Energetic Particles Investigation (EPI)

The EPI instrument operates during the pre-entry phase of the Galileo Probe. The main objective is the study of the energetic particle population in the inner Jovian magnetosphere and in the upper atmosphere. This will be achieved through omnidirectional measurements of electrons, protons, alpha-particles and heavy ions (Z greater than 2) and recording intensity profiles with a spatial resolution of about 0.02 Jupiter radii. Sectored data will also be obtained for electrons, protons, and alpha-particles to determine directional anisotropies and particle pitch angle distributions. The detector assembly is a two-element telescope using totally depleted circular silicon surface-barrier detectors surrounded by cylindrical tungsten shielding. The lower energy threshold of the particle species investigated during the Probe's pre-entry phase is determined by the material thickness of the Probe's rear heat shield which is required for heat protection of the scientific payload during entry into the Jovian atmosphere. The EPI instrument is combined with the Lightning and Radio Emission Detector and both instruments share one interface of the Probe's power, command, and data unit.

Fischer, H. M.↗

Orbiter global positioning system design and Ku-band problem investigations, exhibit B, revision 1

The shuttle Ku-band Costas loop lock detector output signal appears to vary about the lock detection threshold (the lock detect flag is on and off) shortly after the carrier acquisition starts. Real time computer simulation was performed to obtain the signal output from the low pass filter of the lock detector. Based on this simulation, it appears that the oscillation of in-lock and out-lock is related to tracking process and is not caused by the sweep acquisition algorithm.

Lindsey, W. C.↗

Neutron fluences and dose equivalents measured with passive detectors on LDEF

Neutron fluences were measured on LDEF in the low energy (< 1 MeV) and high energy (> 1 MeV) ranges. The low energy detectors used the 6Li(n,alpha)T reaction with Gd foil absorbers to separate thermal (< 0.2 eV) and resonance (0.2 eV-1 MeV) neutron response. High energy detectors contained sets of fission foils (181Ta, 209Bi, 232Th, 238U) with different neutron energy thresholds. The measured neutron fluences together with predicted spectral shapes were used to estimate neutron dose equivalents. The detectors were located in the A0015 and P0006 experiments at the west and Earth sides of LDEF under shielding varying from 1 to 19 g/cm2. Dose equivalent rates varied from 0.8 to 3.3 microSv/d for the low energy neutrons and from 160 to 390 microSv/d for the high energy neutrons. This compares with TLD measured absorbed dose rates in the range of 1000-3000 microGy/d near these locations and demonstrates that high energy neutrons contribute a significant fraction of the total dose equivalent in LEO. Comparisons between measurements and calculations were made for high energy neutrons based on fission fragment tracks generated by fission foils at different shielding depths. A simple 1-D slab geometry was used in the calculations. Agreement between measurements and calculations depended on both shielding depth and threshold energy of the fission foils. Differences increased as both shielding and threshold energy increased. The modeled proton/neutron spectra appeared deficient at high energies. A 3-D model of the experiments is needed to help resolve the differences.

LDEF Project↗

Threshold detection in pulsed laser ranging

Suzaki and Tachibana (1972, 1973) have developed a method for detecting the arrival time of the return pulse in pulsed laser ranging based on the identification of the time at which the preset threshold level is exceeded by the output of the optical detector. The received optical pulse is considered to be made up of cells of width equal to the resolution time of the receiver and an equation is derived for P sub j, the probability that the threshold is first exceeded in the j-th cell. Using the density P sub j, expressions are obtained for the mean position of the cell at which threshold occurs and for the standard deviation (rms error) in the detection cell. The present paper maintains that, since the number j is purely an artifice for identifying the cells, its mean and standard deviation are inadequate for characterizing the detection cell and detection errors. It is proposed that if the detection cell is defined as the cell at which P sub j attains a maximum, then the above-cited ambiguity would be eliminated.

