Search NASA⌕ Search

SEARCH · Search NASA

Results for “Surface sampling probe”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Strong-coupling quantum dot microscope

Here, we report the development and fabrication of a novel cryogenic instrument, a scanning quantum dot microscope (SQDM), capable of positioning a quantum dot to within tunneling range of a sample surface. The microscope is strong-coupling in the sense that electron wavefunctions in the quantum dot can directly overlap with electron wavefunctions in the sample, in contrast to probes based on electric-field coupling. The SQDM consists of a sharp glass probe with two asymmetric electrodes leading to an aluminum quantum dot at the apex. One electrode is capacitively coupled to the quantum dot, while the other lead is connected to the dot via a tunneling junction. A charge sensing circuit constructed from a high-electron-mobility transistor is attached to the capacitance lead to measure the charge state of the dot. The last key feature of the design is a tilted-apex geometry. This design feature, in conjunction with the capacitive sensing scheme, results in a robust quantum-dot probe capable of operating within angstrom distances of the sample surface while protecting the single tunnel junction responsible for electron transport onto the quantum dot. We demonstrate that our instrument can detect single-electron tunneling events and can also be operated as a standard scanning tunneling microscope capable of nanometer-scale resolution of the surface topography.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Surface studies on aluminized and thermally oxidized superalloy 690 substrates interacted with simulated nuclear waste and sodium borosilicate melt

Aluminized and thermally oxidized Ni-Cr-Fe based superalloy 690 substrates with Al{sub 2}O{sub 3} layer on top have been exposed in nitrate based environment (simulated high level nuclear liquid waste) at 373 K for 216 hours and sodium borosilicate melt at 1248 K for 192 hours. The surfaces of exposed samples have been characterized by using Electron probe micro-analyzer (EPMA). Elemental X-ray mapping on coated specimen that exposed in simulated nuclear waste solution revealed that the surface is enriched with Ni, Cr and Al. X-ray mapping on surface of the specimen that interacted with sodium borosilicate melt indicated that the surface is composed of Al, Fe, Ni and Cr.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Observation of skyrmion bubbles in multilayer [Pt/Co/Cu] n using spin-polarized STM

Magnetic multilayers are a promising platform for storage and logic devices based on skyrmion spin textures, due to the large materials phase space for tuning properties. Epitaxial superlattice structures of [Pt/Co/Cu]n thin films were grown by molecular beam epitaxy at room temperature. Spin-polarized scanning tunneling microscopy (SP-STM) of these samples was used to probe the connection between surface structure and skyrmion morphology with nanoscale spatial resolution. Irregular-shaped skyrmion bubbles were observed, with effective diameters from 20 to 200 nm that are much larger than the nanoscale grain structure of the surface topography. Nucleation, annihilation, and motion of skyrmion bubbles could be driven using the stray field of the ferromagnetic tip in repeated imaging, and spin-polarized current/voltage pulses. Furthermore, our detailed comparison of STM topography and differential conductance images shows that there are no surface defects or inhomogeneities at length scales that could account for the range in skyrmion bubble size or shape observed in the measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of secondary electron emission on the plasma sheath

In this experiment, plasma sheath potential profiles are measured over boron nitride walls in argon plasma and the effect of secondary electron emission is observed. Results are compared to a kinetic model. Plasmas are generated with a number density of 3 × 10{sup 12} m{sup −3} at a pressure of 10{sup −4} Torr-Ar, with a 1%–16% fraction of energetic primary electrons. The sheath potential profile at the surface of each sample is measured with emissive probes. The electron number densities and temperatures are measured in the bulk plasma with a planar Langmuir probe. The plasma is non-Maxwellian, with isotropic and directed energetic electron populations from 50 to 200 eV and hot and cold Maxwellian populations from 3.6 to 6.4 eV and 0.3 to 1.3 eV, respectively. Plasma Debye lengths range from 4 to 7 mm and the ion-neutral mean free path is 0.8 m. Sheath thicknesses range from 20 to 50 mm, with the smaller thickness occurring near the critical secondary electron emission yield of the wall material. Measured floating potentials are within 16% of model predictions. Measured sheath potential profiles agree with model predictions within 5 V (∼1 T{sub e}), and in four out of six cases deviate less than the measurement uncertainty of 1 V.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Structured illumination with thermal imaging (SI-TI): A dynamically reconfigurable metrology for parallelized thermal transport characterization

