Search NASA⌕ Search

SEARCH · Search NASA

Results for “Spectrometry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Online detection of airborne nanoparticle composition with mass spectrometry: Recent advances, challenges, and opportunities

Airborne nanoparticles are receiving growing attention due to their impacts on human health, air quality, and climate. Additionally, there are increasing applications of aerosol-based nanotechnology. Real-time measurement of airborne nanoparticle composition is challenging due to their small masses and the difficulties in effectively separating them from larger particles. Custom-built instruments based on mass spectrometry have been developed for nanoparticle composition, including thermal desorption-based, laser-based, and solution-based techniques. They have significantly promoted the understanding of airborne nanoparticles in the last two decades. However, they are affected by molecular fragmentation, lack of mass-resolving power, incomplete species detection, and difficulties in directly comparing to gas-phase measurements. Recent developments in atmospheric mass spectrometry provide possible solutions. Here, this review presents the potential application of these new advances to real-time measurements of the molecular nanoparticle composition and discusses the associated challenges. Such measurements present opportunities for a more comprehensive view of airborne nanoparticles and their impacts.

47 OTHER INSTRUMENTATION↗

Experimental Assessment of Mammalian Lipidome Complexity Using Multimodal 21 T FTICR Mass Spectrometry Imaging

Herein, we assess the complementarity and complexity of data that can be detected within mammalian lipidome mass spectrometry imaging (MSI) via matrix-assisted laser desorption ionization (MALDI) and nanospray desorption electrospray ionization (nano-DESI). We do so by employing 21 T Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) with absorption mode FT processing in both cases, allowing unmatched mass resolving power per unit time (≥613k at m/z 760, 1.536 s transients). While our results demonstrated that molecular coverage and dynamic range capabilities were greater in MALDI analysis, nano-DESI provided superior mass error, and all annotations for both modes had sub-ppm error. Taken together, these experiments highlight the coverage of 1676 lipids and serve as a functional guide for expected lipidome complexity within nano-DESI-MSI and MALDI-MSI. To further assess the lipidome complexity, mass splits (i.e., the difference in mass between neighboring peaks) within single pixels were collated across all pixels from each respective MSI experiment. The spatial localization of these mass splits was powerful in informing whether the observed mass splits were biological or artificial (e.g., matrix related). Mass splits down to 2.4 mDa were observed (i.e., sodium adduct ambiguity) in each experiment, and both modalities highlighted comparable degrees of lipidome complexity. Further, we highlight the persistence of certain mass splits (e.g., 8.9 mDa; double bond ambiguity) independent of ionization biases. Here, we also evaluate the need for ultrahigh mass resolving power for mass splits ≤4.6 mDa (potassium adduct ambiguity) at m/z > 1000, which may only be resolved by advanced FTICR-MS instrumentation.

21T-FTICR-MS↗

A Dual-Gated Structures for Lossless Ion Manipulations-Ion Mobility Orbitrap Mass Spectrometry Platform for Combined Ultra-High-Resolution Molecular Analysis

High-resolution ion mobility spectrometry-mass spectrometry (HR-IMS-MS) instruments have enormously advanced the ability to characterize complex biological mixtures. Unfortunately, HR-IMS and HR-MS measurements are typically performed independently due to mismatches in analysis time scales. Here we overcome this limitation by using a dual-gated ion injection approach to couple an 11-meter path length structures for lossless ion manipulations (SLIM) module to a Q-Exactive Plus Orbitrap MS. The dual-gate setup was implemented by placing one ion gate before the SLIM module and a second ion gate after. The dual-gated ion injection approach allowed the new SLIM-Orbitrap platform to simultaneously perform an 11-meter SLIM separation, Orbitrap mass analysis using the highest selectable mass resolution setting (up to 140k), and high-energy collision induced dissociation (HCD) in ~25 minutes over an $m/z$ range of ~1500 amu. The SLIM-Orbitrap was initially characterized using a mixture of standard phosphazene cations and demonstrated an average SLIM CCS resolving power (Rp CCS ) of ~218 and SLIM peak capacity of ~156 while simultaneously obtaining high mass resolutions. SLIM-Orbitrap analysis with fragmentation was then performed on mixtures of standard peptides and two reverse peptides (SDGRG 1+ , GRGDS 1+ , Rp CCS = 305) to demonstrate the utility of combined HR-IMS-MS/MS measurements for peptide identification. Our new HR-IMS-MS/MS capability was further demonstrated by analyzing a complex lipid mixture and showcasing SLIM separations on isobaric lipids. In conclusion, this new SLIM-Orbitrap platform demonstrates a critical new capability for proteomics and lipidomics applications, and the high-resolution multimodal data obtainable with this system establishes the foundation for reference-free identification of unknown ion structures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing the Impact of Measurement Precision on Metabolite Identification Probability in Multidimensional Mass Spectrometry-Based, Reference-Free Metabolomics

