Search NASA⌕ Search

SEARCH · Search NASA

Results for “Tracking error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

TH-AB-202-04: Auto-Adaptive Margin Generation for MLC-Tracked Radiotherapy

Purpose: To develop an auto-adaptive margin generator for MLC tracking. The generator is able to estimate errors arising in image guided radiotherapy, particularly on an MR-Linac, which depend on the latencies of machine and image processing, as well as on patient motion characteristics. From the estimated error distribution, a segment margin is generated, able to compensate errors up to a user-defined confidence. Method: In every tracking control cycle (TCC, 40ms), the desired aperture D(t) is compared to the actual aperture A(t), a delayed and imperfect representation of D(t). Thus an error e(t)=A(T)-D(T) is measured every TCC. Applying kernel-density-estimation (KDE), the cumulative distribution (CDF) of e(t) is estimated. With CDF-confidence limits, upper and lower error limits are extracted for motion axes along and perpendicular leaf-travel direction and applied as margins. To test the dosimetric impact, two representative motion traces were extracted from fast liver-MRI (10Hz). The traces were applied onto a 4D-motion platform and continuously tracked by an Elekta Agility 160 MLC using an artificially imposed tracking delay. Gafchromic film was used to detect dose exposition for static, tracked, and error-compensated tracking cases. The margin generator was parameterized to cover 90% of all tracking errors. Dosimetric impact was rated by calculating the ratio between underexposed points (>5% underdosage) to the total number of points inside FWHM of static exposure. Results: Without imposing adaptive margins, tracking experiments showed a ratio of underexposed points of 17.5% and 14.3% for two motion cases with imaging delays of 200ms and 300ms, respectively. Activating the margin generated yielded total suppression (<1%) of underdosed points. Conclusion: We showed that auto-adaptive error compensation using machine error statistics is possible for MLC tracking. The error compensation margins are calculated on-line, without the need of assuming motion or machine models. Further strategies to reduce consequential overdosages are currently under investigation. This work was funded by the SoRTS consortium, which includes the industry partners Elekta, Philips and Technolution.

60 APPLIED LIFE SCIENCES↗

Compensation of Axis Errors of Azimuth and Zenith Moving Concentrators in Programmable Solar-Tracking Systems

The solar-energy industry is currently concerned with improving software systems of sun-tracking concentrators. It is a feature of programmable tracking that there is no feedback from the tracked object, unlike in the case of optical tracking. In this regard, the accuracy of programmable tracking is affected by a large number of factors—in particular, axis-alignment errors. An error-checking algorithm is considered for the azimuth and zenith concentrator axes in programmable sun tracking. Effects of these errors on the accuracy of programmable tracking are assessed. It is shown that zenith axis errors have the same amount of influence as the vertical deviation of the azimuth axis, primarily affecting the azimuth angle, while its influence on the solar elevation can be neglected. The cumulative effect of axial errors is most noticeable when they have the same signs and lie in the same plane.

14 SOLAR ENERGY↗

High throughput automated characterization of enamel microstructure using synchrotron tomography and optical flow imaging

The remarkable damage-tolerance of enamel has been attributed to its hierarchical microstructure and the organized bands of decussated rods. A thorough characterization of the microscale rod evolution within the enamel is needed to elucidate this complex structure. While prior efforts in this area have made use of single particle tracking to track a single rod evolution to various degrees of success, such a process can be both computationally and labor intensive, limited to the evolution path of a single rod, and is therefore prone to error from potentially tracking outliers. Particle image velocimetry (PIV) is a well-established algorithm to derive field information from image sequences for processes that are time-dependent, such as fluid flows and structural deformation. In this work, we demonstrate the use of PIV in extracting the full-field microstructural distribution of rods within the enamel. Further, enamel samples from a wild African lion were analyzed using high-energy synchrotron X-ray micro-tomography. Results from the PIV analysis provide sufficient full-field information to reconstruct the growth of individual rods that can potentially enable rapid analysis of complex microstructures from high resolution synchrotron datasets. Such information can serve as a template for designing damage-tolerant bioinspired structures for advanced manufacturing.