The recent push for the “materials by design” paradigm requires synergistic integration of scalable computation, synthesis, and characterization. Among these, techniques for efficient measurement of thermal transport can be a bottleneck limiting the experimental database size, especially for diverse materials with a range of roughness, porosity, and anisotropy. Traditional contact thermal measurements have challenges with throughput and the lack of spatially resolvable property mapping, while non-contact pump-probe laser methods generally need mirror smooth sample surfaces and also require serial raster scanning to achieve property mapping. Here, we present structured illumination with thermal imaging (SI-TI), a new thermal characterization tool based on parallelized all-optical heating and thermometry. Experiments on representative dense and porous bulk materials as well as a 3D printed thermoelectric thick film (~50 μm) demonstrate that SI-TI (1) enables paralleled measurement of multiple regions and samples without raster scanning; (2) can dynamically adjust the heating pattern purely in software, to optimize the measurement sensitivity in different directions for anisotropic materials; and (3) can tolerate rough (~3 μm) and scratched sample surfaces. Here, this work highlights a new avenue in adaptivity and throughput for thermal characterization of diverse materials.

42 ENGINEERING↗

Addressing the challenges of plasma-surface interactions in NSTX-U*

The importance of conditioning plasma-facing components (PFCs) has long been recognized as a critical element in obtaining high-performance plasmas in magnetic confinement devices. Lithium coatings, for example, have been used for decades for conditioning PFCs. Since the initial studies on the Tokamak Fusion Test Reactor, experiments on devices with different aspect ratios and magnetic geometries like the National Spherical Torus Experiment (NSTX) continue to show the relationship between lithium PFCs and good confinement and stability. While such results are promising, their empirical nature do not reflect the detailed relationship between PFCs and the dynamic conditions that occur in the tokamak environment. A first step developing an understanding such complexity will be taken in the upgrade to NSTX (NSTX-U) that is nearing completion. New measurement capabilities include the Materials Analysis and Particle Probe (MAPP) for in situ surface analysis of samples exposed to tokamak plasmas. The OEDGE suite of codes, for example, will provide a new way to model the underlying mechanisms for such material migration in NSTX-U. This will lead to a better understanding of how plasma-facing surfaces evolve during a shot, and how the composition of the plasma facing surface influences the discharge performance we observe. This paper will provide an overview of these capabilities, and highlight their importance for NSTX-U plans to transition from carbon to high-Z PFCs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A strategy to eliminate selenium oxide islands formed on the ZnSe/GaAs epilayer

Atomically clean and smooth surfaces are essential for semiconductor device fabrication and epitaxial regrowth. In this regard, spontaneously formed oxide islands or clusters on the surfaces of II-VI semiconductor exposures to air can disrupt interface formation. Using ZnSe/GaAs heterostructures grown by molecular beam epitaxy (MBE), we investigated the effect of surface treatments in eliminating oxide islands. The samples were probed with atomic force microscopy, low-temperature photoluminescence, and scanning electron microscopy. Here, it was found that ultra-high vacuum (UHV) annealing at 200°C, regardless of annealing duration, largely removed the islands while leaving the crystallinity of the ZnSe and GaAs epilayers unaffected. UHV annealing at higher temperatures of 300°C completely removed the islands, but the optical properties of ZnSe and/or GaAs epilayers deteriorated depending on the annealing duration. Our observations provide guidance to set thermal annealing strategies for removing oxide islands from the surfaces of II-VI/III-V semiconductor heterostructures depending on the desired properties.

36 MATERIALS SCIENCE↗

Nanomechanical sampling of material for nanoscale mass spectrometry chemical analysis

The ability to spatially resolve the chemical distribution of compounds on a surface is important in many applications ranging from biological to material science. To this extent, we have recently introduced a hybrid atomic force microscopy (AFM)-mass spectrometry (MS) system for direct thermal desorption and pyrolysis of material with nanoscale chemical resolution. However, spatially resolved direct surface heating using local thermal desorption becomes challenging on material surfaces with low melting points, because the material will undergo a melting phase transition due to heat dissipation prior to onset of thermal desorption. Therefore, here we developed an approach using mechanical sampling and collection of surface materials on an AFM cantilever probe tip for real-time analysis directly from the AFM tip. This approach allows for material to be concentrated directly onto the probe for subsequent MS analysis. We evaluate the performance metrics of the technique and demonstrate localized MS sampling from a candelilla wax matrix containing UV stabilizers avobenzone and oxinoxate from areas down to 250 nm × 250 nm. Overall, this approach removes heat dissipation into the bulk material allowing for a faster desorption and concentration of the gas phase analyte from a single heating pulse enabling higher signal levels from a given amount of material in a single sampling spot.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Scanning thermal microscopy based on a quartz tuning fork and a micro-thermocouple in active mode (2ω method)

