Search NASA⌕ Search

SEARCH · Search NASA

Results for “Structured scintillator”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Electronic structure, optical properties and bonding in alkaline earth halo-fluoride scintillators: BaClF, BaBrF and BaIF

We report first-principles studies of the structural, electronic, and optical properties of the alkaline-earth halofluorides, BaXF (X = Cl, Br, and I), including pressure dependence of structural properties. The band structures show clear separation of the halogen p derived valence bands into higher binding energy F and lower binding energy X derived manifolds reflecting the very high electronegativity of F relative to the other halogens. Implications of this for bonding and other properties are discussed. We find an anisotropic behavior of the structural parameters especially of BaIF under pressure. The optical properties on the other hand are almost isotropic, in spite of the anisotropic crystal structures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Antennas and Propagation; Proceedings of the International Conference, 8th, Heriot-Watt Univeristy, Edinburgh, UK, Mar. 30 - Apr. 2, 1993. Vols. 1 & 2

Conference papers from sessions on the following topics are presented: satellite antennas; modal analysis of transmission line structures; fading and scintillation; microcellular; numerical analysis; Olympus; indoor mobile; mechanical aspects of satellite antennas; flat plate and printed antennas; fade counter measures; electromagnetic theory; feeds for satellites; antennas for personal communications; frequency selected surfaces; remote sensing; active patch antennas; antenna measurements; clear air/trans horizon; high frequency system and noise; rain attenuation and rain scatter; and high frequency direction finding.

Source record↗

Fine-Scale Filamentary Structure in Coronal Streamers

Doppler scintillation measurements of a coronal streamer lasting several solar rotations have been conducted by Ulysses in 1991 over a heliocentric distance range of 14-77 R(sub 0). By showing that the solar corona is filamentary, and that Doppler frequency is the radio counterpart of white-light eclipse pictures processed to enhance spatial gradients, it is demonstrated that Doppler scintillation measurements provide the high spatial resolution that has long eluded white-light coronagraph measurements. The region of enhanced scintillation, spanning an angular extent of 1.8 deg in heliographic longitude, coincides with the radially expanding streamer stalk and represents filamentary structure with scale sizes at least as small as 340 km (0.5 sec) when extrapolated to the Sun. Within the stalk of the streamer, the fine-scale structure corresponding to scale sizes in the range of 20-340 km at the Sun and associated with closed magnetic fields amounts to a few percent of the mean density, while outside the stalk, the fine-scale structure associated with open fields is an order of magnitude lower. Clustering of filamentary structure that takes place within the stalk of the streamer is suggestive of multiple current sheets. Comparison with ISEE 3 in situ plasma measurements shows that significant evolution resulting from dynamic interaction with increasing heliocentric distance takes place by the time streamers reach Earth orbit.

Woo, Richard↗

Role of Multiple Charge States of Ce in the Scintillation of AB O 3 Perovskites

Ce-activated A 2+ B 4+ O 3 perovskites represent a class of compounds currently under active exploration for their potential as scintillators. Depending on the chemistry and synthesis conditions, perovskites can crystallize in multiple crystal structures, and a Ce substitutional dopant in an ABO 3 perovskite can adopt different charge states (i.e., Ce 3+ or Ce 4+ ) as well as different substitutional sites (namely, the 12-fold-coordinated A site or the octahedrally coordinated B site). We use first-principles density-functional-theory- and hybrid-functional-based computations to study relative trends in the structure, energetics, and electronic structure of bulk ABO 3 perovskites, where A = Ca, Sr, or Ba and B = Hf or Zr. Subsequently, we consider the relative energetics of preferential solution sites for Ce as a function of charge states, chemical potential, and defect configurations. Our results reveal that while Ce 3+ or Ce 4+ defects can be thermodynamically stable, depending on the choice of the substitutional site and synthesis conditions (i.e., prevailing chemical potential), only Ce 3+ dopant at the A site leads to an electronic structure that can exhibit scintillation. Our comparative analysis shows that while the positions of the 5 d 1 and 4$\mathcal{f}$ levels of Ce 3+ as a dopant at the A site are favorably placed in the band structure, these levels are consistently higher for the Ce 4+ charge state and are unlikely to manifest any luminescence. The findings of this study are also discussed in relation to previously reported results and display excellent agreement with past experimental observations. In general, it is demonstrated that control of the Ce charge state and local chemical environment can be used—in addition to band-gap and band-edge engineering—to manipulate the relative position of scintillating states with respect to the valence-band maximum and conduction-band minimum. While this study specifically focuses on perovskites, the results (in particular, the relative alignment of the positions of the 5 d 1 and 4$\mathcal{f}$ levels of Ce dopant as a function of the activator’s charge state) are expected to be general and thus transferable to other chemistries.

