Experimental Results From the Thermal Energy Storage-1 (TES-1) Flight Experiment

The Thermal Energy Storage (TES) experiments are designed to provide data to help researchers understand the long-duration microgravity behavior of thermal energy storage fluoride salts that undergo repeated melting and freezing. Such data, which have never been obtained before, have direct application to space-based solar dynamic power systems. These power systems will store solar energy in a thermal energy salt, such as lithium fluoride (LiF) or a eutectic of lithium fluoride/calcium difluoride (LiF-CaF2) (which melts at a lower temperature). The energy will be stored as the latent heat of fusion when the salt is melted by absorbing solar thermal energy. The stored energy will then be extracted during the shade portion of the orbit, enabling the solar dynamic power system to provide constant electrical power over the entire orbit. Analytical computer codes have been developed to predict the performance of a spacebased solar dynamic power system. However, the analytical predictions must be verified experimentally before the analytical results can be used for future space power design applications. Four TES flight experiments will be used to obtain the needed experimental data. This article focuses on the flight results from the first experiment, TES-1, in comparison to the predicted results from the Thermal Energy Storage Simulation (TESSIM) analytical computer code.

Jacqmin, David↗

Insights from a coupled thermo-hydro-mechanical analysis of a layered high-temperature thermal energy storage reservoir

Coupled thermal-hydraulic-mechanical (THM) modeling is applied to investigate the performance of a seasonal high-temperature aquifer thermal energy storage operation based on data and conditions from current site investigations at the Geostorage Forsthaus pilot project in Bern (Switzerland). The model includes subhorizontal sand lenses of various lengths and dips that are embedded in a low permeability clay matrix. Thermal energy storage is simulated by seasonal injection and withdrawal of hot (up to 90 °C) water from a main well, with reservoir pressure regulated by two auxiliary wells at a distance of about 70 m from the main well. The results show how targeted injection into deeper permeable storage formations, along with active deep well pressure control, can effectively minimize geomechanical impact and the potential risk of damaging subsurface storage and sealing formations, or even surface facilities. With such pressure control, the subsurface mechanical responses are dominated by thermal strain and stress, which can be monitored with subsurface fiber optics. The study demonstrates how coupled THM modeling can be applied for the design of a safe and efficient thermal energy storage operation, and how subsurface fiber optic monitoring can be applied for performance confirmation, allowing for more confident operational forecasting.

Rutqvist, Jonny↗

Geological Thermal Energy Storage (GeoTES) Charged with Solar Thermal Technology Using Depleted Oil/Gas Reservoirs and Carnot-Battery Technique Using Shallow Reservoirs: Preprint

Geological thermal energy storage (GeoTES) utilizes the underground reservoirs to storage and dispatch energy per given demand schedule over a time scale up to seasons of a year. The energy input can be of various sources/forms; in this paper, we investigate 1) the GeoTES technology with solar thermal hybridization and using depleted oil/gas reservoirs; 2) the GeoTES technology with heat pumps charged by excess renewable electricity and using low-temperature shallow reservoirs. For each GeoTES technology, we carry out the suitability analysis of candidate reservoirs, develop initial techno-economic models, and validate the model with selected case study. The paper provides an overview of our technical progress on the topics of concern and aims to promote a wider acceptance of the GeoTES technologies in the future energy market.

Carnot battery↗

Thermal energy storage in concrete: Review, testing, and simulation of thermal properties at relevant ranges of elevated temperature

This study examines the thermal performance of concrete used for thermal energy storage (TES) applications. The influence of concrete constituents (aggregates, cementitious materials, and fibers) on the thermal conductivity and specific heat are summarized based on literature and via experimentation at elevated temperatures. It is indicated that concrete with siliceous aggregate, low water/cement ratios, and steel fibers produces better overall thermal properties. The results of literature review and laboratory testing are used for numerical simulation to evaluate the impact of concrete thermal property variability on TES capabilities. The TES module consists of the heat exchanger and surrounding concrete as the storage media. Both idealized cases without heat loss and realistic cases with insulation and heat losses are considered. Furthermore, the result shows that conventional concrete mixes can be tailored to decrease the module charge/discharge durations and increase the amount of thermal energy storage.

