Search NASA⌕ Search

SEARCH · Search NASA

Results for “Terahertz techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

K Elliott Cramer↗

An Overview of Research in Nondestructive Evaluation at the National Aeronautics and Space Administration’s Langley Research Center

The primary focus of the nondestructive evaluation (NDE) effort at Langley Research Center (LaRC) is to pioneer advances in NDE and structural health monitoring (SHM) through fundamental scientific research, technology development, and transferring these to the scientific and aerospace communities. This research supports a variety of NASA missions in space operations, exploration and aeronautics. The work presented will focus on the development of advanced inspection systems to detect critical flaws in both metallic and non-metallic materials and structures for aerospace applications. The emphasis is on increasing the performance of inspection systems to provide defect detection and quantitative characterization of the material state. LaRC NDE utilizes expertise in computational ultrasonic, thermal and eddy current simulations to reduce measured responses to size and locations of flaws, establish technique limitations and optimize performance. This presentation will highlight research into five strategic areas: (1) The development of novel solutions using state-of-the-art NDE technologies such as eddy current, ultrasound, thermography and x-ray computed tomography; (2) Research in the development of unique NDE technologies such as terahertz, wavefield imaging and nonlinear ultrasound; (3) The application of both computational and analytic models to NDE problems; (4) The development of advanced analytic methods to interpret large complex data sets; and (5) Advanced methods of applying and interrogating sensors for structural health monitoring.

NDE↗

Probing Complex Chemical Processes at the Molecular Level with Vibrational Spectroscopy and X-ray Tools

Understanding the origins of structure and bonding at the molecular level in complex chemical systems spanning magnitudes in length and time is of paramount interest in physical chemistry. Here, we have coupled vibrational spectroscopy and X-ray based techniques with a series of microreactors and aerosol beams to tease out intricate and sometimes subtle interactions, such as hydrogen bonding, proton transfer, and noncovalent interactions. This allows for unraveling the self-assembly of arginine-oleic acid complexes in an aqueous solution and growth processes in a metal–organic framework. Terahertz and infrared spectroscopy provide an intimate view of the hydrogen-bond network and associated phase changes with temperature in neopentyl glycol. The hydrogen-bond network in aqueous glycerol aerosols and levels of protonation of nicotine in aqueous aerosols are visualized. Future directions in probing the hydrogen-bond networks in deep eutectic solvents and organic frameworks are described, and we suggest how X-ray scattering coupled to X-ray spectroscopy can offer insight into the reactivity of organic aerosols.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Broadband Continuous Single-mode Tuning of a Short-cavity Quantum-cascade VECSEL

Changing the length of a laser cavity is a simple technique for continuously tuning the wavelength of a laserbutis rarelyused for broad fractional tuning, with a notable exception of the diode laser VCSEL1,2. This is because, to avoid mode hopping, the cavity must be keptopticallyshort to ensure a large free-spectral-range (FSR) compared to the gain bandwidth of the amplifying material. Terahertz quantum-cascade (QC) lasers are ideal candidates for such a short cavity scheme as they demonstrate exceptional gain bandwidths (up to octave spanning) and can be integrated with broadband amplifying metasurfaces. We present such a QC-metasurface based vertical-external-cavity surface-emitting-laser (VECSEL) that exhibits over 20% continuous fractional tuning of a single laser mode. Such tuning is possible because the metasurface has sub-wavelength thickness which allows lasing on low-order Fabry-Pérot cavity modes. Good beam quality and high output power are simultaneously obtained.

Christopher A Curwen↗

Silicon micromachined waveguides for millimeter and submillimeter wavelengths

The majority of radio receivers, transmitters, and components operating at millimeter and submillimeter wavelengths utilize rectangular waveguides in some form. However, conventional machining techniques for waveguides operating above a few hundred GHz are complicated and costly. This paper reports on the development of silicon micromachining techniques to create silicon-based waveguide circuits which can operate at millimeter and submillimeter wavelengths. As a first step, rectangular WR-10 waveguide structures have been fabricated from (110) silicon wafers using micromachining techniques. The waveguide is split along the broad wall. Each half is formed by first etching a channel completely through a wafer. Potassium hydroxide is used to etch smooth mirror-like vertical walls and LPCVD silicon nitride is used as a masking layer. This wafer is then bonded to another flat wafer using a polyimide bonding technique and diced into the U-shaped half wavelengths. Finally, a gold layer is applied to the waveguide walls. Insertion loss measurements show losses comparable to those of standard metal waveguides. It is suggested that active devices and planar circuits can be integrated with the waveguides, solving the traditional mounting problems. Potential applications in terahertz instrumentation technology are further discussed.

