Search NASA⌕ Search

SEARCH · Search NASA

Results for “Trapped Ion Frequency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Atomic ion clock with two ion traps, and method to transfer ions

An atomic ion clock with a first ion trap and a second ion trap, where the second ion trap is of higher order than the first ion trap. In one embodiment, ions may be shuttled back and forth from one ion trap to the other by application of voltage ramps to the electrodes in the ion traps, where microwave interrogation takes place when the ions are in the second ion trap, and fluorescence is induced and measured when the ions are in the first ion trap. In one embodiment, the RF voltages applied to the second ion trap to contain the ions are at a higher frequency than that applied to the first ion trap. Other embodiments are described and claimed.

Prestage, John D.↗

A new ion and electron detector for ion cyclotron resonance spectroscopy.

A new detector using an extremelly driven tuned circuit has been developed for use in ion cyclotron resonance spectroscopy experiments. Based on the Q-meter circuit, this detector will operate at frequencies greater than 1 MHz at rf levels less than 1 mV. Operation in the frequency range 1-15 MHz allows the use of higher magnetic fields for more efficient storage of low mass ions in the trapping mode of operation. In the frequency range 2-6 MHz electrons can be detected in the ion cyclotron resonance cell by their resonant motion in the trapping plane.

Huntress, W. T., Jr.↗

Excitation of fishbone-like mode in tokamaks due to bounce resonances of trapped thermal ions

When the drift kinetic effect of thermal ions is taken into account, a high-frequency fishbone-like mode (FLM) is found to be driven unstable by trapped thermal ions (TTIs) in tokamak plasmas, according to self-consistent magneto-hydrodynamic (MHD)-kinetic hybrid modeling utilizing the MARS-K code [Liu et al., Phys. Plasmas 15, 112503 (2008)] as well as an analytic theory. It is found that, similar to energetic particles, TTIs can also stabilize the internal kink mode, whereas the FLM is excited when the effective beta of TTIs exceeds a threshold value. The real frequency of the FLM is comparable to the bounce frequency of TTIs. The mode structure of the FLM can be significantly different from the conventional step-like function for the associated plasma radial displacement. This drift kinetic induced modification of the mode structure near the q = 1 surface is captured by non-perturbative MHD-kinetic hybrid computations with MARS-K. Furthermore, the FLM can only be triggered by TTIs at sufficiently high thermal temperatures. Both the FLM and the internal kink can be stabilized by sufficiently fast plasma toroidal rotation and parallel sound wave damping. These two conditions of high thermal temperature and (fast) flow stabilization, though making it challenging to observe the TTI-driven FLM in present day experiments, are favorable for the mode excitation in future reactor scale devices.

36 MATERIALS SCIENCE↗

Proceedings of the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting

This document is a compilation of technical papers presented at the 30th Annual Precise Time and Time Interval (PTTI) Systems and Applications Meeting held 1-3 December 1998 at the Hyatt Regency Hotel at Reston Town Center, Reston, Virginia. Papers are in the following categories: 1) Recent developments in rubidium, cesium, and hydrogen-based atomic frequency standards, and in trapped-ion and space clock technology; 2) National and international applications of PTTI technology with emphasis on GPS and GLONASS timing, atomic time scales, and telecommunications; 3) Applications of PTTI technology to evolving military navigation and communication systems; geodesy; aviation; and pulsars; and 4) Dissemination of precise time and frequency by means of GPS, geosynchronous communication satellites, computer networks, WAAS, and LORAN.

Breakiron, Lee A.↗

Ground-Based Investigations with the Cryogenic Hydrogen Maser

The room temperature hydrogen maser is an active atomic oscillator used as a high-frequency-stability local oscillator for radio astronomy, metrology, and spacecraft navigation, and in tests of fundamental physics. The cryogenic hydrogen maser (CHM) operates at 0.5 K, employing superfluid helium-coated walls to store the masing hydrogen atoms. We are investigating whether the CHM may provide better frequency stability than the room temperature hydrogen maser: one to three orders of magnitude improvement may be possible because of greatly reduced thermal noise and larger signal power. Exceptional frequency stability will be required for spacecraft tracking in future deep-space missions, for space-based tests of relativity and gravitation, and for local (i.e., flywheel) oscillators used with absolute frequency standards such as laser-cooled atomic fountains and linear ion traps. These new devices are passive high-resolution frequency discriminators. Alone, they cannot function as superior atomic clocks; their effective operation depends on being integrated with an active local oscillator with excellent short term stability - such as that possible with the CHM.

