Search NASASearch

SEARCH · Search NASA

Results for “Timing resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The ETROC2 as the Final Version for CMS Endcap Timing Layer (ETL) Upgrade

The ETROC (Endcap Timing Readout Chip) is being developed for the LGAD-based CMS Endcap Timing Layer (ETL) at HL-LHC. The ETL on each side of the interaction region will be instrumented with a two-disk system of MIP-sensitive LGAD (Low Gain Avalanche Diodes) silicon devices, read out by ETROCs for precision timing measurement with down to ~30 ps timing resolution per track. The ETROC is designed to handle a 16 x 16 pixel cell matrix, with each pixel being 1.3 mm x 1.3 mm to match the LGAD sensor pixel size. The front-end design for preamplifier and discriminator has been specifically optimized for the reduced LGAD signals, with enough flexibilities to meet the ETL specific needs for time resolution, power budget and radiation profile. The ETROC chip is implemented in a commercial 65nm CMOS process. Each channel consists of a preamplifier, a discriminator, a TDC used for TOA (Time Of Arrival) and TOT (Time Over Threshold) measurements, and a memory for data storage and readout. An in-pixel auto threshold calibration is included, along with a self-testing pattern generator. The TOT is used for time-walk correction of the TOA measurement. The detailed hit information (TOA and TOT) from each cell will be read out from a local circular buffer after each Level-1 Accept (about 1 MHz). In addition, a charge injection circuit is implemented to allow for testing and calibration. For more detailed monitoring of the signal pulses, waveform sampling circuits are included for one pixel. The clock distribution is based on a 16x16 H-tree design with a shielding structure to alleviate potential interference. The global peripheral circuits include a PLL, a phase shifter, an I2C slave controller, a fast control block, a global readout, and a data driver along with an efuse and temperature sensor. The ETROC builds event data frames for each L1A selected event and is also capable of providing L1 trigger information for user-defined delayed hits. The main design challenge is how to extract precision timing information from the small LGAD signals in the presence of high irradiation fluence, while keeping the power consumption and digital activity low. The ETL design goal for the time resolution of 50 ps per hit is required to achieve a 35 ps arrival time measurement for a MIP particle, which has its track registered in two ETL disk layers. The LGAD contribution is known to be about 30 ps, this means that the jitter from the ETROC has to be kept below 40 ps. The ETROC2 is the first full size full functionality prototype design fully compatible with the final chip specifications for CMS ETL and now becomes the final version. The ETROC2 chips have been extensively tested. We will present here new testing results including the bump bonding yield improvement study, the time walk correction (TWC) generality study with one pixel TWC applying to all pixels, the final SEU testing using both heavy ion and proton beam, more beam test studies including different sensors, and readiness for the ETROC2 production for CMS ETL upgrade.

Liu, Tiehui [Fermilab] (ORCID:0009000765225605)

Introducing a Markov chain-based time calibration procedure for multi-channel particle detectors: application to the SuperFGD and ToF detectors of the T2K experiment

Inter-channel mis-synchronisation can be a limiting factor to the time resolution of high performance timing detectors with multiple readout channels and independent electronics units. In these systems, time calibration methods employed must be able to efficiently correct for minimal mis-synchronisation between channels and achieve the best detector performance. We present an iterative time calibration method based on Markov Chains, suitable for detector systems with multiple readout channels. Starting from correlated hit pairs alone, and without requiring an external reference time measurement, the method solves for fixed per-channel offsets, with precision limited only by the intrinsic single-channel resolution. A mathematical proof that the method is able to find the correct time offsets to be assigned to each detector channel in order to achieve inter-channel synchronisation is given, and it is shown that the number of iterations to reach convergence within the desired precision is controllable with a single parameter. Numerical studies are used to confirm unbiased recovery of true offsets. Finally, the application of the calibration method to the Super Fine-Grained Detector (SuperFGD) and the Time of Flight (TOF) detector at the upgraded T2K near detector (ND280) shows good improvement in overall timing resolution, demonstrating the effectiveness in a real-world scenario and scalability.

calibration and fitting methods

YSO implantation detector for beta-delayed neutron spectroscopy

A segmented-scintillator-based implantation detector was developed to study the energy distribution of β-delayed neutrons emitted from exotic isotopes. The detector comprises a 34 × 34 YSO scintillator coupled to an 8 × 8 anode Position-Sensitive Photo-Multiplier Tube (PSPMT) via a tapered light guide. The detector was used at RIBF, RIKEN for time-of-flight-based neutron spectroscopy measurement in the 78Ni region. The detector provides the position and timing resolution necessary for ion-beta correlations and time of flight measurements. The detector provides a high ~80% beta-detection efficiency and a sub-nanosecond timing resolution. This contribution discusses the details of the design, operation, implementation, and analysis developed to obtain neutron time-of-flight spectrum and the analysis methods in the context of neutron-rich nuclei in the 78Ni region.