Yap, Markus↗

Electro-Optical Measurement Techniques

Utilize the unique characteristics of photons across different regions of the electromagnetic spectrum to probe the optical and electronic properties of chemical systems, materials and devices for energy conversion technologies.

absorption↗

Ultrafast Terahertz Field Control of the Emergent Magnetic and Electronic Interactions at Oxide Interfaces

Ultrafast electric-field control of emergent electronic and magnetic states at oxide interfaces offers exciting prospects for the development of the next generation of energy-efficient devices. Here, it is demonstrated that the electronic structure and emergent ferromagnetic interfacial state in epitaxial LaNiO3/CaMnO3 superlattices can be effectively controlled using intense, single-cycle THz electric-field pulses. A suite of advanced X-ray spectroscopic techniques is employed to measure a detailed magneto-optical profile and the thickness of the ferromagnetic interfacial layer. Then, a combination of time-resolved and temperature-dependent optical measurements is used to disentangle several correlated electronic and magnetic processes driven by ultrafast, high-field THz pulses. Sub-picosecond non-equilibrium Joule heating of the electronic system is observed, ultrafast demagnetization of the ferromagnetic interfacial layer, and slower dynamics indicative of a change in the magnetic state of the superlattice due to the transfer of spin-angular momentum to the lattice. These findings suggest a promising avenue for the efficient control of 2D ferromagnetic states at oxide interfaces using ultrafast electric-field pulses.

X-ray spectroscopy and scattering↗

Development of Natural Flaw Samples for Evaluating Nondestructive Testing Methods for Foam Thermal Protection Systems

Low density polyurethane foam has been an important insulation material for space launch vehicles for several decades. The potential for damage from foam breaking away from the NASA External Tank was not realized until the foam impacts on the Columbia Orbiter vehicle caused damage to its Leading Edge thermal protection systems (TPS). Development of improved inspection techniques on the foam TPS is necessary to prevent similar occurrences in the future. Foamed panels with drilled holes for volumetric flaws and Teflon inserts to simulate debonded conditions have been used to evaluate and calibrate nondestructive testing (NDT) methods. Unfortunately the symmetric edges and dissimilar materials used in the preparation of these simulated flaws provide an artificially large signal while very little signal is generated from the actual defects themselves. In other words, the same signal are not generated from the artificial defects in the foam test panels as produced when inspecting natural defect in the ET foam TPS. A project to create more realistic voids similar to what actually occurs during manufacturing operations was began in order to improve detection of critical voids during inspections. This presentation describes approaches taken to create more natural voids in foam TPS in order to provide a more realistic evaluation of what the NDT methods can detect. These flaw creation techniques were developed with both sprayed foam and poured foam used for insulation on the External Tank. Test panels with simulated defects have been used to evaluate NDT methods for the inspection of the External Tank. A comparison of images between natural flaws and machined flaws generated from backscatter x-ray radiography, x-ray laminography, terahertz imaging and millimeter wave imaging show significant differences in identifying defect regions.

Workman, Gary L.↗

Terahertz technology and applications

Despite great scientific interest since at least the 1920's, the THz frequency range remains on e of the least tapped regions of the electromagnetic spectrum. Sandwiched between traditional microwave and optical technologies where there is a limited atmospheric propagation path, little commercial emphasis has been placed on THz systems. This has, perhaps fortunately, preserved some unique science and applications for tomorrow's technologies. For over 25 years the sole niche for THz technology has been in the high resolution spectroscopy and remote sensing areas where heterodyne and Fourier transform techniques have allowed astronomers, chemists, Earth, planetary and space scientists to measure, catalog and map thermal emission lines for a wide variety of lightweight molecules. As it turns out, no where else in the electromagnetic spectrum do we receive so much information about these chemical species. In fact, the universe is bathed in THz energy, most of it going unnoticed and undetected.

