Search NASA⌕ Search

SEARCH · Search NASA

Results for “VIBRATION MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Shuttle's Vibration Environment is Compatible with the Oscillating Screen Viscometer

The oscillating screen viscometer is designed for useful operation in the vibration environment of the Space Shuttle. The following analysis compares recently analyzed on-orbit vibration data against the viscometer's measured vibration sensitivity. During routine crew activities the effect of the resulting vibration on the precision of the viscosity measurement will be tolerable. However, there is a possible problem if the astronauts use unisolated exercise equipment for extended periods of time.

Berg, Robert F.↗

Development and application of ride-quality criteria

Ride quality vibration criteria applicable to the design and evaluation of air and surface transportation systems are described. Consideration is given to the magnitude of vehicle vibration experienced by the passenger, the frequency of vibration, the direction of vibration measurements are presented for a variety of air and surface transportation systems. In addition, simulator data on seat dynamics and passenger response are presented. Results suggest the relative merits of various physical descriptors and measurement locations for characterizing the vibration in terms suitable for the design and/or evaluation of transportation systems.

Stephens, D. G.↗

Development and application of ride-quality criteria

A program for the development of ride-quality vibration criteria applicable to the design and evaluation of air and surface transportation systems is described. Consideration is given to the magnitude of vehicle vibration experienced by the passenger, the frequency of vibration, the direction of vibration, and the influence of seat dynamics on passenger response. Comparative vibration measurements are presented for a variety of air and surface transportation systems. In addition, simulator data on seat dynamics and passenger response are presented. Results suggest the relative merits of various physical descriptors and measurement locations for characterizing the vibration in terms suitable for the design and/or evaluation of transportation systems.

Stephens, D. G.↗

Multiple-Boundary-Condition Vibration Tests

Multiple-boundary-condition testing method technique to improve analysis of vibrations in large structures. Conceived for vibrational testing, in terrestrial environment, of large, complicated three-dimensional structures intended for use in outer space. Objective of such testing, to identify parameters of mathematical models used to predict vibrations of such structures in absence of gravitation and air. Structure supported and/or restrained at several positions; excited at desired vibrational frequencies, and vibrations measured to determine characteristics of vibrational modes. Potential terrestrial uses in testing and evaluation of dynamics of towers and offshore structures and safety of large buildings in Earthquakes.

Kuo, Chin-Po↗

STS-93 Flight Day 4 Highlights and Crew Activities

The five astronauts aboard the Space Shuttle Columbia began their fourth flight day preparing to make additional celestial observations through the shuttle's windows and continue work with a variety of instruments. Pilot Jeff Ashby and Mission Specialists Steve Hawley and Michael Tognini set up an exercise treadmill and the Treadmill Vibration Information System (TVIS) which measures vibrations and changes in microgravity levels caused by on-orbit workouts. Astronomer Hawley again made observations of Venus, Jupiter and the Moon with the Southwest Ultraviolet Imaging System (SWUIS) as Commander Eileen Collins and Pilot Jeff Ashby put the shuttle in the proper orientation for his observations. Tognini and Coleman checked the bioprocessing experiments, and harvested mouse-ear cress plants as part of the Plant Growth in Microgravity experiment. Collins and Ashby once again fired the shuttle's engines so that the sensors of the Midcourse Space Experiment (MSX) satellite were able to collect ultraviolet, infrared and visible light data. Columbia was orbiting at an altitude of 182 statute miles with all of its systems in excellent condition.

Source record↗

In-Flight Vibration Environment of the NASA F-15B Flight Test Fixture

Flight vibration data are analyzed for the NASA F-15B/Flight Test Fixture II test bed. Understanding the in-flight vibration environment benefits design and integration of experiments on the test bed. The power spectral density (PSD) of accelerometer flight data is analyzed to quantify the in-flight vibration environment from a frequency of 15 Hz to 1325 Hz. These accelerometer data are analyzed for typical flight conditions and maneuvers. The vibration data are compared to flight-qualification random vibration test standards. The PSD levels in the lateral axis generally are greater than in the longitudinal and vertical axes and decrease with increasing frequency. At frequencies less than approximately 40 Hz, the highest PSD levels occur during takeoff and landing. Peaks in the PSD data for the test fixture occur at approximately 65, 85, 105-110, 200, 500, and 1000 Hz. The pitch-pulse and 2-g turn maneuvers produce PSD peaks at 115 Hz. For cruise conditions, the PSD level of the 85-Hz peak is greatest for transonic flight at Mach 0.9. From 400 Hz to 1325 Hz, the takeoff phase has the highest random vibration levels. The flight-measured vibration levels generally are substantially lower than the random vibration test curve.

