Search NASA⌕ Search

SEARCH · Search NASA

Results for “Time at Temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Real-Time Temperature Field State Observer and Digital Replica to Support Cyber-Physical Testing

Cyber-physical testing is a class of experimental methods in which a system is partitioned into physical and numerical components to study its overall behavior. Transfer systems are typically needed to capture relevant interactions by enforcing appropriate interface conditions between the physical and numerical portions. While cyber-physical testing is often performed using lumped-parameter systems, thermomechanical cyber-physical testing requires the use of thermal actuators as transfer systems to apply a thermal condition over a spatially distributed region or surface. Thus, the interactions between the numerical and physical components are of a distributed nature, i.e., a field rather than point values. In this paper, we develop and experimentally validate a state observer for temperature fields to enable thermomechanical cyber-physical testing. The state observer provides continuous estimates of temperature over a surface of the thermal actuator using only temperature measurements at discrete locations. The estimated temperature field is then leveraged to account for localized mechanical defects in the interface condition. The method consists of building a digital replica of one portion of the control plant. By imposing defects in the digital replica it is used to generate and output the response of a thermal load pattern that represents that of a physical system with mechanical defects.

Manuel Salmeron↗

Thresholds of Temperature and Time for Mars Sample Return: Final Report of The Mars Sample Return Temperature-Time Tiger Team

The time-temperature tiger team (T4) was chartered by NASA and ESA to evaluate the risks to the scientific return of the MSR samples if they are exposed to temperatures between +30 and +60 ⁰C for different amounts of time. This team consists of 13 scientists, who were selected based on their scientific background to represent the scientific disciplines that are expected to be the ones that will be the most affected if such heating were to happen. The expertise of the team will help to understand whether exposing the MSR samples to temperatures between +30 and +60 ⁰C will pose any risk to the sample integrity and therefore, to future scientific investigations. Key processes identified by the T4 were: the release of volatiles by desorption and sublimation and release from condensed phases (interiors, decomposition, dehydration); chemical reactions including gas-gas and gas-solid; deliquescence of hygroscopic salts; acid/base interactions (potential for extreme pH conditions); aqueous redox reactions, isotopic exchange (aqueous phases, minerals, gasses, organic phases); condensation and freezing (in the after-heating cooling phase) and interactions with the sample tube materials. There is potential for multiple interactions and overlapping effects. For inorganic materials and the records they represent, over both long time scales (hours to days) and short time scales (minutes to hours) no temperature excursion above +30 °C could be accommodated without loss of science (Figure 1.1). While there will be some robust constituents (feldspars, quartz, pyroxenes, etc.) that are unaffected, there will also be some less robust constituents (salts, phyllosilicates, radicals, etc.) that are affected across all temperature ranges ≤60 °C. For organic materials, in particular organic biosignatures, the risks reflect that preservation is reliant on a number of processes, and a change in one component within a sample tube can affect another. For organic materials, over long timescales of hours to days no temperature excursion above +30 °C could be accommodated without loss of science, but over shorter time scales (minutes to hours), raising the temperature to 40 °C could be manageable without major disruption to science, whereas temperatures above 40 °C would lead to significant losses. The consideration of these findings by the MSR team will help to maintain the fidelity of samples returned from Mars in the future and maximize scientific return when analyzed in Earth laboratories.

Mark A Sephton↗

Literature Review of PuO 2 Calcination time and Temperature Data for Specific Surface Area

The literature has been reviewed in December 2011 for calcination data of plutonium oxide (PuO 2 ) from plutonium oxalate Pu(C 2 O 4 ) 2 precipitation with respect to the PuO 2 specific surface area (SSA). A summary of the literature is presented for what are believed to be the dominant factors influencing SSA, the calcination temperature and time. The PuO 2 from Pu(C 2 O 4 ) 2 calcination data from this review has been regressed to better understand the influence of calcination temperature and time on SSA. Based on this literature review data set, calcination temperature has a bigger impact on SSA versus time. However, there is still some variance in this data set that may be reflecting differences in the plutonium oxalate preparation or different calcination techniques. It is evident from this review that additional calcination temperature and time data for PuO 2 from Pu(C 2 O 4 ) 2 needs to be collected and evaluated to better define the relationship. The existing data set has a lot of calcination times that are about 2 hours and therefore may be underestimating the impact of heating time on SSA. SRNL recommends that more calcination temperature and time data for PuO 2 from Pu(C 2 O 4 ) 2 be collected and this literature review data set be augmented to better refine the relationship between PuO 2 SSA and its calcination parameters.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Time Series Surface Temperature of Variably Inundated Sediment across 30 North American Rivers

