Non-destructive ultrasonic measurements of case depth

Two ultrasonic methods for nondestructive measurements of the depth of a case-hardened layer in steel are described. One method involves analysis of ultrasonic waves diffused back from the bulk of the workpiece. The other method involves finding the speed of propagation of ultrasonic waves launched on the surface of the work. Procedures followed in the two methods for measuring case depth are described.

Flambard, C.↗

Microcracking in Composite Laminates: Simulation of Crack-Induced Ultrasound Attenuation

Microcracking in composite laminates is a known precursor to the growth of inter-ply delaminations and larger scale damage. Microcracking can lead to the attenuation of ultrasonic waves due to the crack-induced scattering. 3D elastodynamic finite integration technique (EFIT) has been implemented to explore the scattering of ultrasonic waves due to microcracks in anisotropic composite laminates. X-ray microfocus computed tomography data was directly input into the EFIT simulation for these purposes. The validated anisotropic 3D EFIT code is shown to be a useful tool for exploring the complex multiple-scattering which arises from extensive microcracking.

Leckey, C. A. C.↗

Nanoscale Subsurface Imaging via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A novel scanning probe microscope methodology has been developed that employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by the fundamental resonance frequency of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever fundamental resonance. The resonance-enhanced difference-frequency signals are used to create images of embedded nanoscale features.

Cantrell, Sean A.↗

Resonant difference-frequency atomic force ultrasonic microscope

A scanning probe microscope and methodology called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope, driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever, engages the sample top surface. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave in the region defined by the cantilever tip-sample surface interaction force generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create images of nanoscale near-surface and subsurface features.

Cantrell, John H.↗

Pulsed-echo interface wave characterization of bolted plates

Ultrasonic waves which propagate along the plane boundary separating two solid substrates were used to characterize aluminum and titanium plates adhesively bonded and bolted together. Wave pulses were used to produce interface waves between the aluminum and a Ti-6Al-4V titanium alloy bar by normal mode conversion. Interface wave reflections from bolt holes drilled through the interface were reconverted to surface wave pulses and detected by the same wedge by standard pulse-echo techniques. Time of flight measurements indicate that the reflected waves are a supersonic of longitudinal modes and circularly symmetric waves that propagate around the bolt hole.

Turner, T. M.↗

Wire Crimp Connectors Verification using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp connections is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp connector and wire is shown to correlate with the results of a destructive pull test, which previously has been used to assess crimp wire junction quality. Various crimp junction pathologies (missing wire strands, incorrect wire gauge, incomplete wire insertion in connector) are ultrasonically tested, and their results are correlated with pull tests. Results show that the ultrasonic measurement technique consistently (as evidenced with pull-testing data) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying the technique while wire crimps are installed is also presented.

Cramer, K. Elliott↗

Wire Crimp Termination Verification Using Ultrasonic Inspection

The development of a new ultrasonic measurement technique to quantitatively assess wire crimp terminations is discussed. The amplitude change of a compressional ultrasonic wave propagating through the junction of a crimp termination and wire is shown to correlate with the results of a destructive pull test, which is a standard for assessing crimp wire junction quality. Various crimp junction pathologies such as undercrimping, missing wire strands, incomplete wire insertion, partial insulation removal, and incorrect wire gauge are ultrasonically tested, and their results are correlated with pull tests. Results show that the nondestructive ultrasonic measurement technique consistently (as evidenced with destructive testing) predicts good crimps when ultrasonic transmission is above a certain threshold amplitude level. A physics-based model, solved by finite element analysis, describes the compressional ultrasonic wave propagation through the junction during the crimping process. This model is in agreement within 6% of the ultrasonic measurements. A prototype instrument for applying this technique while wire crimps are installed is also presented. The instrument is based on a two-jaw type crimp tool suitable for butt-splice type connections. Finally, an approach for application to multipin indenter type crimps will be discussed.

Perey, Daniel F.↗

Nanoscale Subsurface Imaging of Nanocomposites via Resonant Difference-Frequency Atomic Force Ultrasonic Microscopy

A scanning probe microscope methodology, called resonant difference-frequency atomic force ultrasonic microscopy (RDF-AFUM), has been developed. The method employs an ultrasonic wave launched from the bottom of a sample while the cantilever of an atomic force microscope engages the sample top surface. The cantilever is driven at a frequency differing from the ultrasonic frequency by one of the contact resonance frequencies of the cantilever. The nonlinear mixing of the oscillating cantilever and the ultrasonic wave at the sample surface generates difference-frequency oscillations at the cantilever contact resonance. The resonance-enhanced difference-frequency signals are used to create amplitude and phase-generated images of nanoscale near-surface and subsurface features. RDF-AFUM phase images of LaRC-CP2 polyimide polymer containing embedded nanostructures are presented. A RDF-AFUM micrograph of a 12.7 micrometer thick film of LaRC-CP2 containing a monolayer of gold nanoparticles embedded 7 micrometers below the specimen surface reveals the occurrence of contiguous amorphous and crystalline phases within the bulk of the polymer and a preferential growth of the crystalline phase in the vicinity of the gold nanoparticles. A RDF-AFUM micrograph of LaRC-CP2 film containing randomly dispersed carbon nanotubes reveals the growth of an interphase region at certain nanotube-polymer interfaces.

