Search NASA⌕ Search

SEARCH · Search NASA

Results for “VOLTAGE AMPLIFIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Compact Radar Transceiver with Included Calibration

The Digital Beamforming Synthetic Aperture Radar (DBSAR) is an eight-channel phased array radar system that employs solid-state radar transceivers, a microstrip patch antenna, and a reconfigurable waveform generator and processor unit. The original DBSAR transceiver design utilizes connectorized electronic components that tend to be physically large and heavy. To achieve increased functionality in a smaller volume, PCB (printed circuit board) transceivers were designed to replace the large connectorized transceivers. One of the most challenging problems designing the transceivers in a PCB format was achieving proper performance in the calibration path. For a radar loop-back calibration path, a portion of the transmit signal is coupled out of the antenna feed and fed back into the receiver. This is achieved using passive components for stability and repeatability. Some signal also leaks through the receive path. As these two signal paths are correlated via an unpredictable phase, the leakage through the receive path during transmit must be 30 dB below the calibration path. For DBSAR s design, this requirement called for a 100-dB isolation in the receiver path during transmit. A total of 16 solid-state L-band transceivers on a PCB format were designed. The transceivers include frequency conversion stages, T/R switching, and a calibration path capable of measuring the transmit power-receiver gain product during transmit for pulse-by-pulse calibration or matched filtering. In particular, this calibration path achieves 100-dB isolation between the transmitted signal and the low-noise amplifier through the use of a switching network and a section of physical walls achieving attenuation of radiated leakage. The transceivers were designed in microstrip PCBs with lumped elements and individually packaged components for compactness. Each transceiver was designed on a single PCB with a custom enclosure providing interior walls and compartments to isolate transceiver subsystems from radiated interference. The enclosure also acts as a heat sink for the voltage regulators and power amplifiers inside the system. The PCB transceiver design produces transmit pulses of 2 W with an arbitrary duty cycle. Each transceiver is fed by an external 120-MHz signal transmit and two 1,140-MHz local oscillator signals. The received signal is amplified and down-converted to 120 MHz and is fed to the data processor. The transceiver dimensions are approximately 3.5 11.5 0.6 in. (9 29 1.5 cm). The PCB transceiver design reduces the volume and weight of the DBSAR instrument while maintaining the functionality found in the original design. Both volume and weight are critical for airborne and flight remote sensing instrumentation.

McLinden, Matthew↗

Electrostatic Regolith Interaction Experiment (ERIE) Electrometer Instrument Development

The Electrostatic Regolith Interaction Experiment (ERIE) is a joint venture between the University of Central Florida (UCF) Center for Microgravity Research (CMR) and the NASA Kennedy Space Center (KSC) Electrostatics and Surface Physics Laboratory (ESPL) seeking to examine charged dust grain behavior in a microgravity environment. Two separate systems have been combined for this suborbital flight experiment: the COLLisions Into Dust Experiment (COLLIDE) developed by the UCF CMR and the Wheel Electrostatic Spectrometer (WES) developed by the NASA KSC ESPL. This combination will advance the understanding of the natural and induced charged grain behavior on the Moon, asteroids, and other low gravity bodies comprised of charged dust particles. COLLIDE retains granular material under vacuum in a shallow tray behind a metal door, which then opens and releases the particles into a larger open volume when microgravity is achieved. The experiment is observed with a high-speed camera, such that the motions of these particles can then be tracked so the kinematics of each grain may be analyzed. The original application for this apparatus was to study cratering events into granular beds, but electrostatic repulsion was detected in the early frames of the video data returned from completed experiments, so a re-flight with a focus on these events was proposed. Agitation of the grains during launch combined with the frictional charge transfer between the grains and the door as it slides open provides an opportunity to use this setup to observe material tribocharging and charged particle behaviors in microgravity. In this updated version, the charged particles released into the chamber will traverse through an electric field produced by high voltage parallel plates and their resulting trajectories will be determined by their net charges. WES was originally developed to characterize the triboelectric properties of the Martian regolith through the contact of a rover wheel with the surface as it rotates. Improvements were made upon this legacy system to develop a sensor suite that will be installed within the COLLIDE door to measure charge transferred between the granular material and insulating disks protruding through the door. These insulator disks span the triboelectric series so, as they slide across the particulate matter when the door opens, each will accumulate a charge consistent with its relative position to the grains within the series. This charge on each insulator is distributed between two capacitances in series with an electrometer amplifier returning an analog voltage proportional to the charge accumulated. Calibration of this system has been performed using applications of known charge to the inputs and characterization of the frictional charge transfer between various regolith simulants and the sensor insulators is currently being examined in the lab.

Electrostatics↗

Signal conditioner circuit for photomultiplier tube

Miniaturized circuit improves measurement of radiation dose absorbed in a scintillation crystal. The temperature coefficient of the field-effect transistor gate-source voltage in the isolation amplifier can be readily controlled.

