Search NASA⌕ Search

SEARCH · Search NASA

Results for “Verification Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Developing a Nuclear Quality Assurance Compliant Design Methodology for Neutronic Analysis of Xe-100 Design

The primary objective of this work is to develop a design methodology compliant with nuclear quality assurance standards for the Xe-100 neutronic design verification studies. To achieve this, a Monte Carlo model of the Xe-100 reactor was constructed using the exclusion principle, transformation technique, and universe-based level specification following Idaho National Laboratory (INL) NQA level-1 compliant standards and an NQA-1 compliant version of MCNP6. The model encompasses the entire reactor core structures, including the upper plenum, core region, and lower plenum sections, along with all sub-components. The active core section was represented using the spectral regions, each comprising a particular fuel composition and temperature averaged over the considered zone, calculated by X-energy using Very Superior Old Programs (VSOP). Additionally, a component-wise temperature map was implemented into the model, not only for the core region but also for the structural components. Temperature-dependent cross-section libraries, along with thermal scattering law libraries, generated using INL NQA-1 compliant version of NJOY21, were utilized for each isotope in the burnt fuel and the structural materials. Furthermore, the volume of each modeled component was estimated using a stochastic approach with the ray tracing method in MCNP and criticality calculations were performed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Towards a NEAMS-based high-fidelity model of the MARVEL reactor

This report outlines the progress of Idaho National Laboratory in developing a high-fidelity and high-resolution model of the Microreactor Applications Research Validation and Evaluation reactor. The model was developed under the Nuclear Energy Advanced Modeling and Simulation microreactor application driver at Idaho National Laboratory. The overarching objective of this activity is the development of a high-fidelity multiphysics MARVEL model using NEAMS tools, and to verify and validate NEAMS tools against MARVEL reference simulation and experimental data, respectively. This is a unique opportunity to conduct multiphysics analysis on a soon-to-be-deployed microreactor. This multiphysics model developed under the NEAMS-funded INL microreactor application driver leverages three single-physics models coupled via the MOOSE’s MultiApp and Transfer systems. The latter systems enable in-memory data transfer between MOOSE-based and MOOSE-wrapped applications. The first single-physics model, that functions as main application, leverages Griffin to model the neutron transport in the core through the discontinuous finite element (DFEM) discrete ordinates solver (SN). Several optimization flags that were developed by the Griffin developer team were beta-tested to enhance the solver’s performance. These include the combined use of using_average_xs and update_averaged_xs_on that enable to avoid expensive on-the-fly cross sections evaluations at each linear iterations in favor of evaluations of the macroscopic cross sections at each Picard iteration. The second single-physics model uses BISON to handle solid heat transfer and asymptotic hydrogen redistribution analysis in the fuel. While the model returns consistent results for the temperature and hydrogen distribution in the fuel, a mismatch was noticed in the calculated temperature in the reflector due to the value of the gap conductance used in our model. Ongoing investigations are being performed to assess the origin of this discrepancy. Finally, the System Analysis Module (SAM) was used to model the flow of the sodium-potassium eutectic in the primary loop. A first verification was also performed showing good agreement in terms of mass flow rate and inlet temperature. All mesh files were generated using the MOOSE Reactor module, removing the need for external meshing tools. Notably, this workscope represents one of the initial applications of the MOOSE Reactor module for modeling highly irregular geometries. The use of the reactor module significantly streamlined the mesh generation process. The full multiphysics mode, that combines all the single physics models, was leveraged to conduct initial steady-state multiphysics simulations to compute power, and temperature distribution in the reactor. Initial testing was performed for transient simulations as well. In this case, the new checkpoint restart capability for eigenvalue calculations was tested showing the capability for streamlined restart of transient calculations. Future work will focus on improving the fidelity of the model by performing comprehensive code-to-code comparisons. For instance, the full-core Griffin neutronics model will be benchmarked against MCNP reference results, that were provided by the MARVEL design team. Additionally, the SAM T/H model will be verified against reference RELAP-5 results for selected accident scenarios. Besides code-to-code verification exercises, the model fidelity will be improved by replacing the single-channel SAM model with a more complex SAM-Pronghorn coupled model, in which the sub-channel capability is deployed to obtain radial temperature resolution in the coolant. This model will be developed in synergy with the NEAMS thermal hydraulics team.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geomagnetically Induced Current Field Test on Large Grid-Connected Power Transformers: Analysis, Model Development, and Simulations