Implantation detector

A reexamination of plasma measurements from the Mariner 5 Venus encounter

Mariner 5 plasma data from the Venus encounter have been analyzed with twice the time resolution of the original analysis of Bridge et al. (1967). The velocity distribution function for each spectrum is used to determine more precisely the locations of boundaries and characteristic flow parameters in the interaction region around the planet. A new region is identified in the flow located between magnetosheathlike plasma inside the shock front and an interior low-flux region near the geometrical shadow of the planet. The region is characterized by a wide velocity distribution function and a decrease in ion flux. Using the highest time resolution magnetic field data, it is proposed that rapid magnetic field fluctuations in this region may result in an artificial broadening of the distribution function. It is concluded that very high time resolution is required in future experiments in order to determine the true nature of the plasma in this region.

Shefer, R. E.

Global Auroral Energy Deposition Derived from Polar UVI Images

Quantitative measurement of the transfer of energy and momentum to the ionosphere from the solar wind is one of the main objectives of the ISTP program. Global measurement of auroral energy deposition derived from observations of the longer wavelength LBH band emissions made by the Ultraviolet Imager on the Polar spacecraft is one of the key elements in this satellite and ground-based instrument campaign. These "measurements" are inferred by combining information from consecutive images using different filters and have a time resolution on the average of three minutes and are made continuously over a 5 to 8 hour period during each 18 hour orbit of the Polar spacecraft. The energy deposition in the ionosphere from auroral electron precipitation augments are due to Joule heating associated with field aligned currents. Assuming conjugacy of energy deposition between the two hemispheres the total energy input to the ionosphere through electron precipitation can be determined at high time resolution. Previously, precipitating particle measurements along the tracks of low altitude satellites provided only local measurements and the global energy precipitation could be inferred through models but not directly measured. We use the UVI images for the entire month of January 1997 to estimate the global energy deposition at high time resolution. We also sort the energy deposition into sectors to find possible trends, for example, on the dayside and nightside, or the dawn and dusk sides.

Fillingim, M. O.

The role of high resolution observations in determining energy release and transport processes

With present observations from the Solar Maximum Mission, we are seeing a very selective sample of spatially large flares in the soft part (10 to 50 keV) of the hard X-ray spectrum. The spatial resolution is at best 5600 km with a corresponding time resolution of 4.5 s for adequate count statistics. This resolution gives rise to the following problems: We cannot resolve the minor radii of the loops involved or tell where and how the energy release occurs. The manner in which loops interact and the relationship between the soft and hard or approx 00 keV) parts of hard X-rays remains elusive. We cannot see how energy propagates in most cases. Thus it is desirable to determine the minimum increase in spatial and temporal resolution required to solve these problems. Spatially we need to resolve the minor radius of a small loop which is about 800 km or 1 arc s. Upper limits to observed speeds of conduction fronts and shocks are approx km/s with theoretical limits running about a factor of 2 higher. Thus, a compatible minimum time resolution is in the range of 0.2 to 0.4 s. With these spatial and temporal resolutions, sufficient count statistics are required to go up to approx 120 keV with a sufficient number of energy bands to obtain spectra.

Smith, D. F.

Timing Analysis with INTEGRAL: Comparing Different Reconstruction Algorithms

INTEGRAL is one of the few instruments capable of detecting X-rays above 20keV. It is therefore in principle well suited for studying X-ray variability in this regime. Because INTEGRAL uses coded mask instruments for imaging, the reconstruction of light curves of X-ray sources is highly non-trivial. We present results from the comparison of two commonly employed algorithms, which primarily measure flux from mask deconvolution (ii-lc-extract) and from calculating the pixel illuminated fraction (ii-light). Both methods agree well for timescales above about 10 s, the highest time resolution for which image reconstruction is possible. For higher time resolution, ii-light produces meaningful results, although the overall variance of the lightcurves is not preserved.

Grinberg, V.

Skylab ATM/S-056 X-ray event analyzer: Instrument description, parameter determination, and analysis example (15 June 1973 1B/M3 flare)

The Skylab ATM/S-056 X-Ray Event Analyzer, part of an X-ray telescope experiment, is described. The techniques employed in the analysis of its data to determine electron temperatures and emission measures are reviewed. The analysis of a sample event - the 15 June 1973 1B/M3 flare - is performed. Comparison of the X-Ray Event Analyzer data with that of the SolRad 9 observations indicates that the X-Ray Event Analyzer accurately monitored the sun's 2.5 to 7.25 A X-ray emission and to a lesser extent the 6.1 to 20 A emission. A mean average peak temperature of 15 million K at 1,412 UT and a mean average peak electron density (assuming a flare volume of 10 to the 13 power cu km) of 27 million/cu mm at 1,416 to 1,417 UT are deduced for the event. The X-Ray Event Analyzer data, having a 2.5 s time resolution, should be invaluable in comparisons with other high-time resolution data (e.g., radio bursts).