Cellier, A.↗

A range expanding signal conditioner

Telemetry system modifications to improve signal resolution are described. Process uses zero suppression technique which consists of subtracting known voltage from input and amplifying remainder. Schematic diagram of circuit is provided and details of operation are presented.

Russell, W. A.↗

Meter circuit for tuning RF amplifiers

Circuit computes and indicates efficiency of RF amplifier as inputs and other parameters are varied. Voltage drop across internal resistance of ammeter is amplified by operational amplifier and applied to one multiplier input. Other input is obtained through two resistors from positive terminal of power supply.

Longthorne, J. E.↗

Programable Driver for Voltage-Controlled Oscillators

Electronically programable read-only memory (EPROM) and digital-to-analog converter provide customized time-varying voltage for frequency modulation. Voltage used to modulate IMPATT oscillator that serves as microwave pump for solid-state maser in low-noise amplifier. EPROM simple to tailor voltage waveform to suit characteristics of given maser. Digital information for waveform programed into EPROM chip; digital-to-analog converter reads information and produces corresponding analog wave. Principle readily adapted to other applications.

Fowler, L. E.↗

Non-Destructive Evaluation Method and Apparatus for Measuring Acoustic Material Nonlinearity

An acoustic non-linearity parameter (beta) measurement method and system for Non-Destructive Evaluation (NDE) of materials and structural members obviates the need for electronic calibration of the measuring equipment. Unlike known substitutional measuring techniques requiring elaborate calibration procedures, the electrical outputs of the capacitive detector of a sample with known beta and the test sample of unknown beta are compared to determine the unknown beta. In order to provide the necessary stability of the present-inventive reference-based approach, the bandpass filters of the measurement system are maintained in a temperature-controlled environment, and the line voltage supplied to said amplifiers is well-regulated.

William T Yost↗

A Novel Reconfigurable GaN Based Fully Solid-State Microwave Power Module for Communications/Radar Applications

In this paper, we present as a proof-of-concept (POC) the design, integration, and performance of a novel reconfigurable GaN based fully solid-state MPM. The module synergistically integrates diplexers, pre-amplifiers, multistage medium power amplifiers (MPAs), SPDT switches, and CW/Pulsed high power amplifiers (HPAs) with a voltage sequencer, a DC blanking controller, and a low voltage electronic power conditioner. The POC SSMPM operates at both S-band and X-band to serve multiple roles. The SSMPM can be reconfigured to deliver Psat of 39 dBm (8 W CW) at S-band, Psat of 46 dBm (40 W CW) at X-band, and Psat of >50 dBm (>100 W Pulsed) at X-band. Lastly, our link budget calculations indicate that the SSMPM with Psat = 40 W when coupled to a 10 cm X-band transmit antenna on a low Earth orbiting (900 km) satellite can close a 1 Gbps (QPSK) data downlink to a 1 m receive antenna on ground with 3 dB margin.

Simons, Rainee N.↗

Charge-coupled differential amplifier

Device solves problem of differential voltage gain in sampled-data metal-oxide semiconductor, producing gain at any frequency compatible with CCD operation, with low noise, low power, good linearity, and high stability.

Hewes, C. R.↗

Ultra low-noise charge coupled device

Special purpose CCD designed for ultra low-noise imaging and spectroscopy applications that require subelectron read noise floors, wherein a non-destructive output circuit operating near its 1/f noise regime is clocked in a special manner to read a single pixel multiple times. Off-chip electronics average the multiple values, reducing the random noise by the square-root of the number of samples taken. Noise floors below 0.5 electrons rms are possible in this manner. In a preferred embodiment of the invention, a three-phase CCD horizontal register is used to bring a pixel charge packet to an input gate adjacent a floating gate amplifier. The charge is then repeatedly clocked back and forth between the input gate and the floating gate. Each time the charge is injected into the potential well of the floating gate, it is sensed non-destructively. The floating gate amplifier is provided with a reference voltage of a fixed value and a pre-charge gate for resetting the amplifier between charge samples to a constant gain. After the charge is repeatedly sampled a selected number of times, it is transferred by means of output gates, back into the horizontal register, where it is clocked in a conventional manner to a diffusion MOSFET amplifier. It can then be either sampled (destructively) one more time or otherwise discarded.

Janesick, James R.↗

Performance of High Temperature Operational Amplifier, Type LM2904WH, under Extreme Temperatures

Operation of electronic parts and circuits under extreme temperatures is anticipated in NASA space exploration missions as well as terrestrial applications. Exposure of electronics to extreme temperatures and wide-range thermal swings greatly affects their performance via induced changes in the semiconductor material properties, packaging and interconnects, or due to incompatibility issues between interfaces that result from thermal expansion/contraction mismatch. Electronics that are designed to withstand operation and perform efficiently in extreme temperatures would mitigate risks for failure due to thermal stresses and, therefore, improve system reliability. In addition, they contribute to reducing system size and weight, simplifying its design, and reducing development cost through the elimination of otherwise required thermal control elements for proper ambient operation. A large DC voltage gain (100 dB) operational amplifier with a maximum junction temperature of 150 C was recently introduced by STMicroelectronics [1]. This LM2904WH chip comes in a plastic package and is designed specifically for automotive and industrial control systems. It operates from a single power supply over a wide range of voltages, and it consists of two independent, high gain, internally frequency compensated operational amplifiers. Table I shows some of the device manufacturer s specifications.