Identification of compounds with minimal ambiguity remains a central challenge in mass spectrometry-based metabolomics. Conventional compound identification relies on comparing analytical signatures (e.g., mass-to-charge ratio, collision cross section, tandem mass spectra) against reference data obtained from measurements of authentic chemical standards. The breadth of annotatable compounds using this approach is necessarily limited by availability of authentic standards, analytical throughput, and resolving power of the separations that underly the measurements. The maturation of computational methods, both theory-driven and artificial intelligence/machine learning-based, for prediction of various molecular properties relevant to multidimensional mass spectrometry measurements has opened the door to a new “reference-free” paradigm of compound annotation. Through augmenting existing reference data for molecular properties with computational predictions, the universe of identifiable chemical species can be expanded significantly beyond its current limits. An unexplored aspect of this novel approach is understanding how to gauge confidence in resulting annotations, especially as the compound search space is expanded. Intuitively, the confidence of a compound annotation is related to the inherent discriminatory power of the molecular properties used for identification, as well as the precision with which the properties are measured or predicted. In this work, we characterize this relationship between measurement precision and identification probability in a systematic and quantitative fashion for a defined region of chemical space that includes organic small molecule metabolites. Importantly, this work establishes a framework for conducting metabolite identification probability analysis that enables others to quantify this relationship for their own compounds and properties of interest.

Metabolite Identification↗

macroMS: Image-Guided Analysis of Random Objects by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

Mass spectrometry imaging is well-suited to characterizing sample surfaces for their chemical content in a spatially resolved manner. However, when the surface contains small objects with significant empty spaces between them, more efficient approaches to sample acquisition are possible. Image-guided mass spectrometry (MS) enables high-throughput analysis of a diverse range of sample types, such as microbial colonies, liquid microdroplets, and others, by recognizing and analyzing selected location targets in an image. Here, we describe an imaging protocol and macroMS, an online software suite that can be used to enhance MS measurements of macroscopic samples that are imaged by a camera or a flatbed scanner. Furthermore, the web-based tool enables users to find and filter targets from the optical images, correct optical distortion issues for improved spatial location of selected targets, input the custom geometry files into an MS device to acquire spectra at the selected locations, and finally, perform limited data analysis and use visualization tools to aid locating samples containing compounds of interest. Using the macroMS suite, an enzyme mutant library of Saccharomyces cerevisiae and nL droplet arrays of Escherichia coli and Pseudomonas fluorescens have been assayed at a rate of ~2 s/sample.

47 OTHER INSTRUMENTATION↗

Review of the Third Conference of the Imaging Mass Spectrometry Society (IMSS 3): Accounts of a Hybrid Virtual and In-Person Meeting and the State and Future of the Field

The third annual conference of the Imaging Mass Spectrometry Society (IMSS3) was held October 3–6, 2021 in a hybrid format that included virtual and in-person attendance (Colorado Springs, CO). In this work, we highlight many of the methods and applications presented, the state of the field, and some insights into the emerging areas in the field of imaging mass spectrometry. We also reflect upon the processes behind planning a hybrid conference and discuss the successes and challenges of the event in retrospect.

