At least 109 records · Page 6

Review - Axial compressor stall phenomena

Stall in compressors can be associated with the initiation of several types of fluid dynamic instabilities. These instabilities and the different phenomena, surge and rotating stall, which result from them, are discussed in this paper. Assessment is made of the various methods of predicting the onset of compressor and/or compression system instability, such as empirical correlations, linearized stability analyses, and numerical unsteady flow calculation procedures. Factors which affect the compressor stall point, in particular inlet flow distortion, are reviewed, and the techniques which are used to predict the loss in stall margin due to these factors are described. The influence of rotor casing treatment (grooves) on increasing compressor flow range is examined. Compressor and compression system behavior subsequent to the onset of stall is surveyed, with particular reference to the problem of engine recovery from a stalled condition. The distinction between surge and rotating stall is emphasized because of the very different consequences on recoverability. The structure of the compressor flow field during rotating stall is examined, and the prediction of compressor performance in rotating stall, including stall/unstall hysteresis, is described.

Greitzer, E. M.↗

Task II: Three-dimensional Rotating Stall Inception and Effects of Rotating Tip Clearance Asymmetry in Axial Compressors

The effects of two types of flow non-uniformity on stall inception behavior were assessed with linearized stability analyses of two compressor flow models. Response to rotating tip clearance asymmetries induced by a whirling rotor shaft or rotor height variations were investigated with a two-dimensional flow model. A 3-D compressor model was also developed to study the stability of both full-span and part-span rotating stall modes in annular geometries with radial flow variations. The studies focussed on (1) understanding what compressor designs were sensitive to these types of circumferential and spanwise flow non-uniformities, and (2) situations where 2-D stability theories were inadequate because of 3-D flow effects. Rotating tip clearance non-uniformity caused the greatest performance loss for shafts whirling at the rotating stall frequency. A whirling shaft displacement of 1 percent chord caused the stalling mass flow to rise by as much as 10 percent and the peak pressure rise to decrease by 6 percent. These changes were an order of magnitude larger than for equivalent-sized stationary or rotor-locked clearance asymmetries. Spanwise flow non-uniformity always destabilized the compressor, so that 2-D models over-predicted that stall margin compared to 3-D theory. The difference increased for compressors with larger spanwise variations of characteristic slope and reduced characteristic curvature near the peak. Differences between 2-D and 3-D stall point predictions were generally unacceptable (2 - 4 percent of flow coefficient) for single-stage configurations, but were less than 1 percent for multistage compressors. 2-D analyses predicted the wrong stall mode for specific cases of radial inlet flow distortion, mismatching and annulus area contraction, where higher-order radial modes led to stall. The stability behavior of flows with circumferential or radial non-uniformity was unified through a single stability criterion. The stall point for both cases was set by the integral around the annulus of the pressure rise characteristic slope, weighted by the amplitude of the mode shape. For the case of steady circumferential variations, this criterion reduced to the integrated mean slope (IMS) condition associated with steady inlet distortions. The rotating tip clearance asymmetry model was also used to demonstrate the feasibility of actively controlling the shaft position to suppress rotating stall. In axisymmetric mean flow, this method only stabilized the first harmonic mode, increasing the operating range until surge or higher harmonic modes became unstable.

Suder, Kenneth↗

Effect of Variable Chord Length on Transonic Axial Rotor Performance Investigated

During the life of any gas turbine, blade erosion is present, especially for those units that are exposed to unfiltered air, such as aviation turbofan engines. The effect of this erosion is to reduce the blade chord progressively from the midspan to the tip region and to roughen and distort the blade surface. The effects of roughness on rotor performance have been documented by Suder et al. and Roberts. These papers indicate that the penalty for leading-edge roughness and erosion can be significant. Turbofan operators, therefore, restore chord length at routine maintenance intervals to regain performance before deterioration is too severe to salvage blades. As the rotor blades erode, the leading edge becomes rough - blunt and distorted from the nominal shape - and the aerodynamic performance suffers. Nominal performance can be recovered by recontouring the leading edges. This process, which inherently shortens the blade chord, can be used until the blade chord erodes to the stall limit. Below this chord length, which varies among engine-compressor types, a decrease of stall margin is likely. After compressor blade rework that includes leading edge recontouring, the blades have different chord lengths, ranging from blades that are near nominal chord length down to those near the stall chord limit. Furthermore, as blades erode below the stall limit, they must be replaced with new blades that have the full nominal chord length. Consequently, a set of compressor blades with varying chord lengths will be installed into each turbofan engine that goes through a complete maintenance cycle. The question arises, "Does fan or compressor performance depend on the order in which mixed-chord blades are installed into a fan or compressor disk?"