Geomagnetic-induced current (GIC) flow in power grids can cause undesirable effects such as transformer overheating, harmonics, higher reactive power demand, etc. Many simulation models have been developed to study these effects, but real-world verification on modern transformer designs is rare. Here, this paper presents the first long-duration GIC field test in the U.S. performed on high-voltage, grid-connected transformers featuring winding clamps and tie rods instead of conventional tie bars. Field measurements were taken to evaluate GIC effects. These measurements also aided in developing and validating thermal and electromagnetic transient (EMT) models of the transformers. During the test, significant current and voltage distortions were observed along with considerable transformer reactive power losses. Analysis of the field measurements showed that the transformers’ hottest spot was at the inner windings, and their k-factors were close to factory test and software default values. Thermal simulations indicated that the transformers would not violate their thermal limits even for a GIC waveform that peaks at about 200 A/phase. EMT simulations revealed that increased transformer loading may reduce GIC-induced reactive power demand and harmonics in certain scenarios. The study also highlighted potential inaccuracies in using the k-factor method to calculate transformer reactive power losses.

EMTDC↗

COMPUTATION FLUID DYNAMICS ANALYSIS FOR GENERIC SMALL MODULAR REACTOR CONTAINMENT SEPARATE EFFECTS TEST

It is desirable for fourth-generation Small Modular Reactors to be passively cooled in standard and accident operations. Passive Containment Cooling Systems can reject heat from the containment structure, without using pumps or blowers. The targeted design containment structure is a large, domed, stainless steel, cylindrical vessel. In a postulated Design Basis Accident, steam will flash inside containment. Steam condensation occurs on the inner containment wall and transfers heat through the steel containment into a large body of water known as the annular reservoir (AR) surrounding the vessel serving as the ultimate heat sink. Natural circulation drives the flow in the AR and heat will be released to the environment by evaporation of water. Unique containment geometry requires a separate effects test (SET) facility for the verification and validation of the computer code and evaluation model development and assessment for reactor licensing efforts. In this study, STAR-CCM+, a computational fluid dynamics (CFD) code was used to inform the decision-making process on the design of the SET. The CFD simulation modeled, a two-phase turbulent flow with fluid film development and heat transfer for different containment geometries. The Reactor Excursion and Leak Analysis Program will also be used in a code-to-code verification against the CFD results.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Exploring Interferometry Diagnostics for Optical Stochastic Cooling at FAST/IOTA

Optical Stochastic Cooling (OSC) is an advanced beam-cooling technique that will precede the traditional stochastic cooling. This method leverages optical radiation and high-precision feedback to cool the particles more efficiently than traditional stochastic methods by more than three orders of magnitude. As such, it is an enabler for the development of next generation discovery science machines at the frontiers of energy and intensity. This paper focuses on the development of the second phase of OSC and improving extreme beam cooling technique in accelerators. Along with the assembly and use of an interferometer to provide diagnostics and optimization to OSC systems. The interferometer can allow for the observation and analysis of fringe patterns from a recreated simpler version in the laser room. By leveraging interferometric techniques, OSC can achieve higher efficiency, verification, stability and performance.