47 OTHER INSTRUMENTATION↗

“Did you eat a MOLEcule today?” An Interactive Demonstration of Molecular Weight with Real-Time Breath Analysis Using Mass Spectrometry for All Ages

Although mass spectrometry is a widely used analytical tool, age-appropriate, interactive outreach activities for laboratory visitors, especially children, are lacking. Furthermore, the presented interactive demonstration, “Did you eat a MOLEcule today?”, introduces all ages to molecular weight concepts and mass spectrometry in a research laboratory, while connecting the concepts to real-world applications. Through real-time breath analysis, participants explore the concepts of molecular weight, electrostatic field manipulation of charged molecules, and analyte identification by mass analysis. This module is rapid and highly adaptable for outreach activities but also includes age- or classroom-appropriate variations to decrease or increase difficulty levels. The presented interactive demonstration has repeatedly been implemented, with over 2300 participants during six annual “Take Our Daughters & Sons to Work Day” and two corporate “Family Day” outreach activities, successfully engaging, exciting, and educating both kids and parents.

36 MATERIALS SCIENCE↗

Large Individual Ion FTICR Measurements from the Mid-1990s Using Reactions for Charge Determination Mass Spectrometry

This article discusses from a personal and present-day perspective the first studies of large highly charged individual molecular ions that were conducted using electrospray ionization (ESI) with Fourier transform ion cyclotron resonance (FTICR) MS in the mid-1990s. These studies are distinguished from current Charge Detection Mass Spectrometry (CDMS) research primarily by their use of individual ion charge state changes due to reactions. Here this work describes the key differences in technologies and methods with present CDMS, and the likely implications of these differences. I also comment on surprising individual ion behavior observed in some measurements involving increases in charge state, as well as their possible basis, and also briefly discuss the potential utility of the reaction-based mass measurement approach used in the context of what might more globally be referred to as ‘Charge Determination Mass Spectrometry’.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Simple and Flexible Infusion Platform for Automated Native Mass Spectrometry Analysis

High throughput native mass spectrometry analysis of proteins and protein complexes has been enabled by recent development of infusion and liquid chromatography (LC) systems, which often include complete LC pumps without fully utilizing their gradient flows. We demonstrated a lower-cost infusion cart for native mass spectrometry applications using a single isocratic solvent pump that can operate at both nano- and high-flow configurations (0.05-150 $μ$L/min) for both infusion and online buffer exchange experiments. In conclusion, the platform is controlled via open-source software and can potentially be expanded for customized experimental designs, offering a lower cost alternative to laboratories with limited budgets and/or needs in student training.

47 OTHER INSTRUMENTATION↗

Identification of Unique Fragmentation Patterns of Fentanyl Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

The opioid crisis in the United States is being fueled by the rapid emergence of new fentanyl analogs and precursors that can elude traditional library-based screening methods, which require data from known reference compounds. Since reference compounds are unavailable for new fentanyl analogs, we examined if fentanyls (fentanyl + fentanyl analogs) could be identified in a reference-free manner using a combination of electrospray ionization (ESI), high-resolution ion mobility (IM) spectrometry, high-resolution mass spectrometry (MS), and higher-energy collision-induced dissociation (MS/MS). We analyzed a mixture containing nine fentanyls and W-15 (a structurally similar molecule) and found that the protonated forms of all fentanyls uniquely exhibited two baseline separated IM distributions that produced different MS/MS patterns. Upon fragmentation, both IM distributions of all fentanyls produced two high intensity fragments resulting from amine site cleavages. The higher mobility distributions of all fentanyls also produced several low intensity fragments, but surprisingly, these same fragments exhibited much greater intensities in the lower mobility distributions. This observation demonstrates that many fragments of fentanyls predominantly originate from one of two different gas-phase structures (suggestive of protomers). Furthermore, increasing the water concentration in the ESI solution increased the intensity of the lower mobility distribution relative to the higher mobility distribution, which further supports that fentanyls exist as two gas-phase protomers. In conclusion, our new observations on the IM and MS/MS properties of fentanyls can be exploited to positively identify them as fentanyls without requiring reference libraries and will hopefully assist first responders and law enforcement in combating new and emerging fentanyls.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Gas-Phase Behavior of Nitazene Analog Protomers Using Structures for Lossless Ion Manipulations Ion Mobility-Orbitrap Mass Spectrometry

