Search NASA⌕ Search

SEARCH · Search NASA

Results for “Two phase flow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Generalized symmetry constraints on deformed 4D SCFTs

We explore the consequence of generalized symmetries in four-dimensional N = 1 superconformal field theories. First, we classify all possible supersymmetric gauge theories with a simple gauge group that have a nontrivial one-form symmetry and flows to a superconformal field theory. Upon identifying unbroken discrete zero-form symmetries from the Adler-Bell-Jackiw (ABJ) anomaly, we find that many of these theories have mixed zero-form or one-form ’t Hooft anomalies. Then we classify the relevant deformations of these SCFTs that preserve the anomaly. From this mixed anomaly together with the anomalies of the discrete zero-form symmetries, we find obstructions for the relevant deformations of these SCFTs to flow to a trivially gapped phase. We also study non-Lagrangian SCFTs formed by gauging copies of Argyres-Douglas theories and constrain their deformations. In particular, we explore a new duality between the diagonal gauging of two D 3 ( S U ( N ) ) theories and S U ( N ) gauge theory with two adjoints. We also repeat our analysis for a host of nonsupersymmetric gauge theories having nontrivial one-form symmetry including examples that appear to flow to Bank-Zaks type CFTs. Published by the American Physical Society 2025

Kang, Monica Jinwoo (ORCID:0000000204542064)↗

Advancing Thermal-Hydraulic Modeling Capabilities for Molten Salt Reactors in Pronghorn

This is an M2 report for the NEAMS program. This work focuses on advancing the modeling and simulation capabilities for Molten Salt Reactors (MSRs) within Pronghorn, addressing key thermal-hydraulic challenges that must be addressed for the safe and efficient operation of these advanced reactors. This report summarizes the development and validation of the following new models in Pronghorn: (i) two-equation RANS turbulence models, (ii) near-wall turbulence corrections due to curvature and roughness, and (iii) multidimensional two-phase drift-flux models. For each of these cases, along with the experimental validation, an application study of interest to MSRs is presented. In addition, this report also presents recent improvements in the domain-overlapping coupling between Pronghorn and SAM to address the cases of weakly compressible flow and flow reversal. Finally, an MSR action that greatly simplifies the setup of MSR models using NEAMS tools is described.

42 ENGINEERING↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application

Previously, we reported two-phase capillary-based cooling using narrow (200 to 1000 ..mu..m) heater bridge copper inverse opal (CIO) wicks with heat flux level of 1400 Wcm -2 and superheat ~ 10 degrees C. Here, we demonstrate the area scaling of the proposed technology to a large-area micro-cooler for high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary-wicking in a 25-..mu..m-thick CIO with an open silicon microchannel 3D-manifold for liquid delivery and vapor extraction, achieving a high heat flux ~ 400 Wcm -2 over a heated area of 10 x 10 mm 2 . For a range of inlet water flowrates from 5 to 60 g(min) -1 , we achieved total thermal resistances and vapor qualities of 0.68 cm 2 degrees CW -1 to 0.2 cm 2 degrees CW -1 and 0.55 to 0.12, respectively. The flowrates are 10x smaller than those of conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances ranges from 0.05 to 0.02 cm 2 degrees CW -1 with temperature superheat of 8 to 6 degrees C, respectively. While the overall performance of the large-area (10 x 10 mm 2 ) capillary-based micro-cooler degraded compared to the previous demonstration of the technology for a heated area of 5 x 5 mm 2 , however, preliminary CFD modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

Approaches for Water Removal in Direct-Fired sCO 2 Power Cycles

There is interest in investigation of water removal processes in direct fired sCO 2 flows, as this may potentially lead to greater system efficiency as the removal of this contaminant will result in sCO 2 behaving close to idealized behaviors. Water removal should be split into a two-step process, condensation of the water, followed by separation of the liquid phase water from the sCO 2 . The two main avenues of condensation are manipulation of pressure and temperature for phase change. For this paper, temperature-based phase change is the primary focus through the implementation of heat exchangers. Of the heat exchangers investigated it was found that printed circuit heat exchangers (PCHEs) could be an alternative for this use case, though the specific design of flow channel geometry and flow direction depends on the specific system case and cannot be determined at this point. For water separation there were four processes identified, all of which already assume water is in liquid phase at that point in the system. Of these separation avenues the best candidate is the hydrocyclone as it has a proven history of separating liquid-liquid phase mixtures with small density differences in oilfield use, in addition they have been investigated and modeled specifically for water separation for sCO 2 flows and the footprint is relatively small.