A novel probe for scanning thermal microscope using a micro-thermocouple probe placed on a Quartz Tuning Fork (QTF) is presented. Instead of using an external deflection with a cantilever beam for contact detection, an original combination of piezoelectric resonator and thermal probe is employed. Due to a non-contact photothermal excitation principle, the high quality factor of the QTF allows the probe-to-surface contact detection. Topographic and thermal scanning images obtained on a specific sample points out the interest of our system as an alternative to cantilevered resistive probe systems which are the most spread.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modulated microwave microscopy and probes used therewith

A microwave microscope including a probe tip electrode vertically positionable over a sample and projecting downwardly from the end of a cantilever. A transmission line connecting the tip electrode to the electronic control system extends along the cantilever and is separated from a ground plane at the bottom of the cantilever by a dielectric layer. The probe tip may be vertically tapped near or at the sample surface at a low frequency and the microwave signal reflected from the tip/sample interaction is demodulated at the low frequency. Alternatively, a low-frequency electrical signal is also a non-linear electrical element associated with the probe tip to non-linearly interact with the applied microwave signal and the reflected non-linear microwave signal is detected at the low frequency. The non-linear element may be semiconductor junction formed near the apex of the probe tip or be an FET formed at the base of a semiconducting tip.

47 OTHER INSTRUMENTATION↗

In Situ X-Ray Probing Reveals Fingerprints of Surface Platinum Oxide

In situ x-ray absorption spectroscopy (XAS) at the Pt L{sub 3} edge is a useful probe for Pt-O interactions at polymer electrolyte membrane fuel cell (PEMFC) cathodes. We show that XAS using the high energy resolution fluorescence detection (HERFD) mode, applied to a well-defined monolayer Pt/Rh(111) sample where the bulk penetrating hard x-rays probe only surface Pt atoms, provides a unique sensitivity to structure and chemical bonding at the Pt-electrolyte interface. Ab initio multiple-scattering calculations using the FEFF8 code and complementary extended x-ray absorption fine structure (EXAFS) results indicate that the commonly observed large increase of the white-line at high electrochemical potentials on PEMFC cathodes originates from platinum oxide formation, whereas previously proposed chemisorbed oxygen-containing species merely give rise to subtle spectral changes.

30 DIRECT ENERGY CONVERSION↗

Accurate formula for dissipative interaction in frequency modulation atomic force microscopy

Much interest has recently focused on the viscosity of nano-confined liquids. Frequency modulation atomic force microscopy (FM-AFM) is a powerful technique that can detect variations in the conservative and dissipative forces between a nanometer-scale tip and a sample surface. We now present an accurate formula to convert the dissipation power of the cantilever measured during the experiment to damping of the tip-sample system. We demonstrated the conversion of the dissipation power versus tip-sample separation curve measured using a colloidal probe cantilever on a mica surface in water to the damping curve, which showed a good agreement with the theoretical curve. Moreover, we obtained the damping curve from the dissipation power curve measured on the hydration layers on the mica surface using a nanometer-scale tip, demonstrating that the formula allows us to quantitatively measure the viscosity of a nano-confined liquid using FM-AFM.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A new set-up for in-situ probing of radiation effects in materials and electronic devices

The micro-probe facility installed at the Van de Graff accelerator at CTN/IST permits simultaneous measurements of Rutherford Backscattering Spectrometry (RBS), Particle Induced X-ray Emission (PIXE) and Iono-Luminescence (IL). Here we present a recent up-grade of the measurement chamber allowing improved optical sensitivity in IL measurements and opening the possibility to perform simultaneously electrical measurements. Combinations of all these characterization techniques make this setup a powerful tool to characterize and modify different materials with spatial resolution. In particular, it can be used to study radiation effects in different materials and electronic devices in-situ. IL is a luminescence technique that uses the ion beam as the excitation source. Compared with other luminescence techniques with spatial resolution like Cathodoluminescence, this technique has the advantage to probe deeper regions of the sample, several microns below the surface. The same ion beam used to produce luminescence, can create a high density of defects, in a controllable way and the new set-up allows monitoring optical and electrical properties in realtime. In this work we combine IL with I-V curve measurements to assess the response of Ga{sub 2}O{sub 3} and GaN to proton irradiation. Ga{sub 2}O{sub 3} and GaN are emerging materials for applications in high power electronics and are considered for radiation resistant electronics. We will present a systematic study of the changes in IL and conductivity in Ga{sub 2}O{sub 3} and GaN samples with the energy of the ion beam and with the time of exposure. In particular, it was observed that during the irradiation some luminescence bands related with intrinsic point defects decrease while other new bands appear. Simulations using the SRIM code were used to determine the depth profiles of ionization and displacement events, helping to correlate the optical and electrical response of the materials with certain radiation effects. These studies show the potentialities of measuring simultaneously IL and electrical conductivity and how these two characterization techniques can work as a sensitive tool to detect and quantify radiation effects. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface characterization of InP trenches embedded in oxide using scanning probe microscopy