2-benzylbenzimidazoles, or “nitazenes”, are a class of novel synthetic opioids (NSOs) that are increasingly being detected alongside fentanyl analogs and other opioids in drug overdose cases. Nitazenes can be 20x more potent than fentanyl but are not routinely tested for during postmortem or clinical toxicology drug screens; thus, their prevalence in drug overdose cases may be under-reported. Traditional analytical workflows utilizing liquid chromatography-tandem mass spectrometry (LC-MS/MS) often require additional confirmation with authentic reference standards to identify a novel nitazene. However, additional analytical measurements with ion mobility spectrometry (IMS) may provide a path towards reference-free identification, which would greatly accelerate NSO identification rates in toxicology labs. Presented here are the first IMS and collision cross section (CCS) measurements on a set of fourteen nitazene analogs using a Structures for Lossless Ion Manipulations (SLIM)-Orbitrap MS. All nitazenes exhibited two high intensity baseline-separated IMS distributions, which fentanyls and other drug and drug-like compounds also exhibit. Incorporating water into the electrospray ionization (ESI) solution caused the intensities of the higher mobility IMS distributions to increase the intensities of the lower mobility IMS distributions to decrease. Nitazenes lacking a nitro group at the R1 position exhibited the greatest shifts in signal intensities due to water. Furthermore, IMS-MS/MS experiments showed that the higher mobility IMS distributions of all nitazenes produced fragment ions with m/z 72, 100, and other low intensity fragments while the lower mobility IMS distributions only produced fragment ions with m/z 72 and 100. The IMS, solvent, and fragmentation studies provide experimental evidence that nitazenes potentially exhibit three gas-phase protomers. In conclusion, the cyclic IMS capability of SLIM was also employed to partially resolve four sets of structurally similar nitazene isomers (e.g., protonitazene/isotonitazene, butonitazene/isobutonitazene/secbutonitazene), showcasing the potential of using high-resolution IMS separations in MS-based workflows for reference-free identification of emerging nitazenes and other NSOs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ambient ion focusing from a field-free region to a detector: enhanced signal for explosives and drug detection with mass spectrometry

This study demonstrates ion focusing at ambient pressure and increased ion signal by creating a voltage gradient from a field-free region to a detector, thereby improving the detection of chemicals, such as explosives and drugs. At ambient pressure, ion loss and resulting signal reduction pose challenges that limit detection sensitivity in analytical instruments. Techniques to increase sensitivity, such as atmospheric flow tube-mass spectrometry (AFT-MS), extend ion-molecule reaction times but result in significant overall ion loss due to diffusion. Ion manipulation techniques, though challenging at ambient pressure, can mitigate these losses by concentrating ions toward the detector inlet. Using SIMION, ion trajectories were modeled with a voltage gradient applied between a flow tube and a detector, revealing ion focusing at ambient pressure. Experimental verification with an atmospheric flow tube employed both mass spectrometry and Faraday plate detectors to measure ion beam profiles across varying flow rates, tube diameters, and voltage gradients. Application of a voltage gradient effectively directed ions to the axial center of the flow tube, narrowed ion beam width, and increased signal intensity by 5 to 10 times compared to conditions without a voltage gradient. This ion focusing approach shows promise for improving sensitivity in ambient-pressure instruments. This technique has the potential to enhance detection levels in security and forensic applications, with particular benefits for field-portable devices used at checkpoints to identify explosives and drugs.