20 FOSSIL-FUELED POWER PLANTS↗

Development of a Hybrid Single/Two-Phase Capillary-Based Micro-Cooler Using Copper Inverse Opals Wick with Silicon 3D Manifold for High-Heat-Flux Cooling Application: Preprint

Previously, two-phase capillary-based cooling from narrow (200-1,000 micrometer) heater-bridge copper inverse opal (CIO) wicks with heat flux levels exceeding 1,400 watts per square cm with a low superheat of approximately 10 degrees C was demonstrated. Here, we demonstrate the area scaling of the proposed technology to large-area micro-cooler for the high-heat-flux cooling of microprocessors and power electronics. We developed a hybrid single/two-phase micro-cooler that relies on capillary wicking in 25-micrometer-thick CIOs with an open channel silicon 3D-manifold for liquid delivery and vapor extraction, to achieve a high heat flux of approximately 400 watts per square cm over a heated area of 1 square cm. For the range of inlet water (21 degrees C water temperature) flowrates from 5 to 60 mL per min, we achieved total thermal resistances and vapor qualities of 0.68-0.2 square cm Kelvin per watt and 0.55-0.12, respectively. The high heat flux levels are achieved with flowrates that are 10 times smaller than conventional single- or two-phase microchannel cooling technology. The corresponding two-phase thermal resistances are in the range of 0.05 to 0.02 square cm Kelvin per watt with temperature superheat of 8 to 6 degrees C. While the overall performance of the large-area (10 by 10 square millimeter) capillary-based micro-cooler degraded compared to previous demonstration of the technology for a heated area of 5 by 5 square millimeter, preliminary computational fluid dynamics (CFD) modeling indicates that an improved manifold design will be able to achieve comparable performance.

capillary flow↗

High-frequency electrical behavior in V 3 O 5 thin films

Vanadium oxides are known for their metal–insulator transition (MIT), with V 3 O 5 being notable for its transition temperature exceeding room temperature. At about 430 K, this material shows a change in crystal symmetry accompanied with one order of magnitude increase in its electrical conductivity and alterations in its optical properties. Although the property changes during the MIT in V 3 O 5 are less pronounced than those observed in VO 2 , its transition temperature is 90 K higher, making it appealing for applications requiring elevated temperatures. In this article, the high-frequency characteristics were determined in a V 3 O 5 two-terminal device in the range from 5 to 35 GHz. The S-parameters showed that the return loss at room temperature was close to −1.5 dB, and the isolation between ports was approximately −50 dB. At temperatures above the metal–insulator transition, the isolation decreased to around −40 dB at 35 GHz. For S11 and S22, similar behavior was observed at room temperature, with a notable change in the S-parameter phase of the device. This behavior suggests that V 3 O 5 may function well as a capacitor because the considerable change in phase could control the flow of electrical signals in devices. This property also may be used for matching purposes, especially considering its response to temperature changes. Additionally, conductivity calculation from S-parameters shows a decrease of approximately two orders of magnitude at 500 K and one order of magnitude at 300 K compared to DC values. These findings highlight V 3 O 5 potential for integration into radio frequency devices that demand consistent performance in high-temperature environments.

36 MATERIALS SCIENCE↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Identifying the Growth Phase of Magnetic Reconnection Using Pressure‐Strain Interaction

Abstract Magnetic reconnection often initiates abruptly and then rapidly progresses to a nonlinear quasi‐steady state. While satellites frequently detect reconnection events, ascertaining whether the system has achieved steady‐state or is still evolving in time remains challenging. Here, we propose that the relatively rapid opening of the reconnection separatrices within the electron diffusion region serves as an indicator of the growth phase of reconnection. The opening of the separatrices is produced by electron flows diverging away from the neutral line downstream of the X‐line and flowing around a dipolarization front. This flow pattern leads to characteristic spatial structures in the electron pressure‐strain interaction that could be a useful indicator for the growth phase of a reconnection event. We employ two‐dimensional particle‐in‐cell numerical simulations of anti‐parallel magnetic reconnection to validate this prediction. We find that the signature discussed here, alongside traditional reconnection indicators, can serve as a marker of the growth phase. This signature is potentially accessible using multi‐spacecraft single‐point measurements, such as with NASA's Magnetospheric Multiscale satellites in Earth's magnetotail. Applications to other settings where reconnection occurs are also discussed.