Iyer, R. S.↗

Average features of the muon component of EAS or = 10(17) eV

Three 10 sq m liquid scintillators were situated at approximately 0 m, 150 m and 250 m from the center of the Haverah Park array. The detectors were shielded by lead/barytes giving muon detection thresholds of 317 MeV, 431 MeV and 488 MeV respectively. During part of the operational period the 431 MeV threshold was lowered to 313 MeV for comparison purposes. For risetime measurement fast phototubes were used and the 10% to 70% amplitude time interval was parameterized by T sub 70. A muon lateral density distribution of the form rho mu (R theta) = krho(500)0.94 1/R(1 + R/490)-eta has been fitted to the data for 120 m R 600 m and 0.27 (500) 2.55. The shower size parameter (500) is the water Cerenkov response at 500 m from the core of the extensive air showers (EAS) and is relatable to the primary energy. The results show general consistency.

Blake, P. R.↗

A Broadband X-Ray Imaging Spectroscopy with High-Angular Resolution: the FORCE Mission

We are proposing FORCE (Focusing On Relativistic universe and Cosmic Evolution) as a future Japan-lead X-ray observatory to be launched in the mid 2020s. Hitomi (ASTRO-H) possesses a suite of sensitive instruments enabling the highest energy-resolution spectroscopy in soft X-ray band, a broadband X-ray imaging spectroscopy in soft and hard X-ray bands, and further high energy coverage up to soft gamma-ray band. FORCE is the direct successor to the broadband X-ray imaging spectroscopy aspect of Hitomi (ASTRO-H) with significantly higher angular resolution. The current design of FORCE defines energy band pass of 1-80 keV with angular resolution of <15" in half-power diameter, achieving a 10 times higher sensitivity above 10 keV compared to any previous missions with simultaneous soft X-ray coverage. Our primary scientific objective is to trace the cosmic formation history by searching for "missing black holes" in various mass-scales: "buried supermassive black holes (SMBHs)" (> 10(exp 4) Stellar Mass) residing in the center of galaxies in a cosmological distance, "intermediate-mass black holes" (10(exp 2)-(10(exp 4) Stellar Mass) acting as the possible seeds from which SMBHs grow, and "orphan stellar-mass black holes" (< 10(exp 2) Stellar Mass) without companion in our Galaxy. In addition to these missing BHs, hunting for the nature of relativistic particles at various astrophysical shocks is also in our scope, utilizing the broadband X-ray coverage with high angular-resolution. FORCE are going to open a new era in these fields. The satellite is proposed to be launched with the Epsilon vehicle that is a Japanese current solid-fuel rocket. FORCE carries three identical pairs of Super-mirror and wide-band X-ray detector. The focal length is currently planned to be 10 m. The silicon mirror with multi-layer coating is our primary choice to achieve lightweight, good angular optics. The detector is a descendant of hard X-ray imager onboard Hitomi (ASTRO-H) replacing its silicon strip detector with SOI-CMOS silicon pixel detector, allowing an extension of the low energy threshold down to 1 keV or even less.

Hard X-ray↗

Fixed lag smoothers for carrier phase and frequency tracking

The application of fixed lag smoothing algorithms are presented for the problem of estimation of the phase and frequency of a sinusoidal carrier received in the presence of process noise and additive observation noise. A suboptimal structure consists of a phase-locked loop (PLL) followed by a post loop correction to the phase and frequency estimates. When the PLL is operating under a high signal-to-noise ratio, the phase detector is approximately linear, and the smoother equations then correspond to the optimal linear equations for an equivalent linear signal model. The performance of such a smoother can be predicted by the linear filtering theory. However, if the PLL is operating near the threshold region of the signal to noise ratio, the phase detector cannot be assumed to be linear. Then the actual performance of the smoother can significantly differ from that predicted by linear filtering theory. Both the theoretical and simulated performance of such smoothers derived on the basis of various models for the phase of frequency processes are presented.

Kumar, R.↗

Optimum filters and smoothers design for carrier phase and frequency tracking

The report presents the application of fixed lag smoothing algorithms to the problem of estimation of the phase and frequency of a sinusoidal carrier received in the presence of process noise and additive observation noise. A suboptimal structure consists of a phase-locked loop (PLL) followed by post-loop correction to the phase and frequency estimates. When the PLL is operating under high signal-to-noise ratio, the phase detector is approximately linear, and the smoother equations then correspond to the optimal linear equations for an equivalent linear signal model. The performance of such a smoother can be predicted by linear filtering theory. However, if the PLL is operating near the threshold region of the signal-to-noise ratio, the phase detector cannot be assumed to be linear. Then the actual performance of the smoother can significantly differ from that predicted by linear theory. In this report we present both the theoretical and simulated performance of such smoothers derived on the basis of various models for the phase and frequency processes.

