Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transfer functions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Optical transfer function of Starlette retroreflector array

An optical transfer function was computed for the retroreflector array carried by the Starlette satellite (1975 10A). The range correction is given for extrapolating laser range measurements to the center of mass of the satellite. The gain function and active reflecting area of the array are computed for estimating laser-echo signal strengths.

Arnold, D. A.↗

Optical and infrared transfer function of the Lageos retroreflector array

The transfer function of the retroreflector array carried by the LAGEOS satellite (1976 39A) was computed at three wavelengths: 5230, 6943, and 106000 A. The range correction is given for extrapolating laser range measurements to the center of gravity of the satellite. The reflectivity of the array was calculated for estimating laser-echo signal strengths.

Arnold, D. A.↗

Transfer function verification and block diagram simplification of a very high-order distributed pole closed-loop servo by means of non-linear time-response simulation

Linear frequency domain methods are inadequate in analyzing the 1975 Viking Orbiter (VO75) digital tape recorder servo due to dominant nonlinear effects such as servo signal limiting, unidirectional servo control, and static/dynamic Coulomb friction. The frequency loop (speed control) servo of the VO75 tape recorder is used to illustrate the analytical tools and methodology of system redundancy elimination and high order transfer function verification. The paper compares time-domain performance parameters derived from a series of nonlinear time responses with the available experimental data in order to select the best possible analytical transfer function representation of the tape transport (mechanical segment of the tape recorder) from several possible candidates. The study also shows how an analytical time-response simulation taking into account most system nonlinearities can pinpoint system redundancy and overdesign stemming from a strictly empirical design approach. System order reduction is achieved through truncation of individual transfer functions and elimination of redundant blocks.

Mukhopadhyay, A. K.↗

Dark matter transfer function: Free streaming, particle statistics, and memory of gravitational clustering

The transfer function T(k) of dark matter (DM) perturbations during matter domination is obtained by solving the linearized collisionless Boltzmann-Vlasov equation. We provide an exact expression for T(k) for arbitrary distribution functions of decoupled particles and initial conditions, which can be systematically expanded in a Fredholm series. An exhaustive numerical study of thermal relics for different initial conditions reveals that the first two terms in the expansion of T(k) provide a remarkably accurate and simple approximation valid on all scales of cosmological relevance for structure formation in the linear regime. The natural scale of suppression is the free-streaming wave vector at matter-radiation equality, k{sub fs}(t{sub eq})=[4{pi}{rho}{sub 0M}/[<V-vector{sup 2}>(1+z{sub eq})]]{sup 1/2}. An important ingredient is a nonlocal kernel determined by the distribution functions of the decoupled particles which describes the memory of the initial conditions and gravitational clustering and yields a correction to the fluid description. This correction is negligible at large scales k<<k{sub fs}(t{sub eq}) but it becomes important at small scales k{>=}k{sub fs}(t{sub eq}). Distribution functions that favor the small momentum region yield longer-range memory kernels and lead to an enhancement of power at small scales k>k{sub fs}(t{sub eq}). Fermi-Dirac and Bose-Einstein statistics lead to long-range memory kernels, with longer-range for bosons, both resulting in enhancement of T(k) at small scales. For DM thermal relics that decoupled while ultrarelativistic we find k{sub fs}(t{sub eq}){approx_equal}0.003(g{sub d}/2){sup 1/3} (m/keV) [kpc]{sup -1}, where g{sub d} is the number of degrees of freedom at decoupling. For WIMPS we obtain k{sub fs}(t{sub eq})=5.88(g{sub d}/2){sup 1/3} (m/100 GeV){sup 1/2} (T{sub d}/10 MeV){sup 1/2} [pc]{sup -1}. For k<<k{sub fs}(t{sub eq}), T(k){approx}1-C[k/k{sub fs}(t{sub eq})]{sup 2} where C=O(1) and independent of statistics for thermal relics. We provide simple and accurate fits for T(k) in a wide range of small scales k>k{sub fs}(t{sub eq}) for thermal relics and different initial conditions. The numerical and analytic results for arbitrary distribution functions and initial conditions allow an assessment of DM candidates through their impact on structure formation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Eddy Current Case Study using NASA’s Transfer Function and Limited-Sample Probability of Detection Guidebooks

