Search NASASearch

SEARCH · Search NASA

Results for “Viscosity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Viscosity Coefficient Curve Fits for Ionized Gas Species Grant Palmer

Viscosity coefficient curve fits for neutral gas species are available from many sources. Many do a good job of reproducing experimental and computational chemistry data. The curve fits are usually expressed as a function of temperature only. This is consistent with the governing equations used to derive an expression for the neutral species viscosity coefficient. Ionized species pose a more complicated problem. They are subject to electrostatic as well as intermolecular forces. The electrostatic forces are affected by a shielding phenomenon where electrons shield the electrostatic forces of positively charged ions beyond a certain distance. The viscosity coefficient for an ionized gas species is a function of both temperature and local electron number density. Currently available curve fits for ionized gas species, such as those presented by Gupta/Yos, are a function of temperature only. What they did was to assume an electron number density. The problem is that the electron number density they assumed was unrealistically high. The purpose of this paper is two-fold. First, the proper expression for determining the viscosity coefficient of an ionized species as a function of both temperature and electron number density will be presented. Then curve fit coefficients will be developed using the more realistic assumption of an equilibrium electron number density. The results will be compared against previous curve fits and against highly accurate computational chemistry data.

Palmer, Grant

Viscosity Relaxation in Molten HgZnTe

Because of its narrow electronic band-gap, HgZnTe solid solutions have been proposed as effective detectors for infrared radiation. To produce the best single crystals of these materials for this application, knowledge of the phase diagram that governs the freezing of the liquid is essential. Besides the phase diagram, however, some information concerning the thermophysical properties of the melt, such as viscosity, density, specific heat, and enthalpy of mixing, can also be useful. Of these thermophysical properties, the viscosity is perhaps of the most interest scientifically. Measurements using the oscillating cup method have shown that the isothermal melt requires tens of hours of equilibration time before a steady value of the viscosity can be achieved. Over this equilibration time, which depends upon temperature, the viscosity can increase by as much as a factor of two before reaching a steady state. We suggest that this relaxation phenomenon may be due to a slight polymerization of Te atoms in the melt.

James K. Baird

Acoustic Experiment to Measure the Bulk Viscosity of Near-Critical Xenon in Microgravity

We plan a rigorous test of the theory of dynamic scaling by accurately measuring the bulk viscosity of xenon in microgravity 50 times closer to the critical temperature T(sub c) than previous experiments. The bulk viscosity zeta (or "second viscosity" or "dilational viscosity") will be determined by measuring the attenuation length of sound alpha lambda and also measuring the frequency-dependence of the speed of sound. For these measurements, we developed a unique Helmholtz resonator and specialized electro-acoustic transducers. We describe the resonator, the transducers, their performance on Earth, and their expected performance in microgravity.

Gillis, K. A.

Stirring Up an Elastic Fluid: Critical Viscosity of Xenon-2 (CVX-2)

Whipped cream stays in place even when turned upside down. Yet it readily flows through the nozzle of a spray can to reach the dessert plate. This demonstrates the phenomenon of shear thinning that is important to many industrial and physical processes. Paints, film emulsions, and other complex solutions that are highly viscous under normal conditions but become thin and flow easily under shear forces. A simple fluid, such as water, does not exhibit shear thinning under normal conditions. Very close to the liquid-vapor critical point, where the distinction between liquid and vapor disappears, the fluid becomes more complex and is predicted to display shear thinning. At the critical point, xenon atoms interact over long distances in a classical model of cooperative phenomena. Physicists rely on this system to learn how long-range order arises. The Critical Viscosity of Xenon Experiment (CVX-2) will measure the viscous behavior of xenon, a heavy inert gas used in flash lamps and ion rocket engines, at its critical point. Although it does not easily combine with other chemicals, its viscosity at the critical point can be used as a model for a range of fluids. Viscosity originates from the interactions of individual molecules. It is so complicated that, except for the simplest gas, it cannot be calculated accurately from theory. Tests with critical fluids can provide key data, but are limited on Earth because critical fluids are highly compressed by gravity. CVX-2 employs a tiny metal screen vibrating between two electrodes in a bath of critical xenon. The vibrations and how they dampen are used to measure viscosity. CVX flew on STS-85 (1997), where it revealed that, close to the critical point, the xenon is partly elastic: it can 'stretch' as well as flow. For STS-107, the hardware has been enhanced to determine if critical xenon is a shear-thinning fluid.

