Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Analysis of Tank 38H (HTF-38-21-95, -96) and Tank 43H (HTF-43-21-97, -98) Samples for Support of the Enrichment Control and Corrosion Control Programs

SRNL analyzed samples from Tank 38H and Tank 43H to support ECP and CCP. The results indicate the concentrations of most species in the Tank 38H surface sample increased from the previous surface sample. The Tank 38H sub-surface sample shows only minor changes in concentration for soluble species in the solution (e.g., Na, Al, Cs-137) relative to the previous sample, but a small decrease in concentrations for species typically associated with sludge solids (e.g., U, Pu, Fe, Si) likely because of a decrease in sludge solids from the previous sample. The large differences in the concentrations of major components between the Tank 38H surface and sub-surface samples indicate significant stratification of solution species within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Tank 9H Salt Dissolution Batch 2B in Support of Tank Closure Cesium Removal (TCCR) 1A Batch 2 Preparations

Savannah River Mission Completion (SRMC) is currently preparing the second batch of material to be processed through the Tank Closure Cesium Removal (TCCR) 1A system. The feed for TCCR 1A consists of dissolved saltcake from Tank 9H. The second batch of salt to make up processing Batch 2 (Batch 2B) has recently been dissolved in Tank 9H and transferred to Tank 10H where it was composited with the first part of the batch (Batch 2A) in preparation for processing through the TCCR 1A unit. Savannah River National Laboratory (SRNL) received samples from the recent batch (2B) of dissolved salt for characterization. Two samples from Batch 2B were received for characterization, a surface sample and a variable depth sample (VDS). Neither sample contained significant solids, although the VDS appeared slightly cloudy as compared to the surface sample. The sodium concentrations of both the surface and VDS filtrate samples were approximately 5.8 M, and the 137 Cs activity was 9.8E+07 dpm/mL in the surface sample and 9.5E+07 dpm/mL in the VDS. The total Cs concentrations were 2.5 mg/L and 2.4 mg/L in the surface sample and VDS, respectively, using the gamma activity and the Cs isotopic ratios determined by ICP-MS. The alpha activity was below the detection limit in both samples. Nitrate was the dominant anion present, and the samples were primarily concentrated sodium nitrate solutions with hydroxide, nitrite, and carbonate present at 0.1 – 0.2 M. In general, the Batch 2B samples were more dilute than the previously characterized Batch 2A samples.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Systems and methods for laser assisted sample transfer to solution for chemical analysis

Systems and methods are described for laser ablation of an analyte from a specimen and capturing of the analyte in a dispensed solvent to form a testing solution. A solvent dispensing and extraction system can form a liquid microjunction with the specimen. The solvent dispensing and extraction system can include a surface sampling probe. The laser beam can be directed through the surface sampling probe. The surface sampling probe can also serve as an atomic force microscopy probe. The surface sampling probe can form a seal with the specimen. The testing solution including the analyte can then be analyzed using an analytical instrument or undergo further processing.

47 OTHER INSTRUMENTATION↗

Analysis of Tank 38H (HTF-38-25-36, -32) and Tank 43H (HTF-43-25-33, -35) Samples for Support of the Enrichment Control and Corrosion Control Programs

Savannah River National Laboratory (SRNL) analyzed samples from Tank 38H and Tank 43H to support the Enrichment Control Program (ECP) and Corrosion Control Program (CCP). The results indicate the concentrations of most soluble species in the Tank 38H surface sample are similar to the previous Tank 38H surface sample. The current Tank 38H subsurface sample shows similar Na, free hydroxide, and anions in comparison to the previous subsurface sample. The current Tank 38H subsurface sample appears brown in color. Measurement of the wt.% insoluble solids in the Tank 38H subsurface sample and associated uncertainty analysis indicates that the calculated average wt.% insoluble solids is 5.5 ± 3.6 wt.%. Significant differences in the concentrations of major components between the Tank 38H surface and subsurface samples indicate stratification of solution species between these two locations within the Tank 38H. The current Tank 43H surface sample is ~ 10% diluted versus the previous Tank 43H surface sample and the Tank 43H subsurface sample is similar in composition to the previous Tank 43H subsurface sample. Information provided by SRMC on tank additions since the last ECP sampling indicates that a total of about 4,062 gallons of water was added to Tank 43H. This addition could account for the observed relatively small dilution of ~ 10% in the Tank 43H surface sample. Similar solution compositions measured in the current Tank 43H surface and subsurface samples indicate a minimal stratification within the tank.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Single-Grain Bulk YBa{sub 2}Cu{sub 3}O{sub y} Superconductor Grown in Shorter Duration by IG Process