Suder, Kenneth L.↗

An Automated Stall-Speed Warning System

The NASA Dryden Flight Research Facility embarked upon a project with the United States Army Aviation Engineering Flight Activity (USAAEFA) to develop and test a stall-speed warning system. NASA designed and built an automated stall-speed warning system which presents both airspeed and stall speed to the pilot. The airspeed and stall speed are computed in real time by monitoring the basic aerodynamic parameters {dynamic pressure, horizontal and vertical accelerations, and pressure altitude) and other parameters (elevator and flap positions, engine torques, and fuel flow). In addition, an aural warning at predetermined stall margins is presented to the pilot through a voice synthesizer. Once the system was designed and installed in the aircraft, a flight-test program of less than 20 hr was anticipated to determine the stall-speed software coefficients. These coefficients would then be inserted in the system's software and then test flown over a period of about 10 hr for the purposes of evaluation.

Pilot↗

An Automated Stall-Speed Warning System

The NASA Dryden Flight Research Facility embarked upon a project with the United States Army Aviation Engineering Flight Activity (USAAEFA) to develop and test a stall-speed warning system. NASA designed and built an automated stall-speed warning system which presents both airspeed and stall speed to the pilot. The airspeed and stall speed are computed in real time by monitoring the basic aerodynamic parameters (dynamic pressure, horizontal and vertical accelerations, and pressure altitude) and other parameters (elevator and flap positions, engine torques, and fuel flow). In addition, an aural warning at predetermined stall margins is presented to the pilot through a voice synthesizer. Once the system was designed and installed in the aircraft, a flight-test program of less than 20 hr was anticipated to determine the stall-speed software coefficients. These coefficients would then be inserted in the system's software and then test flown over a period of about 10 hr for the purposes of evaluation.

Dynamic Pressure↗

A proposed simple and safe aircraft take-off or landing procedure with wing roughness or protuberances

A simple, safe takeoff and/or landing procedure has been developed for cases of wing roughness or proturbances. The procedure utilizes calculations of aerodynamic penalties and steady flight equations. Empirical relationships for lift, drag, and angle of attack penalties are used to construct the lift and drag coefficient versus the angle of attack. To maintain safe stall margin due to wing roughness, the lift coefficient and the angle of attack at takeoff or landing for a roughened aircraft must be less than that of a clean aircraft by the relative maximum lift loss and stall angle loss due to roughness. The procedure may be applied to many types of aircraft.

Dietenberger, M. A.↗

Investigation of Unsteady Flow Interaction Between an Ultra-Compact Inlet and a Transonic Fan

In the study presented, unsteady flow interaction between an ultra-compact inlet and a transonic fan stage is investigated. Future combat aircraft engines require ultra-compact inlet ducts as part of an integrated, advanced propulsion system to improve air vehicle capability and effectiveness to meet future mission needs. The main purpose of the current study is to advance the understanding of the flow interaction between a modern ultra-compact inlet and a transonic fan for future design applications. Many experimental/ analytical studies have been reported on the aerodynamics of compact inlets in aircraft engines. On the other hand, very few studies have been reported on the effects of flow distortion from these inlets on the performance of the following fan/compressor stages. The primary goal of the study presented is to investigate how flow interaction between an ultra-compact inlet and a transonic compressor influence the operating margin of the compressor. Both Unsteady Reynolds-averaged Navier-Stokes (URANS) and Large Eddy Simulation (LES) approaches are used to calculate the unsteady flow field, and the numerical results are used to study the flow interaction. The present study indicates that stall inception of the following compressor stage is affected directly based on how the distortion pattern evolves before it interacts with the fan/compressor face. For the present compressor, the stall initiates at the tip section with clean inlet flow and distortion pattern away from the casing itself seems to have limited impacts on the stall inception of the compressor. A counter-rotating swirl, which is generated due to flow separation inside the s-shaped compact duct, generates an increased flow angle near the blade tip. This increased flow angle near the rotor tip due to the secondary flow from the counter-rotating vortices is the primary reason for the reduced compressor stall margin.

