At least 109 records · Page 6

Cryogenic monocrystalline silicon Fabry-Perot cavity for the stabilization of laser frequency

A 1.6 kg silicon monocrystal was used to make a Fabry-Perot optical cavity operated at cryogenic temperatures. High-resolution thermal expansion measurements were made as the silicon cooled to 4.2 K, in order to characterize the cavity as a length reference standard. A helium-neon laser was then locked to a transmission resonance at liquid-helium temperatures, and the laser frequency tracked the cavity resonance with error fluctuations at the level of 10 Hz/sq rt Hz in the bandwidth dc to 1 Hz. Implications of the combined set of data, thermal expansion plus frequency-tracking fluctuations, for using such a system as a frequency standard are discussed.

Richard, J.-P.↗

Frequency encoded auditory display of the critical tracking task

The use of auditory displays for selected cockpit instruments was examined. In auditory, visual, and combined auditory-visual compensatory displays of a vertical axis, critical tracking task were studied. The visual display encoded vertical error as the position of a dot on a 17.78 cm, center marked CRT. The auditory display encoded vertical error as log frequency with a six octave range; the center point at 1 kHz was marked by a 20-dB amplitude notch, one-third octave wide. Asymptotic performance on the critical tracking task was significantly better when using combined displays rather than the visual only mode. At asymptote, the combined display was slightly, but significantly, better than the visual only mode. The maximum controllable bandwidth using the auditory mode was only 60% of the maximum controllable bandwidth using the visual mode. Redundant cueing increased the rate of improvement of tracking performance, and the asymptotic performance level. This enhancement increases with the amount of redundant cueing used. This effect appears most prominent when the bandwidth of the forcing function is substantially less than the upper limit of controllability frequency.

Stevenson, J.↗

Ultrafast radiographic imaging and tracking: An overview of instruments, methods, data, and applications

Ultrafast radiographic imaging and tracking (U-RadIT) use state-of-the-art ionizing particle and light sources to experimentally study sub-nanosecond transients or dynamic processes in physics, chemistry, biology, geology, materials science and other fields. These processes are fundamental to modern technologies and applications, such as nuclear fusion energy, advanced manufacturing, communication, and green transportation, which often involve one mole or more atoms and elementary particles, and thus are challenging to compute by using the first principles of quantum physics or other forward models. One of the central problems in U-RadIT is to optimize information yield through, e.g. high-luminosity X-ray and particle sources, efficient imaging and tracking detectors, novel methods to collect data, and large-bandwidth online and offline data processing, regulated by the underlying physics, statistics, and computing power. We review and highlight recent progress in: (a.) Detectors such as high-speed complementary metal-oxide semiconductor (CMOS) cameras, hybrid pixelated array detectors integrated with Timepix4 and other application-specific integrated circuits (ASICs), and digital photon detectors; (b.) U-RadIT modalities such as dynamic phase contrast imaging, dynamic diffractive imaging, and four-dimensional (4D) particle tracking; (c.) U-RadIT data and algorithms such as neural networks and machine learning, and (d.) Applications in ultrafast dynamic material science using XFELs, synchrotrons and laser-driven sources. Hardware-centric approaches to U-RadIT optimization are constrained by detector material properties, low signal-to-noise ratio, high cost and long development cycles of critical hardware components such as ASICs. Interpretation of experimental data, including comparisons with forward models, is frequently hindered by sparse measurements, model and measurement uncertainties, and noise. Alternatively, U-RadIT make increasing use of data science and machine learning algorithms, including experimental implementations of compressed sensing. Machine learning and artificial intelligence approaches, refined by physics and materials information, may also contribute significantly to data interpretation, uncertainty quantification and U-RadIT optimization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Salathe, Marco↗

Matched pair conical spiral antennas

A matched pair of VHF (220-260 MHz) conical spiral antennas for use in a rocket-tracking interferometer array was designed and tested. While gain, bandwidth, impedance, and pattern measurements met specifications, the phase match between antennas at low elevations was not equal to the design goal.

Metzler, R. E.↗

Optimum design and performance of Costas receivers containing soft bandpass limiters

This paper investigates several key questions concerning the mechanization and design of a Costas receiver for reconstruction of a carrier from a suppressed carrier signal. For baseband NRZ encoded data symbols and a soft bandpass limiter preceding the loop, several design issues which are considered herein and which affect acquisition and tracking performance are: (1) The choice of an IF bandwidth. (2) The optimum choice of the Costas arm filter bandwidths as well as the spectral roll-off characteristics. (3) The optimum choice of loop bandwidth to data rate ratio for a given signal-to-noise ratio. (4) The signal suppression factor and the combined limiter-squaring loss. (5) The variations in loop bandwidth and damping with signal level. (6) The choice of the limiter transfer characteristic. (7) Performance degradation due to the presence of a limiter. Various new results in system design are presented and typical numerical results are given and graphically demonstrated in SNR regions of practical interest. The theory is applicable to the design of carrier reconstruction loops required in the implementation of spread spectrum communication receivers.