Probability of detection (POD) requirements for NASA fracture-critical human-rated systems can be met by (1) claiming ‘similarity’ to NASA Standard Nondestructive Evaluation (NDE) flaw sizes or (2) by inspector-specific POD demonstration, known as NASA Special NDE. Standard NDE flaw sizes are intended to represent the detection capability of most qualified inspectors, and were primarily based on POD studies in the development of the Space Shuttle Program Orbiter fracture control plan. However, these Standard NDE flaw sizes were based on fatigue cracks in flat panels of one material alloy over a limited range of panel thicknesses. While the POD study was comprehensive, the inspection conditions are relatively narrow. An evaluation of similarity between the Standard NDE POD study and flight component conditions is required to apply Standard NDE to specific flight component inspections. A similarity evaluation may include differences in materials, surface finish, component geometry (e.g., curvature, corners, welds), and inspection access. Similarity is typically based on a qualitative engineering evaluation. Recently, NASA published a quantitative methodology to assess similarity. If similarity is not supported by test and analysis, then the methodology provides a transfer function of flaw size for Special NDE POD demonstration. NASA recommends that Special POD demonstrations use flaws that are flight-like or more difficult to detect than flight component flaws, which are commonly induced fatigue cracks. Often, it is not feasible to induce fatigue cracks in flight component geometry, and therefore, a simpler representative geometry is used, commonly a flat panel, for POD demonstration. Inducing cracks in simple geometry specimens can be time-consuming and expensive, and thus, minimizing the number of flawed specimens is desired. Traditionally, NASA Special NDE demonstration was limited to MIL-HDBK-1823A methods or the binomial point-estimate method (PEM), commonly known as 29/29. Recently, NASA published a limited-sample POD (LS-POD) methodology for signal-response NDE techniques (e.g., eddy current) that provides POD demonstration with fewer specimens than previous approaches. LS-POD suggests a minimum of 10 flawed specimens, compared to 29 in the PEM and the suggested minimum of 40 from MIL-HDBK-1823A. The methodology also includes new guidance on evaluating the probability of false calls. In this presentation, these new transfer function and LS-POD methodologies are described and illustrated through an eddy current detection capability of far-side flaws on thin welded panels. A geometry-based transfer function is developed using electro-discharge machined (EDM) notches in flight component and simple geometry to estimate the Special NDE flaw size that is representative of the critical initial flaw size required by the fracture analysis. Then, fatigue cracks are induced in simple flat panels of the transferred flaw size, and the LS-POD methodology is used for Special NDE demonstration.

P. A. Parker↗

An Interactive MATLAB Program for Fitting Transfer Functions to Frequency Responses

A computer program called FRFit (Frequency Response Fitting) is described for fitting single-input single-output transfer function models to empirical frequency response data. The program is interactive in that the user specifies ``elementary factors'' (gain, delay, pure differentiators and integrators, and first- and second-order zeros and poles) by entering numerical values or moving sliders in a graphical user interface. A nonlinear optimization can then be performed to obtain maximum likelihood estimates of transfer function parameters and uncertainties to provide feedback on the modeling and refine estimates. Several examples are discussed, including the identification of aircraft pitch dynamics from simulation data and data reported in the literature, approximating Theodorsen's function of unsteady aerodynamics, and obtaining a reduced-order model of a computational fluid dynamics code describing the unsteady aerodynamics around an aeroelastic wing. The program has some usefulness as a teaching aid, and can be applied to model structure determination, reduced-order modeling, preliminary analysis, and simple system identification problems. The program was written in MATLAB and is planned for public release through the NASA Software Catalog.

System identification↗

Determination of lateral-stability derivatives and transfer-function coefficients from frequency-response data for lateral motions

A method is presented for determining the lateral-stability derivatives, transfer-function coefficients, and the modes for lateral motion from frequency-response data for a rigid aircraft. The method is based on the application of the vector technique to the equations of lateral motion, so that the three equations of lateral motion can be separated into six equations. The method of least squares is then applied to the data for each of these equations to yield the coefficients of the equations of lateral motion from which the lateral-stability derivatives and lateral transfer-function coefficients are computed. Two numerical examples are given to demonstrate the use of the method.

Donegan, James J↗

Optical transfer function of NTS-1 retroreflector array

An optical transfer function was computed for the retroreflector array carried by the NTS-1 satellite. Range corrections are presented for extrapolating laser range measurements to the center of mass of the satellite. The gain function of the array was computed for use in estimating laser-echo signal strengths.

Arnold, D. A.↗

Optical and infrared transfer function of the GEOS 3 retroreflector array

The transfer function of the retroreflector array carried by the Geos 3 satellite was computed at three wavelength: 5300, 6943, and 10600 A. The range correction is given for extrapolating laser range measurements to the center of gravity of the satellite. The reflectivity of the array was computed for estimating laser-echo signal strengths.

Arnold, D. A.↗

Method of calculating retroreflector-array transfer functions

Techniques and equations used in calculating the transfer functions to relate the observed return laser pulses to the center of mass of the Lageos satellite retroflector array, and for most of the retroreflector-equipped satellites now in orbit are described. The methods derived include the effects of coherent interference, diffraction, polarization, and dihedral-angle offsets. Particular emphasis is given to deriving expressions for the diffraction pattern and active reflecting area of various cube-corner designs.

Arnold, D. A.↗

Calibration of the modulation transfer function of surface profilometers with binary pseudo-random test standards: Expanding the application range

A modulation transfer function (MTF) calibration method based on binary pseudo-random (BPR) gratings and arrays [Proc. SPIE 7077-7 (2007), Opt. Eng. 47(7), 073602-1-5 (2008)] has been proven to be an effective MTF calibration method for a number of interferometric microscopes and a scatterometer [Nucl. Instr. and Meth. A 616, 172-82 (2010]. Here we report on a significant expansion of the application range of the method. We describe the MTF calibration of a 6 inch phase shifting Fizeau interferometer. Beyond providing a direct measurement of the interferometer's MTF, tests with a BPR array surface have revealed an asymmetry in the instrument's data processing algorithm that fundamentally limits its bandwidth. Moreover, the tests have illustrated the effects of the instrument's detrending and filtering procedures on power spectral density measurements. The details of the development of a BPR test sample suitable for calibration of scanning and transmission electron microscopes are also presented. Such a test sample is realized as a multilayer structure with the layer thicknesses of two materials corresponding to BPR sequence. The investigations confirm the universal character of the method that makes it applicable to a large variety of metrology instrumentation with spatial wavelength bandwidths from a few nanometers to hundreds of millimeters.

47 OTHER INSTRUMENTATION↗