25 ENERGY STORAGE↗

Experimental Results from the Thermal Energy Storage-2 (TES-2) Flight Experiment

Thermal Energy Storage-2 (TES-2) is a flight experiment that flew on the Space Shuttle Endeavour (STS-72), in January 1996. TES-2 originally flew with TES-1 as part of the OAST-2 Hitchhiker payload on the Space Shuttle Columbia (STS-62) in early 1994. The two experiments, TES-1 and TES-2 were identical except for the fluoride salts to be characterized. TES-1 provided data on lithium fluoride (LiF), TES-2 provided data on a fluoride eutectic (LiF/CaF2). Each experiment was a complex autonomous payload in a Get-Away-Special payload canister. TES-1 operated flawlessly for 22 hr. Results were reported in a paper entitled, Effect of Microgravity on Materials Undergoing Melting and Freezing-The TES Experiment, by David Namkoong et al. A software failure in TES-2 caused its shutdown after 4 sec of operation. TES-1 and 2 were the first experiments in a four experiment suite designed to provide data for understanding the long duration microgravity behavior of thermal energy storage salts that undergo repeated melting and freezing. Such data have never been obtained before and have direct application for the development of space-based solar dynamic (SD) power systems. These power systems will store energy in a thermal energy salt such as lithium fluoride or a eutectic of lithium fluoride/calcium difluoride. The stored energy is extracted during the shade portion of the orbit. This enables the solar dynamic power system to provide constant electrical power over the entire orbit. Analytical computer codes were developed for predicting performance of a space-based solar dynamic power system. Experimental verification of the analytical predictions were needed prior to using the analytical results for future space power design applications. The four TES flight experiments were to be used to obtain the needed experimental data. This paper will address the flight results from the first and second experiments, TES-1 and 2, in comparison to the predicted results from the Thermal Energy Storage Simulation (TESSIM) analytical computer code. An analysis of the TES-2 data was conducted by Cleveland State University Professor, Mounir Ibrahim. TESSIM validation was based on two types of results; temperature history of various points on the containment vessel and TES material distribution within the vessel upon return from flight. The TESSIM prediction showed close comparison with the flight data. Distribution of the TES material within the vessel was obtained by a tomography imaging process. The frozen TES material was concentrated toward the colder end of the canister. The TESSIM prediction indicated a similar pattern. With agreement between TESSIM and the flight data, a computerized representation was produced to show the movement and behavior of the void during the entire melting and freezing cycles.

Tolbert, Carol↗

Thermal Stability of Silica for Application in Thermal Energy Storage: Preprint

Free from siting constraints, thermal energy storage (TES) shows promise as an economical alternative to traditional pumped-storage hydropower (PSH) and compressed air energy storage (CAES). As potential thermal energy storage media, many solid particles demonstrate stability over wide temperature ranges which allows for increased sensible energy storage density and is essential in achieving low-cost storage. Silica sand, in the form of a-quartz, is one such candidate. This work presents a brief review of relevant silica thermophysical properties and further investigates the thermal stability of silica particles as a candidate TES media by subjecting them to two different thermal campaigns: (1) a 500-hour thermal treatment at 1200°C under varied atmospheres; and (2) cycling 25, 50, and 100 times between 300°C and 1200°C. For both campaigns, particle stability is examined by means of pre- and post-treatment Mie scattering. An additional XRD analysis is conducted for the 500-hour treatment in air. Results indicate limited changes in both particle distribution and crystallographic structure which is promising for the application as solid particle media for thermal energy storage.