Lindsey, W. C.↗

Optoelectronics research for communication programs at the Goddard Space Flight Center

Current optoelectronics research and development of high-power, high-bandwidth laser transmitters, high-bandwidth, high-sensitivity optical receivers, pointing, acquisition and tracking components, and experimental and theoretical system modeling at the NASA Goddard Space Flight Center is reviewed. Program hardware and space flight milestones are presented. It is believed that these experiments will pave the way for intersatellite optical communications links for both the NASA Advanced Tracking and Data Relay Satellite System and commercial users in the 21st century.

Krainak, Michael A.↗

Intersatellite communications optoelectronics research at the Goddard Space Flight Center

A review is presented of current optoelectronics research and development at the NASA Goddard Space Flight Center for high-power, high-bandwidth laser transmitters; high-bandwidth, high-sensitivity optical receivers; pointing, acquisition, and tracking components; and experimental and theoretical system modeling at the NASA Goddard Space Flight Center. Program hardware and space flight opportunities are presented.

Krainak, Michael A.↗

Timing considerations of Helmet Mounted Display performance

The Helmet Mounted Display (HMD) system developed in our lab should be a useful teleoperator systems display if it increases operator performance of the desired task; it can, however, introduce degradation in performance due to display update rate constraints and communication delays. Display update rates are slowed by communication bandwidth and/or computational power limitations. We used simulated 3D tracking and pick-and-place tasks to characterize performance levels for a range of update rates. Initial experiments with 3D tracking indicate that performance levels plateau at an update rate between 10 and 20 Hz. We have found that using the HMD with delay decreases performance as delay increases.

Tharp, Gregory↗

A multi-modal scanning system to digitize CBRNE emergency response scenes

A handheld system developed to digitize a contextual understanding of the scene at a chemical, biological, radiological, nuclear and/or explosives (CBRNE) events is described. The system uses LiDAR and cameras to create a colorized 3D model of the environment, which helps domain experts that are supporting responders in the field. To generate the digitized model, a responder scans any suspicious objects and the surroundings by carrying the system through the scene. The scanning system provides a real-time user interface to inform the user about scanning progress and to indicate any areas that may have been missed either by the LiDAR sensors or the cameras. Currently, the collected data are post-processed on a different device, building a colorized triangular mesh of the encountered scene, with the intention of moving this pipeline to the scanner at a later point. The mesh is sufficiently compressed to be sent over a reduced bandwidth connection to a remote analyst. Furthermore, the system tracks fiducial markers attached to diagnostic equipment that is placed around the suspicious object. The resulting tracking information can be transmitted to remote analysts to further facilitate their supporting efforts. The paper will discuss the system's design, software components, the user interface used for scanning a scene, the necessary procedures for calibration of the sensors, and the processing steps of the resulting data. The discussion will close by evaluating the system's performance on 11 scenes.

Prins, Nicholas↗

Microwave link phase compensation for longitudinal stochastic cooling in RHIC

A new microwave link has been developed for the longitudinal stochastic cooling system, replacing the fiberoptic link used for the transmission of the beam signal from the pickup to the kicker. This new link reduces the pickup to kicker delay from 2/3 of a turn to 1/6 of a turn, which greatly improves the phase margin of the system and allows operation at higher frequencies. The microwave link also introduces phase modulation on the transmitted signal due to variations in the local oscillators and time of flight. A phase locked loop tracks a pilot tone generated at a frequency outside the bandwidth of the cooling system. Information from the PLL is used to calculate real-time corrections to the cooling system at a 10 kHz rate. The design of the pilot tone system is discussed and results from commissioning are described.

43 PARTICLE ACCELERATORS↗

High Momentum Transfer Nucleon Elastic Electromagnetic Form Factor Measurements Using Super BigBite Spectrometer at Jefferson Lab

