Search NASA⌕ Search

SEARCH · Search NASA

Results for “UV radiation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Ionizing-radiation beamline monitoring system

Embodiments are directed generally to an ionizing-radiation beamline monitoring system that includes a vacuum chamber structure with vacuum compatible flanges through which an incident ionizing-radiation beam enters the monitoring system. Embodiments further include at least one scintillator within the vacuum chamber structure that can be at least partially translated in the ionizing-radiation beam while oriented at an angle greater than 10 degrees to a normal of the incident ionizing-radiation beam, a machine vision camera coupled to a light-tight structure at atmospheric/ambient pressure that is attached to the vacuum chamber structure by a flange attached to a vacuum-tight viewport window with the camera and lens optical axis oriented at an angle of less than 80 degrees with respect to a normal of the scintillator, and at least one ultraviolet (“UV”) illumination source facing the scintillator in the ionizing-radiation beam for monitoring a scintillator stability comprising scintillator radiation damage.

Friedman, Peter S.↗

Assessing the sources of reionization: a spectroscopic case study of a 30× lensed galaxy at z ~ 5 with Ly α , C IV, Mg ιι, and [Ne ιιι]

We present a detailed spectroscopic analysis of a galaxy at z ≃ 4.88 that is, by chance, magnified ~30× by gravitational lensing. Only three sources at z ≳ 5 are known with such high magnification. This particular source has been shown to exhibit widespread, high equivalent width ${{\rm C\, \small {IV}}}\ \lambda 1549\, \mathring{\rm A}$ emission, implying it is a unique example of a metal-poor galaxy with a hard radiation field, likely representing the galaxy population responsible for cosmic reionization. Using ultraviolet (UV) nebular line ratio diagnostics, Very Large Telescope (VLT)/X-shooter observations rule out strong active galactic nuclei (AGN) activity, indicating a stellar origin of the hard radiation field instead. We present a new detection of ${[{\rm Ne\, \small {III}}]}\ \lambda 3870\, \mathring{\rm A}$ and use the [${\rm Ne\, \small {III}}$]/[${\rm O\, \small {II}}$] line ratio to constrain the ionization parameter and gas-phase metallicity. Closely related to the commonly used [${\rm O\, \small {III}}$]/[${\rm O\, \small {II}}$] ratio, our [${\rm Ne\, \small {III}}$]/[${\rm O\, \small {II}}$] measurement shows this source is similar to local ‘Green Pea’ galaxies and Lyman-continuum leakers. It furthermore suggests this galaxy is more metal poor than expected from the fundamental metallicity relation, possibly as a consequence of excess gas accretion diluting the metallicity. Finally, we present the highest redshift detection of ${{\rm Mg\, \small {II}}}\ \lambda 2796\, \mathring{\rm A}$, observed at high equivalent width in emission, in contrast to more evolved systems predominantly exhibiting ${\rm Mg\, \small {II}}$ absorption. Strong ${\rm Mg\, \small {II}}$ emission has been observed in most z ~ 0 Lyman-continuum leakers known and has recently been proposed as an indirect tracer of escaping ionizing radiation. In conclusion, this strongly lensed galaxy, observed just $300\, \mathrm{Myr}$ after reionization ends, enables testing of observational diagnostics proposed to constrain the physical properties of distant galaxies in the James Webb Space Telescope (JWST)/Extremely Large Telescope (ELT) era.

79 ASTRONOMY AND ASTROPHYSICS↗

Radiation detectors employing contemporaneous detection and decontamination

Radiation detectors and methods of using the radiation detectors that provide a route for surface decontamination during use are described. The detectors utilize light illumination of an internal surface during use. Light is in the longer UV to near-infrared spectra and desorbs contamination from internal surfaces of radiation detectors. The methods can be carried out while the detectors are in operation, preventing the appearance of the negative effects of radioactive and non-radioactive contamination during a detection regime and following a detection regime.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of effects from gamma, e-beam and X-ray radiation on multilayer polymer films used in biopharmaceutical devices by chemometric treatment of spectroscopic data

The present study investigated the effects of gamma-ray, electron beam, and X-ray radiation on polymers in EVA/EVOH/EVA multilayer films. Spectroscopic methods, including FTIR and UV–Vis, were employed in conjunction with chemometric treatments such as PCA, SIMPLISMA treatments, and PLS models. The feasibility of dose prediction on multilayer film, given a known dose, is attainable across various irradiation technologies. Both gamma ray and X-ray exhibit comparable effects on the multilayer film, and it is feasible to anticipate the dose released on the film by utilizing UV–Vis spectra or infrared spectra for gamma ray or X-ray of a predetermined dose.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Characterization of proton-induced damage in thick, p-channel skipper-CCDs