THz electromagnetic spectrum↗

Near-field imaging and spectroscopy of terahertz resonators and metasurfaces [Invited]

Terahertz (THz) metasurfaces have become a key platform for engineering light-matter interaction at THz frequencies. They have evolved from simple metallic resonator arrays into tunable and programmable devices, displaying ultrafast modulation rates and incorporating emerging quantum materials. The electrodynamics which govern metasurface operation can only be directly revealed at the scale of subwavelength individual metasurface elements, through sampling their evanescent fields. It requires near-field spectroscopy and imaging techniques to overcome the diffraction limit and provide spatial resolution down to the nanoscale. Through a series of case studies, this review provides an in-depth overview of recently developed THz near-field microscopy capabilities for research on metamaterials.

Hale, Lucy L. (ORCID:0000000176544272)↗

Low-loss monolithic transmission lines for submillimeter and terahertz frequency applications

The design and construction of low-loss monolithic transmission lines are critical to systems which require that terahertz-power be guided to the antenna front ends. Two types of novel monolithic guiding structures, designed for the 0.3-2.0 THz and 0.1-0.3 THz ranges, respectively, are proposed. The novel waveguides are constructed from dielectric materials and structures which are available in monolithic technology so that the integration of active devices is possible. Propagation in each of the waveguides is characterized over relevant frequency ranges by applying a mode-matching technique, which takes into account all forms of electromagnetic coupling as well as losses in the dielectrics. The structures are predicted to exhibit excellent power confinement and low losses.

Engel, Andrew G., Jr.↗

Noninvasive Near‐Field Spectroscopy of Single Subwavelength Complementary Resonators

Abstract Subwavelength metallic resonators provide a route to achieving strong light–matter coupling by means of tight confinement of resonant electromagnetic fields. Investigation of such resonators however often presents experimental difficulties, particularly at terahertz (THz) frequencies. A single subwavelength resonator interacts weakly with THz beams, making it difficult to probe it using far‐field methods, whereas arrays of resonators exhibit inter‐resonator coupling, which affect the resonator spectral signature and field confinement. Here, traditional far‐field THz spectroscopy is systematically compared with aperture‐type THz near‐field microscopy for investigating complementary THz resonators. While the far‐field method proves impractical for measuring single resonators, the near‐field technique gives high signal‐to‐noise spectral information, only achievable in the far‐field with resonator arrays. At the same time, the near‐field technique allows to analyze single resonators without significant interaction with the near‐field probe. Furthermore, the near‐field technique allows highly confined fields and surface waves to be mapped in space and time. This information gives invaluable insight into spectral response in resonator arrays. This near‐field microscopy and spectroscopy method enables investigations of strong light–matter coupling at THz frequencies in the single‐resonator regime.

Hale, Lucy L.↗

ISO Guest Observer Data Analysis and LWS Instrument Team Activities

We have designed and fabricated infrared filters for use at wavelengths greater than or equal to 15 microns. Unlike conventional dielectric filters used at the short wavelengths, ours are made from stacked metal grids, spaced at a very small fraction of the performance wavelengths. The individual lattice layers are gold, the spacers are polyimide, and they are assembled using integrated circuit processing techniques; they resemble some metallic photonic band-gap structures. We simulate the filter performance accurately, including the coupling of the propagating, near-field electromagnetic modes, using computer aided design codes. We find no anomalous absorption. The geometrical parameters of the grids are easily altered in practice, allowing for the production of tuned filters with predictable useful transmission characteristics. Although developed for astronomical instrumentation, the filters are broadly applicable in systems across infrared and terahertz bands.

Oliversen, Ronald J.↗

Designer Infrared Filters using Stacked Metal Lattices

We have designed and fabricated infrared filters for use at wavelengths greater than or equal to 15 microns. Unlike conventional dielectric filters used at the short wavelengths, ours are made from stacked metal grids, spaced at a very small fraction of the performance wavelengths. The individual lattice layers are gold, the spacers are polyimide, and they are assembled using integrated circuit processing techniques; they resemble some metallic photonic band-gap structures. We simulate the filter performance accurately, including the coupling of the propagating, near-field electromagnetic modes, using computer aided design codes. We find no anomalous absorption. The geometrical parameters of the grids are easily altered in practice, allowing for the production of tuned filters with predictable useful transmission characteristics. Although developed for astronomical instrumentation, the filters arc broadly applicable in systems across infrared and terahertz bands.