36 MATERIALS SCIENCE↗

Optimizing injection for the storage ring proton-EDM experiment

The proposed proton electric dipole moment (pEDM) experiment at Brookhaven National Laboratory (BNL), to be built inside the alternating gradient synchrotron (AGS) tunnel, aims to measure the proton’s electric dipole moment with a sensitivity of 10 −29 𝑒 cm. This paper presents the design of the injection line from the AGS booster to the pEDM storage ring, utilizing portions of the existing booster-to-AGS (BtA) transfer line. Building on the symmetric-hybrid lattice design [, Comprehensive symmetric-hybrid ring design for a proton-EDM experiment at below 10 −29 𝑒 cm, Phys. Rev. D 105, 032001 (2022)], our study emphasizes rigorous optics matching, detailed particle and spin tracking, and systematic error mitigation essential for achieving a target sensitivity of 10 −29 𝑒 cm. This design preserves the proton’s vertical spin orientation within ±20 mrad, a critical requirement for the pEDM measurement. Particle and spin tracking simulations using the ray-tracing code Zgoubi [F. Méot, Zgoubi users’ guide, Technical Report, Brookhaven National Laboratory (BNL), Relativistic Heavy Ion Collider (RHIC), Upton, NY, 2012] validate the design’s performance, demonstrating its feasibility for this precision experiment. The simulation results demonstrate that both clockwise (CW) and counterclockwise (CCW) injection lines meet the stringent beam envelope and polarization requirements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Correlation and 3D-tracking of objects by pointing sensors

A method and system for tracking at least one object using a plurality of pointing sensors and a tracking system are disclosed herein. In a general embodiment, the tracking system is configured to receive a series of observation data relative to the at least one object over a time base for each of the plurality of pointing sensors. The observation data may include sensor position data, pointing vector data and observation error data. The tracking system may further determine a triangulation point using a magnitude of a shortest line connecting a line of sight value from each of the series of observation data from each of the plurality of sensors to the at least one object, and perform correlation processing on the observation data and triangulation point to determine if at least two of the plurality of sensors are tracking the same object. Observation data may also be branched, associated and pruned using new incoming observation data.

47 OTHER INSTRUMENTATION↗

Coincidence Anticipation Timing Responses with Head Tracking and Eye Tracking

Head tracking movements are common in interceptive tasks. The benefits of these movements are unclear. The purpose of this study was to compare coincidence anticipation timing (CAT) responses for a simulated approaching object when the eyes were used in tracking the object and when the head was used in tracking the object.A total of 29 subjects participated. A Bassin Anticipation Timer consisting of a track of sequentially illuminated lights was used to simulate an approaching object at velocities of 223 cm · s -1 to 894 cm · s -1 . Each velocity was used 10 times under 2 conditions. In one condition, subjects were told to turn the eyes with the stimulus. In the other condition, subjects viewed the stimulus through apertures and were told to turn the head with the stimulus. Subjects pushed a button to coincide with illumination of the final light on the track. Signed CAT errors, unsigned CAT errors, and variable CAT errors were compared between the head movement (HM) and eye movement (EM) conditions. No significant differences were noted for the signed errors (mean signed error at 894 cm · s -1 ; 10.3 ± 75.4 ms (HM), -16.1 ± 51.0 ms (EM). However, the unsigned and variable errors were significantly larger at some stimulus velocities in the head movement condition [mean unsigned error at 894 cm · s -1 : 82.6.0 ± 45.9 ms (HM), 59.0 ± 22.4 ms (EM); mean variable error at 894 cm · s -1 ; 78.0 ± 37.8 ms (HM), 49.2 ± 17.1ms (EM)]. DISCUSSION: Head movement did not result in improved CAT performance compared to eye movements. Further work will be required to determine whether these results are generalizable to situations where head tracking is required but apertures are not worn.