Berg, Robert F.

Surface Tension and Viscosity of SCN and SCN-acetone Alloys at Melting Points and Higher Temperatures Using Surface Light Scattering Spectrometer

Succinonitrile has been and is being used extensively in NASA's Microgravity Materials Science and Fluid Physics programs and as well as in several ground-based and microgravity studies including the Isothermal Dendritic Growth Experiment (IDGE). Succinonitrile (SCN) is useful as a model for the study of metal solidification, although it is an organic material, it has a BCC crystal structure and solidifies dendriticly like a metal. It is also transparent and has a low melting point (58.08 C). Previous measurements of succinonitrile (SCN) and alloys of succinonitrile and acetone surface tensions are extremely limited. Using the Surface Light Scattering technique we have determined non invasively, the surface tension and viscosity of SCN and SCN-Acetone Alloys at different temperatures. This relatively new and unique technique has several advantages over the classical methods such as, it is non invasive, has good accuracy and measures the surface tension and viscosity simultaneously. The accuracy of interfacial energy values obtained from this technique is better than 2% and viscosity about 10 %. Succinonitrile and succinonitrile-acetone alloys are well-established model materials with several essential physical properties accurately known - except the liquid/vapor surface tension at different elevated temperatures. We will be presenting the experimentally determined liquid/vapor surface energy and liquid viscosity of succinonitrile and succinonitrile-acetone alloys in the temperature range from their melting point to around 100 C using this non-invasive technique. We will also discuss about the measurement technique and new developments of the Surface Light Scattering Spectrometer.

Tin, Padetha

Transient Torque Method: A Fast and Non-Intrusive Technique to Simultaneously Determine Viscosity and Electrical Conductivity of Semiconducting and Metallic Melts

A transient torque method was developed to rapidly and simultaneously determine the viscosity and electrical conductivity of semiconducting or metallic melts. The experimental setup is similar to that for the oscillation cup technique. The melt sample is sealed inside a fused silica ampoule, and the ampoule is suspended by a long quartz fiber to form a torsional oscillation system. A rotating magnetic field is used to induce a rotating flow in the conductive melt, which causes the ampoule to rotate along its axis. A sensitive angular detector is used to measure the deflection angle of the ampoule. Based on the transient behavior of the deflection angle as the rotating magnetic field is applied, the electrical conductivity and viscosity of the melt can be obtained simultaneously by numerically fitting the data to a set of governing equations. The transient torque viscometer was applied successfully to measure the viscosity and electrical conductivity of high purity mercury at 53.4 C. The results were in excellent agreement with the published data. The main advantage of the technique is that the measurement can be completed in one or two minutes, as opposed to the one or two-hour measurement time required by the oscillation cup technique. The method is non-intrusive; capable of rapid measurement of the viscosity of toxic, high vapor pressure melts at elevated temperatures. In addition, the transient torque viscometer can also be operated as an oscillation cup viscometer if desired.

Li, C.

Density, Electrical Conductivity and Viscosity of Hg(sub 0.8)Cd(sub 0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt were measures as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(sub 0.8)Cd(sub 0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(sub 0.8)Cd(sub 0.2)Te melt as the temperature was decreased to below 1090 K.

Li, C.