Wilson, R. M.

Investigation of cosmic rays in very short time scales

A fast databuffer system, where cosmic ray events in the Turku hadron spectrometer, including particle arrival times are recorded with time resolution of 100 ns was constructed. The databuffer can be read continuously by a microprocessor, which preanalyzes the data and transfers it to the main computer. The time span, that can be analyzed in every detail, is a few seconds. The high time resolution enables a study of time correlated groups of high energy particles. In addition the operational characteristics of the spectrometer can be monitored in detail.

Peltonen, J.

Observations of the 3-D distribution of interplanetary electrons and ions from solar wind plasma to low energy cosmic rays

The 3-D Plasma and Energetic Particle instrument on the GGS Wind spacecraft (launched November 1, 1994) is designed to make measurements of the full three-dimensional distribution of suprathermal electrons and ions from solar wind plasma to low energy cosmic rays, with high sensitivity, wide dynamic range, good energy and angular resolution, and high time resolution. Three pairs of double-ended telescopes, each with two or three closely sandwiched passivated ion implanted silicon detectors measure electrons and ions from approximately 20 keV to greater than or equal to 300 keV. Four top-hat symmetrical spherical section electrostatic analyzers with microchannel plate detectors, a large and a small geometric factor analyzer for electrons and a similar pair for ions, cover from approximately 3 eV to 30 keV. We present preliminary observations of the electron and ion distributions in the absence of obvious solar impulsive events and upstream particles. The quiet time electron energy spectrum shows a smooth approximately power law fall-off extending from the halo population at a few hundred eV to well above approximately 100 keV The quiet time ion energy spectrum also shows significant fluxes over this energy range. Detailed 3-D distributions and their temporal variations will be presented.

Lin, R. P.

Enhancing the Cherenkov over scintillation ratio using dichroic filters in BGO and TlCl for TOF-PET

Abstract The Cherenkov emission in inorganic crystal scintillators has been shown to dramatically improve time resolution for time-of-flight positron emission tomography (TOF-PET) for in slow scintillators with a high refractive index such as bismuth germanium oxide (BGO). This is due to the faster nature of the Cherenkov emission (tens of picoseconds) with respect to scintillation (nanosecond). However, the presence of slower scintillation light and the inability of existing detectors to distinguish between Cherenkov and scintillation make it difficult for BGO to achieve a good CTR for all the detected coincidence events. In this paper, we exploit the difference between the Cherenkov and scintillation emission spectra and use dichroic filters to enhance the Cherenkov over scintillation ratio. Dichroic filters transmit or reflect photons based on their wavelength, with a photon attenuation lower than 10%. We investigate several shortpass and longpass dichroic filters in a single-photon configuration with BGO and find the optimal filter that maximizes the Cherenkov over scintillation ratio. We demonstrate that we can enhance the ratio of Cherenkov to scintillation photons by a factor of 2.17 ± 0.38 by employing a shortpass dichroic filter with a cut-off wavelength of 450 nm for BGO, and by a factor of 2.87 ± 0.40 using a longpass dichroic filter with a cut-on wavelength of 550 nm for iodine/beryllium-doped thallium chloride.

Science & Technology - Other Topics

X-ray and γ-ray beam interstellar communication and implications for SETI

The possibility of detecting artificial signals transmitted by alien civilizations via collimated X-ray or gamma-ray beams is investigated. The prospect of using such beams for human communication within the solar system and beyond is also discussed. Detector responses were simulated for input signals and analyzed using relative entropy. For simplicity, all signals were assumed to use on-off keying (OOK) modulation. “Real” signals were generated by taking digital files and sequentially feeding their raw binary data to the detector simulator, the resulting normalized information content of the detector signals was plotted and compared to random noise signals. Since jpeg files contain compressed information, these served as a proxy for artificial alien signals. This showed that there is a clear difference in measured information content between natural and artificial signals, even with relatively poor time resolution in the detector causing the signals to be smeared (dead-time/rise-time intervals many times longer than the duration between signal pulses). It was found that so long as the signal lasts for at least several rise-time/dead-time intervals, the distinction between random and artificial signals is obvious. A space-telescope with high time resolution for searching for such signals is briefly described and its basic requirements are outlined.