Compressor↗

Formulation of a distortion index based on peak compressor pressure ratios

In order to effectively use a compressor face total-pressure distortion index as a measure of inlet-engine compatibility, a correlation of distortion amplitude with stall margin must be developed with minimal scatter. A recent analysis of data recorded in extensive distortion screen tests with the J85-GE-13 turbojet engine has resulted in a correlation based on compressor discharge pressure ratioed to the minimum pressure at the compressor face. Simply by determining compressor stall lines with a single hub radial distortion pattern, a single tip radial pattern, and with undistorted inflow, the overall compressor pressure ratio at stall for even the most complex distortion pattern was found to be predictable.

Calogeras, J. E.↗

Formulation of a distortion index based on peak compressor pressure ratios

In order to effectively use a compressor face total-pressure distortion index as a measure of inlet-engine compatibility, a correlation of distortion amplitude with stall margin must be developed with minimal scatter. A recent analysis of data recorded in extensive distortion screen tests with the J85-GE-13 turbojet engine has resulted in a correlation based on compressor discharge pressure ratioed to the minimum pressure at the compressor face. Simply by determining compressor stall lines with a single hub radial distortion pattern, a single tip radial pattern, and with undistorted inflow, the overall compressor pressure ratio at stall for even the most complex distortion pattern was found to be predictable.

Calogeras, J. E.↗

Turbine Electrified Energy Management for Single Aisle Aircraft

Electrified aircraft propulsion technology is being developed to reduce the environmental impacts of the aviation industry. This is prompting the exploration of potential uses and benefits of hybrid systems in which electric powertrains are integrated with more traditional gas turbine propulsion systems. Turbine Electrified Energy Management (TEEM) is an energy management approach for hybrid-electric architectures in which electric machines are connected to the turbofan shafts and used to suppress the off-design operation naturally associated with engine transients. This reduces the need to maintain a large amount of compressor operability margin, thus allowing further exploration of the engine design space. In this study, a 19,000 lbf engine within a parallel hybrid propulsion system is considered along with a 30,000 lbf standalone engine. Data from prior TEEM applications are used to approximate the electric machine sizing required to achieve operability benefits. The TEEM controller is shown to improve operability during transients through the reduction of stall margin undershoots and the decrease of transient variations in component performance maps by over 29%.

Controls↗

Turbine Electrified Energy Management for Single Aisle Aircraft

Electrified aircraft propulsion technology is being developed to reduce the environmental impacts of the aviation industry. This is prompting the exploration of potential uses and benefits of hybrid systems in which electric powertrains are integrated with more traditional gas turbine propulsion systems. Turbine Electrified Energy Management (TEEM) is an energy management approach for hybrid-electric architectures in which electric machines are connected to the turbofan shafts and used to suppress the off-design operation naturally associated with engine transients. This reduces the need to maintain a large amount of compressor operability margin, thus allowing further exploration of the engine design space. In this study, a 19,000 lbf engine within a parallel hybrid propulsion system is considered along with a 30,000 lbf standalone engine. Data from prior TEEM applications are used to approximate the electric machine sizing required to achieve operability benefits. The TEEM controller is shown to improve operability during transients through the reduction of stall margin undershoots and the decrease of transient variations in component performance maps by over 29%.