Here, in this work, we characterize the radiation-induced damage in two thick, p-channel skipper-CCDs irradiated unbiased and at room temperature with 217-MeV protons. We evaluate the overall performance of the sensors and demonstrate their single-electron/single-photon sensitivity after receiving a fluence on the order of 10 10 protons/cm 2 . Using the pocket-pumping technique, we quantify and characterize the proton-induced defects from displacement damage. We report an overall trap density of 0.134 traps/pixel for a displacement damage dose of 2.3 × 10 7 MeV/g. Three main proton-induced trap species were identified, V 2 , C i O i and V n O m , and their characteristic trap energies and cross sections were extracted. We found that while divacancies are the most common proton-induced defects, C i O i defects have a greater impact on charge integrity at typical operating temperatures because their emission-time constants are comparable or larger than typical readout times. To estimate ionization damage, we measure the characteristic output transistor curves. We found no threshold voltage shifts after irradiation. Our results highlight the potential of skipper-CCDs for applications requiring high-radiation tolerance and can be used to find the operating conditions in which effects of radiation-induced damage are mitigated.

47 OTHER INSTRUMENTATION↗

Value Proposition of UV-Absorbers in PV Module Encapsulation

Various common crystalline silicon cell technologies were exposed to UVA radiation (1.24 Wm-2 nm-1 at 340 nm peak) on the front and back faces at 45 degrees Celsius for periods up to 3000 h, representing about 3 y of solar exposure in Phoenix, Arizona, USA. The resulting degradation of the open-circuit voltage and short-circuit current is presented. Of the various cell types examined, significant levels of degradation were seen in all cases. Less degradation was generally found after UV irradiation of cell fronts and older cell types, whereas a bifacial PERC type exposed on the rear showed about 25% degradation in short circuit current, attributable to lack of a diffused surface field. Selected cells were exposed to UV irradiation with the addition of long pass UV filters to replicate UV-absorbers in encapsulants. Modern cell designs are sensitive to UV-ID because of reduced or eliminated front and back surface field and increased dependence on high quality surface passivation. Single transformation of the independent variable (t, kW h/m^2) could be used to achieve a linear model of the data to extrapolate to 50 y. Solar Advisor Model (SAM) shows appropriate filtering of UV-irradiation can improve LCOE and net present value of plant. Some advanced cell types are seen to be UV-resistant (cell level solutions also exist). Solutions therefore exist on the cell, glass, and encapsulant level. Changes over time in each of these would also need to be considered (solarization, encapsulant browning...).

ENGINEERING,SOLAR ENERGY↗

Characterizing Radiation-Induced Chromium Redox Chemistry

The redox behavior of Cr(III) and Cr(VI) in nuclear environments were studied by analyzing aqueous irradiated chromium ions using UV-Visible spectroscopy. The formation of different chromium oxidation states can occur through gamma radiolysis of chromium solutions. Characterization of radiation-induced chromium is not well understood, and yet important as chromium can make its way into the primary coolant of reactors because of the corrosion of stainless steel reactor components. Furthermore, Cr(VI) is toxic and not suitable for environmental release, therefore Cr speciation is important. Fricke dosimetry was performed to collect doses rates, specific extinction coefficients were obtained from various analytical methods for the two oxidation states of chromium. Chromium samples--conditioned at various pH's and concentration to understand the effects--were then irradiated using a Coblat-60 gamma irradiator. Three optical spectroscopy analytical methods were used , including direct oxidation state measurements and complexation by either EDTA or DPC. Complexation by EDTA was found to not be a reliable method. Radiolytic oxidation of Cr(III) to Cr(VI), and reduction of Cr(VI) to Cr(III) were clearly seen, except for Cr(III) samples were a pH less than or equal to 2, where no change occurred.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

BOSS quasar outflows traced by C iv

ABSTRACT We investigate possible factors that drive fast quasar outflows using a sample of 39 249 quasars at median redshift 〈z〉 ≈ 2.17. Unique to this study, the quasar redshifts are re-measured based on the Mg ii emission line, and explore unprecedented outflow velocities (>6000 km s−1), while maintaining statistical significance. We measure reliable C iv blueshifts for 1178 quasars with velocities >2500 km s−1. From those, 255(13) quasars have blueshifts above 4000(6000) km s−1, with the highest C iv velocity ≈7000 km s−1. Several correlations are observed, where higher C iv blueshifts in general are in quasars with broader, weaker C iv emission profiles, weak He ii emission, larger Eddington ratios, and bluer ultraviolet (UV) continuum slope across the rest-frame UV to near-infrared. Analysis reveals two primary factors contributing to faster outflows: higher Eddington ratios, and softer far-UV continuum (hν >24.6 eV). We find supporting evidence that radiative line driving may generate extreme outflow velocities, influenced by multiple factors as suggested by the aforementioned correlations. This evidence highlights the importance of considering a multidimensional parameter space in future studies when analyzing large C iv blueshifts to determine the fundamental causes of outflows.