Torque Transient of Magnetically Drive Flow for Viscosity Measurement

Viscosity is a good indicator of structural changes for complex liquids, such as semiconductor melts with chain or ring structures. This paper discusses the theoretical and experimental results of the transient torque technique for non-intrusive viscosity measurement. Such a technique is essential for the high temperature viscosity measurement of high pressure and toxic semiconductor melts. In this paper, our previous work on oscillating cup technique was expanded to the transient process of a magnetically driven melt flow in a damped oscillation system. Based on the analytical solution for the fluid flow and cup oscillation, a semi-empirical model was established to extract the fluid viscosity. The analytical and experimental results indicated that such a technique has the advantage of short measurement time and straight forward data analysis procedures

Ban, Heng

Density, Electrical Conductivity and Viscosity of Hg(0.8)Cd(0.2)Te Melt

The density, viscosity, and electrical conductivity of Hg(0.8)Cd(0.2)Te melt were measured as a function of temperature. A pycnometric method was used to measure the melt density in the temperature range of 1072 to 1122 K. The viscosity and electrical conductivity were determined using a transient torque method from 1068 to 1132 K. The density result from this study is within 0.3% of the published data. However, the current viscosity result is approximately 30% lower than the existing data. The electrical conductivity of Hg(0.8)Cd(0.2)Te melt as a function of temperature, which is not available in the literature, is also determined. The analysis of the temperature dependent electrical conductivity and the relationship between the kinematic viscosity and density indicated that the structure of the melt appeared to be homogeneous when the temperature was above 1090 K. A structural transition occurred in the Hg(0.8)Cd(0.2)Te melt as the temperature was decreased to below 1090 K

Li, C.

Progress on Acoustic Measurements of the Bulk Viscosity of Near-Critical Xenon (BVX)

We plan to determine the bulk viscosity of xenon 10 times closer [in reduced temperature tau = (T-Tc)/Tc] to its liquid-vapor critical point than ever before. (Tc is the critical temperature.) To do so, we must measure the dispersion and attenuation of sound at frequencies 1/100 of those used previously. In general, sound attenuation has contributions from the bulk viscosity acting throughout the volume of the xenon as well as contributions from the thermal conductivity and the shear viscosity acting within thin thermoacoustic boundary layers at the interface between the xenon and the solid walls of the resonator. Thus, we can determine the bulk viscosity only when the boundary layer attenuation is small and well understood. We present a comparison of calculations and measurements of sound attenuation in the acoustic boundary layer of xenon near its liquid-vapor critical point.

Gillis, Keith A.

An Experimental Investigation of the Influence of the Lubricant Viscosity and Additives on Gear Wear

The influence of lubricant viscosity and additives on the average wear rate of spur gear pairs was investigated experimentally. The gear specimens of a comprehensive gear durability test program that made use of seven lubricants covering a range of viscosities were examined to measure gear tooth wear. The measured wear was related to the as-manufactured surface roughness, the elastohydrodynamic film thickness, and the experimentally determined contact fatigue lives of the same specimens. In general, the wear rate was found to be inversely proportional to the viscosity of the lubricant and to the lambda ratio (also sometimes called the specific film thickness). The data also show an exponential trend between the average wear rates and the surface fatigue lives. Lubricants with similar viscosities but differing additives and compositions had somewhat differing gear surface fatigue lives and wear rates.

Krantz, Timothy L.

Fluid Merging Viscosity Measurement (FMVM) Experiment on the International Space Station

The concept of using low gravity experimental data together with fluid dynamical numerical simulations for measuring the viscosity of highly viscous liquids was recently validated on the International Space Station (ISS). After testing the proof of concept for this method with parabolic flight experiments, an ISS experiment was proposed and later conducted onboard the ISS in July, 2004 and subsequently in May of 2005. In that experiment a series of two liquid drops were brought manually together until they touched and then were allowed to merge under the action of capillary forces alone. The merging process was recorded visually in order to measure the contact radius speed as the merging proceeded. Several liquids were tested and for each liquid several drop diameters were used. It has been shown that when the coefficient of surface tension for the liquid is known, the contact radius speed can then determine the coefficient of viscosity for that liquid. The viscosity is determined by fitting the experimental speed to theoretically calculated contact radius speed for the same experimental parameters. Experimental and numerical results will be presented in which the viscosity of different highly viscous liquids were determined, to a high degree of accuracy, using this technique.