The top-seeded infiltration growth (IG) process is considered to be an attractive, well-established route compared to melt growth (MG) process due to its successful ability to resolve observed problems in MG process such as pores, shrinkage, and an ununiformed Y{sub 2}BaCuO{sub 5} (Y-211) secondary phase particle dispersion in Y-123 matrix. This is among the first accounts of superconductivity where a large grain YBa{sub 2}Cu{sub 3}O{sub y} (Y-123) was produced by IG process. Further, by utilizing homemade Y-123 and Y-211, we had prepared YBa{sub 2}Cu{sub 3}O{sub y} samples via Y-123 + liquid (1:1) as a liquid source and had further characterized by utilizing the scanning electron microscopy (SEM), superconducting transition temperature (T{sub c}), and critical current density (J{sub c}) at 77 K. Here, we provide temperature dependence of magnetization measurements that indicated a sharp superconducting transition with T{sub c} (onset) around 92 K. In addition, the critical current density was calculated on the basis of Bean’s model and resulted as 30,000 A/cm{sup 2} at 77 K (self-field), H//c-axis. Trapped field experiments had lucidly indicated that single-grain nature with maximum-trapped field of 0.3 T at 77 K and 1 mm above sample surface even samples are produced shorter duration, i.e., 50 h.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Investigation and Applications of In-Source Oxidation in Liquid Sampling-Atmospheric Pressure Afterglow Microplasma Ionization (LS-APAG) Source

A liquid sampling-atmospheric pressure afterglow microplasma ionization (LS-APAG) source is presented for the first time, which is embedded with both electrospray ionization (ESI) and atmospheric pressure afterglow microplasma ionization (APAG) techniques. This ion source is capable of analyzing compounds with diverse molecule weights and polarities. An unseparated mixture sample was detected as a proof-of-concept, giving complementary information (both polarities and non-polarities) with the two ionization modes. It should also be noted that molecular mass can be quickly identified by ESI with clean and simple spectra, while the structure can be directly studied using APAG with in-source oxidation. The ionization/oxidation mechanism and applications of the LS-APAG source have been further explored in the analysis of nonpolar alkanes and unsaturated fatty acids/esters. A unique [M + O – 3H]{sup +} was observed in the case of individual alkanes (C{sub 5}–C{sub 19}) and complex hydrocarbons mixture under optimized conditions. Moreover, branched alkanes generated significant in-source fragments, which could be further applied to the discrimination of isomeric alkanes. The technique also facilitates facile determination of double bond positions in unsaturated fatty acids/esters due to diagnostic fragments (the acid/ester-containing aldehyde and acid oxidation products) generated by on-line ozonolysis in APAG mode. Finally, some examples of in situ APAG analysis by gas sampling and surface sampling were given as well. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Results of Hg Speciation Testing on Tank 38 and 2H Evaporator Overhead Tank (OHT-1) Materials

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The seventh shipment of samples was designated to include two Tank 38 (2H Evaporator System Drop Tank) samples: a surface sample (HTF-38-15-48) and a variable depth sample taken at 265” (HTF-38-15-50). The third sample submitted was from the 2H Evaporator Overhead Tank (OHT) #1. All samples were received by SRNL on May 11, 2015. The OHT-1 was not placed in the SRNL Shielded Cells but was instead placed in a refrigerator in 773-A, B-wing upon receipt and kept at 4°C. The Tank 38 samples were left in their stainless steel dip bottles until they were opened and an aliquot of each diluted 1:10 with Eurofins deionized water on June 1, 2015. Following initial dilution in the Shielded Cells, the diluted Tank 38 samples were immediately moved to refrigeration and kept in the dark until prepared for shipment to Eurofins.