Teriba, Folashade↗

Electrical and Thermal Load Impacts of Three District Heating and Cooling Designs for an Existing Community in Washington, DC

District energy systems that provide building heating and cooling are a promising option to provide low-cost, energy efficient heating and cooling solutions for communities. As some buildings move to electrified heating designs, there may be significant increases in electric grid demand, particularly in the winter. District energy systems may be able to help reduce these high electrical demands on the electric grid, while also providing decreased overall energy consumption with an increased flexibility in electrical energy usage. To evaluate and compare district options for district-based heating and cooling, an existing neighborhood of Washington, DC consisting of 35 existing buildings was selected as a case study. This study models and compares a fourth generation (4G) district heating and cooling systems that provide hot and chilled water from a central plant directly to each prosumer and a fifth generation (5G) district heating and cooling systems that provide near-ambient water via geothermal boreholes to interface with an energy transfer station with a heat pump at each prosumer. These district systems are compared against a baseline of the non-connected buildings with their self-contained and current HVAC systems. The neighborhood was selected as a good candidate for a district system for its diversity of loads (mix of different commercial and property types) and the availability of building characteristics. URBANopt District Energy Systems (DES) was used to model the buildings and create initial Modelica models for the district systems. Finally, the DES models were tuned and simulated in Dymola, and the outputs were post-processed for verification and to calculate the electrical and thermal grid impact metrics. This is the first documentation of this workflow and its complete analysis. The three designed systems are compared via their grid metrics including: total energy consumption, electrical demand peak loads, daily peak-to-valley ratios, and system ramping. A detailed discussion is provided about how each system impacts and interacts with the electric grid.

15 GEOTHERMAL ENERGY↗

Develop and verify soil/structure interaction for pile/foundation interaction

Phase II of the Offshore Code Comparison Collaboration, Continued, with Correlation and unCertainty (OC6) project was used to verify the implementation of a new soil-structure interaction (SSI) model for use within offshore wind turbine modeling software. The REDWIN Macro-element model implemented and verified in this study enables a computationally efficient way to model the linear and nonlinear SSI problem, including hysteretic damping, of a monopile structure. The modeling approach was integrated into several modeling tools and a series of increasingly complex simulations was conducted using the IEA 10MW reference turbine mounted on a monopile support structure to verify the coupling between the tools and the REDWIN Macro-element SSI model. This campaign includes only numerical verification between various software and modeling approaches so no experimental measurements are available. The load cases (LC) considered include: LC1 – static response of the tower and substructure LC2 – frequency and mode-shape analysis of the tower and substructure LC3 – response of the tower and substructure due to wind-only loading LC4 – response of the tower and substructure due to wave-only loading LC5 – response of the tower and substructure due to wind and wave loading. Detailed properties of the modeled system are found in the following reference, “Bergua, Roger, Amy Robertson, Jason Jonkman, and Andy Platt. 2021. "Specification Document for OC6 Phase II: Verification of an Advanced Soil-Structure Interaction Model for Offshore Wind Turbines.” Golden, CO: National Renewable Energy Laboratory. NREL/TP-5000-79938. https://www.nlr.gov/docs/fy21osti/79938.pdf. Details on the results from the OC6 Phase II project can be found in the following reference, “Bergua R, Robertson A, Jonkman J, et al. OC6 Phase II: Integration and verification of a new soil–structure interaction model for offshore wind design.” Wind Energy. 2022;25(5):793-810. doi:10.1002/we.2698

17 WIND ENERGY↗

Steam generator model design parameter sensitivity study for small modular reactor system