Antar, Basil N.

Results of the Fluid Merging Viscosity Measurement International Space Station Experiment

The purpose of FMVM is to measure the rate of coalescence of two highly viscous liquid drops and correlate the results with the liquid viscosity and surface tension. The experiment takes advantage of the low gravitational free floating conditions in space to permit the unconstrained coalescence of two nearly spherical drops. The merging of the drops is accomplished by deploying them from a syringe and suspending them on Nomex threads followed by the astronaut s manipulation of one of the drops toward a stationary droplet till contact is achieved. Coalescence and merging occurs due to shape relaxation and reduction of surface energy, being resisted by the viscous drag within the liquid. Experiments were conducted onboard the International Space Station in July of 2004 and subsequently in May of 2005. The coalescence was recorded on video and down-linked near real-time. When the coefficient of surface tension for the liquid is known, the increase in contact radius can be used to determine the coefficient of viscosity for that liquid. The viscosity is determined by fitting the experimental speed to theoretically calculated contact radius speed for the same experimental parameters. Recent fluid dynamical numerical simulations of the coalescence process will be presented. The results are important for a better understanding of the coalescence process. The experiment is also relevant to liquid phase sintering, free form in-situ fabrication, and as a potential new method for measuring the viscosity of viscous glass formers at low shear rates.

Ethridge, Edwin C.

Investigation of resonant layer response in electron viscosity regime

We present a supplementary study of previous work in Waybright and Park [Phys. Plasmas 31, 022502 (2024)] which demonstrates a substantial effect of electron viscosity on the resonant layer response to non-axisymmetric magnetic perturbations. A main refinement is to include a curl element of electron viscosity in the generalized Ohm's law. The refinement reveals a resonant layer response in the electron viscosity regime corresponding to slowly rotating and highly viscous plasmas.

Asymptotic analysis

Classical and quantum computing of shear viscosity for ( 2 + 1 ) D SU(2) gauge theory

We perform a nonperturbative calculation of the shear viscosity for ( 2 + 1 )-dimensional SU(2) gauge theory by using the lattice Hamiltonian formulation. The retarded Green’s function of the stress-energy tensor is calculated from real time evolution via exact diagonalization of the lattice Hamiltonian with a local Hilbert space truncation, and the shear viscosity is obtained via the Kubo formula. When taking the continuum limit, we account for the renormalization group flow of the coupling but no additional operator renormalization. We find the ratio of the shear viscosity and the entropy density η s is consistent with a well-known holographic result 1 4 π at several temperatures on a 4 × 4 honeycomb lattice with the local electric representation truncated at j max = 1 2 . We also find the ratio of the spectral function and frequency ρ x y ( ω ) ω exhibits a peak structure when the frequency is small. Both the exact diagonalization method and simple matrix product state classical simulation method beyond j max = 1 2 on bigger lattices require exponentially growing resources. So we develop a quantum computing method to calculate the retarded Green’s function and analyze various systematics of the calculation including j max truncation and finite size effects, Trotter errors and the thermal state preparation efficiency. Our thermal state preparation method still requires resources that grow exponentially with the lattice size, but with a very small prefactor at high temperature. We test our quantum circuit on both the Quantinuum emulator and the IBM simulator for a small lattice and obtain results consistent with the classical computing ones. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Sedimentation and shear-induced dynamics of spheroids in fluids with spatial viscosity variations