54 ENVIRONMENTAL SCIENCES↗

Results of HG Speciation Testing on Tank 43 and 2H Evaporator Overhead Tank (OHT-2) Materials

The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The eighth shipment of samples was designated to include two Tank 43 (2H Evaporator System Feed Tank) samples: a surface sample (HTF-43-15-52) and a variable depth sample taken at 161” (HTF-43-15-54). The third sample submitted was from the 2H Evaporator Overhead Tank (OHT) #2. All samples were received by SRNL on May 11, 2015. The OHT-2 was not placed in the SRNL Shielded Cells but was instead placed in a refrigerator in 773-A, B-wing upon receipt and kept at 4°C. The Tank 43 samples were left in their stainless steel dip bottles until they were opened and an aliquot of each diluted 1:10 with Eurofins deionized water on June 3, 2015. Following initial dilution in the Shielded Cells, the diluted Tank 43 samples were immediately moved to refrigeration and kept in the dark until prepared for shipment to Eurofins.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

High efficiency environmental sampling with rapidly cured peelable coatings

A rapidly curable liquid gel for collecting an analyte from a sampling surface includes a polymer precursor mixture including a monomer and/or an oligomer; and an additive to enhance extraction of the analyte from the sampling surface. A kit for collecting an analyte from a sampling surface may include the rapidly curable liquid gel and a portable device for rapidly curing the gel. The rapidly curable liquid gel is cured to thereby form a peelable sampling film, and the sampling film is removed from the sampling surface, thereby collecting the analyte. In one embodiment, the rapidly curable liquid gel is UV-curable, the polymer precursor mixture further includes a photoinitiator compound, and the portable device includes a UV light source configured to emit UV light of a wavelength range absorbed by the photoinitiator compound.

Henzl, Vladimir↗

On Boron Diffusion in MgF{sub 2}

The MgF{sub 2} monocrystals were irradiated at room temperature with 390 keV B{sup +} ions up to the fluence of 10{sup 16} cm{sup -2}. The irradiated samples were (isochronally and isothermally) annealed in high vacuum at the temperatures 200 deg. C, 300 deg. C, 400 deg. C, 500 deg. C, 600 deg. C and 700 deg. C for the times ranging from 2-100 hours. After each annealing step, the boron depth distribution was determined using the neutron depth profiling technique. As implanted, the depth distributions of boron exhibited standard Gaussian-like forms, but the evaluated profile parameters, R{sub P} = 960 nm and {delta}R{sub P} = 140 nm, were higher than those calculated using the SRIM code (R{sub P} = 870 nm and {delta}R{sub P} = 115 nm). Annealing at temperatures up to 400 deg. C did not change the depth profiles. Annealing at 600 deg. C, however, led to a one-way gradual transfer of the boron atoms from the site of implantation towards the sample surface, and in this way a bimodal profile was created. The amount of boron atoms, transferred to the sample surface, was an increasing function of the annealing time. After annealing at 700 deg. C for 64 hours the bimodal profile collapsed into a single broad distribution, extending from the sample surface up to the implantation depth. The observed phenomena clearly points out the stability of the as-implanted boron depth profiles at lower annealing temperatures. Thermal annealing above 600 deg. C, however, liberates boron atoms, which then predominantly migrate from the implantation site towards the sample surface, where they are captured on some unspecified surface defects.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Analysis of Tank 30H (HTF-30-18-54, -55), Tank 32H (HTF-32-18-56, -57), and Tank 37H (HTF-37-18-58, -59) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solution s with sodium concentrations ranging from 7.89 M to 15.0 M. The samples from Tank 30H show small differences in the concentrations of the major cations and anions between the surface sample and VDS. The two Tank 32H samples show significant differences in the concentrations of the major anions and cations with the VDS being nearly twice as concentrated as the surface sample. The surface sample and VDS from Tank 37H contain very similar compositions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Summary of Surface Swipe Sampling for Beryllium on Lead Bricks and Shielding

Approximately 25,000 lbs of lead bricks at Site 300 were assessed by the Site 300 Industrial Hygienis tand Health Physicist for potential contamination of beryllium and radiation for reuse. These lead bricks and shielding had been used as shielding material during explosives tests that included beryllium and depleted uranium. Based on surface swipe sampling that was performed between July 26 and October 11, 2010, specifically for beryllium, the use of a spray encapsulant was found to be an effective means to limit removable surface contamination to levels below the DOE release limit for beryllium, which is 0.2 mcg/100 cm{sup 2}. All the surface swipe sampling data for beryllium and a timeline of when the samples were collected (and a brief description) are presented in this report. On December 15, 2010, the lead bricks and shielding were surveyed with an ion chamber and indicated dose rates less than 0.05 mrem per hour on contact. This represents a dose rate consistent with natural background. An additional suevey was performed on February 8, 2011, using a GM survey instrument to estimate total activity on the lead bricks and shielding, confirming safe levels of radioactivity. The vendor is licensed to possess and work with radioactive material.