EAP↗

Dynamic Analysis for a Geared Turbofan Engine with Variable Area Fan Nozzle

Aggressive design goals have been set for future aero-propulsion systems with regards to fuel economy, noise, and emissions. To meet these challenging goals, advanced propulsion concepts are being explored and current operating margins are being re-evaluated to find additional concessions that can be made. One advanced propulsion concept being evaluated is a geared turbofan with a variable area fan nozzle (VAFN), developed by NASA. This engine features a small core, a fan driven by the low pressure turbine through a reduction gearbox, and a shape memory alloy (SMA)-actuated VAFN. The VAFN is designed to allow both a small exit area for efficient operation at cruise, while being able to open wider at high power conditions to reduce backpressure on the fan and ensure a safe level of stall margin is maintained. The VAFN is actuated via a SMA-based system instead of a conventional system to decrease overall weight of the system, however, SMA-based actuators respond relatively slowly, which introduces dynamic issues that are investigated in this work. This paper describes both a control system designed specifically for issues associated with SMAs, and dynamic analysis of the geared turbofan VAFN with the SMA actuators. Also, some future recommendations are provided for this type of propulsion system.

N+3↗

Effect of several porous casing treatments on stall limit and on overall performance of an axial flow compressor rotor

Several geometrically different porous casings were tested with an axial-flow compressor rotor to determine their effects upon the rotor stall-limit line and overall performance. The tests were conducted using both uniform and nonuniform inlet-flow conditions. The rotor performance with the various casing treatments is compared with that obtained with a solid casing. The ability of the various casing treatments to displace the rotor stall-limit line to lower weight flows was observed. Significant stall-margin increases were obtained with several of the porous casings. Peak efficiencies with two of the porous casings were as high as or slightly higher than that obtained with solid casing.

Osborn, W. M.↗

Comparison of the effect of two damper sizes on the performance of a low-solidity axial-flow transonic compressor rotor

The experimental performance of a 20-inch-diameter axial-flow transonic compressor rotor with small dampers is presented. The compressor rotor was tested earlier with large dampers which were twice in size, and comparisons of overall performance and radial distributions of selected flow and performance parameters are made. The rotor with small dampers experienced lower losses in the damper region which resulted in locally higher values of temperature rise efficiency and total pressure ratio. However, there was no appreciable effect on overall efficiency and pressure ratio. A greater stall margin was measured for the rotor with small dampers at design speed, but at 70 and 90 percent of design speed the rotor with large dampers had somewhat greater flow range.

Lewis, G. W., Jr.↗

Performance of a single-stage transonic compressor with a blade-tip solidity of 1.3

The design and experimental performance of a 50-centimeter-diameter, single stage, axial flow, transonic compressor with a blade tip solidity of 1.3 are presented. Radial surveys were made of the flow conditions for both the rotor and stator. At design speed, peak efficiencies for both rotor and stage were 0.87 and 0.82, respectively, and occurred at an equivalent weight flow of 29.6 kilograms per second (202 kg/sec/sq m of annulus area). At peak efficiency, the total pressure ratios for both rotor and stage were 1.79 and 1.73, respectively. Stall margin for the stage was 17 percent.

Urasek, D. C.↗

Performance of a single-stage axial-flow transonic compressor stage with a blade tip solidity of 1.7

The overall and blade-element performance of a transonic compressor stage is presented over the stable operating range at rotative speeds from 50 to 100 percent of design speed. Stage peak efficiency of 0.784 was obtained at a weight flow of 28.6 kilograms per second and a pressure ratio of 1.706. Stall margin at design speed was 11.4 percent. The peak efficiency being significantly less than design efficiency was attributed to: (1) the stator loss and the radial gradient of losses being much higher than design, (2) the losses and blockages associated with the rotor part-span dampers not being incorporated into the design, and (3) mismatch of the rotor and stator badle elements.

Moore, R. D.↗

Performance of a single-stage transonic compressor with a blade-tip solidity of 1.5 and comparison with 1.3 and 1.7 solidity stages

The overall and blade-element performance of a transonic compressor stage with a tip solidity of 1.5 is presented over the stable operating range at rotative speeds from 50 to 100 percent of design speed. State peak efficiency of 0.82 was obtained at a weight flow of 29.4 kg.sec (200.4 (kg/sec)/m2 of annulus area) and a pressure ratio of 1.71. Stall margin at design speed was 14 percent. A comparison of three stages in a solidity study showed that the performance of the 1.5 solidity stage and the 1.3 solidity stage were nearly identical but that the performance of the 1.7 solidity stage was significantly lower.

Osborn, W. M.↗