Search NASA⌕ Search

SEARCH · Search NASA

Results for “Transient Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Practical Insights on Applying Simulation-Based Control Methods in Experimental Studies

Advanced nuclear reactors are crucial to the future of energy both in the United States and around the globe. In contrast to the current operating fleet, they are characterized as being deployable in remote locations and able to operate in semi-autonomous or autonomous fashion. This leap forward necessitates a new reactor control paradigm. Because advanced nuclear reactors are still under development in the United States, the creation of new control methods to achieve autonomous operations has been based on systems modeling and simulation. However, an important factor in successfully deploying these new control methods is the ability to seamlessly transition from simulation environments to real-world settings. Control methods tested in both simulation and experimental settings need to be investigated in the context of advanced reactor applications. This work developed a series of simple controllers for Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor operating in load-following scenarios. These controllers were tested in both simulation and experimental settings, and a comparative performance analysis was performed. The simulation tests leveraged the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) software developed in a previous stage of the current effort, along with the MARVEL Reactor Excursion and Leak Analysis Program (RELAP5-3D) and Monte Carlo N-Particle (MCNP) models. The experimental tests leveraged the COMMAND software, MARVEL models, and the U.S. Department of Energy Microreactor Program’s Microreactor Automated Control System (MACS). MACS was developed to serve as a control method testbed. It was customized to mirror the MARVEL microreactor, and COMMAND enabled MACS to emulate the physics of MARVEL. The load-following controller was developed using the simulation platform, with efforts to emulate real systems by introducing actuator saturation and noise. These factors were incrementally accounted for in the controller design. After finalizing the controller design, it was implemented with the experimental setup. The experimental conditions tested included an initial test under conditions similar to the final simulation test, and two additional scenarios. The first scenario introduced additional actuator saturation to account for equipment aging over time, which was unknown to the controller. The second scenario introduced sensor delay, a phenomenon anticipated with the use of remote operations or wireless communication in advanced reactors. These tests revealed several notable differences. While the controller performed well in simulation, it exhibited several limitations when transitioning to hardware. The main challenges involved maintaining the steady-state target power, as evidenced by larger error values between the true reactor power and setpoint power, as well as persistent oscillations in controlled reactor power. These issues could lead to unacceptable transient conditions in real reactor testing. Introducing actuator aging and stochastic delays in the experimental setup significantly impacted controller performance, resulting in increased overshoot and undershoot, and exacerbated error and oscillations previously mentioned. These findings underscore the importance of experimental testbeds for testing and validating control methods, as controllers developed using only theory and/or simulation may perform unexpectedly when applied to actual hardware. This research emphasizes the need for an experimental testbed for achieving such validation.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Enabling CO 2 Isothermal Compression Using Liquid Piston and Integrated Gas Cooler

This report outlines the development of a near-isothermal liquid piston compressor. Initially, a proof-of-concept experiment was conducted to validate the feasibility and potential of near-isothermal compression. A first-of-its-kind near-isothermal liquid piston compressor was then successfully built and tested. Additionally, a Matlab-based transient model was developed to capture performance trends accurately. These efforts laid the groundwork for developing a second-generation prototype with enhanced efficiency and design. Subsequent field tests at the Helix Innovation Center in Ohio demonstrated a cooling capacity of 2 kW with a COP of 1.64 at an ambient temperature of 25°C. An improved model was also created to suggest different heat exchanger geometries for better compression efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient Stability-Enhancing Method for Grid-Forming Inverters Under Current Limiting

The primary controller of a grid-forming (GFM) inverter governs the internal reference voltage and angle, which enables the inverter to naturally synchronize and share power with the connected grid; however, during disturbances on the grid caused by, e.g., line faults, overloading, or frequency and phase shifts, a GFM inverter can be pushed into a current-limited operation to protect the device against thermal damage. This can lead to a windup of the internal reference frequency generated by the primary controller and cause a total loss of synchronism with the grid. Here, to make the primary controller of GFM inverters more robust against transient instability, this paper proposes a method that manipulates the reference signals governed by the primary controller by introducing the concept of fictitious power. The fictitious power counteracts the integrator windup in the primary controller, which enables the current-limited inverter to conceive a stable operating point. This method is benchmarked against five state-of-the-art GFM inverter stabilization methods to evaluate its stability-enhancing performance. Full-order electromagnetic-transient simulations and experimental results of a hardware inverter test setup validate the benefits of the method to improve the transient stability of GFM inverters in the face of grid disturbances.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Microstructure-sensitive mechanical behavior of an additively manufactured psuedoelastic shape memory alloy