Corda, Stephen↗

Isolation and measurement of rotor vibration forces

Mounting for helicopter gearbox measures forces generated by rotor and isolates transmission from airframe. Mountings have frequency-dependent load/displacement relationship that gives statically rigid but dynamically soft support, lowering vibratory transfer. Previous isolation by springs or force-opposing devices required strain gages to measure rotor vibration and were operative at only one vibration frequency. Active system eliminates these limitations.

Kenigsberg, I.↗

Vibrational temperature from measurements of N2 and N2(+) shock layer radiation

Measurements of the vibrational temperature in a shock layer produced by a cylindrical blunt body in an arc jet nitrogen flow are made for both the neutral molecule and the molecular ion. Spectra were obtained at two locations in the shock layer produced by a 20-cm long cylindrical blunt body inserted in the arc jet conical flow. The technique used for determining the temperatures from the spectral radiation involves obtaining ratios of integrated intensities for certain spectral regions of the measured spectrum and making a comparison with computed ratios as a function of temperature for the same spectral regions. The technique is difficult to apply due to radiation overlapping bands from other species. However, using a trial and error procedure, the vibrational and rotational temperatures at the two locations are inferred. The results indicate that the shock layer is significantly out of thermal equilibrium.

Blackwell, Harvel E.↗

Measured rotational and vibrational temperature differences in arc jet shock layers

Shock-layer-radiation emission spectra from the first negative system of the nitrogen molecular ion N2(+) are analyzed over the wavelength region between 370 and 430 nm. The shock layer is produced by a blunt body placed in the expanded flow from an arc heater employing either pure nitrogen or a nitrogen-oxygen air mixture. A rotational temperature is obtained from analysis of (0,1) band emission from N2(+). Vibrational temperatures are extracted from population distributions obtained through spectral fitting of the N2(+) (B-X) band sequences. Rotational temperatures up to 9500 K near the front of the shocks are determined for different energy and flow conditions. The rotational temperatures are found to be lower than those obtained for vibration confirming previous measurements and contrary to expectation based on theory.

Blackwell, Harvel E.↗

A numerically exact description of ultrafast vibrational decoherence in vibration-coupled electron transfer

Broadband pump–probe spectroscopy has been widely used to measure vibrational decoherence associated with the reaction coordinate in photoinduced ultrafast vibration-coupled electron transfer (VCET) reactions. These experiments provide insight into the interplay of intramolecular coordinates along the reaction coordinate. However, a general theoretical foundation for analyzing, and even for explaining rigorously, these data is lacking. In this work, we study vibrational decoherence in a model VCET reaction using the nearly exact time-dependent density matrix renormalization group simulation method. We explore how analyzing the density matrix with quantum information measures can help elucidate the evolution of vibrational coherence in simulations of dynamics. We examine how vibrational coherence is affected by electron transfer on the timescale of approximately 100 femtoseconds. Our results suggest that electron transfer, in the nonadiabatic model, changes the vibrational equilibrium position abruptly—an example of a “quantum quench” event. This explains the concomitant vibrational decoherence. We find that abrupt vibrational decoherence can be mitigated by wavepacket motion occurring on the timescale of the electron transfer.

Science & Technology - Other Topics↗

Noncontacting measuring device to indicate deflection of turbopump internal rotating parts

Noncontacting, nondestructive techniques to measure vibrations and deflections of parts in future LOX and LH2 multistage turbopump prototypes are reported. The measurements include shaft vibration, vibration of turbine wheel and blades, blade clearance, vibration of impellers, value component flutter, and vibration of face seal components. Three techniques were selected for development: ultrasonic Doppler devices, flash X-ray, and light-pipe reflectance.

Hamilton, D. B.↗

Passive Wireless Vibration Sensing for Measuring Aerospace Structural Flutter

To reduce energy consumption, emissions, and noise, NASA is exploring the use of high aspect ratio wings on subsonic aircraft. Because high aspect ratio wings are susceptible to flutter events, NASA is also investigating methods of flutter detection and suppression. In support of that work a new remote, non-contact method for measuring flutter-induced vibrations has been developed. The new sensing scheme utilizes a microwave reflectometer to monitor the reflected response from an aeroelastic structure to ultimately characterize structural vibrations. To demonstrate the ability of microwaves to detect flutter vibrations, a carbon fiber-reinforced polymer (CFRP) composite panel was vibrated at various frequencies from 1Hz to 130Hz. The reflectometer response was found to closely resemble the sinusoidal response as measured with an accelerometer up to 100 Hz. The data presented demonstrate that microwaves can be used to measure flutter-induced aircraft vibrations.