Gillette, Jarred (ORCID:0000000185284839)↗

Quantum dot lightning detection and warning system and method

A quantum dot (QD) lightning detection and warning (LDW) system and method. This LDW system and method find broader applicability to spark and other transient optical event detection as well. The QDs are operable for receiving ultraviolet (UV), infrared (IR), visible, x-ray, and/or gamma ray radiation emanating from lightning or the like and generating visible radiation that may be detected and utilized to generate topological event information, such that property, human life, and the like may be safeguarded.

Bahritdinov, Farhod↗

Production and suppression of delayed light in NaI(Tl) scintillators

Here we investigate a hypothesis that energy accumulation and the subsequent release in NaI(Tl) may lead to pulselike events in the few-keV energy regime, a phenomenon suggested by the crystal manufacturing company Saint-Gobain, who provided the crystals for DAMA/LIBRA. While we observed delayed long-lasting (days) light emission in a 3-inch NaI(Tl) crystal after exposing it to UV light, the delayed light consists primarily of single photons that are uncorrelated with each other. We also observe delayed light emission in NaI(Tl) following gamma radiation and large ionization events like cosmic-ray muons. We found that irradiating the crystal with red light after UV exposure significantly suppressed delayed photon emissions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation-induced transients on solid and molten Li and K iodides

The study, quantification, and monitoring of iodine in nuclear power generation systems have been paramount due to its environmental and health implications. Thorough speciation and transport studies strengthened the development and deployment of water reactors, which are now required for the new generation of Molten Salt Reactors (MSR), where the fuel and coolant are a complex liquid system of suitable halides. The speciation, radiation-induced chemistry, and transport of iodine (I-127, I-129 and I-131) under extreme conditions of temperature and ionizing radiation are among the challenges for the future implementation of MSR’s. In aqueous systems, the triiodide-iodine-iodide (I3--I2-I-) equilibrium is strongly dependent on the conditions of the medium. In molten iodides and chlorides, the triiodide detection (and its disproportionation) poses challenges due to the extreme conditions of temperature and radiation, but studies have shown a dependence on temperature, absorbed dose and salt composition. Through absorption spectroscopy techniques (diffuse reflectance and high-temperature UV-Vis), as well as resonance (Electron Paramagnetic Resonance) it is possible to identify primary transients induced by ionizing radiation trapped in the solid phase (Solid-state radiolysis), and steady-state main absorption components with a fast-acquisition real-time spectroscopy. The presence of heterogeneous phase (colloids), viscosity changes, and gas evolution are among the observed processes. A specific case of study is speciation in the presence of Ni. A corrosion product with magnetic properties due to unpaired electrons in its electronic structure. Ferromagnetic materials are monitored in solidified salts to identify aggregation and phase separation. Comparative studies of eutectic mixtures of LiI-KI and LiCl-KCl with known addition of dopants will be presented, with a perspective of radiation chemistry and its possible implications in complex systems.

36 - MATERIALS SCIENCE↗

Full Device Evaluation of Metal Halide Perovskite Solar Cells in Low Earth Orbit Aboard the International Space Station

This study investigates how sustained low Earth orbit (LEO) exposure affects metal halide perovskite (MHP) thin films and perovskite solar cells (PSCs). It examines samples deployed on the Materials International Space Station Experiment (MISSE) 15 and 16 missions. Five methylammonium lead iodide (MAPI) thin films are deployed on MISSE-16, each with distinct UV filters to selectively attenuate AM0 spectral bands. While post-flight optical analysis reveals that the least UV-exposed film exhibits the highest emission and lowest non-radiative recombination rate, no clear correlation is observed among the rest, and all MAPI films maintained excellent integrity throughout the mission. MISSE-15 deployed eight PSCs with diverse structures, MHP compositions, and contact materials. Post-flight analysis reveals stable, highly emissive MHPs, but damaged contacts due to ion migration, which caused loss of electrical response. The MISSE missions demonstrate MHPs' suitability for space applications, while highlighting the need for improved interfacial layers and contact materials to enhance charge carrier mobility, prevent ion migration, and improve charge carrier extraction efficiency.