Barbhuiya, M. Hasan [Department of Physics and Ast↗

Thermal Gradient Effects on Redox Evolution and Volatility-Driven Fractionation in Ternary U/Ce/Cs Condensates

Understanding how thermal history influences redox evolution and chemical fractionation is essential for characterizing high-temperature condensation in complex materials, including nuclear debris. Here, we tested the hypothesis that distinct thermal regimes in a plasma flow reactor influence redox pathways and elemental partitioning in ternary U/Ce/Cs systems. A configurable plasma flow reactor was modified with an external tube furnace to impose two distinct thermal gradients: continuous ambient cooling and a furnace-assisted thermal hold-up near 1400 K followed by rapid cooling. Transmission electron microscopy characterized phase identity, morphology, and nanoscale element distributions, while inductively coupled plasma-mass spectrometry quantified bulk elemental ratios. Across both thermal regimes, uranium and cerium condensed as UO 2 and CeO 2 as dominant refractory oxide products. Uranium partially oxidized to α-UO 3 during extended ambient cooling, while furnace-assisted hold-up preserved UO 2 and produced partial reduction of cerium to Ce 2 O 3 . Cesium remained volatile upstream and condensed later in the reactor, forming Cs 2 O and Cs-uranate phases with the highest incorporation after thermal hold-up. Bulk ICP-MS measurements supported these observations. U/Ce ratios remained comparatively stable and Cs displayed delayed and apparent transient enrichment that matched the nanoscale measurements. This integrated approach provides a quantitative method for linking thermal gradients to redox evolution and volatility-driven fractionation. These results show how the plasma flow reactor can identify where equilibrium descriptions remain adequate and where kinetic effects from residence time and temperature history must be considered when interpreting condensation behavior in multicomponent systems.

and nuclear chemistry↗

Comparison of URANS and LES predictions for the open phase of the OECD NEA CSNI fluid structure interaction CFD benchmark

The OECD NEA CSNI WGAMA CFD Task Group ran a benchmark in 2020 and 2021 to assess the predictive capabilities of coupled fluid structure interaction (FSI) CFD analysis methods. This paper presents the predictions made for the open phase of the benchmark using URANS and LES turbulence modelling approaches, and a comparison of the results to the experimental data. The benchmark comprised a channel containing two inline cylinders in cross-flow. The cylinders were fixed at one end, free at the other, and had measured resonant frequencies and damping properties. The URANS modelling used ANSYS Fluent 2-way coupled to ANSYS Mechanical. The LES modelling used Nek5000, 1-way coupled to Diablo. Comparisons with cross-channel velocity profiles are presented, both for the mean flow and its RMS. Comparisons are also made to the frequency spectra for point measurements of fluid velocity and pressure, and for the accelerations of the free end of each cylinder. URANS predicts the average velocity profiles relatively well, and is able to predict the velocity and acceleration spectra at the shedding frequency. However, the frequency content at the 4th harmonic of the shedding frequency is low in the URANS flow fields, and so does not excite accelerations at the resonant frequency of the cylinders. LES makes better predictions of the average profiles, and the velocity spectra agree well at both the shedding frequency and at higher frequencies. In conclusion, the 1-way coupled LES results show good agreement for acceleration spectra.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Combining Distributed Electrochemical Measurements with a Semi-Empirical Model to Identify Local Variations in Overpotentials for PEM Water Electrolyzers

Abstract A segmented cell and PCB approach was used to demonstrate an advanced technique for measuring and understanding the electrochemical behavior of PEM water electrolyzers. By employing a semi-empirical model, discrete modes of overpotential and their spatial distributions were identified in an operating cell. Distributed area-specific resistance (DASR measurements indicate that local dehydration of the polymer electrolyte membrane is the primary driver of increased polarization, behaving similarly to mass transport-limited currents at low flow rates due to ineffective gas-phase bubble removal. To improve quantification, the overall ohmic overpotential is divided into background (η Ohm,b ) and mass transport-coupled (η Ohm,mt ) components. Two types of anode diffusion media, a baseline PTL and a thin foil liquid/gas diffusion layer (LGDL), were examined. The results show significant variations in η Ohm,b and highlight that ineffective bubble removal leads to pronounced local dehydration. The effect of cell temperature on various overpotentials was also examined. Negligible differences in diffusion overpotential were observed when comparing PEWE performance using the PTL and LGDL, despite major differences in two-phase fluid transport within each diffusion media. This underscores the critical role of the catalyst layer's micro-porous structure in diffusion processes. The study highlights the complex nature and intricacies of mass transport limitations within PEWEs.