27 ARPA - Advanced Research Projects Agency-Energy↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Fluidized-bed heat exchanger for conversion of thermal energy to electricity

The present disclosure describes heat exchangers for converting thermal energy stored in solid particles to electricity. Electro-thermal energy storage converts off-peak electricity into heat for thermal energy storage, which may be converted back to electricity, for example during peak-hour power generation. The heat exchanger for converting thermal energy stored in solid particles to electricity enables the conversion of thermal energy into electrical energy for redistribution to the grid. In some embodiments, pressurized fluidized-bed heat exchangers may achieve efficient conversion of thermal energy to electricity by providing direct contact of the solid particles with a gas stream.

Ma, Zhiwen↗

Experimental Results from the Thermal Energy Storage-1 (TES-1) Flight Experiment

The Thermal Energy Storage-1 (TES-1) is a flight experiment that flew on the Space Shuttle Columbia (STS-62), in March 1994, as part of the OAST-2 mission. TES-1 is the first experiment in a four experiment suite designed to provide data for understanding the long duration microgravity behavior of thermal energy storage fluoride salts that undergo repeated melting and freezing. Such data have never been obtained before and have direct application for the development of space-based solar dynamic (SD) power systems. These power systems will store solar energy in a thermal energy salt such as lithium fluoride or calcium fluoride. The stored energy is extracted during the shade portion of the orbit. This enables the solar dynamic power system to provide constant electrical power over the entire orbit. Analytical computer codes have been developed for predicting performance of a spaced-based solar dynamic power system. Experimental verification of the analytical predictions is needed prior to using the analytical results for future space power design applications. The four TES flight experiments will be used to obtain the needed experimental data. This paper will focus on the flight results from the first experiment, TES-1, in comparison to the predicted results from the Thermal Energy Storage Simulation (TESSIM) analytical computer code. The TES-1 conceptual development, hardware design, final development, and system verification testing were accomplished at the NASA lewis Research Center (LeRC). TES-1 was developed under the In-Space Technology Experiment Program (IN-STEP), which sponsors NASA, industry, and university flight experiments designed to enable and enhance space flight technology. The IN-STEP Program is sponsored by the Office of Space Access and Technology (OSAT).

Wald, Lawrence W.↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Thermal Energy Storage

The concept of thermal energy storage (TES) can be traced back to early 19th century, with the invention of the ice box to prevent butter from melting. Modern TES development began with building heating and cooling and concentrated solar thermal technologies for power generation in the early 1900s and late 1970s, respectively. TES systems provide many advantages compared with other long-duration energy storage (LDES) technologies, which include low costs, long operational lives, high energy density, synchronous power generation capability with inertia that inherently stabilizes the grid, and the ability to output both heat and electricity. TES Use Cases TES technologies can couple with most renewable energy systems, including wind, photovoltaic, and concentrated solar thermal energy, and can be used for heat-to-heat, heat-to-electricity, electricity-to-heat, and electricity-to-electricity (bidirectional electricity) applications. The three types of TES that have heat as an input or output are grouped together for the purposes of this report. Retrofitting retired thermal power plants can be a potential cost-effective option for TES with electricity output because they both use a similar thermal-to-electricity type of conversion. Additionally, TES can directly serve heat demand for buildings and industrial processes, displacing fossil fuels to achieve broad decarbonization. Bidirectional Electricity Figure 1 shows a bidirectional electricity TES (ETES) architecture that is emerging as a prime technology for LDES at a grid scale. The ETES technology can utilize existing TES technology infrastructures, has no geological limitations (such as mountains and water for pumped storage hydro, underground natural caverns for compressed-air energy storage, etc.), and is capable of deployment anywhere in the United States and the world for broad uses. Particularly, ETES technology can be placed at retired fossil-fueled thermal power plants to reuse decommissioned assets, protect job security in associated communities, and provide resilient and high-inertia (i.e., spinning) power to the grid. Heat Input and Output There also are many ways to integrate TES within heat-to-electricity, heat-to-heat, and electricity-to-heat applications, such as those used in concentrating solar power (CSP), buildings, district heating, and industry process heat applications. These categories can be further classified for low- and high-temperature applications. High-temperature thermal energy storage (HTTES) heat-to-electricity TES applications are currently associated with CSP deployments for power generation. TES with CSP has been deployed in the Southwestern United States with rich solar resources and has proved its value to the electric grid. Electricity-to-heat and heat-to-heat HTTES applications present great potential for decarbonizing energy-intensive industrial process heat applications [8, 9], such as iron ore processing, iron smelting, cement production, glass manufacturing, mineral processing, and chemical production. Some industrial processes require process heat at temperatures > 1,400°C, so HTTES can be utilized to reduce fuel consumption in those processes through fuel, oxidizer, and process material pre-heating. Thermal energy storage for augmenting existing industrial process heat applications makes a much more attractive economic case because the energy penalty due to thermal-to-electric conversion is eliminated. Co-located applications of power production and heat also can add to the value stacking of integrating utility-scale TES; however, these scenarios are very case specific and not practically possible in many cases. These constraints are primarily attributed to the existing infrastructure being designed, developed, and constructed for many decades around the most economically feasible technologies, such as electricity and a selection of fossil fuels for heat input. Low-temperature TES can be utilized for building and district heating and cooling, as well as some process heat applications in electricity-to-heat and heat-to-heat configurations. Lower temperature TES (LTTES) can be added to heat pump equipment (electric input), either directly interacting with the refrigerant in the condenser or evaporator, or through a secondary heat transfer fluid. It also can be integrated in the building envelope or within the ducts of the heating, ventilation, and air conditioning (HVAC) system. Cost-effective integration of TES into buildings adds significant cost, and it is one of the key barriers preventing the commercialization and deployment of TES. The optimal strategy for integrating TES with buildings has yet to be determined for various applications of TES. Nevertheless, thermal storage materials are far less costly per unit of energy stored than electricity storage materials. This means that thermal storage has the potential to reduce the cost to society of energy storage.