36 MATERIALS SCIENCE↗

Performance of BaFCl:Eu2+ scintillating composites for X-ray imaging screens

A cost-effective solution for improving X-ray imaging detectors is presented through the use of a translucent scintillating composite and pixelated screen structure. A large quantity of BaFCl:Eu 2+ polycrystalline scintillator powder was synthesized via flux growth and its optical properties characterized through photoluminescence (PL) and absolute quantum yield (QY). UV-curable composites containing the BaFCl:Eu 2+ material were fabricated with differing amounts of NOA1665 and NOA170 optical adhesives. It was determined that, when the two resins were combined, the translucency of the resulting composite could be enhanced. The BaFCl:Eu 2+ composite was also cast into a pixelated glass screen containing an array of 160 μm x 160 μm holes by two separate methods: composite paste application and powder-resin application. Based on visual inspection, using a composite paste to fill the apertures proved to be more effective in creating a uniform packing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Production summary for extended barrel module fabrication at Argonne for the ATLAS tile calorimeter.

The Tile Calorimeter is one of the main hadronic calorimeters to be used in the ATLAS experiment at CERN [1,2]. It is a steel/scintillator sampling calorimeter which is built by stacking 64 segments in azimuth and 3 separate cylinders to provide a total structure whose length is approximately 12m and whose diameter is a little over 8.4m. It has a total weight of about 2630 metric tons. Important features of this calorimeter are: A minimum gap (1.5mm) between modules in azimuth; Pockets in the structure to hold the scintillator tiles; Recessed channels at the edges of the module into which the readout fibers will sit; and Holes in the structure through which a radioactive source will pass. The mechanical structure for one of the 3 calorimeter sections, the Extended Barrel (EBA) was constructed at Argonne. A schematic of the calorimeter sampling structure and the layout of one of the 64 segments, termed a module, are shown in figure 1. Each module comprises mechanically of a precision machined, structural girder to which 10 submodules are bolted. One of these submodules, the ITC, has a customized shape to accommodate services for other detector elements. Each submodule weighs 850Kg and the assembled mechanical structure of the module weighs approximately 9000Kg (a fully instrumented Extended Barrel modules weighs {approx}9600Kg). A crucial issue for the tile calorimeter assembly is the minimization of the un-instrumented gap between modules when they are stacked on top of each other during final assembly. The design goal was originally 1mm gap which was eventually relaxed to 1.5mm following a careful evaluation of all tolerances in the construction and assembly process as shown in figure 2 [3]. Submodules for this assembly were produced at 4 locations [4] using tooling and procedures which were largely identical [5]. An important issue was the height of each submodule on the stacking fixture on which they were fabricated as this defines the length along the girder for installation, with a design gap between submodules on the girder of 0.3mm. During production we relaxed this tolerance to +0.3, -1.5mm. The height summary for submodules used at Argonne is shown in Appendix I. About 10 submodules fell outside the positive height envelope (due to the raw plate thickness being out of specification) and we constructed some custom short submodules to allow their use in module assembly. The structural girders were produced commercially following the Quality Control plan agreed to with the Tile Calorimeter collaboration and shipped to Argonne. The crucial tolerances on the girder are the key into which submodules are placed as well as the flatness of the key surface which are used in aligning submodules such that the azimuthal surface lies wholly an envelope of +0.75mm from nominal [6]. Another important characteristic of the girder are clearance holes through which the wavelength shift fibers pass to couple the light to photomultipliers located inside the girder, as described in [2]. Since these fiber bundles must be located to high precision, rather than position the holes in the steel to this precision, tooling was developed by which the precision pieces are glued into the girder [7]. This is shown in figure 3. More details on the pieces used to accomplish this interface to the readout electronics are discussed in [2].

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Toward “super-scintillation” with nanomaterials and nanophotonics

Abstract Following the discovery of X-rays, scintillators are commonly used as high-energy radiation sensors in diagnostic medical imaging, high-energy physics, astrophysics, environmental radiation monitoring, and security inspections. Conventional scintillators face intrinsic limitations including a low extraction efficiency of scintillated light and a low emission rate, leading to efficiencies that are less than 10 % for commercial scintillators. Overcoming these limitations will require new materials including scintillating nanomaterials (“nanoscintillators”), as well as new photonic approaches that increase the efficiency of the scintillation process, increase the emission rate of materials, and control the directivity of the scintillated light. In this perspective, we describe emerging nanoscintillating materials and three nanophotonic platforms: (i) plasmonic nanoresonators, (ii) photonic crystals, and (iii) high-Q metasurfaces that could enable high performance scintillators. We further discuss how a combination of nanoscintillators and photonic structures can yield a “super scintillator” enabling ultimate spatio-temporal resolution while enabling a significant boost in the extracted scintillation emission.