Roy, Anirban (ORCID:0000000163803386)↗

Multiscale characterization of phase change materials for building thermal energy storage applications

Phase change materials (PCMs) store and release large amounts of thermal energy because of their high latent energy storage capacity. However, long-term cyclic stability, supercooling and performance-scalability are some of the major challenges for their use in building thermal energy storage (TES) applications. Here, in this study, we present a comprehensive multiscale characterization of two commercially available organic PCMs, Puretemp 18 and Puretemp 23. At the microscale, differential scanning calorimetry (DSC) was used to characterize phase change temperature, specific heat, and latent heat. At the mesoscale, a heat flow meter apparatus (HFMA), following the ASTM C1784 standard, was employed to measure the phase change temperature, specific heat, and latent heat properties. A comparative analysis of latent heat as a function of temperature was conducted by integrating the DSC and HFMA results. At the macroscale, the thermal performance and cyclic stability of the TES system was evaluated using Puretemp 23. The TES system consisted of a finned tube heat exchanger with a storage volume of 0.0189 m 3 (5 gal), which represents a compact, real-world TES solution suitable for building energy storage. The results showed consistent thermal stability of the PCM over 200 cycles, and the supercooling temperature remained within 0.2 °C, which was not detected in smaller-scale characterization methods. Additionally, the macroscale testing methodology of the PCM revealed that the TES is able to charge and discharge stored latent energy within 2 h under a temperature differential of 16.67 °C measured between the inlet water temperature and the phase transition temperature of the PCM. The proposed multiscale PCM characterization method provides a systematic basis for comparing important thermal storage properties while also investigating the scalability, reliability and integration challenges in large scale TES applications.

Latent heat↗

Modeling and Optimization of a Rotating Packed Bed Contactor with a Tetraamine-Appended Metal−Organic Framework for CO 2 Capture

A potential contactor technology for sorbent-based CO 2 capture is the rotating packed bed that contains separate sections for continuous adsorption and desorption. A heat exchanger can be embedded to remove heat in the adsorption section and add heat in the desorption section. In this work, we develop a two-dimensional (2D) model of a rotating packed bed for use in CO 2 capture applications. Mass and energy balances for the model are developed based on a Ljungström-type air preheater, which accounts for the counter-current axial flow of gas phases in separate sections of the bed and the rotation of a solid sorbent, which cycles between adsorption and desorption sections. The sorbent used for this analysis is the tetraamine-appended metal−organic framework Mg 2 (dobpdc)(3−4− 3), chosen for its stability and affinity for CO 2 at low partial pressures, such as those from a natural gas power plant source. An optimization problem is solved that considers the trade-off between maximizing the productivity of the bed and minimizing energy consumption. Maximum productivity and minimum energy are found to be 8.53 kg/h/m 3 and 3.84 MJ/kg, respectively, when these objectives are optimized independently. It is observed that the flue gas pressure and bed rotational speed are the desired operating variables to vary for model-based design of experiments to reduce uncertainty in parameter estimation, as these two variables yielded the most information content based on the Fisher information matrix.

20 FOSSIL-FUELED POWER PLANTS↗

Phase separation, edge currents, and Hall effect for active matter with Magnus dynamics

Here we examine run-and-tumble disks in two-dimensional systems where the particles also have a Magnus component to their dynamics. For increased activity, we find that the system forms a motility-induced phase-separated (MIPS) state with chiral edge flow around the clusters, where the direction of the current is correlated with the sign of the Magnus term. The stability of the MIPS state is non-monotonic as a function of increasing Magnus term amplitude, with the MIPS region first extending down to lower activities followed by a break up of MIPS at large Magnus amplitudes into a gel-like state. We examine the dynamics in the presence of quenched disorder and a uniform drive and find that the bulk flow exhibits a drive-dependent Hall angle. This is a result of the side jump effect produced by scattering from the pinning sites and is similar to the behavior found for skyrmions in chiral magnets with quenched disorder.