Smith, Howard A.↗

Raman and Terahertz Spectroscopy of Low-Frequency Chiral Phonons in Amino Acids

Chiral phonons are mirror-symmetric vibrations with nonzero angular momenta that correspond to twisting and rotational motions of multiple atoms. In chiral crystals, these include low-energy terahertz (THz)-range vibrations of the molecular segments involving dozens of atoms with energies sensitive to molecular chirality. Here, we present spectral signatures of chiral phonons in circularly polarized Raman optical activity (ROA) spectra from enantiomers of amino acid crystals. Along with complementary THz circular dichroism (TCD) measurements, our ROA data reveal several vibrational bands in enantiomers of valine, alanine, tyrosine, and proline between 30 and 150 cm –1 (∼1–4.5 THz) that exhibit opposite intensities. Density functional theory calculations confirm their assignment to twisting and shearing molecular motions. The simultaneous registration of chiral phonon modes by ROA and TCD demonstrates the necessity of these complementary techniques to identify complex mirror-asymmetric vibrational modes and offers new insights into their interactions with circularly polarized light.

36 MATERIALS SCIENCE↗

Robust Optimization Design Algorithm for High-Frequency TWTs

Traveling-wave tubes (TWTs), such as the Ka-band (26-GHz) model recently developed for the Lunar Reconnaissance Orbiter, are essential as communication amplifiers in spacecraft for virtually all near- and deep-space missions. This innovation is a computational design algorithm that, for the first time, optimizes the efficiency and output power of a TWT while taking into account the effects of dimensional tolerance variations. Because they are primary power consumers and power generation is very expensive in space, much effort has been exerted over the last 30 years to increase the power efficiency of TWTs. However, at frequencies higher than about 60 GHz, efficiencies of TWTs are still quite low. A major reason is that at higher frequencies, dimensional tolerance variations from conventional micromachining techniques become relatively large with respect to the circuit dimensions. When this is the case, conventional design- optimization procedures, which ignore dimensional variations, provide inaccurate designs for which the actual amplifier performance substantially under-performs that of the design. Thus, this new, robust TWT optimization design algorithm was created to take account of and ameliorate the deleterious effects of dimensional variations and to increase efficiency, power, and yield of high-frequency TWTs. This design algorithm can help extend the use of TWTs into the terahertz frequency regime of 300-3000 GHz. Currently, these frequencies are under-utilized because of the lack of efficient amplifiers, thus this regime is known as the "terahertz gap." The development of an efficient terahertz TWT amplifier could enable breakthrough applications in space science molecular spectroscopy, remote sensing, nondestructive testing, high-resolution "through-the-wall" imaging, biomedical imaging, and detection of explosives and toxic biochemical agents.

Wilson, Jeffrey D.↗

Lightwave-electronic harmonic frequency mixing

Electronic frequency mixers are fundamental building blocks of electronic systems. Harmonic frequency mixing in particular enables broadband electromagnetic signal analysis across octaves of spectrum using a single local oscillator. However, conventional harmonic frequency mixers do not operate beyond hundreds of gigahertz to a few terahertz. If extended to the petahertz scale in a compact and scalable form, harmonic mixers would enable field-resolved optical signal analysis spanning octaves of spectra in a monolithic device without the need for frequency conversion using nonlinear crystals. Here, we demonstrate lightwave-electronic harmonic frequency mixing beyond 0.350 PHz using plasmonic nanoantennas. We demonstrate that the mixing process enables complete, field-resolved detection of spectral content far outside that of the local oscillator, greatly extending the range of detectable frequencies compared to conventional heterodyning techniques. Our work has important implications for applications where optical signals of interest exhibit coherent femtosecond-scale dynamics spanning multiple harmonics.

Science & Technology - Other Topics↗