Carr Delgado, Hamish↗

Gravity waves in Titan's atmosphere

Scintillations (high frequency variations) observed in the radio signal during the occultation of Voyager 1 by Titan (Hinson and Tyler, 1983) provide information concerning neutral atmospheric density fluctuations on scales on hundreds of meters to a few kilometers. Those seen at altitudes higher than 25 km above the surface were interpreted by Hinson and Tyler as being caused by linear, freely propagating (energy-conserving) gravity waves, but this interpretation was found to be inconsistent with the scintillation data below the 25-km altitude level. Here an attempt is made to interpret the entire scintillation profile between the surface and the 90-km altitude level in terms of gravity waves generated at the surface. Numerical calculations of the density fluctuations caused by two-dimensional, nonhydrostatic, finite-amplitude gravity waves propagating vertically through Titan's atmosphere are performed to produce synthetic scintillation profiles for comparison with the observations. The numerical model accurately treats the effects of wave transience, nonlinearity, and breakdown due to convective instability in the overturned part of the wave. The high-altitude scintillation data were accurately recovered with a freely propagating wave solution, confirming the analytic model of Hinson and Tyler. It is found that the low-altitude scintillation data can be fit by a model where a component of the gravity waves becomes convectively unstable and breaks near the 15 km level. The large-scale structure of the observed scintillation profile in the entire altitude range between 5 and 85 km can be simulated by a model where the freely propagating and breaking waves are forced at the surface simultaneously. Further analysis of the Voyager 1 Titan low-altitude scintillation data, using inversion theory appropriate for strong scattering, could potentially remove some of the ambiguities remaining in this analysis and allow a better determination of the strength and source of the waves.

Friedson, A. James↗

IPS observations of heliospheric density structures associated with active regions

Interplanetary scintillation (IPS) measurements of the 'disturbance factor' g, obtained with the Cambridge (UK) array can be used to explore the heliospheric density structure. We have used these data to construct synoptic (Carrington) maps, representing the large-scale enhancements of the g-factor in the inner heliosphere. These maps emphasize the stable corotating, rather than the transient heliospheric density enhancements. We have compared these maps with Carrington maps of Fe XIV observations National Solar Observatory ((NSO), Sacramento Peak) and maps based on Yohkoh Soft X-Ray Telescope (SXT) X-ray observations. Our results indicate that the regions of enhanced g tend to map to active regions rather than the current sheet. The implication is that act ve regions are the dominant source of the small-scale (approximately equal 200 km) density variations present in the quiet solar wind.

Hick, P.↗

Mixed Material Scintillator Systems Particle ID Modelling Report

AMixed-Material Scintillator System (MMSS) is a radiation detector using a scintillator made of a heterogeneous, structured mixture of two or more materials. MMSSs are designed so that the structured mixing of materials encodes properties of the radiation detected in the scintillator. This allows for new radiation detectors with advantages over detectors using traditional homogeneous scintillators. This report contains results from this project’s second task, to model and quantify the promise of the MMSSs invented earlier in the project. Those inventions have been divided into two categories, and this report focuses on the first category: MMSS inventions the use zones of differently-colored scintillators to detect and characterize neutron sources. We call this category particle-ID, or PID, detectors. Inventions using gradients designed to encode the position of radiation interactions using gradients will be discussed in a future report.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Mixed Material Scintillator Systems Position Reconstruction Modelling Report

A Mixed-Material Scintillator System (MMSS) is a radiation detector using a scintillator made of a heterogeneous, structured mixture of two or more materials. MMSSs are designed so that the structured mixing of materials encodes properties of the radiation detected in the scintillator. This allows for new radiation detectors with advantages over detectors using traditional homogeneous scintillators.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Status Update for the MINER$\nu$A Experiment

MINER{nu}A (Main INjEctoR {nu}-A) is a few-GeV neutrino cross section experiment that began taking data in the FNAL NuMI beam-line in the fall of 2009. MINER{nu}A employs a fine-grained detector capable of complete kinematic characterization of neutrino interactions. The detector consists of an approximately 6.5 ton active target region composed of plastic scintillator with additional carbon, iron, and lead targets upstream of the active region. The experiment will provide important inputs for neutrino oscillation searches and a pure weak probe of nuclear structure. Here we offer a set of initial kinematic distributions of interest and provide a general status update.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Outflow structure of the quiet sun corona probed by spacecraft radio scintillations in strong scattering