Here, this study focuses on design parameter sensitivity studies pertaining to several Once-Through Steam Generator (OTSG) model cases both with and without a riser using python and advanced risk assessment and optimization tool, i.e. Risk Analysis Virtual Environment (RAVEN) developed at Idaho National Laboratory (INL), to support a Small Modular Reactor (SMR) system. The presented Steam Generator (SG) python-based model is a mathematical representation of a steam-generating unit for a Pressurized Water Reactor (PWR)-type SMR system, including fluid flow and heat transfer equations, models, and correlations. Design studies involve changing the model’s input design parameters (e.g., temperature, pressure, mass flow rate) to observe the resulting effects on the output of the system, such as the Heat Transfer Coefficient (HTC), Reynolds number, Nusselt number, and heat transfer performance. Sensitivity studies analyze the degree to which system output and/or desired parameters (e.g., HTC or heat transfer performance) are sensitive to changes in the input parameters. By using RAVEN, detailed design parametric sensitivity studies. Six input parameters—namely, the pressure, temperature, and mass flow rate for the inlet of the primary-side (hot fluid) and secondary-side (cold fluid) of the SG—were randomly perturbed via RAVEN’s Monte Carlo Sampler module, using uniform distributions (i.e., ±1%, ±5% and ±10 % relative changes) for 600 samples. The analysis results give valuable insights into SG system performance, and provide justification for further research and development such as optimized sensor placement, design verification, validation, and optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Serpent - Bison - THM Preliminary Multiphysics Modeling of a Nuclear Thermal Propulsion System Fuel Assembly

This work demonstrates the Monte Carlo neutronic and Thermo-Hydraulic coupling scheme using the Serpent code and MOOSE application Bison and Thermo Hydraulic Module. The coupling scheme is then applied to the reference BWX Technologies Nuclear Ther- mal Propulsion system at he fuel assembly level where it’s used to perform an analysis of the isothermal material coefficients and potential material reactivity worth. A method is developed to isolate which feedback effects should be considered for proceeding with reduced order deterministic neutronic modeling where branch off analysis must be con- ducted. The convergence behavior of the coupling scheme is demonstrated where it fol- lows the standard Picard iteration approach. Verification studies for the method of deduc- ing relevant feedback effects is also demonstrated.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A methodology for domain overlapping coupling of thermal-hydraulic systems

Multi-scale coupling has increasingly drawn attention as a promising approach for modeling thermal systems. Traditional system codes provide fast and robust predictions at the plant scale, while high-fidelity computational fluid dynamics (CFD)-based tools resolve localized flow and heat transfer phenomena with greater accuracy. By combining these complementary strengths, co-simulations enable multi-scale analysis that would otherwise be computationally prohibitive for a standalone CFD code. Here, this work introduces a robust and problem-agnostic domain overlapping (DO) coupling between the system thermal-hydraulic (STH) code System Analysis Module (SAM) and the coarse-mesh CFD code Pronghorn. Both applications belong to the Comprehensive Reactor Analysis Bundle (BlueCRAB) code suite, a code suite in active development at the Idaho National Laboratory (INL), tailored for multi-physics analysis of advanced reactors. Unlike previous approaches, BlueCRAB supports an agnostic interface between codes based on different fidelity, while its coupling formulation can address arbitrary flow geometries with multiple inlets and outlets in coupled components. The implemented method leads to consistent pressure drops, enthalpies, and scalar concentrations between coupled SAM and Pronghorn simulations. The methodology is demonstrated through two verification tests, which ensure the numerical consistency and conservation across the codes, and through one validation test against experimental data. The proposed problems explore different physical aspects inherent to thermal systems, with particular attention given to nuclear reactor analysis. These include buoyancy-driven flows, complex flow patterns, and setups with multiple inlets and outlets, representing challenges in advanced reactor applications.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Greenhouse Gas Accounting Procedures in Low Carbon Fuel Policies Overlook the Spatial Variability of Miscanthus-Derived Sustainable Aviation Fuel