61 RADIATION PROTECTION AND DOSIMETRY↗

Direct Sampling and Analysis from Solid Phase Extraction Cards using an Automated Liquid Extraction Surface Analysis Nanoelectrospray Mass Spectrometry System

Direct liquid extraction based surface sampling, a technique previously demonstrated with continuous flow and autonomous pipette liquid microjunction surface sampling probes, has recently been implemented as the Liquid Extraction Surface Analysis (LESA) mode on the commercially available Advion NanoMate chip-based infusion nanoelectrospray ionization system. In the present paper, the LESA mode was applied to the analysis of 96-well format custom solid phase extraction (SPE) cards, with each well consisting of either a 1 or 2 mm diameter monolithic hydrophobic stationary phase. These substrate wells were conditioned, loaded with either single or multi-component aqueous mixtures, and read out using the LESA mode of a TriVersa NanoMate or a Nanomate 100 coupled to an ABI/Sciex 4000QTRAPTM hybrid triple quadrupole/linear ion trap mass spectrometer and a Thermo LTQ XL linear ion trap mass spectrometer. Extraction conditions, including extraction/nanoESI solvent composition, volume, and dwell times, were optimized in the analysis of targeted compounds. Limit of detection and quantitation as well as analysis reproducibility figures of merit were measured. Calibration data was obtained for propranolol using a deuterated internal standard which demonstrated linearity and reproducibility. A 10x increase in signal and cleanup of micromolar Angiotensin II from a concentrated salt solution was demonstrated. Additionally, a multicomponent herbicide mixture at ppb concentration levels was analyzed using MS3 spectra for compound identification in the presence of isobaric interferences.

Direct liquid extraction↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37-19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Tank 30H (HTF-30-19-33, -34), Tank 32H (HTF-32-19-35, -36), and Tank 37H (HTF-37- 19-53, -54) Samples for Support of the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator

SRNL analyzed samples from Tank 30H, Tank 32H, and Tank 37H to support the Evaporator Feed Qualification and Corrosion Control Programs for the 3H-Evaporator system. The six samples from Tanks 30H, 32H, and 37H all contain highly concentrated salt solutions with sodium concentrations ranging from 13.8 M to 16.9 M. Hydroxide is the dominant anion in all of the samples followed by nitrate and nitrite. The preponderance of the analytical determinations (density, anions, cations) on all three tanks show slightly higher concentrations of solute in the sub-surface sample than in the surface sample, indicating some stratification within the tanks. With the exception of the Tank 30H VDS, all of the samples are somewhat more concentrated compared with the compositions of the previous samples. The sum of the major cations versus the sum of the major anions show a difference of <5% for all of the samples indicating good data quality for the non-radioactive analytes in the table. The silicon concentrations measured in the VDS and surface samples from Tank 30H, Tank 32H, and Tank 37H were all below detection.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Mechanisms of dissolution from gibbsite step edges elucidated by ab initio molecular dynamics with enhanced sampling

Surface reactions underpin our collective understanding of mineral dissolution. This impacts a range of predictive geochemical models (for weathering, the fate and transport of metals) as well as industrial utilization of minerals. Yet atomistic details are rarely known due to the complex mineral/fluid interfacial environment. There is significant need to understand the mechanistic details of dissolution reactions and how they depend on surface morphology and solution conditions. This work utilizes surface pit models in conjunction with changes to solution composition that mimic pH to explore surface detachment of aluminate from gibbsite, which is a primary source of Al in soils and within the industrial processing of aluminum. Ab initio molecular dynamics simulations with enhanced sampling has been used to explore the detailed process of the detachment, the results of which indicate two potential pathways that are differentiated based upon the extent of water hydration. Here, the heights of the energy barriers depend upon the local morphology which influence the number of bridges (quasi-)simultaneously broken (1 or 2) or the Al-O coordination of the neighboring aluminum atoms (5 or 6) at the armchair edge. pH effects are significant, with a nearly 50% reduction in barrier height under alkaline conditions that are relevant to geothermal fluids and Al extraction from minerals.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