25 ENERGY STORAGE↗

Thermal Energy Storage in Commercial Buildings

Space heating and cooling account for as much as 40% of energy used in commercial buildings. Aligning this energy consumption with renewable energy generation through practical and viable energy storage solutions will be pivotal in achieving 100% clean energy by 2050. Integrated on-site renewable energy sources and thermal energy storage systems can provide a significant reduction of carbon emissions and operational costs for the building owner.

buildings energy storage↗

Thermo-Hydrological Modeling of Thermal Energy Storage in a Depleted Oil Reservoir

Thermal energy storage in oil and gas reservoirs leverages the existing surface and subsurface infrastructure, which can pave the way for economic production of geothermal energy. Existing studies on geothermal energy storage are focused mostly on the use of aquifers with more homogeneous rock and fluid properties. Coupling of heat and fluid flow in a multiphase-multicomponent system, such as an oil reservoir, is imperative especially if existing oil field assets need to be repurposed as required for a sustainable energy transition. The objective is to model the subsurface thermo-hydrological processes associated with reservoir performance and operational sustainability. The model evaluates formation pressure and temperature within the reservoir and at the injection/production wells during multiple charge and discharge cycles. Hot water (approximately 200 degrees C) heated by Concentrating Solar Power (CSP) at high pressure is injected into the existing oil reservoir for storage and produced as thermal energy for power generation, which will be accompanied by enhanced oil recovery. To demonstrate the coupled fluid and heat flow during the injection/production cycle in the subsurface reservoir, TOUGH3 (developed by Berkeley Lab) is used to simulate the thermo-hydrological (TH) processes in a multiphase, multicomponent system. Two well geometries are considered within the reservoir grid: 1) a single-well huff-n-puff system (same well is used for injection and production), and 2) an isolated injection-production well doublet. Seasonal charge and discharge cycling are implemented based on the scheduling specified in the model input file. The model reports pressure, temperature, enthalpy, liquid fluxes, heat fluxes, pore velocities, and changes in porosity & permeability due to temperature and pressure variations during the cyclic Reservoir Thermal Energy Storage (RTES) operations. The results from the simulations can be used to optimize the operational parameters (such as well spacing and injection/production rates) and round-trip efficiency for surface power-plants coupled with thermal energy storage over time. They can also serve as important inputs for levelized cost of storage estimations. The research will help to design and integrate surface renewable energy sources, such as concentrating solar power (CSP), with RTES to help balance out power supply and demand on the grid.

