for a cold direct geometry spectrometer at a pulsed neutron source with a low repetition rate such as the Second Target Station (STS) currently being planned at Oak Ridge National Laboratory (ORNL). The chopper cascade offers the following capabilities: selection of a variable number of pulses per frame (flexible pulse suppression), selection of pulses with increasing timing separation within one frame, and an increasing pulse width ∆t within one frame, in order to achieve an even energy resolution over several pulses at different wavelengths across the frame.

43 PARTICLE ACCELERATORS

Testing, Calibration, and UxS Integration of the Kromek GR1 Plus CZT Gamma Spectrometer

Collecting radiation measurements can be a hazardous task, especially in the presence of highly active sources. Various scenarios necessitate source search, classification, and quantification, often with limited or no a priori information. Activities such as disaster mitigation, emergency response, environmental monitoring, and site remediation may involve dangerous radioactive sources. In these situations, there is a pressing need for remote monitoring capabilities that protect human operators from potential harm and enhance adherence to the principle of “As Low as Reasonably Achievable” (ALARA) for radiation doses. The first step toward achieving remote radiation measurement capabilities is the remote operation of a radiation sensor. Once this milestone is reached, the next challenge is to integrate this remote sensing capability into suitable actuation agents, collectively referred to as uncrewed systems (UxS). These systems include familiar platforms such as robotic quadrupeds, aerial multirotor vehicles, and ground vehicles, any of which may be teleoperated, act autonomously, or utilize a combination of both. A critical factor in achieving remote radiation sensing is the availability of data from the appropriate sensor. Many commercially available radiation sensors have closed-source documentation for their communication protocols. Typical end-user products are often self-contained, handheld devices designed for manual measurement scenarios. While there are commercial off-the-shelf (COTS) integrations of radiation sensors with UxS available for purchase, these solutions are typically tailored for specific use cases and may not meet the requirements of different applications. This paper discusses efforts to remotely acquire radiation measurements from a small form-factor CZT gamma spectrometer. Sandia National Laboratories has successfully demonstrated the initial capability to integrate low size, weight, and power (SWaP) gamma spectroscopy into various UxS, alongside co-located GPS data logging and sensor calibration and qualification. With remote gamma spectroscopy achieved, the stage is set for UxS integration of this capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND

Network of Modified Portable Optical Particle Spectrometers Instrument Handbook

The U.S. Department of Energy Atmospheric Radiation Measurement (ARM) user facility’s portable optical particle spectrometer (POPS) network (Figure 1) provides an aerosol size distribution spectrum from 150 nm to 5 μm in 16 logarithmically spaced bins. The data emanating from this network of up to four matching POPS in weatherproof enclosures comprises one-minute averages of the aerosol size and number spectrum and the co-located temperature and relative humidity. The total particle concentration and sample flow rate are also provided. The sample stream is not dried before its measurement. Two size spectra are provided: the default size distribution corresponds to the calibration using polystyrene latex spheres (PSL), while the second size distribution corresponds to the calibration using size-selected dry ammonium sulfate aerosol. The principal scientific application of the data provided by the ARM POPS is to determine the aerosol size distribution across a region in three disparate locations – the size distribution is broadly relevant to studies of pollution and of conditions in the boundary layer. A high particle concentration can be an indicator of unhealthy levels of pollution; the dispersion of particles in the atmosphere is a predictor of long-range visibility; and particles serve as collectors of condensing gases including water vapor, and thus are a factor in the formation and properties of fogs and clouds, and in the initiation of precipitation.

54 ENVIRONMENTAL SCIENCES

Autonomous Ion Mass Spectrometer Sentry (AIMSS)

Satellite measurements of plasma density and temperature help predict the intensity of geomagnetic storms, which can impact satellites, communications, and power systems. Accurate forecasting requires knowledge of plasma composition. However, typical orbital mass spectrometers have difficulty distinguishing between nitrogen (N+) and oxygen (O+) ions due to their similar masses. This limitation makes it difficult to validate modern space weather models, which depend on accurate knowledge of ion composition in near-Earth space. N+ and O+ ions behave differently in space due to differences in their origin, transport, and loss mechanisms. Improving our ability to distinguish between these ions is critical for understanding and predicting space weather.