Kumar, Rajendra↗

Test of the Equivalence Principle in an Einstein Elevator

This Annual Report illustrates the work carried out during the last grant-year activity on the Test of the Equivalence Principle in an Einstein Elevator. The activity focused on the following main topics: (1) analysis and conceptual design of a detector configuration suitable for the flight tests; (2) development of techniques for extracting a small signal from data strings with colored and white noise; (3) design of the mechanism that spins and releases the instrument package inside the cryostat; and (4) experimental activity carried out by our non-US partners (a summary is shown in this report). The analysis and conceptual design of the flight-detector (point 1) was focused on studying the response of the differential accelerometer during free fall, in the presence of errors and precession dynamics, for various detector's configurations. The goal was to devise a detector configuration in which an Equivalence Principle violation (EPV) signal at the sensitivity threshold level can be successfully measured and resolved out of a much stronger dynamics-related noise and gravity gradient. A detailed analysis and comprehensive simulation effort led us to a detector's design that can accomplish that goal successfully.

Shapiro, Irwin I.↗

GaAs-based optoelectronic neurons

An integrated, optoelectronic, variable thresholding neuron implemented monolithically in GaAs integrated circuit and exhibiting high differential optical gain and low power consumption is presented. Two alternative embodiments each comprise an LED monolithically integrated with a detector and two transistors. One of the transistors is responsive to a bias voltage applied to its gate for varying the threshold of the neuron. One embodiment is implemented as an LED monolithically integrated with a double heterojunction bipolar phototransistor (detector) and two metal semiconductor field effect transistors (MESFET's) on a single GaAs substrate and another embodiment is implemented as an LED monolithically integrated with three MESFET's (one of which is an optical FET detector) on a single GaAs substrate. The first noted embodiment exhibits a differential optical gain of 6 and an optical switching energy of 10 pJ. The second embodiment has a differential optical gain of 80 and an optical switching energy of 38 pJ. Power consumption is 2.4 and 1.8 mW, respectively. Input 'light' power needed to turn on the LED is 2 micro-W and 54 nW, respectively. In both embodiments the detector is in series with a biasing MESFET and saturates the other MESFET upon detecting light above a threshold level. The saturated MESFET turns on the LED. Voltage applied to the biasing MESFET gate controls the threshold.

Lin, Steven H.↗

Bit-synchronizer lock detector

Circuit measures phase error that exists in phase-locked loop between clock signal recorded in data on magnetic tape and reconstructed clock signal. Circuit presents error as digital word that can be compared with predetermined threshold to indicate lock status. With simple alterations, circuit can also be used as phase detector.

Huey, D. C.↗

Real-time processor for staring receivers

The design, fabrication, and testing of a state-of-the-art, high-throughput on-focal plane IR-image signal processor is described. The processing functions performed are frame differencing and thresholding. The final focal plane array will consist of a 128 x 128-pixel platinum-silicide detector bump-mounted to an on-chip CCD multiplexer. The processor is in a 128-channel parallel-pipeline format. Each channel consists of a pixel regenerator (charge differencer), 128-pixel frame store CCD memory, pixel differencer, second pixel regenerator, thresholder (analog comparator), and digital latch. Four parallel analog outputs and four parallel digital outputs are included. The digital outputs provide a bit map of the image. All analog clock signals (128 KHz, 256 KHz, and 5 MHz) are generated by on-chip TTL-input clock drivers. TTL clock driver inputs are generated off-chip. The technology is low-temperature surface and buried channel CCD/CMOS/indium bump. The design goal was 8-bit resolution at 77 K and 1000 frames/s. Applications include point- or extended-target motion detection with thresholding. Design trade-offs and enhancements (such as on-chip detector gain compensation and a simple window processor) are discussed.

Hanzal, Brian↗

Evaluation of liquid water measuring instruments in cold clouds sampled during FIRE

Airborne liquid water content (LWC) measurements were conducted with an icing detector and a forward-scattering spectrometer probe during 10 flights into cold clouds, as part of the First ISCCP Research Experiment (FIRE). The LWC measurements thus obtained compare favorably with those from the hot-wire probes in the range where LWC is above the detection limits of the latter; the hot-wire probes have detection thresholds about one order of magnitude higher than is possible with the icing detector and spectrometer probe. FIRE experiment data indicate that LWC should be taken into consideration in cloud studies at temperatures down to at least 35 C.