The additive manufacturing of shape memory alloys into complex geometries enables fabrication of advanced functional systems across a variety of fields and domains. This work presents results focused on the mechanical behavior of additively manufactured shape memory pseudoelastic NiTi. The deformation induced solid state phase transformation from austenite to martensite allows this system to accommodate large recoverable strains. This deformation behavior is fundamentally driven by crystal-scale transformation physics. Laser powder bed fusion processing reveals that the resulting microstructure, both grain morphology and crystallographic texture, is strongly dependent on the manufacturing processing history. Exhaustive mechanical testing demonstrates that these microstructural factors strongly impact both tensile and cyclic stress–strain behavior. Cyclic dissipative behavior, however, is similar across all tested microstructures following an initial transient period. Remarkably, analysis of spatial strain fields during tensile loading reveals two distinctly different localization “modes”. The first is initiation of localized deformation bands which continuously propagate through the tensile bar during loading. In the second mode localization is observed but lacks propagation; instead additional localization cites nucleate during subsequent loading. The latter phenomena is suspected to be driven by grain-scale deformation physics as the localized band morphologies coincide with grain morphologies. These phenomena strongly impact the resulting aggregate stress–strain behavior. Hence, manufacturers and designers of psuedoelastic functional components must at the very least consider the potential variability in properties when considering additive manufacturing processing. More ideally the process–structure–property relations can be used to further tailor and optimize final functional performance.

Additive manufacturing↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System with Multiple Grid-Forming Inverters: Preprint

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). The CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Controller-Hardware-in-the-Loop Evaluation of a Microgrid Controller for a Microgrid System With Multiple Grid-Forming Inverters

This paper presents the laboratory evaluation of a commercial Microgrid Management System (MGMS) implemented in the real-world Bronzeville Microgrid which features a futuristic scenario with high renewable energy integration and the use of multiple Grid-Forming (GFM) inverters. The primary objective of the performance evaluation for the MGMS is to assess the MGMS's capability to dispatch GFM units, including a GFM PV unit and two GFM battery units, to maintain the system stability and ensure economic operation, thus guaranteeing the microgrid's resilience during prolonged outages and dynamic events. The laboratory controller hardware-in-the-loop provides realistic testing environment through detailed electromagnetic transient modeling of the microgrid system, hardware MGMS, and standard communication protocols (DNP3). This CHIL evaluation shows how the MGMS effectively manages the GFM inverters, highlighting its performance in maintaining stability, reliability, and survivability in a microgrid environment with a high penetration of renewable energy sources.

controller hardware-in-the-loop↗

Calculation of monomer yields, verification of PG concentration approximation, catalyst comparison for neat aromatic RCF, SEM micrographs for postreaction pulps, yields of aqueous-phase sugar derivatives after PG-H2O RCF, reactor pressure transients, GPC comparing pre- and postreaction organic solvent composition, PG-H2O miscibility testing, GPC probing dimer/oligomer fractionation in PG-H2O mixtures for

Reductive catalytic fractionation (RCF) is an effective lignin-first biorefining method to extract lignin as a stabilized oil from lignocellulosic biomass. To realize RCF at scale, process modeling has shown that minimizing the use of exogenous organic solvents is critical. To this end, here we investigate the ability of lignin-derived monomers to act as either solvents or cosolvents for RCF. We begin by examining the influence of lignin-derived aromatic compounds (4-propylguaiacol, 4-propylphenol, and propylbenzene) on RCF monomer yields and subsequently extend our analysis to mixtures of 4-propylguaiacol and either methanol or water. We demonstrate that 4-propylguaiacol is an effective solvent for lignin extraction and depolymerization during RCF, especially when used in combination with water as a cosolvent. Cosolvent mixtures of 4-propylguaiacol and water enable up to 81% lignin extraction, monomer yields up to 25 wt %, and postreaction phase separation. However, unlike methanol, water as a cosolvent fails to inhibit aromatic ring hydrogenation when conducted over Ru/C as a catalyst, potentially leading to excess hydrogen consumption in a process utilizing this approach. Nonetheless, these results suggest a promising strategy for eliminating external organic solvents from RCF by utilizing mixtures of lignin-derived compounds and water as alternative extraction solvents.