Low carbon fuel policies such as the U.S. Renewable Fuel Standard (RFS), Canada Clean Fuel Regulations (CFR), and California Low Carbon Fuel Standard (LCFS) as well as the 45Z tax credit are intended to reduce greenhouse gas (GHG) emissions from transportation. Cellulosic feedstocks, optimized biorefineries, and favorable farming locations can significantly reduce biofuel carbon intensity (CI). Despite advances in field-to-fuel GHG monitoring and flexibility in resource allocation within biorefineries (e.g., governing net electricity production), rigid CI accounting procedures in current policies may limit CI responsiveness across candidate sites and processing facilities. Here, this work examines a hypothetical biomass-to-sustainable aviation fuel (SAF) pathway using miscanthus and alcohol-to-jet (i) to demonstrate how GHG accounting requirements drive estimates of biofuel CIs and (ii) to explore potential CI and financial implications of scenario-specific life cycle assessment (LCA). Results demonstrate that GHG accounting using the CFR/LCFS can reasonably account for distinct levels of net electricity production by a biorefinery, but only the CFR yields similar CI sensitivity to spatially explicit factors (feedstock CI, grid electricity CI) as scenario-specific LCA: most GHG accounting frameworks do not capture CI variation across candidate sites in the United States. Ultimately, this work demonstrates the importance of LCA methodological specifications in low carbon fuel policies and tax credits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of dried blood spot sampling for verification of exposure to chemical threat agents

Abstract Purpose Exposure to chemical threat agents (CTAs), including nerve agents, the vesicating agent sulfur mustard, and opioids, remains a significant threat to warfighter and civilian populations. Definitive analytical methods to verify exposure to CTAs require shipping refrigerated or frozen biomedical samples to reference laboratories for analysis. Logistical and financial burdens arise as the transport of biomedical samples is subject to strict restrictions and complex packaging, which, if done incorrectly, can lead to sample deterioration. The use of dried blood spot (DBS) sampling could provide operational improvements for collecting, storing, and shipping important forensic samples. Therefore, this effort focuses on developing DBS techniques with Mitra® 30-µL volumetric absorptive microsampling (VAMS®) devices for use in CTA exposure verification. Methods VAMS® devices were loaded and dried with human whole blood that was exposed to the metabolites pinacolyl methylphosphonic acid (PMPA), ethyl methylphosphonic acid (EMPA), 1,1’sulfonylbis[2-(methylsulfinyl)ethane] (SBMSE), norfentanyl, norcarfentanil, norsufentanil, and norlofentanil. Following extraction from the VAMS® devices, metabolites were detected using liquid chromatography-tandem mass spectrometry (LC–MS/MS). The methods were validated for performance by assessing sensitivity, precision, accuracy, and recovery. Results These methods were sensitive to 1 ng/mL for SBMSE, 0.5 ng/mL for PMPA, EMPA, and norfentanyl; 0.1 ng/mL for norlofentanil, and 0.05 ng/mL for norsufentanil and norcarfentanil. All methods met acceptable precision and accuracy criteria with favorable recovery. Conclusions These results demonstrated the utility of VAMS® in stabilizing human whole blood and show promise as an improved collection method for verification of exposure to various CTAs.

Toxicology↗

Carbon Utilization and Storage Partnership of the Western United States

This technical report documents research conducted under DOE Award No. DE-FE0031837 focused on evaluating the feasibility of carbon capture, utilization, and storage (CCUS) systems in the central and western United States. The project integrated geologic characterization, reservoir simulation, infrastructure modeling, and economic analysis to assess CO₂ storage potential near industrial sources and develop strategies for transport and sequestration. The work included subsurface modeling, risk assessment, monitoring and verification (MRV) planning, and evaluation of regulatory pathways such as EPA Underground Injection Control (UIC) Class VI permitting and IRS 45Q tax credit eligibility. Results demonstrate the viability of multiple storage approaches, including saline formations, enhanced coalbed methane recovery, and basalt mineralization, supported by data-driven workflows and regional analyses. The project also produced permitting templates, technology transfer activities, and stakeholder engagement efforts to support deployment readiness. These findings contribute to the development of scalable, economically viable CCUS systems and provide a repeatable framework for future carbon management projects.