Cantrell, Sean A.↗

Broadband electrostatic acoustic transducer for liquids

Capacitive electrostatic transducer (ESAT) measures absolute displacement amplitudes of ultrasonic waves in liquids, and may be used as calibrator for other transducers or as probe for nondestructive study and characterization of materials. ESAT consists of thin conductive membrane stretched over metallic housing. Ultrasonic waves incident on membrane cause it to vibrate and generate signal proportional to wave amplitude. Entire assembly is sealed for immersion in liquid.

Cantrell, J. H.↗

Ultrasonic nondestructive materials characterization

A brief review of ultrasonic wave propagation in solid materials is presented with consideration of the altered behavior in anisotropic and nonlinear elastic materials in comparison with isotropic and linear elastic materials. Some experimental results are described in which ultrasonic velocity and attenuation measurements give insight into materials microstructure and associated mechanical properties. Recent developments with laser beam non-contact generation and detection of ultrasound are presented. The results of several years of experimental measurements using high-power ultrasound are discussed, which provide substantial evidence of the inability of presently accepted theories to fully explain the interaction of ultrasound with solid materials. Finally, a special synchrotron X-ray topographic system is described which affords the possibility of observing direct interaction of ultrasonic waves with the microstructural features of real crystalline solid materials for the first time.

Green, R. E., Jr.↗

Attenuation of ultrasonic interface waves on metal-polymer-metal boundaries

The measured sensitivity of interface wave attenuation to defects near the bondline and to variations in the viscosity of the adhesive layer was compared with theoretical changes predicted by the Rokhin model. Differential interferometric optical measurements of interface wave attenuation due to defects near glass polymer metal boundaries are discussed. Pitch catch and pulse echo methods which use variable angle wedge transducers to generate and receive modified interface waves and to measure large bondline defects and adhesive viscosity are described.

Claus, R. O.↗

Method and System for Multi-Path Active Defect Detection, Localization and Characterization with Ultrasonic Guided Waves

A method and system of detecting, localizing, and characterizing a defect at one or more spatial points of interest on a structure. The method may include collecting first data in a first state using one or more transducers on the structure, collecting second data in a second state subsequent to the first state, computing a scattered impulse response based on the collected first data and the collected second data, comparing the scattered impulse response with an estimated scattered impulse response corresponding to the case when damage is present at one or more spatial points of interest on the structure, and combining the generated comparison results to detect, localize, and characterize a defect at the one or more spatial points of interest on the structure.

Hall, James Stroman↗

Ultrasonic Lamb Wave Inspection of Composite Defects

Composites have been extensively used in aerospace engineering due to their advantages of light weight, high strength, and engineering design flexibility. Manufacturing defects such as wrinkle and porosity can affect the performance of the composites and may lead to failure in the end, while damage such as delamination, fiber fraction, and matrix cracking can directly cause failure of the composites. In this paper, a Lamb wave based nonintrusive nondestructive evaluation system, which employs piezoelectric transducer for actuation and scanning laser Doppler vibrometer for wavefield sensing, is presented for typical composite defect and damage inspection and evaluation. Two composite panels with different geometry (flat or curved) and with various embedded defects (wrinkle and delamination) are inspected using the nonintrusive Lamb wave system. Both the wrinkles and delamination are detected from the wavefield and approximately quantified through wavefield imaging methods.

Wrinkles↗

Improved formula for continuous-wave measurements of ultrasonic phase velocity

An improved formula for continuous-wave ultrasonic phase velocity measurements using contact transducers is derived from the transmission line theory. The effect of transducer-sample coupling bonds is considered for measurements of solid samples even though it is often neglected because of the difficulty of accurately determining the bond thickness. Computer models show that the present formula is more accurate than previous expressions. Laboratory measurements using contacting transducers with the present formula are compared to measurements using noncontacting (hence effectively correction-free) capacitive transducers. The results of the experiments verify the validity and accuracy of the new formula.

Chern, E. J.↗

Nonlinear Ultrasonic Characterization of Fatigue Microstructures

Dislocation dipole substructures formed during metal fatigue are shown to produce a substantial distortion of ultrasonic waves propagating through the fatigued material. A model of ultrasonic wave-dislocation dipole interactions is developed that quantifies the wave distortion by means of a material nonlinearity parameter (beta). Application of the model to AA2024-T4 predicts a value of p approximately 300% larger in material cyclically loaded for 100 kcycles in stress-control at 276 MPa and R=0 than that measured for virgin material. Experimental measurements show a monotonic increase in p as a function of the number of fatigue cycles that closely approaches the predicted increase. The experiments also suggest that the relevant dislocation substructures are localized in the material.

Cantrell, John H.↗