Radio scintillation observations have been unable to probe flow speeds in the low corona where the scattering of radio waves is exceedingly strong. Here we estimate outflow speeds continuously from the vicinity of the Sun to the outer corona (heliocentric distances of 1.5-20.5 solar radii) by applying the strong scattering theory to radio scintillations for the first time, using the Akatsuki spacecraft as the radio source. Small, nonzero outflow speeds were observed over a wide latitudinal range in the quiet-Sun low corona, suggesting that the supply of plasma from closed loops to the solar wind occurs over an extended area. The existence of power-law density fluctuations down to the scale of 100 m was suggested, which is indicative of well-developed turbulence which can play a key role in heating the corona. At higher altitudes, a rapid acceleration typical of radial open fields is observed, and the temperatures derived from the speed profile show a distinct maximum in the outer corona. This study opened up a possibility of observing detailed flow structures near the Sun from a vast amount of existing interplanetary scintillation data.

79 ASTRONOMY AND ASTROPHYSICS↗

SAPHIRE (scintillator avalanche photoconductor with high resolution emitter readout) for low dose x-ray imaging: Spatial resolution

An indirect flat panel imager (FPI) with programmable avalanche gain and field emitter array (FEA) readout is being investigated for low-dose and high resolution x-ray imaging. It is made by optically coupling a structured x-ray scintillator, e.g., thallium (Tl) doped cesium iodide (CsI), to an amorphous selenium (a-Se) avalanche photoconductor called high-gain avalanche rushing amorphous photoconductor (HARP). The charge image created by the scintillator/HARP (SHARP) combination is read out by the electron beams emitted from the FEA. The proposed detector is called scintillator avalanche photoconductor with high resolution emitter readout (SAPHIRE). The programmable avalanche gain of HARP can improve the low dose performance of indirect FPI while the FEA can be made with pixel sizes down to 50 {mu}m. Because of the avalanche gain, a high resolution type of CsI (Tl), which has not been widely used in indirect FPI due to its lower light output, can be used to improve the high spatial frequency performance. The purpose of the present article is to investigate the factors affecting the spatial resolution of SAPHIRE. Since the resolution performance of the SHARP combination has been well studied, the focus of the present work is on the inherent resolution of the FEA readout method. The lateral spread of the electron beam emitted from a 50 {mu}mx50 {mu}m pixel FEA was investigated with two different electron-optical designs: mesh-electrode-only and electrostatic focusing. Our results showed that electrostatic focusing can limit the lateral spread of electron beams to within the pixel size of down to 50 {mu}m. Since electrostatic focusing is essentially independent of signal intensity, it will provide excellent spatial uniformity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

WE-H-207A-01: Computational Evaluation of High-Resolution 18F Positron Imaging Using Radioluminescence Microscopy with Lu2O3: Eu Thin-Film Scintillator

Purpose: Radioluminescence microscopy, an emerging and powerful tool for high resolution beta imaging, has been applied to molecular imaging of cellular metabolism to understand tumor biology. A novel thin-film (10 µm thickness) scintillator made of Lu{sub 2}O{sub 3}: Eu has been developed to enhance the system performance. However the advances of radioluminescence imaging with Lu{sub 2}O{sub 3}scintillator compared with that using conventional scintillator have not been explored theoretically to date. To validate the advantages of the thin-film scintillator, this study uses a novel computational simulation framework to evaluate the performance of radioluminescence microscopy using both conventional and thin-film scintillators. Methods: Numerical models for different stages of positron imaging are established. Positron from {sup 18}F passing through the scintillator and its neighbor structures are modeled by Monte-Carlo simulation using Geant4. The propagation and focus of photons by the microscope are modeled by convolution with a depth-varying point spread function generated by the Gibson-Lanni model. Photons focused on the detector plane are then captured and converted into electronic signals by an electron multiplication (EM) CCD camera, which is described by a photosensor model considering various noises and charge amplification. Results: The performance metrics of radioluminescence imaging with a thin-film Lu{sub 2}O{sub 3} and conventional CdWO{sub 4} scintillator are compared, including spatial resolution, sensitivity, positron track area and intensity. The spatial resolution of Lu{sub 2}O{sub 3} system can achieve 10 µm maximally, a 12 µm enhancement from that obtained from CdWO{sub 4} system. Meanwhile, the system with Lu{sub 2}O{sub 3} scintillator can provide a higher mean sensitivity: 40% compared with that (21.5%) obtained from CdWO{sub 4} system. Moreover, the simulation results are in good agreement with previous experimental measurements. Conclusion: This study provides a new theoretical understanding of our imaging system and has the potential to promote the development of radioluminescence microscopy for more reliable and robust application on the functional imaging of delicate biological structures. The authors acknowledge funding from NIH grant R01CA186275 and SBIR grant 1R43GM110888-01.

60 APPLIED LIFE SCIENCES↗