Patterson, Richard↗

Active control of flexural vibrations in beams

The feasibility of using piezoelectric actuators to control the flexural oscillations of large structures in space is investigated. Flexural oscillations are excited by impulsive loads. The vibratory response can degrade the pointing accuracy of cameras and antennae, and can cause high stresses at structural node points. Piezoelectric actuators have the advantage of exerting localized bending moments. In this way, vibration is controlled without exciting rigid body modes. The actuators are used in collocated sensor/driver pairs to form a feedback control system. The sensor produces a voltage that is proportional to the dynamic stress at the sensor location, and the driver produces a force that is proportional to the voltage applied to it. The analog control system amplifies and phase shifts the sensor signal to produce the voltage signal that is applied to the driver. The feedback control is demonstrated to increase the first mode damping in a cantilever beam by up to 100 percent, depending on the amplifier gain. The damping efficiency of the control system when the piezoelectrics are not optimally positioned at points of high stress in the beam is evaluated.

Gerhold, Carl H.↗

Gyrator employing field effect transistors

A gyrator circuit of the conventional configuration of two amplifiers in a circular loop, one producing zero phase shift and the other producing 180 deg phase reversal is examined. All active elements are MOS field effect transistors. Each amplifier comprises a differential amplifier configuration with current limiting transistor, followed by an output transistor in cascode configuration, and two load transistors of opposite conductivity type from the other transistors. A voltage divider control circuit comprises a series string of transistors with a central voltage input to provide control, with locations on the amplifiers receiving reference voltages by connection to appropriate points on the divider. The circuit produces excellent response and is well suited for fabrication by integrated circuits.

Hochmair, E. S.↗

A new dry biomedical electrode

Electronic circuitry contains new operational amplifier which incorporates monolithic super-gain transistors. Electrode does not provide voltage amplification; instead, it acts as current amplifier to make it possible to pick up electrical potentials from surface of highly resistant dry skin.

Luce, R. S.↗

Characterization of Transducers and Resonators under High Drive Levels

In many applications, piezoelectric transducers are driven at AC voltage levels well beyond the level for which the material was nominally characterized. In this paper we describe an experimental setup that allows for the determination of the main transducer or resonator properties under large AC drive. A sinusoidal voltage from a waveform generator is amplified and applied across the transducer/resonator in series with a known high power resistor. The amplitude of applied voltage and the amplitude and the relative phase of the current through the resistor are monitored on a digital scope. The frequency of the applied signal is swept through resonance and the voltage/current signals are recorded. After corrections for the series resistance and parasitic elements the technique allows for the determination of the complex impedance spectra of the sample as a function of frequency. In addition, access to the current signal allows for the direct investigation of non-linear effects through the application of Fourier transform techniques on the current signal. Our results indicate that care is required when interpreting impedance data at high drive level due to the frequency dependence of the dissipated power. Although the transducer/resonator at a single frequency and after many cycles may reach thermal equilibrium, the spectra as a whole cannot be considered an isothermal measurement due to the temperature change with frequency. Methods to correct for this effect will be discussed. Results determined from resonators of both soft and hard PZT and a ultrasonic horn transducer are presented.

transducers↗

Correcting for Nonlinearity in a Photodetector

Simple positive-feedback circuit varies bias voltage as necessary. Ideal detector biased with constant voltage, detector current proportional to photon flux plus constant offset. Detector connected between inverting input and ground, and feedback from operational amplifier through feedback resistor Rf make voltage at inverting input equal to noninverting input. Bias voltage held constant. Principle applied to linearizing mercury cadmium telluride infrared detectors in Fourier-transform spectrometers and other spectral and imaging instruments.

Schindler, R. A.↗

The effects of feedback amplifier characteristics on constant temperature hot-wire anemometer systems

The 3rd-order analysis of Perry and Morrison (1971) was extended to 7th-order by Watmuff (1987) by including both the bridge-capacitance and the frequency-response characteristics of the feedback amplifier. In this paper, the bridge capacitance has been excluded from the analysis. The influence of the gain K, roll-off frequency f(A), and offset voltage E(qi) of the feedback amplifier are examined in more detail together with their interactions with the bridge inductance.

Watmuff, J. H.↗

Modeling a Common-Source Amplifier Using a Ferroelectric Transistor

This paper presents a mathematical model characterizing the behavior of a common-source amplifier using a FeFET. The model is based on empirical data and incorporates several variables that affect the output, including frequency, load resistance, and gate-to-source voltage. Since the common-source amplifier is the most widely used amplifier in MOS technology, understanding and modeling the behavior of the FeFET-based common-source amplifier will help in the integration of FeFETs into many circuits.

Sayyah, Rana↗