14 SOLAR ENERGY↗

Incident excitation effects on ZnO-based photoluminescence

Zinc oxide (ZnO) is an attractive semiconductor material owing to a wide band gap, large exciton binding energy, and strong luminescent properties. Two distinct spectral regions are present in the room temperature emission of this material: a narrow line in the UV/near-UV region that is excitonic in nature and a lower energy broad emission band centered in the green/yellow region. Commercially available ZnO particles containing excess Zn and oxygen vacancy defect sites (referred to as ZnO:Zn) were excited using three light sources to study different radiative recombination regimes of the as-received powders. First, a UV LED at a center wavelength of 365 nm provided low irradiance (0.02–0.08 W/cm 2 ) with varying pulse widths (continuous operation to 16 ns). Second, the third harmonic of a pulsed Nd:YAG laser provided high irradiances (∼10 4 –10 6 W/cm 2 ) at a fixed nominal pulse width of 5 ns. Finally, a continuous polychromatic synchrotron X-ray source was also used to excite the ZnO:Zn powders. During UV LED excitation, a low number of carriers are created in the material, leading to an anticipated linear relationship between luminescence and irradiance. This held true for defect luminescence; however, there was an observed enhancement of exciton emission relative to the UV LED intensity as the pulse width was decreased, independent of irradiance. During UV laser excitation, the number of carriers was significantly increased, raising the material into a bimolecular recombination regime, which produced exciton emission much stronger than visible band emission. Finally, spectra obtained during synchrotron X-ray excitation, whose continuous illumination and higher penetration depth yielded higher emission from defect sites relative to exciton emission. A redshift in the exciton emission was also observed as excitation pulse width and sample temperature were varied, and is discussed.

Westphal, Eric Robert [Sandia National Lab. (SNL-N↗

UV hybrid photon detector based on GaN photocathodes and Si low gain avalanche diode

Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.

47 OTHER INSTRUMENTATION↗

Design and implementation of a prototype infrared video bolometer (IRVB) in MAST Upgrade

A prototype infrared video bolometer (IRVB) was successfully deployed in the Mega Ampere Spherical Tokamak Upgrade (MAST Upgrade or MAST-U), the first deployment of such a diagnostic in a spherical tokamak. The IRVB was designed to study the radiation around the lower x-point, another first in tokamaks, and has the potential to estimate emissivity profiles with spatial resolution beyond what is achievable with resistive bolometry. The system was fully characterized prior to installation on MAST-U, and the results are summarized here. After installation, it was verified that the actual measurement geometry in the tokamak qualitatively matches the design; this is a particularly difficult process for bolometers and was done using specific features of the plasma itself. The installed IRVB measurements are consistent both with observations from other diagnostics, including magnetic reconstruction, visible light cameras, and resistive bolometry, as well as with the IRVB-designed view. Early results show that with conventional divertor geometry and only intrinsic impurities (for example, C and He), the progression of radiative detachment follows a similar path to that observed for large aspect ratio tokamaks: The peak of the radiation moves along the separatrix from the targets to the x-point and high-field side midplane with a toroidally symmetric structure that can eventually lead to strong effects on the core plasma inside the separatrix.

47 OTHER INSTRUMENTATION↗

Cosmic variance and the inhomogeneous UV luminosity function of galaxies during reionization

When the first galaxies formed and starlight escaped into the intergalactic medium to reionize it, galaxy formation and reionization were both highly inhomogeneous in time and space, and fully coupled by mutual feedback. To show how this imprinted the UV luminosity function (UVLF) of reionization-era galaxies, we use our large-scale, radiation-hydrodynamics simulation CoDa II to derive the time- and space-varying halo mass function and UVLF, from z ≃ 6–15. That UVLF correlates strongly with local reionization redshift: earlier-reionizing regions have UVLFs that are higher, more extended to brighter magnitudes, and flatter at the faint end than later-reionizing regions observed at the same z. In general, as a region reionizes, the faint-end slope of its local UVLF flattens, and, by z = 6 (when reionization ended), the global UVLF, too, exhibits a flattened faint-end slope, ‘rolling-over’ at M UV ≳ -17. CoDa II’s UVLF is broadly consistent with cluster-lensed galaxy observations of the Hubble Frontier Fields at z = 6–8, including the faint end, except for the faintest data point at z = 6, based on one galaxy at M UV = -12.5. According to CoDa II, the probability of observing the latter is $\sim 5~{{\ \rm per\ cent}}$. However, the effective volume searched at this magnitude is very small, and is thus subject to significant cosmic variance. Here, we find that previous methods adopted to calculate the uncertainty due to cosmic variance underestimated it on such small scales by a factor of 2–4, primarily by underestimating the variance in halo abundance when the sample volume is small.

79 ASTRONOMY AND ASTROPHYSICS↗

Photopolymerizable Sol-gel Synthesis for Faster Manufacturing of Surrogate Nuclear Debris

Simulated debris is used to train first responders for potential nuclear detonations. Sol gel chemistry has been used to produce surrogate material for these training exercises, but the current average production time is 4 hours. Optimization using UV-polymerizable sol gel precursors can potentially decrease time as well as cost of the production process. FT-IR spectroscopy was used to measure and compare gelation kinetics of the standard and photopolymerizable sol gel synthetic procedures. Addition of the UV-polymerizable precursors and controlling the aqueous phase volume resulted in a 120-fold decrease in vitrification time.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