Wilson, William C.↗

Evaluation of Standard Gear Metrics in Helicopter Flight Operation

Each false alarm made by a machine monitoring system carries a high price tag. The machine must be taken out of service, thoroughly inspected with possible disassembly, and then made ready for service. Loss of use of the machine and the efforts to inspect it are costly. In addition, if a monitoring system is prone to false alarms, the system will soon be turned off or ignored. For aircraft applications, one growing concern is that the dynamic flight environment differs from the laboratory environment where fault detection methods are developed and tested. Vibration measurements made in flight are less stationary than those made in a laboratory, or test facility, and thus a given fault detection method may produce more false alarms in flight than might be anticipated. In 1977. Stewart introduced several metrics, including FM0 and FM4, for evaluating the health of a gear. These metrics are single valued functions of the vibration signal that indicate if the signal deviates from an ideal model of the signal. FM0 is a measure of the ratio of the peak-to-peak level to the harmonic energy in the signal. FM4 is the kurtosis of the signal with the gear mesh harmonics and first order side bands removed. The underlying theory is that a vibration signal from a gear in good condition is expected to be dominated by a periodic signal at the gear mesh frequency. If one or a small number of gear teeth contain damage or faults, the signal will change, possibly showing increased amplitude, local phase changes or both near the damaged region of the gear. FM0 increases if a signal contains a local increase in amplitude. FM4 increases if a signal contains a local increase in amplitude or local phase change in a periodic signal. Over the years, other single value metrics were also introduced to detect the onset and growth of damage in gears. These various metrics have detected faults in several gear tests in experimental test rigs. Conditions in these tests have been steady state in the sense that the rpm, torque and forces on the gear have been held steady. For gears used in a dynamic environment such as that occurring in aircraft, the rpm, torque and forces on the gear are constantly changing. The authors have measured significant variation in rpm and torque in the transmissions of helicopters in controlled steady flight conditions flown by highly proficient test pilots. Statistical analyses of the data taken in flight show significant nonstationarity in the vibration measurements. These deviations from stationarity may increase false alarms in gear monitoring during aircraft flight. In the proposed paper, the authors will study vibration measurements made in flight on an AH- 1 Cobra and an OH-58C Kiowa helicopters. The primary focus will be the development of a methodology to assess the impact of nonstationarity on false alarms. Issues to be addressed include how time synchronous averages are constructed from raw data as well as how lack of stationarity effects the behavior of single value metrics. Emphasis will be placed on the occurrence of false alarms with the use of standard metrics. In order to maintain an acceptable level of false alarms in the flight environment, this study will also address the determination of appropriate threshold levels, which may need to be higher than for test rigs.

Mosher, M.↗

Development of procedures for calculating stiffness and damping of elastomers in engineering applications. Part 5: Elastomer performance limits and the design and test of an elastomer damper

Tests were performed on elastomer specimens of the material polybutadiene to determine the performance limitations imposed by strain, temperature, and frequency. Three specimens were tested: a shear specimen, a compression specimen, and a second compression specimen in which thermocouples were embedded in the elastomer buttons. Stiffness and damping were determined from all tests, and internal temperatures were recorded for the instrumented compression specimen. Measured results are presented together with comparisons between predictions of a thermo-viscoelastic analysis and the measured results. Dampers of polybutadiene and Viton were designed, built, and tested. Vibration measurements were made and sensitivity of vibration to change in unbalance was also determined. Values for log decrement were extracted from the synchronous response curves. Comparisons were made between measured sensitivity to unbalance and log decrement and predicted values for these quantities.

Tecza, J. A.↗

Concorde noise-induced building vibrations: International Airport Dulles

A series of studies were conducted to assess the noise-induced building vibrations associated with Concorde operations. The vibration levels of windows, walls, and floors were measured along with the associated noise levels of Concorde, subsonic aircraft and some nonaircraft events. Test sites included Sully Plantation which is adjacent to Dulles International Airport and three residential homes located in Montgomery County, Maryland. The measured vibration response levels due to Concorde operations were found to be: (1) higher than the levels due to other aircraft, (2) less than the levels due to certain household events which involve direct impulsive loading such as door and window closing, (3) less than criteria levels for building damage, and (4) comparable to levels which are perceptible to people.

Mayes, W. H.↗

Analysis of an axial compressor blade vibration based on wave reflection theory

The paper describes application of the theory of wave reflection in turbomachines to rotor blade vibrations measured in an axial compressor stage. The blade vibrations analyzed could not be predicted using various flutter prediction techniques. The wave reflection theory, first advanced in 1966, is expanded, and more general equations for the rotor blade excitation frequencies are derived. The results of the analysis indicate that all examined rotor blade vibrations can be explained by forced excitations caused by reflecting waves (pressure pulses). Wave reflections between the rotor blades and both the upstream and downstream stator vanes had to be considered.

Owczarek, J. A.↗