Metrology for structural and electrical analyses at device level has been identified as one of the major challenges to be resolved for the sub-14 nm technology nodes. In these advanced nodes, new high mobility semiconductors, such as III–V compounds, are grown in narrow trenches on a Si substrate. Probing the nature of the defects, the defect density, and the role of processing steps on the surface of such structures are prime metrology requirements. In order to enable defect analysis on a (III–V) surface, a proper sample preparation for oxide removal is of primary importance. In this work, the effectiveness of different chemical cleanings and thermal annealing procedures is investigated on both blanket InP and oxide embedded InP trenches by means of scanning probe microscopy techniques. It is found that the most effective approach is a combination of an HCl-based chemical cleaning combined with a low-temperature thermal annealing leading to an oxide free surface with atomically flat areas. Scanning tunneling microscopy (STM) has been the preferred method for such investigations on blanket films due to its intrinsic sub-nm spatial resolution. However, its application on oxide embedded structures is non-trivial. To perform STM on the trenches of interest (generally <20 nm wide), we propose a combination of non-contact atomic force microscopy and STM using the same conductive atomic force microscopy tip Our results prove that with these procedures, it is possible to perform STM in narrow InP trenches showing stacking faults and surface reconstruction. Significant differences in terms of roughness and terrace formation are also observed between the blanket and the oxide embedded InP.

36 MATERIALS SCIENCE↗

Note: A stand on the basis of atomic force microscope to study substrates for imaging optics

A description of a stand based on atomic force microscopy (AFM) for roughness measurements of large optical components with arbitrary surfaces is given. The sample under study is mounted on a uniaxial goniometer which allows the sample to be tilted in the range of ±30°. The inclination enables the local normal along the axis of the probe to be established at any point of the surface under study. A comparison of the results of the measurement of noise and roughness of a flat quartz sample, in the range of spatial frequencies 0.025–70 μm{sup −1}, obtained from “standard” AFM and developed versions is given. Within the experimental error, the measurement results were equivalent. Examples of applications of the stand for the study of substrates for X-ray optics are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accessing the Intrinsic Spin Transport in a Topological Insulator by Controlling the Crossover of Bulk-to-Surface Conductance

Here we report a method to control contributions of bulk and surface states in the topological insulator Bi 2 Te 2 Se that allows accessing the spin-polarized transport endowed by topological surface states. An intrinsic surface dominant transport is established when cooling the sample to low temperature or reducing the conduction channel length, both achieved in situ in the transport measurements with a four-probe scanning tunneling microscope without the need of further tailoring the sample. The topological surface states show characteristic transport behaviors with mobility about an order of magnitude higher than reported before, and a spin polarization approaching the theoretically predicted value. Our result demonstrates accessibility to the intrinsic high mobility spin transport of topological surface states, which paves a way to realizing topological spintronic devices.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of Young's modulus variation with layer pair and interplanar spacing in gold–nickel nanolaminates using nanoindentation and the tapping mode

The features of grain size and interface separation strengthen the mechanical behavior of metallic nanolaminates. In addition, the presence of interlayer lattice strains can lead to a superlattice structure within the nanolaminate. The superlattice affects intrinsic properties of technological interest including electronic, magnetic, and elastic. The complex elastic and plastic behaviors of gold–nickel nanolaminate superlattice coatings as studied using nanoindentation are revisited with the tapping mode of a force microscope. Young's modulus is determined with nanoindentation during the initial elastic unloading after plastic deformation at depths up to one-fifth the coating thickness. The tapping mode provides a measurement during the initial elastic deformation at depths of only a few nanometers. The tapping mode utilizes the shift in the resonant frequency of the probe-cantilever system as contact is made with the sample surface. Both of these nanoprobe test methods produce results for measurements conducted with loading normal to the surface plane. A softening in the Young's modulus of gold–nickel nanolaminate coatings occurs for samples with layer pair spacing between 1 and 9 nm. The magnitude of softening corresponds with a progressive increase in the tensile state as measured with the change of interplanar spacing along the growth direction.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

dropletProbe Premium v1.201

Selects locations of interest for liquid microjunction surface sampling coupled to a subsequent analysis is done in a user friendly way. That information is then transferred to instrument control softwares. In addition, readout of a laser sensor allows for robust probe-to-surface distance measurement. Furthermore, pictures taken by the software from a camera provides feedback to judge on successful microjunction sampling.

Kertesz, Vilmos↗