This dataset supports a broader study examining drivers of organic matter chemistry in variably inundated hyporheic zone sediments and further linking that chemistry to biogeochemical rates. The dataset provides surficial temperature time series that can be used to infer the dynamics of inundation prior to the collection of sediments. Those inferred inundation histories can then be used to help interpret variation in the organic matter chemistry. There are related data that will be published, such as FTICR-MS data on organic matter chemistry and sediment moisture. A data package with those data is forthcoming.This dataset is comprised of two folders: (1) ECA1_iButtonData and (2) ECA1_SitePhotos. The ECA1_iButtonData folder contains: (1) file-level metadata, (2) data dictionary, (3) field metadata, (4) installation methods, (5) iButton deployment protocol, (6) readme, and (7) folder of individual time series temperature csv files for each iButton sensor deployed. The ECA1_SitePhotos folder contains site photographs taken in the field. All files are .csv, .txt, .pdf, or .jpg.

54 ENVIRONMENTAL SCIENCES↗

Low Temperature Time-to-Explosion Experiments in the LLNL’s ODTX/P-ODTX System

Incidents caused by fire and some operations can heat energetic materials that may lead to thermal explosion and result in structural damage and casualty. Thus, explosive thermal sensitivity is an important topic for oilfield perforating operations and impacts perforating system performance and safety. Explosives have time-dependent temperature limits which can lead to thermal decomposition when exceeded and, under some circumstances, can result in performance losses and safety hazards. The One-Dimensional-Time to Explosion (ODTX) system at the Lawrence Livermore National Laboratory (LLNL) has been used for decades to characterize thermal safety of energetic materials. In this study, an integration of a pressure monitoring element has been added into the ODTX system (P-ODTX) to perform extended thermal experiments on HMX at three temperatures 160 °C, 170 °C and 185 °C. The tests generate time-temperature data as well as useful gas pressure data to assist with the thermal safety assessment of the energetics and systems that use the energetics. This report summarizes results of the 3 tests that were performed from July 2018 to November 2018.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Effects of aging time and temperature of Fe-1wt.%Cu on magnetic Barkhausen noise and FORC

Magnetic Barkhausen noise (MBN), hysteresis measurements, first order reversal curves (FORC), Vickers microhardness, and Transmission Electron Microscopy (TEM) analyses were performed on Fe-1wt.%Cu (Fe-Cu) samples isothermally aged at 700°C for 0.5 – 25 hours to obtain samples with different sized Cu precipitates and dislocation structures. Fe-Cu is used to simulate the thermal and irradiation-induced defects in copper-containing nuclear reactor materials such as cooling system pipes and pressure vessel materials. The sample series showed an initial increase followed by a decrease in hardness and coercivity with aging time, which is explained by Cu precipitates formation and growth as observed by TEM measurements. Further, the MBN envelope showed a continuous decrease in its magnitude and the appearance of a second peak with aging. Also, FORC diagrams showed multiple peaks whose intensity and location changed for different aging time. The changes in FORC diagrams are attributed to combined changes of the magnetic behavior due to Cu precipitate characteristics and dislocation structure. A second series of samples aged at 850°C, which is above the solid solution temperature of Fe-Cu, was studied to isolate the effects of dislocations. These samples showed a continuous decrease in MBN amplitude with aging time although the coercivity and hardness did not change significantly. The decrease of MBN amplitude and the appearance of the second MBN envelope peak are attributed to the changes in dislocation density and structure. This study shows that the effect of dislocations on MBN and FORC of Fe-Cu materials can vary significantly and should be considered in interpreting magnetic signatures.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