The nucleons - protons and neutrons - are the basic building blocks of atomic nuclei. We now know that the nucleon consists of fundamental particles called quarks and gluons. The quarks interact with each other by exchanging gluons via the strong interaction. Understanding the quark-gluon structure of the nucleon, especially the confinement of quarks within the nucleon in its ground state, remains one of the main unsolved puzzles of particle physics. The nucleon electromagnetic form factors are directly related to the internal structure of the nucleon. A new generation of high precision experiments, GEp-V, GEn-II, GEn-RP, and GMn, measuring the ground state nucleon space-like electro-magnetic form factor at high momentum transfer is underway at Jefferson Lab experimental Hall-A as part of the Super Bigbite Spectrometer (SBS) program. This series of experiments will provide a new level of understanding of the nucleon structure. These experiments are highly demanding due to the extremely fast drop off of the elastic cross section with the increasing four-momentum transfer squared(Q2). This thesis provides an overview of the SBS physics program and reports on the extensive R&D program carried out to achieve the high rate running conditions essential for carrying out the SBS experiments. SBS will provide an intermediate solid angle of approximately 35 msr, which is significantly larger than the solid angle of other dipole based spectrometers at Jefferson lab. Of course, there are much larger acceptance spectrometers at Jefferson Lab, CLAS12 for example. What is special about SBS is that it provides a sizable acceptance while operating at the highest possible luminosity at Jefferson Lab. With this combination of medium acceptance and the highest available luminosity, SBS provides an unparalleled opportunity to explore the nucleon in its ground state with unprecedented resolution. The relatively large acceptance of SBS is achieved by using a large gap dipole magnet and placing it close to the target. An unavoidable consequence of this is that the SBS GEM trackers and other detectors have a clear line-of-sight view of the target and a portion of the beam-line. As a result, the background hit rate in the SBS front GEM trackers is expected to be up to 500 kHz/cm2, over the entire active area of 6000 cm2. To the best of our knowledge, this extremely high rate over such a large area is unprecedented in any particle tracking system used anywhere in the world before. Correctly reconstructing the particle tracks of interest in this very high background environment is achieved by using especially adapted high rate techniques at every step of the tracking process: optimizing the GEM module and tracker design at the hardware level, using high bandwidth electronics and real time Field Programmable Gate Array (FPGA) based background suppression techniques at the Data Acquisition (DAQ) level, and developing highly specialized tracking algorithms to pick out the signal hits from among the vast amount of background hits. In order to ensure a smooth start and running of the SBS experiments, it is extremely crucial that these techniques are developed, implemented, and tested under realistic conditions well before the actual start of the SBS experimental program. A detailed Geant4 simulation of the experiment was combined with a digitization package to generate the detector level pseudodata similar to what is expected in the actual experiments. The digitization procedures were calibrated against actual GEM data from cosmic-ray runs, X-ray tests, beam test runs in experimental Hall-A, and the PRad experiment in Hall B. Then, optimized tracking algorithms were developed and implemented in an analysis program used to analyze these pseudo-data and to extract expected high-level parameters. These extracted quantities were then compared with the input parameters from the simulation to verify and determine the performance characteristics for the SBS tracker. From this work, a final tracking efficiency of 69% at 25% occupancy was achieved, with the required reconstruction accuracy, for the GMn experiment, the first experiment in the SBS program, with background level at 100 kHz/cm2. These demonstrated parameters are adequate for the successful running of not only the GMn experiment but as well as for GEn-RP and GEn-II experiments, the second and third experiments in the program. This work builds the solid ground to further improve the tracking performance for these experiments and achieve similar conditions for the running of the GEp-V experiment, the most demanding experiment in the SBS program, with an expected background level at 500 kHz/cm2.

Di, Danning↗

GMSK Modulation for Deep Space Applications

Due to scarcity of spectrum at 8.42 GHz deep space Xband allocation, many deep space missions are now considering the use of higher order modulation schemes instead of the traditional binary phase shift keying (BPSK). One such scheme is pre-coded Gaussian minimum shift keying (GMSK). GMSK is an excellent candidate for deep space missions. GMSK is a constant envelope, bandwidth efficien modulation whose frame error rate (FER) performance with perfect carrier tracking and proper receiver structure is nearly identical to that of BPSK. There are several issues that need to be addressed with GMSK however. Specificall, we are interested in the combined effects of spectrum limitations and receiver structure on the coded performance of the X-band link using GMSK. The receivers that are typically used for GMSK demodulations are variations on offset quadrature phase shift keying (OQPSK) receivers. In this paper we consider three receivers: the standard DSN OQPSK receiver, DSN OQPSK receiver with filte ed input, and an optimum OQPSK receiver with filte ed input. For the DSN OQPSK receiver we show experimental results with (8920, 1/2), (8920, 1/3) and (8920, 1/6) turbo codes in terms of their error rate performance. We also consider the tracking performance of this receiver as a function of data rate, channel code and the carrier loop signal-to-noise ratio (SNR). For the other two receivers we derive theoretical results that will show that for a given loop bandwidth, a receiver structure, and a channel code, there is a lower data rate limit on the GMSK below which a higher SNR than what is required to achieve the required FER on the link is needed. These limits stem from the minimum loop signal-to-noise ratio requirements on the receivers for achieving lock. As a result of this, for a given channel code and a given FER, there could be a gap between the maximum data rate that BPSK can support without violating the spectrum limits and the minimum data rate that GMSK can support with the required FER depending on the type of GMSK receiver that is used.

