Search NASASearch

SEARCH · Search NASA

Results for “Uncertainty Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Uncertainty Analysis for Oil-Film Interferometry Skin-Friction Measurement Techniques

Over the past 20 years, the use of oil-film interferometry to measure the skin friction coefficient (C(sub f) = tau/q where tau is the surface shear stress and q is the dynamic pressure) has increased. Different forms of this oil-film technique with various levels of accuracy and ease of use have been successfully applied in a wide range of flows. The method's popularity is growing due to its relative ease of implementation and minimal intrusiveness as well as an increased demand for C(sub f) measurements. Nonetheless, the accuracy of these methods has not been rigorously addressed to date. Most researchers have simply shown that the skin-friction measurements made using these techniques compare favorably with other measurements and theory, most of which are only accurate to within 5-20%. The use of skin-friction data in the design of commercial aircraft, whose drag at cruise is 50% skin-friction drag, and in the validation of computational fluid dynamics programs warrants better uncertainty estimates. Additional information is contained in the original extended abstract.

Naughton, Jonathan W.

Radiative Heating Indicators and Uncertainty Analysis for Mars 2020

This paper will present analysis to evaluate a functional form and associated parameters to determine the radiative heating at various back-shell locations of the Mars 2020 aeroshell. The radiative heating indicators are used for preliminary vehicle design, and to determine the worst-case trajectories for peak radiative heat flux and load. Historically, the functional form for radiative heating is based on free-stream parameters of density, velocity and a length scale, typically the nose-radius (or equivalent). However, a fit of this form has been shown to not provide significant enough accuracy when compared to simulation results. Therefore, a fit based on post-shock equilibrium calculations of CO and CO2 number density, temperature and pressure has been devised. The results from the TPS 15 01 trajectory were used to develop the fit. The fit was then applied to the MSL best estimated trajectory (BET). Furthermore, the paper will quantify the uncertainty in simulations of the radiative heating for Mars 2020.

Mars 2020

Coherent Uncertainty Analysis of Aerosol Measurements from Multiple Satellite Sensors

Aerosol retrievals from multiple spaceborne sensors, including MODIS (on Terra and Aqua), MISR, OMI, POLDER, CALIOP, and SeaWiFS altogether, a total of 11 different aerosol products were comparatively analyzed using data collocated with ground-based aerosol observations from the Aerosol Robotic Network (AERONET) stations within the Multi-sensor Aerosol Products Sampling System (MAPSS, http://giovanni.gsfc.nasa.gov/mapss/ and http://giovanni.gsfc.nasa.gov/aerostat/). The analysis was performed by comparing quality-screened satellite aerosol optical depth or thickness (AOD or AOT) retrievals during 2006-2010 to available collocated AERONET measurements globally, regionally, and seasonally, and deriving a number of statistical measures of accuracy. We used a robust statistical approach to detect and remove possible outliers in the collocated data that can bias the results of the analysis. Overall, the proportion of outliers in each of the quality-screened AOD products was within 12%. Squared correlation coefficient (R2) values of the satellite AOD retrievals relative to AERONET exceeded 0.6, with R2 for most of the products exceeding 0.7 over land and 0.8 over ocean. Root mean square error (RMSE) values for most of the AOD products were within 0.15 over land and 0.09 over ocean. We have been able to generate global maps showing regions where the different products present advantages over the others, as well as the relative performance of each product over different landcover types. It was observed that while MODIS, MISR, and SeaWiFS provide accurate retrievals over most of the landcover types, multi-angle capabilities make MISR the only sensor to retrieve reliable AOD over barren and snow / ice surfaces. Likewise, active sensing enables CALIOP to retrieve aerosol properties over bright-surface shrublands more accurately than the other sensors, while POLDER, which is the only one of the sensors capable of measuring polarized aerosols, outperforms other sensors in certain smoke-dominated regions, including broadleaf evergreens in Brazil and South-East Asia.