ambient pressure↗

Carbon nanotube substrates enhance SARS-CoV-2 spike protein ion yields in matrix-assisted laser desorption–ionization mass spectrometry

Nanostructured surfaces enhance ion yields in matrix-assisted laser desorption–ionization mass spectrometry (MALDI-MS). The spike protein complex, S1, is one fingerprint signature of Sars-CoV-2 with a mass of 75 kDa. Here, we show that MALDI-MS yields of Sars-CoV-2 spike protein ions in the 100 kDa range are enhanced 50-fold when the matrix–analyte solution is placed on substrates that are coated with a dense forest of multi-walled carbon nanotubes, compared to yields from uncoated substrates. Nanostructured substrates can support the development of mass spectrometry techniques for sensitive pathogen detection and environmental monitoring.

60 APPLIED LIFE SCIENCES↗

Combining MicroED and native mass spectrometry for structural discovery of enzyme–small molecule complexes

With the goal of accelerating the discovery of small molecule–protein complexes, we leverage fast, low-dose, event-based electron counting microcrystal electron diffraction (MicroED) data collection and native mass spectrometry. This approach, which we term electron diffraction with native mass spectrometry (ED-MS), allows assignment of protein target structures bound to ligands with data obtained from crystal slurries soaked with mixtures of known inhibitors and crude biosynthetic reactions. This extends to libraries of printed ligands dispensed directly onto TEM grids for later soaking with microcrystal slurries, and complexes with noncovalent ligands. ED-MS resolves structures of the natural product, epoxide-based cysteine protease inhibitor E-64, and its biosynthetic analogs bound to the model cysteine protease, papain. It further identifies papain binding to its preferred natural products, by showing that two analogs of E-64 outcompete others in binding to papain crystals, and by detecting papain bound to E-64 and an analog from crude biosynthetic reactions, without purification. ED-MS also resolves binding of the CTX-M-14 β-lactamase, a target of active drug development, to the non-β-lactam inhibitor, avibactam, alone or in a cocktail of unrelated compounds. These results illustrate the utility of ED-MS for natural product ligand discovery and for structure-based screening of small molecule binders to macromolecular targets, promising utility for drug discovery.

MicroED↗

Molecular beam mass spectrometry measurements of vibrationally excited N 2 in the effluent of an atmospheric plasma jet: a comparison with a state-to-state kinetic model

Vibrationally excited N 2 molecules are suggested to be one of the possible key species responsible for the observed synergistic effects in plasma catalysis for NH 3 synthesis. To assess the impact of vibrationally excited species in plasma-catalysis, quantitative measurements near interfaces are required, which remains challenging. In this letter, we report spatially resolved measurements of vibrationally excited N 2 in the effluent of an atmospheric pressure plasma jet by molecular beam mass spectrometry (MBMS). The mass spectrometry signals as a function of electron energy of the ionizer were fitted with the effective electron-impact ionization cross section of N 2 (v) considering the vibrational distribution function as determined by a detailed vibrational level resolved plasma kinetic calculation. Here, the reported method presented in this letter shows the capability of MBMS to measure vibrationally excited species of N 2 near interfaces when the vibrational distribution function is known or assumed and shows excellent agreement with state-to-state kinetic models of N 2 (v).

42 ENGINEERING↗

MS2Planner: improved fragmentation spectra coverage in untargeted mass spectrometry by iterative optimized data acquisition