Biophysics↗

Quantification of Intrafraction and Interfraction Tumor Motion Amplitude and Prediction Error for Different Liver Tumor Trajectories in Cyberknife Synchrony Tracking

To research the fiducial-based, real-time tracking intrafraction (during the fraction [intra-]) and interfraction (between fractions [inter-]) tumor respiration amplitude, motion trajectory, and prediction error and quantify their relationships for different types of motion trajectories during Cyberknife-based stereotactic ablation radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characterizing spatiotemporal information loss in sparse-sampling-based dynamic MRI for monitoring respiration-induced tumor motion in radiotherapy

Purpose: Sparse-sampling and reconstruction techniques represent an attractive strategy to achieve faster image acquisition speeds, while maintaining adequate spatial resolution and signal-to-noise ratio in rapid magnetic resonance imaging (MRI). The authors investigate the use of one such sequence, broad-use linear acquisition speed-up technique (k-t BLAST) in monitoring tumor motion for thoracic and abdominal radiotherapy and examine the potential trade-off between increased sparsification (to increase imaging speed) and the potential loss of “true” information due to greater reliance on a priori information. Methods: Lung tumor motion trajectories in the superior–inferior direction, previously recorded from ten lung cancer patients, were replayed using a motion phantom module driven by an MRI-compatible motion platform. Eppendorf test tubes filled with water which serve as fiducial markers were placed in the phantom. The modeled rigid and deformable motions were collected in a coronal image slice using balanced fast field echo in conjunction with k-t BLAST. Root mean square (RMS) error was used as a metric of spatial accuracy as measured trajectories were compared to input data. The loss of spatial information was characterized for progressively increasing acceleration factor from 1 to 16; the resultant sampling frequency was increased approximately from 2.5 to 19 Hz when the principal direction of the motion was set along frequency encoding direction. In addition to the phantom study, respiration-induced tumor motions were captured from two patients (kidney tumor and lung tumor) at 13 Hz over 49 s to demonstrate the impact of high speed motion monitoring over multiple breathing cycles. For each subject, the authors compared the tumor centroid trajectory as well as the deformable motion during free breathing. Results: In the rigid and deformable phantom studies, the RMS error of target tracking at the acquisition speed of 19 Hz was approximately 0.3–0.4 mm, which was smaller than the reconstructed pixel resolution of 0.67 mm. In the patient study, the dynamic 2D MRI enabled the monitoring of cycle-to-cycle respiratory variability present in the tumor position. It was seen that the range of centroid motion as well as the area covered due to target motion during each individual respiratory cycle was underestimated compared to the entire motion range observed over multiple breathing cycles. Conclusions: The authors’ initial results demonstrate that sparse-sampling- and reconstruction-based dynamic MRI can be used to achieve adequate image acquisition speeds without significant information loss for the task of radiotherapy guidance. Such monitoring can yield spatial and temporal information superior to conventional offline and online motion capture methods used in thoracic and abdominal radiotherapy.

60 APPLIED LIFE SCIENCES↗

GANpiler

Focal Area(s): Rather than augment or replace physical models with machine learning, we instead preserve the existing models and augment the underlying code with faster surrogate models created by generative adversarial networks (GAN). To leverage the performance optimization, we also propose a runtime system and user interfaces that allow prediction and tracking of accumulated error as well as dynamic, per-process decision making as to which model (if any) to use for each iteration. Science Challenge: This proposal sits at the nexus of two hard problems. First, climate models based on machine learning will be, by their nature, difficult to trust once their predictions begin diverging from the consensus. Second, compilers and hardware have been making only incremental performance gains for decades. GPGPUs have provided a welcome performance boost for codes that can take advantage of them, but there is no similar technology on the horizon to provide the next performance leap.

54 ENVIRONMENTAL SCIENCES↗

Polarimetry-Enhanced Imaging towards Autonomous Solar Field and Receiver Inspections

During the typical operation of a Concentrating Solar Power (CSP) plant, a large portion of the energy (~45%) can be lost due to various imperfect conditions, such as blocking, shading, mirror soiling, tracking and canting errors, etc. It is necessary to develop efficient and effective field inspection technology to optically survey and characterize a CSP field, which can be used as an input for autonomous control, maintenance scheduling and spot repair whenever necessary to maximize the overall efficiency of the plant. In this project, We aim to apply polarimetric imaging for CSP collector and receiver inspection and develop polarimetric drone cameras (via integrating polarimetric imagers onto drones) for autonomous field inspection in CSP plants.