remote sensing

$\overline{TKE}$ Parameterization and $\bar{v}$ Uncertainty Analysis for CGMF

Previous work was performed on tuning CGMF parameters for 235 U, 238 U, and Plutonium isotopes. Now work is being done to tune minor uranium isotopes. However, uranium isotopes like 232 U and 236 U have almost no experimental data. We are applying cross-isotope models to extrapolate and tune CGMF on isotopes that lack experimental data. There exist several internal CGMF physics quantities that affect the output of CGMF—multi-chance fission probability, excitation energy sharing, spin-cutoff factor, spin scaling, and fragment total kinetic energy to name a few. The mean fragment total kinetic energy, $\overline{TKE}$, is particularly interesting because of its strong anti-correlation with $\bar{v}$. We are most interested in the mean fragment total kinetic energy before neutron emissions. $\overline{TKE}$ is assumed to be pre-neutron emission unless otherwise stated. Currently in CGMF, the $\overline{TKE}$ model for 233,234,235,238 U are tuned independently to reproduce ν for the associated isotopes. In this report, we will tune a cross-isotope $\overline{TKE}$ model to experimental $\overline{TKE}$ data for 232,233,234,235,236,238 U. Because of the unreliable and sparse nature of $\overline{TKE}$ experimental data, future work will use more reliable experimental $\bar{v}$ data to infer the $\overline{TKE}$ model (and likely other internal CGMF parameters) for uranium isotopes. Such work has been performed previously using a sensitivity analysis and Kalman filter methods.

07 ISOTOPE AND RADIATION SOURCES

Uncertainty Analysis of Stiffened Composite Panels

A study is made of the variability in the nonlinear response of three stiffened composite panels associated with variations in their geometric and material parameters. The three panels have a cylindrical skin with either four or five T-shaped stiffeners. Two of the panels have a notch and the third panel has a circular cutout. Hierarchical sensitivity analysis is used to identify the major parameters at the micro-mechanical, layer, laminate and sub-component levels. The major parameters are then taken to be fuzzy parameters, and a fuzzy set analysis is used to determine the range of variation of the response associated with pre-selected variations in the major parameters.

Noor, Ahmed K.

Uncertainty Analysis of Composite Structures

A two-phase approach and a computational procedure are presented for predicting the variability in the nonlinear response of composite structures associated with variations in the geometric and material parameters of the structure. In the first phase, hierarchical sensitivity analysis is used to identify the major parameters, which have the most effect on the response quantities of interest. In the second phase, the major parameters are taken to be fuzzy parameters, and a fuzzy set analysis is used to determine the range of variation of the response, associated with preselected variations in the major parameters. The effectiveness of the procedure is demonstrated by means of a numerical example of a cylindrical panel with four T-shaped stiffeners and a circular cutout.

Noor, Ahmed K.

Uncertainty Analysis of Coaxial Thermocouple Calorimeters Used in Arc Jets

Recent introduction of Coaxial Thermocouple type calorimeters into the NASA Ames arc jet facilities has inspired an analysis of 2D conduction effects internal to this type of calorimeter. The 1D finite slab inverse analysis (which is typically used to deduce the heat transfer to the calorimeter) relies on the assumption that lateral conduction (i.e., 2D effects) is negligible. Most calorimeter bodies have a spherical nose, which in itself is a violation of the 1D finite slab analysis assumption. Secondly most calorimeters experience a variation in heating across the face of the body which is also a violation of the 1D finite slab analysis assumption. It turns out that these two effects tend to cancel each other to some extent. This paper shows the extent to which error exists in the analysis of the Coaxial Thermocouple type calorimeters, and also offers analysis strategies for reducing the errors.

Lateral Conduction

Data Accountability and Uncertainty Analysis for the Mars Science Laboratory

This paper presents machine learning-based approaches to automate and optimize the detection of volume loss for the downlink process of telemetry data from the Mars Curiosity Rover. The Curiosity observes volume loss and data corruption, requiring re-transmits from the rover and Ground Data System Analysts (GDSA) to monitor the data flow. To resolve this issue, we created a data pipeline to accumulate data from various data sources in the downlink process and detect where the data is missed. In this paper, we benchmarked different methodologies based on the accuracy and excitability of them to identify whether a downlink data that is received to the ground system is complete or incomplete. Our results show that machine learning methods can improve the performance of the GDSA by 55% while the user can diagnose why data is missed and provide an explanation for the data accountability problem.

Chowdhury, Ameera