CSP↗

Efficient Thermal Energy Storage with Radial Flow in Packed Beds

Thermal energy storage (TES) is a way to store excess heat in order to generate power later. These types of systems are valuable in the solar industry, where power production can still occur when sunlight is not available. This not only increases system flexibility, it drives down the cost of electricity. One option to store thermal energy is with a packed bed where the storage media resides in a cylindrical container. Flow from one end of the cylinder to the other deposits or recovers heat (axial flow). While a promising technology in terms of energy storage, it exhibits a high pressure drop that lowers overall system efficiency. This project seeks to flow the heat transfer fluid through the storage media in the radial direction. This system offers the potential to retain reasonable thermal performance while substantially lowering the pressure drop. The overall goal was to assess the performance of radial flow experimentally and numerically. Three main designs were considered in this work. The first system utilized a central pipe and four receiving pipes near the wall. The second system utilized a central pipe and an annulus with holes near the wall. The last approach considered segmenting the bed so only select zones would receive flow in the radial direction. In a high-aspect ratio system, the hole patterns in the piping are important for ensuring even flow into the bed, and a major design effort was testing holes patterns to promote even flow. The four pipe system was shown to be not feasible, as preferential flow paths occur that do not allow even and full heating of the packed bed. The annular system can lead to even flow, but the results show this is better accomplished through larger piping instead of considering variations in the hole pattern along the axial length of the pipe. Segmenting the bed can lead to similar exergetic performance when compared to axial or radial flow. However, the pressure drop in the segmented design is likely too high for practical implementation. A baseline commercial design showed exergetic efficiencies for axial, radial, and radial segments of 81.6%, 82.8%, and 80.2%, respectively. Pressure drop for the axial and radial results were 2.36 psi and 2.45 psi, respectively, with segments being nearly an order of magnitude higher. At these large scales, the aspect ratio of the system is important. From a baseline of 0.64, an aspect ratio of 0.32 for radial flow showed an exergetic efficiency of 86% but a pressure drop of 5.39 psi. All of these results provide new insights into packed bed thermal energy storage with radial flow. Competing effects must be considered when designing a radial system, and results show a radial design can show strong thermal results at the expense of system efficiencies from pressure drop. The COMSOL models used in this analysis are available to the public and other researchers. Public benefits include a potential increase in the efficiency of packed bed thermal energy storage. Higher efficiency in storage promotes green energy technologies while reducing costs.

14 SOLAR ENERGY↗

Thermal Energy Distribution System (TEDS) Operating Modes and Control Strategies

A Thermal Energy Delivery System was constructed at the Idaho National Laboratory for demonstrating distribution of thermal energy to and from co-located systems sited in the INL Dynamic Energy Transport and Integration Laboratory (DETAIL). DETAIL includes a flow loop simulating a pressurized water reactor, a high-temperature steam electrolysis unit and a thermal energy storage system. This report discusses the various operating modes and control strategies for enabling simultaneous, flexible and efficient transfer of heat from thermal energy sources to end users.

25 ENERGY STORAGE↗

Combined Heat and Power Technology Fact Sheet Series: Thermal Energy Storage

This fact sheet provides an overview of thermal energy storage (TES) technologies, which heat or cool a storage medium and, when needed, deliver the stored thermal energy to meet heating or cooling needs. TES systems are used in commercial buildings, industrial processes, and district energy installations to deliver stored thermal energy during peak demand periods, thereby reducing peak energy use. TES systems are often integrated with electric or absorption chillers to reduce peak electricity costs and, in the case of new construction, to reduce capital costs by optimizing chiller size. TES technologies can support sites that have either renewable or fossil power generation, including combined heat and power (CHP) installations. With CHP, TES can help optimize equipment size by reducing the required peak CHP thermal capacity and increasing annual CHP usage. TES can also provide turbine inlet cooling for gas turbines used in CHP applications, which increases power production in hot ambient conditions.