biorefining↗

Recent High Burnup LOCA Testing at Oak Ridge National Laboratory

To improve fuel cycle economics, increasing the fuel burnup limit in light-water reactors requires a solid technical foundation. Observations from experiments at Halden and Studsvik highlighted severe fuel fragmentation during loss-of-coolant-accident (LOCA) conditions, indicating a need for further technical considerations. These experiments suggest that the fragmentation threshold for high-burnup fuel might be influenced by pre-transient power levels. Consequently, additional LOCA test data are essential to complement existing findings and to deepen our understanding. Oak Ridge National Laboratory’s Severe Accident Test Station has been instrumental in advancing knowledge about high-burnup fuel fragmentation, relocation, and dispersal. This milestone report details two high-burnup LOCA tests designed to evaluate the effects of terminal temperature and grid spacers (or cladding restraints) on fuel fragmentation and relocation susceptibility. In addition, BISON fuel performance modeling and out-of-cell benchmark testing were conducted to better interpret the in-cell test results. These tests were developed in collaboration with fuel vendors to ensure that the results provide valuable data for topical reports and support the Nuclear Regulatory Commission’s review.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Performance Evaluation of Drain Water Heat Recovery Exchangers for Heat Pump Water Heaters

Water heating constitutes approximately 18% of energy consumption and is the second largest energy expenses in United States homes. Heat pump water heaters (HPWHs) are energy efficient technologies with lower carbon footprints as compared to conventional water heating technologies, such as gas and electrical resistance heaters. The performance of water-source HPWHs can be improved by recovering heat from blackwater using drain heat recovery heat exchangers. Depending on water draw patterns of single family and multifamily residences, the operation and heat transfer performance of these heat exchangers are highly transient. This paper examines the thermo-hydraulic performance of a drain heat recovery heat exchanger during its transient and steady-state operations. The heat recovery performance of the exchanger was evaluated at different inlet temperatures and flow rates ranging from 9°C to 36°C and 0.03 kg/s to 0.28 kg/s, respectively. The obtained effectiveness varies from 45%–85% depending on the operating conditions. The test facility, steady-state and transient experimental procedures are reported in detail. Further, the effect of operating conditions on the effectiveness is discussed. The experimental approach and results of the study will provide insights into the transient operation of drain recovery heat exchangers as well as, guide sizing for various steady state conditions.

Krishnan, Easwaran↗

Simulation and Experimental Validation of an Integrated Heat Pump – Thermal Energy Storage Using a Room-Temperature Phase Change Material

As the dependence on electrical heat pumps (HPs) and intermittent renewables increases, grid strains are expected to grow. This necessitates an energy storage system to reduce the mismatch between energy supply and demand. Thus, a proposed dual-mode commercially available 14.1 kW HP was integrated with a single 22°C phase change material (PCM) thermal storage system (TES) to load-shift both cooling and heating loads. The HP-TES system was manufactured and experimentally tested using a novel test matrix based on AHRI 210/240 psychrometric conditions. Furthermore, transient dual-mode system-level HP-TES models were developed in Modelica and validated using the experimental test conditions. Base HP cooling and heating experimental tests at ambient temperatures of 35°C and −8.3°C show that the modified HP-TES maintained the rated system capacity and performance. The HP-TES discharge provided approximately 30% and 50% reductions in cooling and heating demand, respectively. The transient HP-TES models predicted system capacity and total power input for discharge and recharge operating modes within ±4% mean percentage error, and recharge power input within ±2%, with maximum errors occurring at the equipment startup. During system operation, the sources of model deviations are first-order polynomial fits of the PCM digital scanning calorimetry (DSC) data and unaccounted supercooling in the PCM during solidification. Nonetheless, the model predictions agree with the experimental tests, demonstrating the availability of robust, accurate, and validated transient models that can be used for further validation and the development of system controls.

25 ENERGY STORAGE↗

Code Validation of SAM Using Forced and Natural Circulation Data from NACIE-UP Benchmark

Heavy liquid metals (HLMs) are promising candidates as coolants of Generation IV fast reactors due to their thermophysical properties. In the last decade, experimental work has been proposed as part of research and development efforts to develop such systems. In this context, researchers from the Brasimone Research Center have conducted many experiments using the Natural Circulation Experiment Upgrade (NACIE-UP) facility to study the thermofluid dynamic behavior of HLMs in rod bundle configurations with or without wire wrappers. This facility consists of a rectangular loop operated with lead-bismuth eutectic. Sensors across the loop monitor relevant parameters, i.e. temperatures, heat transfer, and flow conditions. Here, in the present work, we carefully select published data from NACIE-UP to validate the System Analysis Module (SAM), a modern system analysis code developed at Argonne National Laboratory. We developed one SAM model using specifications of the facility geometry and materials existing in relevant papers and reports. On top of that, these references provided the boundary conditions for simulating natural circulation and forced convection experiments in either steady or transient conditions. The SAM model simulates five test cases with diverse operating conditions. Ultimately, the code is proven to predict temperatures and mass flow rates that closely match the experiments. The discrepancies between numerical predictions and diverse transients are limited to a few degrees Celsius, showcasing that SAM is well suited for analyzing nuclear systems relying on HLM coolants.