Heymsfield, Andrew J.↗

The solid state detector technology for picosecond laser ranging

We developed an all solid state laser ranging detector technology, which makes the goal of millimeter accuracy achievable. Our design and construction philosophy is to combine the techniques of single photon ranging, ultrashort laser pulses, and fast fixed threshold discrimination while avoiding any analog signal processing within the laser ranging chain. The all solid state laser ranging detector package consists of the START detector and the STOP solid state photon counting module. Both the detectors are working in an optically triggered avalanche switching regime. The optical signal is triggering an avalanche current buildup which results in the generation of a uniform, fast risetime output pulse.

Prochazka, Ivan↗

Pulse amplitude discriminator threshold calibration

Closed-loop digital circuit, insensitive to drift with age, monitors input signals in particle detector. Basic elements of calibrator are clock circuit, weighting circuit, integrator, and chopper.

Peletier, D. P.↗

Comparison of the Gamma-Ray Burst Sensitivity of Different Detectors

Gamma-ray burst detectors are sensitive at different energies, complicating the comparison of the burst populations that they detect. The instrument teams often report their detector sensitivities in their instruments' energy band. I propose that sensitivities be reported its the threshold peak photon flux FT over the 1-1000 keV energy band for a specific spectral shape. The primary spectral parameter is E(sub p), the energy of the maximum E(sup 2)N(sub E) proportional to upsilon f(sub upsilon). Thus F(sub T) vs. E(sub p). E(sub p) is a useful description of a detector's sensitivity. I find that Swift will be marginally more sensitive than BATSE for E(sub p) greater than 100 keV, but significantly more sensitive for E(sub p) less than 100 keV. Because of its small field-of-view and low energy sensitivity, the FREGATE on HETE-2 is surprisingly sensitive. Both the WFC on BeppoSAX and the WXM on HETE-2 are/were sensitive for low E(sub p). As expected, the GBM on GLAST will be less sensitive than BATSE, while EXIST will be significantly more sensitive than Swift. The BeppoSAX GRBM was less sensitive that the WFC, particularly at low E(sub p).

Band, David L.↗

Evaluation testing of a portable vapor detector for Part-Per-Billion (PPB) level UDMH and N2H4

Trace level detection of hydrazine (N2H4), monomethyl hydrazine (MMH) and unsymmetrical dimethylhydrazine (UDMH) has been receiving increased attention over the past several years. In May 1995 the American Conference of Government Industrial Hygienists (ACGIH) lowered their acceptable threshold limit value (TLV) from 100 parts-per-billion (ppb) to 10 ppb. Several types of ppb-level detectors are being developed by the United States Air Force (USAF) Space and Missile Systems Center (SMSC). A breadboard version of a portable, lightweight hydrazine detection sensor was developed and produced by Giner Corp. for the USAF. This sensor was designed for ppb level UDMH and N2H4 vapor detection in near real-time. This instrument employs electrochemical sensing, utilizing a three electrode cell with an anion-exchange polymer electrolyte membrane as the only electrolyte in the system. The sensing, counter and reference electrodes are bonded to the membrane forming a single component. The only liquid required to maintain the sensor is deionized water which hydrates the membrane. At the request of the USAF SMSC, independent testing and evaluation of the breadboard instrument was performed at NASA's Toxic Vapor Detection Laboratory (TVDL) for response to ppb-level N2H4 and UDMH and MMH. The TVDL, located at Kennedy Space Center (KSC) has the unique ability to generate calibrated sample vapor streams of N2H4, UDMH, and MMH over a range from less than 10 ppb to thousands of parts per million (ppm) with full environmental control of relative humidity (0-90%) and temperature (0-50 C). The TVDL routinely performs these types of tests. Referenced sensors were subjected to extensive testing, including precision, linearity, response/recovery times, zero and span drift, humidity and temperature effects as well as ammonia interference. Results of these tests and general operation characteristics are reported.

Curran, Dan↗