Motivation: Untargeted mass spectrometry experiments enable the profiling of metabolites in complex biological samples. The collected fragmentation spectra are the metabolite’s fingerprints that are used for molecule identification and discovery. Two main mass spectrometry strategies exist for the collection of fragmentation spectra: data-dependent acquisition (DDA) and data-independent acquisition (DIA). In the DIA strategy, all the metabolites ions in predefined mass-to-charge ratio ranges are co-isolated and co-fragmented, resulting in multiplexed fragmentation spectra that are challenging to annotate. In contrast, in the DDA strategy, fragmentation spectra are dynamically and specifically collected for the most abundant ions observed, causing redundancy and sub-optimal fragmentation spectra collection. Yet, DDA results in less multiplexed fragmentation spectra that can be readily annotated. Results: We introduce the MS2Planner workflow, an Iterative Optimized Data Acquisition strategy that optimizes the number of high-quality fragmentation spectra over multiple experimental acquisitions using topological sorting. Our results showed that MS2Planner increases the annotation rate by 38.6% and is 62.5% more sensitive and 9.4% more specific compared to DDA. Availability and implementation MS2Planner code is available at https://github.com/mohimanilab/MS2Planner. The generation of the inclusion list from MS2Planner was performed with python scripts available at https://github.com/lfnothias/IODA_MS.

47 OTHER INSTRUMENTATION↗

Hydroxyl radical mediated damage of proteins in low oxygen solution investigated using X-ray footprinting mass spectrometry

In the method of X-ray footprinting mass spectrometry (XFMS), proteins at micromolar concentration in solution are irradiated with a broadband X-ray source, and the resulting hydroxyl radical modifications are characterized using liquid chromatography mass spectrometry to determine sites of solvent accessibility. These data are used to infer structural changes in proteins upon interaction with other proteins, folding, or ligand binding. XFMS is typically performed under aerobic conditions; dissolved molecular oxygen in solution is necessary in many, if not all, the hydroxyl radical modifications that are generally reported. In this study we investigated the result of X-ray induced modifications to three different proteins under aerobic versus low oxygen conditions, and correlated the extent of damage with dose calculations. We observed a concentration-dependent protecting effect at higher protein concentration for a given X-ray dose. For the typical doses used in XFMS experiments there was minimal X-ray induced aggregation and fragmentation, but for higher doses we observed formation of covalent higher molecular weight oligomers, as well as fragmentation, which was affected by the amount of dissolved oxygen in solution. The higher molecular weight products in the form of dimers, trimers, and tetramers were present in all sample preparations, and, upon X-ray irradiation, these oligomers became non-reducible as seen in SDS-PAGE. The results provide an important contribution to the large body of X-ray radiation damage literature in structural biology research, and will specifically help inform the future planning of XFMS, and well as X-ray crystallography and small-angle X-ray scattering experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Inspection of next-generation EUV resists with nano-projectile secondary ion mass spectrometry

There is a rapidly growing need for new materials for extreme ultraviolet (EUV) lithography, which incorporate high EUV absorbing elements. Hybrid resists, which are a combination of inorganic and organic moieties, are promising as they offer both high EUV sensitivity and high etch resistance. However, there is a glaring lack of methods to examine the uniformity of these important materials at the nanoscale. We examine the capabilities of nano-projectile secondary ion mass spectrometry (NP-SIMS) to investigate hybrid resists. NP-SIMS is a mass spectrometry-based technique with high lateral resolution. Using NP-SIMS, a surface is probed stochastically with a suite of individual projectiles, 10 6 to 10 7 in total, separated in time and space. Examining these individual mass spectra allows for nanoscale investigation of the uniformity of the surface. We evaluated the performance of NP-SIMS using samples of poly(methyl methacrylate) (PMMA) infiltrated with varying amounts of InO x via vapor-phase infiltration (VPI), an organic–inorganic hybridization method derived from atomic layer deposition. Here, we found that NP-SIMS measurements contained abundant characteristic ions related to both the PMMA and infiltrated In. The intensity of In atomic ions increased linearly with the number of infiltration cycles; however, the uniformity of In and PMMA varied with the number of infiltration cycles. After one cycle, we found that both the PMMA and In were relatively inhomogeneous. The homogeneity improved with subsequent infiltration cycles. In addition, NP-SIMS measurements contained characteristic ions related to the infiltration reaction and provided insights into the VPI mechanism. Overall, the results show that NP-SIMS is capable of examining both the inorganic and organic moieties in a hybrid resist and will be an important method for understanding the performance of these materials for use in EUV lithography.

36 MATERIALS SCIENCE↗