20 FOSSIL-FUELED POWER PLANTS↗

STAT7 v2.0 Verification and Validation Report

This report documents the software testing which has been performed for STAT7 Version 2.0 (hereafter STAT7 v2.0), a code for the statistical propagation of uncertainties in steady-state thermal hydraulics (TH) analysis of plate-fueled research and test reactors. The key capabilities addressed in this testing were selected based on the use of the software for analysis work supporting the conversion to low-enriched uranium fuel of U.S. High-Performance Research Reactors (USHPRR) such as the Massachusetts Institute of Technology Research Reactor (MITR-II). This testing scope includes comparison of the code’s statistical processing capabilities using statistical tests, comparison of coolant property evaluations to NIST data tables, and systematic comparison of key TH solver capabilities to the results of hand calculations and to predictions from PLTEMP/ANL Version 4.4. The

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Evaluation of AI-Enabled Digital Documented Safety Analysis: A Case Study

Safety basis documentation development and review under U.S. Department of Energy (DOE) authorization have emerged as critical constraint throttling deployment of advanced nuclear reactors, with traditional processes demanding extraordinary resource investment that delays the delivery of these technologies. Traditional Documented Safety Analysis (DSA) processes rely on static documents with limited traceability [U.S. DOE]. The regulatory review and engagement processes are similarly constrained, often requiring significant effort and extensive manual verification. The scale of this challenge is exemplified by the U.S. Nuclear Regulatory Commission (NRC) review of the NuScale application, which required over 250,000 staff hours and the evaluation of approximately two million pages of documentation [Bergman 2021]. The volume and complexity of information within nuclear licensing applications or authorization reviews demands innovative approaches to document generation and data management.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Quantum error mitigation for Fourier moment computation

Hamiltonian moments in Fourier space—expectation values of the unitary evolution operator under a Hamiltonian at different times—provide a convenient framework to understand quantum systems. They offer insights into the energy distribution, higher-order dynamics, response functions, correlation information, and physical properties. This paper focuses on the computation of Fourier moments within the context of a nuclear effective field theory on superconducting quantum hardware. The study integrates echo verification and noise renormalization into Hadamard tests using control reversal gates. These techniques, combined with purification and error suppression methods, effectively address quantum hardware decoherence. The analysis, conducted using noise models, reveals a significant reduction in noise strength by two orders of magnitude. Moreover, quantum circuits involving up to 266 gates over five qubits demonstrate high accuracy under these methodologies when run on IBM superconducting quantum devices. Published by the American Physical Society 2025

Kiss, Oriel (ORCID:0000000174613342)↗

Using Temporal Information from Human Mobility Data to Detect Anchor Points

Spatiotemporal mobility data are available in massive quantities, but large quantities of data typically include fewer variables or data fields. Often, the only available fields are User ID, Longitude, Latitude, Timestamp (ULLT). This raises an important question: how much can we infer about human mobility patterns using only these four fields? With ULLT data, we do not know individuals' socioeconomic status information or when they are visiting their anchor points (AP) or locations (such as homes, places of employment, or schools), and it is a modern challenge to use this data to infer these characteristics. When detecting anchor locations with limited input information, verification and validation (VV) are significant challenges. This paper addresses the problem of identifying individuals' anchor locations using only temporal information from spatiotemporal datasets with limited attributes. Our approach does not explicitly use latitude and longitude during analysis. Locationbased information is only employed in the preprocessing stage to identify periods of movement (trips) and stops (dwelling). Beyond this step, all analysis is based on temporal patterns. In theory, if stops and dwell times could be detected through alternative means, our method could function entirely without location-based input. We demonstrate this methodology on the 2017 National Household Travel Survey (NHTS) data, because it includes a carefully designed and collected time use survey with representative sampling and labeled ground truth. The high-quality survey data allows us to test the accuracy of our methods because NHTS contains intended place labels and agent/user characteristics. We have also applied our validated AP identification algorithm on very large-scale GPS based trajectory data for Patterns-of-Life (PoL) assessment and other applications, but due to space limit that could not be presented here.

McBride, Liz [ORNL] (ORCID:0000000286925869)↗