14 SOLAR ENERGY↗

SU-G-BRA-10: Marker Free Lung Tumor Motion Tracking by An Active Contour Model On Cone Beam CT Projections for Stereotactic Body Radiation Therapy of Lung Cancer

Purpose: To develop a novel strategy to extract the lung tumor motion from cone beam CT (CBCT) projections by an active contour model with interpolated respiration learned from diaphragm motion. Methods: Tumor tracking on CBCT projections was accomplished with the templates derived from planning CT (pCT). There are three major steps in the proposed algorithm: 1) The pCT was modified to form two CT sets: a tumor removed pCT and a tumor only pCT, the respective digitally reconstructed radiographs DRRtr and DRRto following the same geometry of the CBCT projections were generated correspondingly. 2) The DRRtr was rigidly registered with the CBCT projections on the frame-by-frame basis. Difference images between CBCT projections and the registered DRRtr were generated where the tumor visibility was appreciably enhanced. 3) An active contour method was applied to track the tumor motion on the tumor enhanced projections with DRRto as templates to initialize the tumor tracking while the respiratory motion was compensated for by interpolating the diaphragm motion estimated by our novel constrained linear regression approach. CBCT and pCT from five patients undergoing stereotactic body radiotherapy were included in addition to scans from a Quasar phantom programmed with known motion. Manual tumor tracking was performed on CBCT projections and was compared to the automatic tracking to evaluate the algorithm accuracy. Results: The phantom study showed that the error between the automatic tracking and the ground truth was within 0.2mm. For the patients the discrepancy between the calculation and the manual tracking was between 1.4 and 2.2 mm depending on the location and shape of the lung tumor. Similar patterns were observed in the frequency domain. Conclusion: The new algorithm demonstrated the feasibility to track the lung tumor from noisy CBCT projections, providing a potential solution to better motion management for lung radiation therapy.

60 APPLIED LIFE SCIENCES↗

Improvements in Reflected Target Non-intrusive Assessment (ReTNA)

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. In 2022, NREL presented a new indoor optical measurement system to measure fully assembled heliostats during development and on the assembly line for quality assurance purposes, which has undergone significant development in the last year, including the installation of a new, larger laboratory setup. This system, called ReTNA (Reflected Target Non-intrusive Assessment), uses a printed pattern as a deflectometry target. Using printed pattern features as deflectometry targets instead of fringes allows the software to measure the surface slope in two dimensions, eliminating the need to for changing, projected targets. In the last year, NREL's ReTNA tool has been adapted to use a tall, thin target, that only spans one dimension of the mirror, and a camera moving on an automatic track system. We will present these new developments, including the new setup, target patterns, software methodology for fast, automatic optical analysis, and important lessons learned throughout the process. ReTNA results will be compared to established tools, to establish the uncertainty of this new method. ReTNA leverages recent improvements in computer vision and photogrammetry to remove as much careful calibration from the setup process as possible, making the tool low cost, simple, and portable. While it will not achieve the resolution of a fringe deflectometry system, its advantages make it well suited for CSP evaluation, and allow it to fill a different industry need.

concentrating solar power↗

Computer-Vision-Based Vibration Tracking Using a Digital Camera: A Sparse-Optical-Flow-Based Target Tracking Method

Computer-vision-based target tracking is a technology applied to a wide range of research areas, including structural vibration monitoring. However, current target tracking methods suffer from noise in digital image processing. In this paper, a new target tracking method based on the sparse optical flow technique is introduced for improving the accuracy in tracking the target, especially when the target has a large displacement. The proposed method utilizes the Oriented FAST and Rotated BRIEF (ORB) technique which is based on FAST (Features from Accelerated Segment Test), a feature detector, and BRIEF (Binary Robust Independent Elementary Features), a binary descriptor. ORB maintains a variety of keypoints and combines the multi-level strategy with an optical flow algorithm to search the keypoints with a large motion vector for tracking. Then, an outlier removal method based on Hamming distance and interquartile range (IQR) score is introduced to minimize the error. The proposed target tracking method is verified through a lab experiment—a three-story shear building structure subjected to various harmonic excitations. It is compared with existing sparse-optical-flow-based target tracking methods and target tracking methods based on three other types of techniques, i.e., feature matching, dense optical flow, and template matching. The results show that the performance of target tracking is greatly improved through the use of a multi-level strategy and the proposed outlier removal method. The proposed sparse-optical-flow-based target tracking method achieves the best accuracy compared to other existing target tracking methods.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration and Automation of Reflected Target Optical Measurement for Heliostats

Accurate optical surfaces are a primary driver of concentrated solar power plant performance. Errors in pointing and tracking mirrors, the canting of individual mirror facets, and the surface slope of the mirror itself can be caused by errors during assembly, transportation, wind loading, gravity, and many other sources. The tools that exist to measure these error sources today largely rely on fringe deflectometry (SOFAST, QDec, others), or photogrammetry with targets attached to the mirror surface. Since 2022, NREL has been developing a measurement method called the Reflected Target Non-intrusive Assessment (ReTNA) system. This system differs from most established methods in that we perform deflectometry with a pattern of coded targets, identified in space with photogrammetry. Reflected target systems have several advantages over traditional fringe deflectometry systems. Firstly, they can be operated in bright or ambient lighting, a challenge for fringe systems that use a projector and screen. Reflected target systems also can use a much lighter and less expensive target than projector-based systems. Lastly, 2D slope measurement can be solved from a single image, which leads to several advantages for accommodating faster measurements and smaller sized targets. These advantages make ReTNA particularly well-suited for applications where there are space or lighting constraints, like performing heliostat quality assurance on an assembly line. It's also useful when a lightweight, flexible system is needed, like for heliostat developers to quickly measure a new heliostat design at different orientations, to observe gravitational effects on the mirror surface shape. In the last year, significant improvements were made to this tool to make it more useful for these applications. These improvements were focused around validation of the ReTNA measurement system, and automation of the setup and measurement process. First, we present an improved ReTNA layout, for use on the heliostat assembly line. Next, we detail the various changes to the ReTNA software and computer vision methods to automate data collection in this new setup, and lessons learned from this process. The goal with this new setup is to perform a full heliostat surface characterization without removing the mirror from the assembly line. Lastly, we share results from several ReTNA validation studies undertaken over the last year. These include repeated ReTNA measurement on demonstration mirror facets, comparisons with other optical measurement tools, and some studies aimed at quantifying the uncertainty of ReTNA measurement under various constraints (mirror-target spacing, camera resolution, etc.). These results are compared with 2024 HelioCon performance targets, and our planned next steps for the ReTNA measurement system are presented.

CSP↗

MO-AB-BRA-09: Development and Evaluation of a Biomechanical Modeling-Assisted CBCT Reconstruction Technique (Bio-Recon)

Purpose: To develop a Bio-recon technique by incorporating the biomechanical properties of anatomical structures into the deformation-based CBCT reconstruction process. Methods: Bio-recon reconstructs the CBCT by deforming a prior high-quality CT/CBCT using a deformation-vector-field (DVF). The DVF is solved through two alternating steps: 2D–3D deformation and finite-element-analysis based biomechanical modeling. 2D–3D deformation optimizes the DVF through an ‘intensity-driven’ approach, which updates the DVF to minimize intensity mismatches between the acquired projections and the simulated projections from the deformed CBCT. In contrast, biomechanical modeling optimizes the DVF through a ‘biomechanical-feature-driven’ approach, which updates the DVF based on the biophysical properties of anatomical structures. In general, Biorecon extracts the 2D–3D deformation-optimized DVF at high-contrast structure boundaries, and uses it as the boundary condition to drive biomechanical modeling to optimize the overall DVF, especially at low-contrast regions. The optimized DVF is fed back into the 2D–3D deformation for further optimization, which forms an iterative loop. The efficacy of Bio-recon was evaluated on 11 lung patient cases, each with a prior CT and a new CT. Cone-beam projections were generated from the new CTs to reconstruct CBCTs, which were compared with the original new CTs for evaluation. 872 anatomical landmarks were also manually identified by a clinician on both the prior and new CTs to track the lung motion, which was used to evaluate the DVF accuracy. Results: Using 10 projections for reconstruction, the average (± s.d.) relative errors of reconstructed CBCTs by the clinical FDK technique, the 2D–3D deformation-only technique and Bio-recon were 46.5±5.9%, 12.0±2.3% and 10.4±1.3%, respectively. The average residual errors of DVF-tracked landmark motion by the 2D–3D deformation-only technique and Bio-recon were 5.6±4.3mm and 3.1±2.4mm, respectively. Conclusion: Bio-recon improved accuracy for both the reconstructed CBCT and the DVF. The accurate DVF can benefit multiple clinical practices, such as image-guided adaptive radiotherapy. We acknowledge funding support from the American Cancer Society (RSG-13-326-01-CCE), from the US National Institutes of Health (R01 EB020366), and from the Cancer Prevention and Research Institute of Texas (RP130109).