Combined Heat and Power, CHP, Thermal Energy, Tech↗

Seasonal Thermal Energy Storage Program

The Seasonal Thermal Energy Storage (STES) Program designed to demonstrate the storage and retrieval of energy on a seasonal basis using heat or cold available from waste or other sources during a surplus period is described. Factors considered include reduction of peak period demand and electric utility load problems and establishment of favorable economics for district heating and cooling systems for commercialization of the technology. The initial thrust of the STES Program toward utilization of ground water systems (aquifers) for thermal energy storage is emphasized.

Minor, J. E.↗

Nature-inspired lotus-shaped fins combined with hybrid nanoparticles and metal foam for high-performance latent heat thermal energy storage

Latent heat thermal energy storage (LHTES) systems play a critical role in renewable energy integration by providing high energy density and nearly isothermal operation during phase transitions. However, their performance is often limited by slow melting/charging rates, which motivates the search for enhanced heat transfer designs. This study investigates the melting behavior of RT-82 phase change material (PCM) using novel lotus-shaped fins combined with copper metal foam and conductive graphene nanoparticles and carbon nanotubes. A two-dimensional enthalpy-porosity model in ANSYS Fluent was developed to simulate the charging/melting process, capturing non-thermal equilibrium between the foam and PCM/nano-PCM. In this study, effects of fin geometry, nanoparticle concentration, and foam porosity on melting dynamics and cost-performance trade-offs were investigated. Results showed that natural convection accelerated melting by ~12% compared to conduction-only scenarios. Optimized lotus-shaped fins with higher fin density (T3F4 and T3F10) achieved up to 63% faster melting relative to sparse configurations. Graphene nanoparticles improved thermal conductivity, with a 6% volume fraction, by reducing melting time by ~6.9%, while their combination with 75% porosity foam achieved a maximum reduction in the melting time of ~51% compared to pure PCM. Cost-performance analysis identified T3F4 as the most balanced design, offering rapid thermal response without excessive material costs, while moderate-density designs like T3S6 provided economical alternatives with acceptable performance. These results highlight the performance enhancement that can be achieved by integrating bio-inspired fins, nanoparticles, and foams, into compact and efficient LHTES for solar heating, building thermal management, and industrial waste-heat recovery applications.

25 ENERGY STORAGE↗

Computational fluid dynamic analysis of a novel particle-to-air fluidized-bed heat exchanger for particle-based thermal energy storage applications

Long-duration energy storage technologies are being targeted to enable cost-effective, decarbonized energy systems. Particle-based thermal energy storage systems are one promising technology by storing excess electricity or heat as sensible thermal energy in inexpensive, solid, inert particles. These systems are only possible if an effective and economical particle-to-working fluid heat exchanger exists. This study predicts the performance of a proposed, direct-contact, particle-to-air, pressurized fluidized-bed heat exchanger using computational fluid dynamics. The common Eulerian-Eulerian framework for modeling fluidized beds is first benchmarked to experimental results at a previously untested operating condition and application. Then, the benchmarked model evaluates the performance of a proposed design for a commercial-scale version of the novel particle-to-air heat exchanger. The results show pressure drop and gas-phase approach temperatures are advantageous compared to other proposed designs for particle-to-air heat exchangers in the literature; approach temperatures were less than 5 °C and gas-phase pressure drop across the fluidized bed was 32 kPa. The model also highlights the importance of gas distributor design and representation in the Eulerian-Eulerian framework to control fluidization behavior. In conclusion, the model built and benchmarked in this study can be leveraged to advance the design and analysis of these heat exchangers critical to the deployment of a promising long-duration energy storage technology.

25 ENERGY STORAGE↗