47 OTHER INSTRUMENTATION

Improvements in the Sample Space for the Backscattering Silicon Spectrometer (BASIS)

The increase in neutron flux at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS), currently operating at 2.0 MW proton beam power, has created new opportunities for higher-throughput neutron scattering experiments while also increasing the importance of minimizing background scattering and optimizing sample-environment operations. To address these challenges on the Backscattering Silicon Spectrometer (BA-SIS), several upgrades were developed and evaluated, including boron carbide (B₄C) masking for flat-plate sample containers, multi-cell sample holders used with a vertically translating sample stick, and an automated helium pump and purge (HPP) system for closed-cycle refrigerators. Neutron diffraction measurements demonstrate that B₄C masks reduce background scattering by 49–67%, outperforming both borated aluminum and boron nitride masks while introducing no additional Bragg reflections within the instrument’s accessible Q-range. Commissioning tests of a double-cell flat-plate sample contain-er showed no measurable crosstalk between adjacent sample compartments and con-firmed stable thermal performance, enabling multiple samples to be measured without re-peated temperature cycling. In addition, the automated HPP system provided reproducible sample-space gas handling with approximately ±1 mbar precision while reducing the need for operator intervention and supporting remote operation. Together, these developments improve signal-to-noise performance, increase experimental throughput, and enhance operational efficiency at BASIS, supporting the instrument’s continued operation under higher neutron flux conditions.

Jalarvo, Niina [ORNL] (ORCID:0000000306446866)

Measurement report: The Fifth International Workshop on Ice Nucleation phase 1 (FIN-01): intercomparison of single-particle mass spectrometers

Knowledge of the chemical composition and mixing state of aerosols at a single-particle level is critical for gaining insights into atmospheric processes. One common tool to make these measurements is single-particle mass spectrometry. There remains a need to compare the performance of different single-particle mass spectrometers (SPMSs). An intercomparison of SPMSs was conducted at the Aerosol Interaction and Dynamics in the Atmosphere (AIDA) chamber at the Karlsruhe Institute of Technology (KIT) in November 2014, as part of the first phase of the Fifth International Workshop on Ice Nucleation (FIN-01). In this paper we compare size distributions and mass spectra of atmospherically relevant particle types measured by five SPMSs. These include different minerals, desert and soil dusts, soot, bioaerosol (Snomax; protein granule), secondary organic aerosol (SOA), and SOA-coated mineral particles. Most SPMSs reported similar vacuum aerodynamic diameter (d va ) within typical instrumental ranges from ~100–200 nm (lower limit) to ~2–3 µm (upper limit). In general, all SPMSs exhibited a wide dynamic range (up to ~10 3 ) and high signal-to-noise ratio (up to ~10 4 ) in mass spectra. Common spectral features with small diversities in mass spectra were found with high average Pearson's correlation coefficients, i.e., for average positive spectra r avg-pos =0.74 ± 0.12 and average negative spectra r avg-neg =0.67 ± 0.22. We found that instrument-specific detection efficiency (DE) was more dependent on particle size than particle type, and particle identification favored the use of bipolar, rather than monopolar, instruments. Particle classification from “blind experiments” showed that all instruments differentiated SOA, soot, and soil dust and detected subtle changes in the particle internal mixing but had difficulties differentiating among specific mineral types and dusts. This study helps to further understand the capabilities and limitations of the single-particle mass spectrometry technique in general and the specific performance of the instrument in characterizing atmospheric aerosol particles.

54 ENVIRONMENTAL SCIENCES

EPCAPE-PT-LANL Measurements: Soot Particle Aerosol Mass Spectrometer

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Soot particle-Aerosol Mass Spectrometer. (Aerodyne Inc.) Header: - Organic_GCVIoff[ug/m3]: Concentration of organic compounds measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Nitrate_GCVIoff[ug/m3]: Concentration of nitrate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Sulfate_GCVIoff[ug/m3]: Concentration of sulfate measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Chloride_GCVIoff[ug/m3]: Concentration of chloride measured via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Ammonium_GCVIoff[ug/m3]: Concentration of ammonium via the Main Inlet (out-of-cloud) in micrograms per cubic meter. - Organic_GCVIon[ug/m3]: Concentration of organic compounds measured in-cloud via CVI in micrograms per cubic meter. - Nitrate_GCVIon[ug/m3]: Concentration of nitrate measured in-cloud via CVI in micrograms per cubic meter. - Sulfate_GCVIon[ug/m3]: Concentration of sulfate measured in-cloud via CVI in micrograms per cubic meter. - Chloride_GCVIon[ug/m3]: Concentration of chloride measured in-cloud via CVI in micrograms per cubic meter. - Ammonium_GCVIon[ug/m3]: Concentration of ammonium measured in-cloud via CVI in micrograms per cubic meter. - CVI_Flag[bool]: A boolean flag indicating whether the CVI was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES

Cloud Condensation Nuclei and Printed Optical Particle Spectrometer Measurements at Mt. Soledad during EPCAPE 2023-24

These measurements are provided by a differential mobility analyzer operated as a scanning mobility particle sizer, a printed particle optical spectrometer (POPS), and a continuous flow diffusion cloud condensation nuclei (CCN) counter. The instruments sample from either a counterflow virtual impactor inlet or an isokinetic inlet. The measurements provide the mobility aerosol size distribution (30-360 nm), optical size distribution (150 - 6000 nm), size-resolved CCN distribution (30-360 nm) at 0.2, 0.4, 0.6, 0.8, and 1.0% supersaturation. CCN measurements are performed in denuded and undenuded configuration, where denuded refers to the removal of low molecular weight organic vapors. A detailed NetCDF header is included with the datafiles. Users of these measurements are encouraged to consult with the authors about appropriate interpretation before submitting for publication, offering coauthorship where appropriate.

54 ENVIRONMENTAL SCIENCES

SCILLA mini-Aerosol Mass Spectrometer (mAMS) airborne data

Measurements of non-refractory, sub-micron aerosol composition, namely organic, sulfate, nitrate, chloride, and ammonium aerosols, by a mini- aerosol mass spectrometer (mAMS, Aerodyne Research, Inc.) are reported. The instrument sampled ambient air through 3 different inlets: unperturbed ambient air, a Counter-flow Virtual Impactor (CVI), and an oxidation flow reactor (OFR). Users should consult the Sampling Key for proper interpretation of the data.

and secondary aerosol in air",total_organics,nitra

The General Antiparticle Spectrometer (GAPS) Antarctic Balloon Payload

The General Antiparticle Spectrometer (GAPS) is an Antarctic stratospheric balloon mission designed to provide unmatched sensitivity to low-energy (<0.25 GeV/n) cosmic-ray antiprotons, antideuterons, and antihelium nuclei as signatures of dark matter. The distinctive GAPS particle identification technique relies on measuring the energy loss along the track of an incoming antinucleus as it slows down and is captured into an exotic atom, and then detecting the de-excitation X-rays and the nuclear annihilation products. This measurement is realized using a Tracker composed of more than 1000 custom silicon strip detectors and a plastic scintillator time-of-flight (TOF) system instrumenting more than 40m$^2$. Together, these subsystems provide the velocity and energy resolution, stopping power, particle tracking, and X-ray identification necessary to distinguish rare antinucleus signals from the abundant positive-nucleus backgrounds, all within the constraints of a high-altitude mission. A multi-loop capillary heat pipe system has been developed to maintain the tracker operating temperature with significant mass and power savings over a conventional pump-based system. The first GAPS science payload flew for 25 days during the 2025/26 NASA Antarctic balloon campaign. We detail the design, integration, and commissioning of the payload prior to flight.

Aoyama, Kazutaka [JAXA, Sagamihara]

A 3D-Printed Millimeter-Wave Inline Waveguide-to-Coplanar-Waveguide Transition to Enable Dense Spectrometer Arrays for Intensity Mapping Surveys

We present a 3D-printed millimeter-wave, octave-bandwidth, in-line waveguide-to-coplanar-waveguide transition designed to enable focal planes with dense arrays of on-chip spectrometers. These arrays will enable compelling surveys of the large-scale structure of the universe through millimeter-wave intensity mapping. The transition consists of a four-step ridge-waveguide transformer that couples light from a rectangular waveguide onto a coplanar waveguide via an electrical connection made with indium bump bonds. We develop a tolerance-aware optimization approach to identify high-performance transition geometries that are robust to manufacturing variations; the same formulation can be applied to other tolerance-sensitive design problems. We also describe the implementation of a custom apparatus and procedure for bump-bonding a silicon chip to a metallized 3D-printed component. We detail the fabrication of the coplanar waveguide chip and three-dimensional waveguide structure, simulations and metrology of a test device, and room temperature reflectance measurements of this device. The room temperature metrology and reflection measurements are consistent with a model that predicts a coupling efficiency of $\mathord{\sim} 95\%$ at cryogenic temperatures in the 85-170 GHz frequency range.

Stover, Austin [Chicago U.; Chicago U., KICP] (ORC

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA