Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trajectory Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ultrabroadband flying-focus using an axiparabola-echelon pair

Flying-focus pulses promise to revolutionize laser-driven secondary sources by decoupling the trajectory of the peak intensity from the native group velocity of the medium over distances much longer than a Rayleigh range. Previous demonstrations of the flying focus have either produced an uncontrolled trajectory or a trajectory that is engineered using chromatic methods that limit the duration of the peak intensity to picosecond scales. Here we demonstrate a controllable ultrabroadband flying focus using a nearly achromatic axiparabola-echelon pair. Spectral interferometry using an ultrabroadband superluminescent diode was used to measure designed super- and subluminal flying-focus trajectories and the effective temporal pulse duration as inferred from the measured spectral phase. The measurements demonstrate that a nearly transform- and diffraction-limited moving focus can be created over a centimeter-scale—an extended focal region more than 50 Rayleigh ranges in length. This ultrabroadband flying-focus and the novel axiparabola-echelon configuration used to produce it are ideally suited for applications and scalable to >100 TW peak powers.

47 OTHER INSTRUMENTATION↗

Automated experimental design of safe rampdowns via probabilistic machine learning

Abstract Typically the rampdown phase of a shot consists of a decrease in current and injected power and optionally a change in shape, but there is considerable flexibility in the rate, sequencing, and duration of these changes. On the next generation of tokamaks it is essential that this is done safely as the device could be damaged by the stored thermal and electromagnetic energy present in the plasma. This works presents a procedure for automatically choosing experimental rampdown designs to rapidly converge to an effective rampdown trajectory. This procedure uses probabilistic machine learning methods paired with acquisition functions taken from Bayesian optimization. In a set of 2022 experiments at DIII-D, the rampdown designs produced by our method maintained plasma control down to substantially lower current and energy levels than are typically observed. The actions predicted by the model significantly improved as the model was able to explore over the course of the experimental campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Interpolating moving least-squares methods for fitting potential energy surfaces : using classical trajectories to explore configuration space.

We develop two approaches for growing a fitted potential energy surface (PES) by the interpolating moving least-squares (IMLS) technique using classical trajectories. We illustrate both approaches by calculating nitrous acid (HONO) cis {yields} trans isomerization trajectories under the control of ab initio forces from low-level HF/cc-pVDZ electronic structure calculations. In this illustrative example, as few as 300 ab initio energy/gradient calculations are required to converge the isomerization rate constant at a fixed energy to {approx}10%. Neither approach requires any preliminary electronic structure calculations or initial approximate representation of the PES (beyond information required for trajectory initial conditions). Hessians are not required. Both approaches rely on the fitting error estimation properties of IMLS fits. The first approach, called IMLS-accelerated direct dynamics, propagates individual trajectories directly with no preliminary exploratory trajectories. The PES is grown 'on the fly' with the computation of new ab initio data only when a fitting error estimate exceeds a prescribed tight tolerance. The second approach, called dynamics-driven IMLS fitting, uses relatively inexpensive exploratory trajectories to both determine and fit the dynamically accessible configuration space. Once exploratory trajectories no longer find configurations with fitting error estimates higher than the designated accuracy, the IMLS fit is considered to be complete and usable in classical trajectory calculations or other applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Data Intensive Analysis of Biomolecular Simulations

The advances in biomolecular modeling and simulation made possible by the availability of increasingly powerful high performance computing resources is extending molecular simulations to biological more relevant system size and time scales. At the same time, advances in simulation methodologies are allowing more complex processes to be described more accurately. These developments make a systems approach to computational structural biology feasible, but this will require a focused emphasis on the comparative analysis of the increasing number of molecular simulations that are being carried out for biomolecular systems with more realistic models, multi-component environments, and for longer simulation times. Just as in the case of the analysis of the large data sources created by the new high-throughput experimental technologies, biomolecular computer simulations contribute to the progress in biology through comparative analysis. The continuing increase in available protein structures allows the comparative analysis of the role of structure and conformational flexibility in protein function, and is the foundation of the discipline of structural bioinformatics. This creates the opportunity to derive general findings from the comparative analysis of molecular dynamics simulations of a wide range of proteins, protein-protein complexes and other complex biological systems. Because of the importance of protein conformational dynamics for protein function, it is essential that the analysis of molecular trajectories is carried out using a novel, more integrative and systematic approach. We are developing a much needed rigorous computer science based framework for the efficient analysis of the increasingly large data sets resulting from molecular simulations. Such a suite of capabilities will also provide the required tools for access and analysis of a distributed library of generated trajectories. Our research is focusing on the following areas: (1) the development of an efficient analysis framework for very large scale trajectories on massively parallel architectures, (2) the development of novel methodologies that allow automated detection of events in these very large data sets, and (3) the efficient comparative analysis of multiple trajectories. The goal of the presented work is the development of new algorithms that will allow biomolecular simulation studies to become an integral tool to address the challenges of post-genomic biological research. The strategy to deliver the required data intensive computing applications that can effectively deal with the volume of simulation data that will become available is based on taking advantage of the capabilities offered by the use of large globally addressable memory architectures. The first requirement is the design of a flexible underlying data structure for single large trajectories that will form an adaptable framework for a wide range of analysis capabilities. The typical approach to trajectory analysis is to sequentially process trajectories time frame by time frame. This is the implementation found in molecular simulation codes such as NWChem, and has been designed in this way to be able to run on workstation computers and other architectures with an aggregate amount of memory that would not allow entire trajectories to be held in core. The consequence of this approach is an I/O dominated solution that scales very poorly on parallel machines. We are currently using an approach of developing tools specifically intended for use on large scale machines with sufficient main memory that entire trajectories can be held in core. This greatly reduces the cost of I/O as trajectories are read only once during the analysis. In our current Data Intensive Analysis (DIANA) implementation, each processor determines and skips to the entry within the trajectory that typically will be available in multiple files and independently from all other processors read the appropriate frames.

59 BASIC BIOLOGICAL SCIENCES↗

Equal energy phase space trajectories in resonant wave interactions

Adiabatic evolution of two and three resonantly interacting wave systems with nonlinear frequency/wave vector shifts is discussed. The corresponding Hamiltonian, depending on the coupling, detuning, and nonlinear frequency shift parameters may have a variable number of fixed points, i.e., the system can experience a topological change of phase space when these parameters vary in time or space. It is shown that the oscillation periods of two equal energy trajectories in these wave systems are equal and the difference between the action integrals of such trajectories is obtained analytically as a function of the system parameters. Based on these findings, a scheme of simultaneous adiabatic variation in the parameters is designed, such that any pair of initially equal energy trajectories continues to have the same energy at later times. These results are generalizations of a previous work [O. Polomarov and G. Shvets, Phys. Plasmas 13, 054502 (2006)] for a single, resonantly driven wave.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Axially Symmetric Energy Analyzer Based on the Electrostatic Decapole-Cylindrical Field

A new electron-optical scheme of an axially symmetric mirror energy analyzer based on the electrostatic decapole-cylindrical field is presented. A trajectory analysis of electron motion is performed. Design features of the proposed energy analyzer scheme are described. Second-order focusing regimes for two configurations are numerically calculated: (1) a ring source and its image located in the region of the inner cylinder and (2) a point source located at a great distance from the energy analyzer on the symmetry axis. It is shown that on the basis of the decapole-cylindrical field, a long-focal-length mirror energy analyzer with “axis–ring” type focusing can be built. Instrumental functions for two regimes of the energy analyzer are given; energy resolution and luminosity of the device are estimated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Machine learning for collective variable discovery and enhanced sampling in biomolecular simulation

Classical molecular dynamics simulates the time evolution of molecular systems through the phase space spanned by the positions and velocities of the constituent atoms. Molecular-level thermodynamic, kinetic, and structural data extracted from the resulting trajectories provide valuable information for the understanding, engineering, and design of biological and molecular materials. The cost of simulating many-body atomic systems makes simulations of large molecules prohibitively expensive, and the high-dimensionality of the resulting trajectories presents a challenge for analysis. Driven by advances in algorithms, hardware, and data availability, there has been a flare of interest in recent years in the applications of machine learning – especially deep learning – to molecular simulation. Furthermore, these techniques have demonstrated great power and flexibility in both extracting mechanistic understanding of the important nonlinear collective variables governing the dynamics of a molecular system, and in furnishing good low-dimensional system representations with which to perform enhanced sampling or develop long-timescale dynamical models. It is the purpose of this article to introduce the key machine learning approaches, describe how they are married with statistical mechanical theory into domain-specific tools, and detail applications of these approaches in understanding and accelerating biomolecular simulation.

74 ATOMIC AND MOLECULAR PHYSICS↗

Statistical spatio-temporal properties of the Laser MegaJoule speckle

This paper investigates a statistical model to describe the spatial and temporal properties of hot spots generated by the superimposition of multiple laser beams. In the context of the Laser MegaJoule design, we introduce the formula for contrasts, trajectories and velocities of the speckle pattern. Single bundle of four beams, two-cones and three-cones configurations are considered. Statistical properties of the speckle in the zone where all the beams overlap are studied with different configurations of polarizations. These properties are shown to be very different from the case of one single bundle of four beams. The configuration of polarization has only a slight effect in the two-cones or three cones configuration. Indeed, the impact of the double polarization smoothing is reduced in the area in which all the beams overlap, while it is much more significant when they split. Moreover, the size of the hot-spots decreases as the number of laser beams increases, but we show that their velocity decreases. As a matter of fact, the maximal velocity of hot spots is found to be only about 10{sup -5} of the velocity of light and the integrated contrast is about 15% when the beams overlap.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Science and Technology Review April/May 2012

This month's issue has the following articles: (1) Lawrence Livermore as the 'Go-To' National Security Laboratory - Commentary by Penrose (Parney) C. Albright; (2) Launching Traffic Cameras into Space - The Space-Based Telescopes for Actionable Refinement of Ephemeris project is designing nanosatellites to more accurately determine the trajectory of space objects orbiting Earth; (3)An Improved Tool for Nuclear Forensics - Resonance ionization mass spectrometry provides rapid isotopic analysis for studying materials derived from nuclear events; (4) A Simple Way to Better Protect Soldiers against Head Trauma - A modest increase in the foam padding used in Army helmets could significantly reduce brain injuries; and (5) Shocking Aluminum for Greater Understanding - Experiments using a laser beam to hit a thin film of aluminum provide an unprecedented look into the physics of shock waves traveling through a metal.

42 ENGINEERING↗

PROGRESS WITH NSLS-II INJECTION STRAIGHT SECTION DESIGN

The NSLS-II injection straight section (SR) consists of pulsed and DC bumps, septa system, beam trajectory correction and diagnostics systems. In this paper we discuss overall injection straight layout, preliminary element designs, specifications for the pulsed and DC magnets and their power supplies, vacuum devices and chambers and diagnostics devices. Prior to selecting the current 'conventional' design of the injection straight section we analyzed an option of injection via pulsed multipole pioneered at PF-AR. We found that this promising approach was not suited to the NSLS-II storage ring optics, since it would require a impractically compact arrangement of the injection straight section components and a complex modification of the transport line optics due to the strong focusing of the injected beam passing off the pulsed multipole axis. In addition, the requirement for a small injection transient of the stored beam orbit severely constrains the vertical alignment tolerance of the pulsed multipole. The design of the NSLS-II injection straight section is now completed with exception of transition chamber details, which will be adjusted to accommodate the actual layouts of the pulsed magnets.

43 PARTICLE ACCELERATORS↗

Bi-harmonic cantilever design for improved measurement sensitivity in tapping-mode atomic force microscopy

This paper presents a method and cantilever design for improving the mechanical measurement sensitivity in the atomic force microscopy (AFM) tapping mode. The method uses two harmonics in the drive signal to generate a bi-harmonic tapping trajectory. Mathematical analysis demonstrates that the wide-valley bi-harmonic tapping trajectory is as much as 70% more sensitive to changes in the sample topography than the standard single-harmonic trajectory typically used. Although standard AFM cantilevers can be driven in the bi-harmonic tapping trajectory, they require large forcing at the second harmonic. A design is presented for a bi-harmonic cantilever that has a second resonant mode at twice its first resonant mode, thereby capable of generating bi-harmonic trajectories with small forcing signals. Bi-harmonic cantilevers are fabricated by milling a small cantilever on the interior of a standard cantilever probe using a focused ion beam. Bi-harmonic drive signals are derived for standard cantilevers and bi-harmonic cantilevers. Experimental results demonstrate better than 30% improvement in measurement sensitivity using the bi-harmonic cantilever. Images obtained through bi-harmonic tapping exhibit improved sharpness and surface tracking, especially at high scan speeds and low force fields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An electrostatic autoresonant ion trap mass spectrometer

A new method for ion extraction from an anharmonic electrostatic trap is introduced. Anharmonicity is a common feature of electrostatic traps which can be used for small scale spatial confinement of ions, and this feature is also necessary for autoresonant ion extraction. With the aid of ion trajectory simulations, novel autoresonant trap mass spectrometers (ART-MSs) have been designed based on these very simple principles. A mass resolution {approx}60 is demonstrated for the prototypes discussed here. We report also on the pressure dependencies, and the (mV) rf field strength dependencies of the ART-MS sensitivity. Importantly the new MS designs do not require heavy magnets, tight manufacturing tolerances, introduction of buffer gases, high power rf sources, nor complicated electronics. The designs described here are very inexpensive to implement relative to other instruments, and can be easily miniaturized. Possible applications are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An integrated 6 MV linear accelerator model from electron gun to dose in a water tank

Purpose: The details of a full simulation of an inline side-coupled 6 MV linear accelerator (linac) from the electron gun to the target are presented. Commissioning of the above simulation was performed by using the derived electron phase space at the target as an input into Monte Carlo studies of dose distributions within a water tank and matching the simulation results to measurement data. This work is motivated by linac-MR studies, where a validated full linac simulation is first required in order to perform future studies on linac performance in the presence of an external magnetic field. Methods: An electron gun was initially designed and optimized with a 2D finite difference program using Child's law. The electron gun simulation served as an input to a 6 MV linac waveguide simulation, which consisted of a 3D finite element radio-frequency field solution within the waveguide and electron trajectories determined from particle dynamics modeling. The electron gun design was constrained to match the cathode potential and electron gun current of a Varian 600C, while the linac waveguide was optimized to match the measured target current. Commissioning of the full simulation was performed by matching the simulated Monte Carlo dose distributions in a water tank to measured distributions. Results: The full linac simulation matched all the electrical measurements taken from a Varian 600C and the commissioning process lead to excellent agreements in the dose profile measurements. Greater than 99% of all points met a 1%/1mm acceptance criterion for all field sizes analyzed, with the exception of the largest 40x40 cm{sup 2} field for which 98% of all points met the 1%/1mm acceptance criterion and the depth dose curves matched measurement to within 1% deeper than 1.5 cm depth. The optimized energy and spatial intensity distributions, as given by the commissioning process, were determined to be non-Gaussian in form for the inline side-coupled 6 MV linac simulated. Conclusions: An integrated simulation of an inline side-coupled 6 MV linac has been completed and benchmarked matching all electrical and dosimetric measurements to high accuracy. The results showed non-Gaussian spatial intensity and energy distributions for the linac modeled.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Software for Simulating the Surface Wear of Tools

Software for recording machining tracks in abrasive lapping is described. The software permits prediction of the shape and magnitude of the tool’s surface wear at the stage of process design, on the basis of the dimensions of the workpiece and the lap, their relative velocity, and the machining trajectory.

36 MATERIALS SCIENCE↗

Photovoltaic Deployment Scenarios toward Global Decarbonization: Role of Disruptive Technologies

To totally decarbonize global electrical systems using photovoltaics (PVs) in the 2050–2060 decade, the world would need to install 63.4 TW of PV. This article models and explores how a PV manufacturing ramp‐up trajectory toward this goal can be achieved while assuming that investors continue to make financially rational decisions avoiding stranded production assets and therefore protecting their return on investment. The model effectively exploits experience curve benefits in both the scaling of the manufacturing process and continued progress in product design technologies. The scale‐up challenge is amplified because trajectories that achieve this goal require an unprecedented ramp‐up of production capacity over just two decades, followed by relatively modest demand to maintain the installed base and support continued population growth. It is demonstrated that sustainable ramp‐up of manufacturing is indeed possible and shown that the deployment of the requisite manufacturing capacity can be accelerated and accomplished at lower total capital cost by the introduction of disruptive technologies that have lower capital intensity, embedded energy, or higher efficiency.

14 SOLAR ENERGY↗

Classical trajectory Monte Carlo code for simulating ion beam focusing or defocusing with magnetic elements modeled as current loops or current lines

A computational tool is described that can be used for designing magnetic focusing or defocusing systems. A fully three-dimensional classical trajectory Monte Carlo simulation has been developed. Ion trajectories are simulated in the presence of magnetic elements that can be modeled as any combination of current loops and current lines. Each current loop or line may be located anywhere in the system and oriented along any of the three coordinate axes. The configuration need not be axisymmetric. The solutions are obtained using normalized parameters, which can be used for easily scaling the results. Examples are provided of the utility of the code.

43 PARTICLE ACCELERATORS↗

WE-A-17A-10: Fast, Automatic and Accurate Catheter Reconstruction in HDR Brachytherapy Using An Electromagnetic 3D Tracking System

Purpose: In high dose rate brachytherapy (HDR-B), actual catheter reconstruction protocols are slow and errors prompt. The purpose of this study was to evaluate the accuracy and robustness of an electromagnetic (EM) tracking system for improved catheter reconstruction in HDR-B protocols. Methods: For this proof-of-principle, a total of 10 catheters were inserted in gelatin phantoms with different trajectories. Catheters were reconstructed using a Philips-design 18G biopsy needle (used as an EM stylet) and the second generation Aurora Planar Field Generator from Northern Digital Inc. The Aurora EM system exploits alternating current technology and generates 3D points at 40 Hz. Phantoms were also scanned using a μCT (GE Healthcare) and Philips Big Bore clinical CT system with a resolution of 0.089 mm and 2 mm, respectively. Reconstructions using the EM stylet were compared to μCT and CT. To assess the robustness of the EM reconstruction, 5 catheters were reconstructed twice and compared. Results: Reconstruction time for one catheter was 10 seconds or less. This would imply that for a typical clinical implant of 17 catheters, the total reconstruction time would be less than 3 minutes. When compared to the μCT, the mean EM tip identification error was 0.69 ± 0.29 mm while the CT error was 1.08 ± 0.67 mm. The mean 3D distance error was found to be 0.92 ± 0.37 mm and 1.74 ± 1.39 mm for the EM and CT, respectively. EM 3D catheter trajectories were found to be significantly more accurate (unpaired t-test, p < 0.05). A mean difference of less than 0.5 mm was found between successive EM reconstructions. Conclusion: The EM reconstruction was found to be faster, more accurate and more robust than the conventional methods used for catheter reconstruction in HDR-B. This approach can be applied to any type of catheters and applicators. We would like to disclose that the equipments, used in this study, is coming from a collaboration with Philips Medical.

07 ISOTOPE AND RADIATION SOURCES↗