43 PARTICLE ACCELERATORS

Using quantum noise correlation analysis to measure ion temperature

Quantum noise correlation analysis was tested at the proof-of-concept level as a technique to measure ion temperature in a plasma. If eventually successful, this technique could enable a compact, inexpensive, and robust ion temperature diagnostic suitable for a burning plasma environment. Ion temperature is a key parameter determining the fusion performance of a burning plasma, as the fusion cross-section has a strong dependence on ion temperature. This ion temperature diagnostic would require only a small optical view of the plasma through a port to passively record impurity line emission. The instrumentation would be remote from the reactor behind the neutron and bio-shielding. The technique relies solely on quantum correlations of the photons emitted by a plasma impurity to measure ion temperature; there is no grating dispersion of an emission line-width or pulse-height analysis of photon energy. This measurement innovation was tested with instrumentation consisting of two single-photon detectors with high timing resolution, a time-tagging unit, and simple light collection optics. This instrumentation measures the second-order correlation between the light intensity falling on the two detectors. The next steps beyond the proof-of-concept level will be development of diagnostic designs for application of this technique to high-temperature and burning plasmas. Arrays of single-photon avalanche detectors to multiplex measurements of photon correlation will be required to reduce signal integration time to an acceptable duration.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Quadrant anode image sensor

A position-sensitive event-counting electronic readout system for microchannel plates (MCPs) is described that offers the advantages of high spatial resolution and fast time resolution. The technique relies upon a four-quadrant electron-collecting anode located behind the output face of the microchannel plate, so that the electron cloud from each detected event is partly intercepted by each of the four quadrants. The relative amounts of charge collected by each quadrant depend on event position, permitting each event to be localized with two ratio circuits. A prototype quadrant anode system for ion, electron, and extreme ultraviolet imaging is described. The spatial resolution achieved, about 10 microns, allows individual MCP channels to be distinguished.

Lampton, M.

Characteristics of cosmic X-ray bursts observed with the OGO-5 satellite

Observations of 11 cosmic X-ray bursts made with the solar X-ray spectrometer aboard OGO 5 are presented. Their identification as cosmic events is based on good time coincidence with observations of cosmic gamma-ray bursts reported in the literature. The OGO-5 experiment is most sensitive to cosmic X-ray sources located in the sunward hemisphere. When this condition was satisfied and the OGO-5 experiment was operating normally, almost every cosmic gamma-ray burst reported by other observers was detected at X-ray energies of at least 32 keV. In three events the spectrum was observed down to about 10 keV. Two intense events were observed with 0.288-s time resolution, and large time variations were observed to occur in times not exceeding 0.3 s. Evidence is found that most cosmic gamma-ray bursts have photon spectra extending down to about 10 keV. The origin of these cosmic events in processes similar to those believed to occur in solar flares is briefly examined.

Kane, S. R.

Inflight lightning characteristics measurement system

A research data-gathering system being developed for inflight measurement of direct and nearby lightning strike characteristics is described. Wideband analog recorders used to record the lightning scenario are supplemented with high-sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. The endless-loop data storage technique employed by the transient recorders circumvents problems associated with oscilloscopic techniques and allows unattended operation. System integrity and immunity from induced effects is accomplished by fiber-optics signal-transmission links, shielded system enclosures, and the use of a dynamotor for power system isolation.

Pitts, F. L.

The recognition of extraterrestrial artificial signals

Considerations in the design of receivers for the detection and recognition of artificial microwave signals of extraterrestrial origin are discussed. Following a review of the objectives of SETI and the probable reception and detection characteristics of extraterrestrial signals, means for the improvement of the sensitivity, signal-to-noise ratios and on-line data processing capabilities of SETI receivers are indicated. The characteristics of the signals likely to be present at the output of an ultra-low-noise microwave receiver are then examined, including the system background noise, terrestrial radiations, astrophysical radiations, accidental artificial radiations of terrestrial origin, and intentional radiations produced by humans and by extraterrestrial intelligence. The classes of extraterrestrial signals likely to be detected, beacons and leakage signals, are considered, and options in the specification of gating and thresholding for a high-spectral resolution, high-time-resolution signal discriminator are indicated. Possible tests for the nonhuman origin of a received signal are also pointed out.

Seeger, C. L.

Direct strike lightning measurement system

A research data system developed for in-flight measurement of direct and nearby lightning-strike characteristics is described. The measurement system consists of a wide-band analog recorder which records the continuous lightning scenario and fast sample-rate digital transient recorders with augmented memory capacity for increased time resolution of specific times of interest. Electromagnetic sensors with bandwidths exceeding 100 MHz are used which respond to rates of change of the quantities being measured. Data system immunity from electromagnetic interference is accomplished by the use of a dynamotor for power isolation, shielded system enclosure and fiber-optic data links.

Thomas, M. E.