advanced reactors↗

Observation of Electromagnetic Transients in a Nb3Sn 4-layer Dipole Mirror Magnet

During testing of the Stress Managed Cosine-Theta dipole mirror magnet SMCTM1, magnet quenches were observed following large voltage spikes in the half-coil voltage taps which preceded normal quench initiation. Following some recent work at CERN measuring power current converter transients in relation to flux jumps, an additional differential current probe was added to the magnet instrumentation. Measurements of this probe, as well as the half coil voltage taps show a fast and substantial current change preceding the quench, hinting at coil motion. A simple model based on relative shift of the inner and outer layer coils was developed which suggests the magnitude of coil shift events is on the estimated relative coil shift from the magnet constraint conditions. The behavior is shown to be reversible and characteristic of stick-slip.

Krave, Steven [Fermilab] (ORCID:0000000217521457)↗

PARET/ANL (V.7.7) Verification and Validation Report

This report documents the software testing which has been performed for the PARET/ANL version 7.7 software. The software testing is based on code capabilities identified by research reactor analysts as frequently used in their safety analyses. The verification and validation procedures have been performed and documented to address the steady-state capabilities of the software, as described in Chapter 2, and the transient capabilities, as described in Chapter 3. Testing based on the comparison between PARET/ANL calculations and analytical solutions, hand calculations, or other code calculations of the test cases confirms that all the identified capabilities of the software were implemented correctly. In addition, results from code comparisons against SPERT-I and SPERT-IV experiments for various flow rates are reported for the peak power, energy release and cladding surface temperature. The comparisons showed overall good agreement for the peak power and conservative predictions of the cladding surface temperature

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PARET/ANL v7.7 Verification and Validation Report

This report documents the software testing which has been performed for the PARET/ANL version 7.7 software. The software testing is based on code capabilities identified by research reactor analysts as frequently used in their safety analyses. The verification and validation procedures have been performed and documented to address the steady-state capabilities of the software, as described in Chapter 2, and the transient capabilities, as described in Chapter 3. Testing based on the comparison between PARET/ANL calculations and analytical solutions, hand calculations, or other code calculations of the test cases confirms that all the identified capabilities of the software were implemented correctly. In addition, results from code comparisons against SPERT-I and SPERT-IV experiments for various flow rates are reported for the peak power, energy release and cladding surface temperature. The comparisons showed overall good agreement for the peak power and conservative predictions of the cladding surface temperature.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Deep Learning-Based Dynamic Modeling of Three-Phase Voltage Source Inverters

Inverter-based resource (IBR) models are necessary to analyze modern power system stability and create effective control strategies. Modeling IBRs in converter-rich power systems is crucial, yet challenging due to the lack of commercial information on converter topologies and control parameters. This paper proposes novel convolutional neural network (CNN)–based data-driven techniques for modeling IBRs, addressing adaptability and proprietary concerns without requiring internal system physics knowledge. The proposed method is tested using real grid-tied commercial IBR transient data and demonstrates effectiveness and accuracy. Furthermore, the developed modeling approach is integrated and implemented in the open-source power distribution simulation and analysis tool, GridLAB-D, to illustrate the potentiality of dynamic analysis of large-scale power systems with high IBRs.

deep learning, artificial intelligence↗

A Review of the Generic Grid-Forming Model Used by the System Operator in Chile

The objective in this project is to verify the applicability of using generic electro-magnetic transient domain models of GFM technology through a wide range of tests and system conditions proposed by subject matter experts of GFM technology through a wide range of tests and system conditions proposed by subject matter experts. For this study, we used the generic GFM electro-magnetic transient model available in the EMTP (Electromagnetic Transient Program) software library, and we assessed the model’s various GFM capabilities through 12 tests. In this report, we compare the performance of the model with that of an original equipment manufacturer (OEM) GFM model. We also share the key insights and lessons learned from this work.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance Evaluation of Multi-Vendor Grid-Forming Inverters for Grid-Connected Operation Through Hardware Experimentation

This paper presents the functional performance evaluation tests of multiple (three) commercial grid-forming (GFM) inverters when they operate in parallel with the grid through hardware experiments. The goal of these tests is to explore and benchmark the GFM inverters' functionalities and dynamic response when they are operated in parallel with power grids. Both steady-state (changing the inverter's frequency and voltage droop) and transient (adding step changes to grid's frequency/voltage) tests are performed for each GFM inverter with the same testing circuit and testing protocol. The key findings are summarized as follows: 1) The GFM inverters can be dispatched through frequency and voltage droop intercepts to output the target power; and 1) the GFM inverters automatically respond to system frequency and voltage events to output the needed power; 3) all the GFM inviters shows stability issues when absorbing reactive power from the grid.

frequency droop↗