A generalized reciprocal theorem is used to relate the force and torque induced on a particle in an inertia-less fluid with small variation in viscosity to integrals involving Stokes flow fields and the spatial dependence of viscosity. These resistivity expressions are analytically evaluated using spheroidal harmonics and then used to obtain the mobility of the spheroid during sedimentation, and in linear flows, of a fluid with linear viscosity stratification. The coupling between the rotational and translational motion induced by stratification rotates the spheroid’s centerline, creating a variety of rotational and translational dynamics dependent upon the particle’s aspect ratio, κ, and the component of the stratification unit vector in the gravity direction, d g . Spheroids with 0.55 ⪅ κ ⪅ 2.0 exhibit the largest variety of settling behaviors. Interestingly, this range covers most microplastics and typical microorganisms. One of the modes include a stable orientation dependent only on κ and d g , but independent of initial orientation, thus allowing for the potential control of settling angles and sedimentation rates. In a simple shear flow, cross-streamline migration occurs due to the stratification-induced force generated on the particle. Similarly, a particle no longer stays at the stagnation point of a uniaxial extensional flow. While fully analytical results are obtained for spheroids, numerical simulations provide a source of validation. These simulations also provide additional insights into the stratification-induced force- and torque-producing mechanisms through the stratification-induced stress, which is not accessed in the reciprocal theorem-based analytical calculations.

Geophysical and Geological Flows: Stratified flows

Sustainable Shape Memory Elastomers with Reduced Melt Viscosity and Enhanced Stiffness

Melt reactive processing of lignin with nitrile rubber is a promising approach to synthesizing shape memory materials. The strong intramolecular interactions in lignin macromolecular structures, caused by π–π stacking in aromatic rings and hydrogen bonding, often result in large phase separation or low miscibility with rubbers. In this study, we investigated the chemical and molecular characteristics, as well as the stiffness and complex viscosity, of modified kraft lignin melt-reacted with an acrylonitrile/butadiene copolymer containing 41% acrylonitrile (NBR41). To enhance the macromolecular compatibility of kraft lignin with NBR41, kraft lignin was cross-linked with poly(propylene glycol) diglycidyl ether (PPDE) and trimethylolpropane triglycidyl ether (TTE), both rich in epoxy reactive groups capable of forming chemical bonds with hydroxyl and carboxyl groups. Here, our findings demonstrate that the modification of kraft lignin with PPDE and TTE resulted in significantly increased stiffness of the composites. The elastic modulus of NBR41-Kraft lignin-PPDE and NBR41-Kraft lignin-TTE increased by 82 and 162%, respectively. Both the yield strength and Young’s modulus of these two samples showed dramatic improvements. Specifically, the yield strength and Young’s modulus of NBR41-Kraft lignin-TTE increased nearly 4 and 3-fold, respectively, compared to the control sample. Interestingly, despite significant improvements in mechanical properties, the viscosity of NBR41-Kraft lignin-PPDE was substantially lower than that of the control sample. At 210 °C and an angular frequency of 1 rad/s, the complex viscosity of NBR41-Kraft lignin was approximately 100.25 ± 4.77 kPa·s, while that of NBR41-Kraft lignin-PPDE was significantly lower at 56 ± 0.93 kPa·s. These findings were validated through Fourier transform infrared spectroscopy, scanning electron microscopy, dynamic mechanical analysis, thermal characterization, rheological tests, and quasi-elastic neutron scattering techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH

The ultralow viscosity of volatile-rich kimberlite magma: Implications for the water content of primitive kimberlite melts

The eruption of deeply sourced kimberlite magma offers the fastest route to bring deep-seated volatiles back to the Earth’s surface. However, the viscosity of kimberlite magma, a factor governing its migration and eruption dynamics within Earth, remains poorly constrained. We conducted synchrotron in situ falling sphere viscometry experiments to examine kimberlite magma with different volatile contents (0 to 5 wt % H 2 O and 2 to 8 wt % CO 2 ) under high pressure-temperature conditions. The results reveal that the viscosity of volatile-rich kimberlite magma is ~1 to 2 orders lower than that of mid-ocean ridge basalt (MORB) and comparable to the ultramobile pure carbonate melt. Using the measured viscosity values, we simulated the ascent and eruption process of kimberlite magma. We found that a minimum content of ~0.5 wt % water in the primitive magma is necessary to allow the ultrafast eruption process of kimberlite, thereby enabling the preservation of diamonds and high-pressure mineral inclusions transported by the magma.

58 GEOSCIENCES