97 MATHEMATICS AND COMPUTING↗

A Kinetic Model of the Long-Term Corrosion of Glass-Ceramic Materials

Multiphase waste forms show promise for increased waste loading and for the ability to dispose of contaminated solid and particulate waste through direct densification. However, achieving predictive capability for long-term durability of multiphase waste forms, and thus assessing their possible deployment, requires expanding the current, limited knowledge base. Here, we describe the development of a corrosion model of a two-phase waste form consisting of crystals of known volume fraction embedded in a glass matrix. This model accounts for the dissolution of both the crystalline and glass phases as well as the hydration of the glass phase through an ion exchange reaction. Because of the large difference in solubility between the two phases, the reactive surface of the crystalline phase is a function of the extent of dissolution of the glass phase in this model. Model parameterization was performed using corrosion data, such as from single-pass flow-through tests, for the individual phases. The parameterized corrosion model was evaluated against static dissolution test data for a glass-ceramic multiphase waste form. This evaluation demonstrated the model’s ability to reproduce the time-dependent release of key tracers of glass and crystalline phase dissolution. Hence, the development of a kinetic model provides a pathway for long-term durability predictions and thus the use of multiphase waste forms in nuclear cleanup missions.

Kerisit, Sebastien N.↗

Saturation of fishbone instability through zonal flows driven by energetic particle transport in tokamak plasmas

Gyrokinetic and kinetic-MHD simulations are performed for the fishbone instability in the DIII-D discharge #178631, chosen for validation of first-principles simulations to predict the energetic particle (EP) transport in an ITER prefusion baseline scenario. Fishbone modes are found to generate zonal flows, which dominate the fishbone saturation. The underlying mechanisms of the two-way fishbone-zonal flows nonlinear interplay are discussed in details. Numerical and analytical analyses identify the fishbone-induced EP redistribution as the dominant generation mechanism for zonal flows. The zonal flows modify the nonlinear dynamics of phase space zonal structures, which reduces the amount of EPs able to resonate with the mode, leading to an early fishbone saturation. Simulation results including zonal flows agree quantitatively with DIII-D experimental measurements of the fishbone saturation amplitude and EP transport, supporting this novel saturation mechanism by self- generated zonal flows. Moreover, the wave-particle mode-locking mechanism is shown to determine quantitatively the fishbone frequency down-chirping, as evident in GTC simulation results in agreement with predictions from analytical theory. Finally, the
fishbone-induced zonal flows are possibly responsible for the formation of an ion-ITB in the DIII-D discharge. Based on the low EP transport and the large zonal flow shearing rates associated with the fishbone instability in gyrokinetic simulations of the ITER scenario, it is conjectured that high performance scenarios could be designed in ITER burning plasmas through fishbone-induced ITBs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Active nematic ratchet in asymmetric obstacle arrays

We numerically investigate the effect of an asymmetric periodic obstacle array in a two-dimensional active nematic. We find that activity in conjunction with the asymmetry leads to a ratchet effect or unidirectional flow of the fluid along the asymmetry direction. The directional flow is still present even in the active turbulent phase when the gap between obstacles is sufficiently small. We demonstrate that the dynamics of the topological defects transition from flow mirroring to smectic-like as the gap between obstacles is made smaller, and explain this transition in terms of the pinning of negative winding number defects between obstacles. This also leads to a nonmonotonic ratchet effect magnitude as a function of obstacle size, so that there is an optimal obstacle size for ratcheting at fixed activity.

36 MATERIALS SCIENCE↗

Active Nematic Ratchet in Asymmetric Obstacle Arrays

We numerically investigate the effect of an asymmetric periodic obstacle array in a two-dimensional active nematic. We find that activity in conjunction with the asymmetry leads to a ratchet effect or unidirectional flow of the fluid along the asymmetry direction. The directional flow is still present even in the active turbulent phase when the gap between obstacles is sufficiently small. We demonstrate that the dynamics of the topological defects transition from flow-mirroring to smectic-like as the gap between obstacles is made smaller, and explain this transition in terms of the pinning of negative winding number defects between obstacles. This also leads to a non-monotonic ratchet effect magnitude as a function of obstacle size, so that there is an optimal obstacle size for ratcheting at fixed activity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