Walsworth, Ronald L.↗

Ultra-narrow-linewidth hybrid-integrated self-injection locked laser at 780 nm

Narrow-linewidth lasers are essential across a wide range of applications, including classical and quantum sensing, trapped ion systems, position/navigation/timing systems, optical clocks, and microwave frequency synthesizers. In the visible and near-visible spectrum, low-noise lasers are particularly important for laser trapping and cooling techniques, which are vital for trapped ion quantum computing, sensing, and atomic clocks. In this context, our work showcases a hybrid-integrated narrow-linewidth laser that operates at 780 nm, achieving a self-heterodyne linewidth of 105 Hz. To validate the experimental results, we performed a numerical analysis that combines insights from a many-body theory applied to the gain region with a travelling-wave model to capture the laser dynamics. Our investigation further delves into how the linewidth of the self-injection locked lasers is influenced by the parameters of micro-ring resonators, aiming to assess the potential for achieving Hz-level integrated laser linewidths at 780 nm. This work not only demonstrates the technical feasibility of Hz-level narrow-linewidth lasers but also lays the groundwork for future explorations in the field.

Prokoshin, Artem (ORCID:0009000699760238)↗

High resolution threshold photoelectron spectroscopy by electron attachment

A system is provided for determining the stable energy levels of a species ion, of an atomic, molecular, or radical type, by application of ionizing energy of a predetermined level, such as through photoionization. The system adds a trapping gas to the gaseous species to provide a technique for detection of the energy levels. The electrons emitted from ionized species are captured by the trapping gas, only if the electrons have substantially zero kinetic energy. If the electrons have nearly zero energy, they are absorbed by the trapping gas to produce negative ions of the trapping gas that can be detected by a mass spectrometer. The applied energies (i.e. light frequencies) at which large quantities of trapping gas ions are detected, are the stable energy levels of the positive ion of the species. SF6 and CFCl3 have the narrowest acceptance bands, so that when they are used as the trapping gas, they bind electrons only when the electrons have very close to zero kinetic energy.

Chutjian, A.↗

Spectroscopy and dynamics of the v = 1 levels derived from the OH(D) stretching modes in the I‾∙HDO complex using CW and time-resolved, resonant two-photon infrared excitation of the cryogenically cooled ions

The vibrational energy levels of the two isotopomers adopted by the I‾∙HDO ion-molecule complex occur such that the OH(D) stretching fundamentals span its dissociation energy, thus enabling a spectroscopic investigation of the dynamics displayed by a system prepared in the vicinity of the dissociation threshold. This regime is explored using infrared photoexcitation of the mass-selected complexes cooled in a cryogenic radiofrequency (Paul) ion trap. Survey spectra are obtained at modest resolution using two-color, IR-IR photodissociation with nanosecond lasers to establish the level structure and unimolecular decay dynamics of the v = 1 and 2 levels of the bound OH(D) oscillator. The v = 1 levels are prepared by fixed frequency excitation in the trap and the absorption spectra arising from this excited state are probed by photofragmentation of the complex with a second pulsed IR laser after a variable delay time (0 to 20 ms). The transitions to levels above the dissociation threshold for I‾ + HDO formation are observed to be sharp (~5 cm -1 FWHM). At low pressure, the bound OD (v = 1) population relaxes very slowly (~3 ms), consistent with resonant fluorescence in the IR. The collisional quenching rate constants of this level by the He buffer gas were estimated to be on the order 3 x 10 -12 cm 3 /s based on a crude Stern-Volmer analysis. Here, the rotational fine structure and linewidths (≲0.01 cm -1 FWHM) arising from transitions of the non-bonded OH stretch fundamental of the OD-bound isotopomer that lies just above the dissociation energy are determined using single photon photodissociation by excitation of the 10 K ions with a single-frequency, CW IR laser in the ion trap.

Cryogenic ion infrared spectroscopy↗

Magnetospheric dynamics and wave-particle interactions

It has been demonstrated that two general classes of wave-particle interactions are of great importance for magnetospheric dynamics. Electromagnetic and electrostatic plasma instabilities give rise to relatively narrow-banded spontaneous emissions (e.g., ELF hiss, chorus, three-halves noise, ion cyclotron and ion-plasma-frequency turbulence) that can scatter trapped particles into the loss cone, leading to modified pitch-angle distributions, stable trapping limits, diffuse aurora, proton precipitation events, etc. The current-driven plasma instabilities give rise to impulsive ion acoustic or Buneman mode turbulence that provides very effective energy transfer (via the anomalous conductivity mechanism) at the bow shock and in regions where strong field-aligned currents are observed. We review these interactions and identify significant open questions that must be investigated during the IMS.

Scarf, F. L.↗

Dynamics of charged particles in a Paul radio-frequency quadrupole trap

A molecular-dynamics simulation of hundreds of ions confined in a Paul trap has been performed. The simulation includes the trapped particles' micromotion and interparticle Coulomb interactions. A random walk in velocity was implemented to bring the secular motion to a given temperature which was numerically measured. When the coupling Gamma is large the ions from concentric shells which undergo a quadrupole oscillation at the RF frequency, while the ions within a shell form a 2D hexagonal lattice. Ion clouds at 5 mK show no RF heating for q(z) less than about 0.6, whereas rapid heating is seen for qz = 0.8.