60 APPLIED LIFE SCIENCES↗

Performance Tradeoffs of Spectrum Sensing and Target State Estimation and Fusion

We consider a scenario where a cognitive radio sensor performs spectrum sensing and target tracking alternately. Both tasks may impose certain performance guarantee requirements that necessitate considerations of how to schedule these tasks over time. In addition, multiple such cognitive radio sensors can perform collaborative spectrum sensing and target tracking, where a fusion center serves to collect the sensor estimates and their covariances to generate fused target state estimates. We study the performance tradeoffs of these two tasks from variable scheduling intervals. The effect of sensing errors on the target tracking performance due to induced loss from perceived channel unavailability is investigated and conclusions are drawn based on the observed performance tradeoffs.

Liu, Qiang↗

Ensemble‐Based Assimilation of Satellite All‐Sky Microwave Radiances Improves Intensity and Rainfall Predictions for Hurricane Harvey (2017)

Abstract Ensemble‐based data assimilation of radar observations across inner‐core regions of tropical cyclones (TCs) in tandem with satellite all‐sky infrared (IR) radiances across the TC domain improves TC track and intensity forecasts. This study further investigates potential enhancements in TC track, intensity, and rainfall forecasts via assimilation of all‐sky microwave (MW) radiances using Hurricane Harvey (2017) as an example. Assimilating Global Precipitation Measurement constellation all‐sky MW radiances in addition to GOES‐16 all‐sky IR radiances reduces the forecast errors in the TC track, rapid intensification (RI), and peak intensity compared to assimilating all‐sky IR radiances alone, including a 24‐hr increase in forecast lead‐time for RI. Assimilating all‐sky MW radiances also improves Harvey's hydrometeor fields, which leads to improved forecasts of rainfall after Harvey's landfall. This study indicates that avenues exist for producing more accurate forecasts for TCs using available yet underutilized data, leading to better warnings of and preparedness for TC‐associated hazards in the future.

54 ENVIRONMENTAL SCIENCES↗

SU-G-BRA-12: Development of An Intra-Fractional Motion Tracking and Dose Reconstruction System for Adaptive Stereotactic Body Radiation Therapy in High-Risk Prostate Cancer

Purpose: A clinical trial on stereotactic body radiation therapy (SBRT) for high-risk prostate cancer is undergoing at our institution. In addition to escalating dose to the prostate, we have increased dose to intra-prostatic lesions. Intra-fractional prostate motion deteriorates well planned radiation dose, especially for the small intra-prostatic lesions. To solve this problem, we have developed a motion tracking and 4D dose-reconstruction system to facilitate adaptive re-planning. Methods: Patients in the clinical trial were treated with VMAT using four arcs and 10 FFF beam. KV triggered x-ray projections were taken every 3 sec during delivery to acquire 2D projections of 3D anatomy at the direction orthogonal to the therapeutic beam. Each patient had three implanted prostate markers. Our developed system first determined 2D projection locations of these markers and then 3D prostate translation and rotation via 2D/3D registration of the markers. Using delivery log files, our GPU-based Monte Carlo tool (goMC) reconstructed dose corresponding to each triggered image. The calculated 4D dose distributions were further aggregated to yield the delivered dose. Results: We first tested each module in our system. MC dose engine were commissioned to our treatment planning system with dose difference of <0.5%. For motion tracking, 1789 kV projections from 7 patients were acquired. The 2D marker location error was <1 mm. For 3D motion tracking, root mean square (RMS) errors along LR, AP, and CC directions were 0.26mm, 0.36mm, and 0.01mm respectively in simulation studies and 1.99mm, 1.37mm, and 0.22mm in phantom studies. We also tested the entire system workflow. Our system was able to reconstruct delivered dose. Conclusion: We have developed a functional intra-fractional motion tracking and 4D dose re-construction system to support our clinical trial on adaptive high-risk prostate cancer SBRT. Comprehensive evaluations have shown the capability and accuracy of our system.

60 APPLIED LIFE SCIENCES↗