Communications↗

Wideband heterodyne receiver for laser communication system

A heterodyne receiver for laser communication is described which includes a front end having a cooled photomixer contained in a hermetically sealed spaced quality housing designed for wide bandwidth transmission. The photomixer is coupled through a wideband preamplifier to the receiver back end which includes a frequency tracking network and demodulating equipment. The receiver is capable of tracking a Doppler frequency shift of 750 MHz, positive or negative, and has an instantaneous intermediate frequency information bandwidth of 400 MHz. The receiver system is also capable of operating over a wide temperature range and is designed to be suitable for use in outer space communication.

Flattau, T.↗

An initial assessment of the performance achieved by the Seasat-1 radar altimeter

The results of an initial on-orbit engineering assessment of the performance achieved by the radar altimeter system flown on SEASAT-1 are presented. Additionally, the general design characteristics of this system are discussed and illustrations of altimeter data product are provided. The instrument consists of a 13.5 GHz monostatic radar system that tracks in range only using a one meter parabolic antenna pointed at the satellite nadir. Two of its unique features are a linear FM transmitter with 320 MHz bandwidth which yields a 3.125 nanosecond time delay resolution, and microprocessor implemented closed loop range tracking, automatic gain control (AGC), and real time estimation of significant wave height (SWH). Results presented show that the altimeter generally performed in accordance with its orginal performance requirments of measuring altitude to a precision of less the 10 cm RMS, significant wave height to an accuracy of + or - 0.5 m or 10%, whichever is greater, and ocean backscatter coefficient to an accuracy of + or - 1 db, all over an SWH range of 1 to 20 meters.

Townsend, W. F.↗

A Microstrip Patch-Fed Short Backfire Antenna for the Tracking and Data Relay Satellite System-Continuation (TDRSS-C) Multiple Access (MA) Array

Short Backfire Antennas (SBAs) are widely utilized for mobile satellite communications, tracking, telemetry, and wireless local area network (WLAN) applications due to their compact structure and excellent radiation characteristics [1-3]. Typically, these SBA s consist of an excitation element (i.e., a half-wavelength dipole), a reflective bottom plane, a planar sub-reflector located above the "exciter", and an outer circular rim. This configuration is capable of achieving gains on the order of 13-15 dBi, but with relatively narrow bandwidths (approx.3%-5%), making it incompatible with the requirements of the next generation enhanced Tracking and Data Relay Satellite System-Continuation (TDRSS-C) Multiple Access (MA) array [1]. Several attempts have been made to enhance the bandwidth performance of the common dipole-fed SBA by employing various other feeding mechanisms (e.g., waveguide, slot) with moderate success [4-5]. In this paper, a novel method of using a microstrip patch is employed for the first time to excite an SBA. The patch element is fed via two H-shaped slots electromagnetically coupled to a broadband hybrid coupler to maintain a wide bandwidth, as well as provide for dual circular polarization capabilities.

Nessel, James A.↗

An analysis of carrier phase jitter in an MPSK receiver utilizing map estimation

The use of 8 and 16 PSK TCM to support satellite communications in an effort to achieve more bandwidth efficiency in a power-limited channel has been proposed. This project addresses the problem of carrier phase jitter in an M-PSK receiver utilizing the high SNR approximation to the maximum aposteriori estimation of carrier phase. In particular, numerical solutions to the 8 and 16 PSK self-noise and phase detector gain in the carrier tracking loop are presented. The effect of changing SNR on the loop noise bandwidth is also discussed. These data are then used to compute variance of phase error as a function of SNR. Simulation and hardware data are used to verify these calculations. The results show that there is a threshold in the variance of phase error versus SNR curves that is a strong function of SNR and a weak function of loop bandwidth. The M-PSK variance thresholds occur at SNR's in the range of practical interest for the use of 8 and 16-PSK TCM. This suggests that phase error variance is an important consideration in the design of these systems.

Osborne, William P.↗

An initial assessment of the performance achieved by the Seasat-1 radar altimeter

This paper describes the results of an initial on-orbit engineering assessment of the performance achieved by the radar altimeter system flown on Seasat-1. Additionally, the general design characteristics of this system are discussed and illustrations of altimeter data products are provided. The instrument consists of a 13.5-GHz monostatic radar system that tracks in range only using a 1-m parabolic antenna pointed at the satellite nadir. Two of its unique features are a linear FM transmitter with 320-MHz bandwidth, which yields a 3.125-ns time-delay resolution, and microprocessor-implemented closed-loop range tracking, automatic gain control (AGC), and real-time estimation of significant wave height (SWH). Results presented herein show that the altimeter generally performed in accordance with its original performance requirements of measuring altitude to a precision of less than 10-cm rms, SWH to an accuracy of plus or minus 0.5 m or 10 percent whichever is greater, and ocean backscatter coefficient to an accuracy of plus or minus 1 dB, all over an SWH range of 1 to 20 m.

Townsend, W. F.↗