Prestage, J. D.↗

Space Flyable Hg(sup +) Frequency Standards

We discuss a design for a space based atomic frequency standard (AFS) based on Hg(sup +) ions confined in a linear ion trap. This newly developed AFS should be well suited for space borne applications because it can supply the ultra-high stability of a H-maser but its total mass is comparable to that of a NAVSTAR/GPS cesium clock, i.e., about 11kg. This paper will compare the proposed Hg(sup +) AFS to the present day GPS cesium standards to arrive at the 11 kg mass estimate. The proposed space borne Hg(sup +) standard is based upon the recently developed extended linear ion trap architecture which has reduced the size of existing trapped Hg(sup +) standards to a physics package which is comparable in size to a cesium beam tube. The demonstrated frequency stability to below 10(sup -15) of existing Hg(sup +) standards should be maintained or even improved upon in this new architecture. This clock would deliver far more frequency stability per kilogram than any current day space qualified standard.

clocks cesium atomic frequency standard Hg ions li↗

Low-energy ion distribution functions on a magnetically quiet day at geostationary altitude /L = 7/

Ion energy and pitch angle distribution functions are examined for a magnetically quiet day using averaged data from ATS 6. For both field-aligned and perpendicular fluxes, the populations have a mixture of characteristic energies, and the distribution functions can be fairly well approximated by Maxwellian distributions over three different energy bands in the range 3-600 eV. Pitch angle distributions varying with local time, and energy distributions are used to compute total ion density. Pitch angle scattering mechanisms responsible for the observed transformation of pitch angle distribution are examined, and it is found that a magnetic noise of a certain power spectral density belonging to the electromagnetic ion cyclotron mode near the ion cyclotron frequency can be effective in trapping the field aligned fluxes by pitch angle scattering.

Singh, N.↗

An apparatus for the electrodynamic containment of charged macroparticles

The dynamic moition of the ions contained in the trapped (199)Hg+ frequency standard contributes to the stability of the standard. In order to study these dynamics, a macroscopic analog of the (199)Hg+ trap is constructed. Containment of micron-sized particles in this trap allows direct visual observation of the particles' motion. Influenced by the confining fields and their own Coulomb repulsion, the particles can form stable arrays.

Williams, A.↗

Reply to Mr. Silvertooth's Letter

The JPL experiment is indeed similar in spirit to that of Cialdea, but not the earlier MIT experiments (which involved the comparison of laser cavities).

Cialdea MIT experiments atomic frequency standards↗

Ion Trapping Studies and Mitigation Strategies for the EIC ERL-Based Strong Hadron Cooler

An Energy Recovery Linac based strong hadron cooler was previously considered for the Electron-Ion Collider. The required electron beam parameters for variable-energy strong hadron cooling place significant constraints on ion trapping and collective effects. This paper presents initial studies of these constraints through a combination of analytical modelling and numerical simulations of ion production, trapping behaviour, and mitigation strategies. A multi-bunch tracking framework based on ELEGANT with the ionEffects module is used to simulate machine operation over millisecond time scales, corresponding to more than 3 × 10^5 electron bunches. The simulations include modelling of ionisation processes together with transverse electron–ion dynamics, allowing the evolution and accumulation of ions to be investigated. Analytical expressions based on Gaussian beam distributions are used to estimate ion trapping conditions and benchmark the simulation results. A bi-periodic bunch spacing scheme is also investigated as a possible mitigation method by detuning the ion oscillation frequency. These studies provide an initial assessment of ion trapping in the strong hadron cooler and demonstrate possible approaches for reducing beam–ion effects.

Bi, R. [Lancaster University, Cockcroft Institute]↗

27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting

This document is a compilation of technical papers presented at the 27th Annual Precise Time and Time Interval (PTTI) Applications and Planning Meeting, held November 29 - December 1, 1995 at San Diego, CA. Papers are in the following categories: Recent developments in rubidium, cesium, and hydrogen-based frequency standards; and in cryogenic and trapped-ion technology; International and transnational applications of PTTI technology with emphasis on satellite laser tracking, GLONASS timing, intercomparison of national time scales and international telecommunications; Applications of PTTI technology to the telecommunications, power distribution, platform positioning, and geophysical survey industries; Applications of PTTI technology to evolving military communications and navigation systems; and Dissemination of precise time and frequency by means of Global Positioning System (GPS), Global Satellite Navigation System (GLONASS), MILSTAR, LORAN, and synchronous communications satellites.

Sydnor, Richard L.↗