Search NASA⌕ Search

SEARCH · Search NASA

Results for “Visible calibration methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A New Approach for Checking and Complementing CALIPSO Lidar Calibration

We have been studying the backscatter ratio of the two CALIPSO wavelengths for 3 different targets. We are showing the ratio of integrate attenuated backscatter coefficient for cirrus clouds, ocean surface and liquid. Water clouds for one month of nightime data (left:July,right:December), Only opaque cirrus classified as randomly oriented ice[1] are used. For ocean and water clouds, only the clearest shots, determined by a threshold on integrated attenuated backscatter are used. Two things can be immediately observed: 1. A similar trend (black dotted line) is visible using all targets, the color ratio shows a tendency to be higher north and lower south for those two months. 2. The water clouds average value is around 15% lower than ocean surface and cirrus clouds. This is due to the different multiple scattering at 532 nm and 1064 nm [2] which strongly impact the water cloud retrieval. Conclusion: Different targets can be used to improve CALIPSO 1064 nm calibration accuracy. All of them show the signature of an instrumental calibration shift. Multiple scattering introduce a bias in liquid water cloud signal but it still compares very well with all other methods and should not be overlooked. The effect of multiple scattering in liquid and ice clouds will be the subject of future research. If there really is a sampling issue. Combining all methods to increase the sampling, mapping the calibration coefficient or trying to reach an orbit per orbit calibration seems an appropriate way.

Josset, Damien B.↗

Method and apparatus for calibrating a display using an array of cameras

The present invention overcomes many of the disadvantages of the prior art by providing a display that can be calibrated and re-calibrated with a minimal amount of manual intervention. To accomplish this, the present invention provides one or more cameras to capture an image that is projected on a display screen. In one embodiment, the one or more cameras are placed on the same side of the screen as the projectors. In another embodiment, an array of cameras is provided on either or both sides of the screen for capturing a number of adjacent and/or overlapping capture images of the screen. In either of these embodiments, the resulting capture images are processed to identify any non-desirable characteristics including any visible artifacts such as seams, bands, rings, etc. Once the non-desirable characteristics are identified, an appropriate transformation function is determined. The transformation function is used to pre-warp the input video signal to the display such that the non-desirable characteristics are reduced or eliminated from the display. The transformation function preferably compensates for spatial non-uniformity, color non-uniformity, luminance non-uniformity, and/or other visible artifacts.

Johnson, Michael J.↗

Quantifying Temperature Dependence of Pu(IV) Absorbance Spectra for Advanced Online Monitoring of Nuclear Processes

This article presents a systematic study of Pu(IV) absorbance spectral features as a function of temperature to develop an understanding of this parameter’s effect on chemometric models that can be used as online monitoring tools to support nuclear processing. The descriptive and predictive models that provide real-time feedback of these processes are usually constructed with data collected in conditions typical of a laboratory environment, which can differ drastically from a processing environment. To assess the impact of temperature on Pu(IV) absorbance spectra, 11 samples of Pu(IV) were synthesized with varying HNO 3 concentrations ranging from 0.6 to 9.5 M and heated between 15 and 45 °C. Ultraviolet (UV)–visible (vis)–near-infrared (NIR) absorption spectra collected at different HNO 3 concentrations and temperatures revealed that features associated with Pu(IV) are sensitive to temperature at all HNO 3 concentrations and that changes in features depend on HNO 3 concentration. The contributions of temperature and HNO 3 concentration to variation in Pu(IV) spectral features were evaluated using the principal component analysis of spectra that were baseline-corrected with an asymmetric least-squares method. Furthermore, predictive modeling for HNO 3 concentration with partial least-squares regression of UV–vis–NIR spectra highlighted the importance of accounting for temperature in the calibration set to optimize model performance. This methodology constitutes a new, systematic approach to account for the effect of temperature on the absorption spectra of metal ions and is useful for process monitoring applications in many industries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of the MODIS and VIIRS Thermal Emissive Band Radiometric Calibration

Moderate Resolution Imaging Spectroradiometer (MODIS) and Visible Infrared Imaging Radiometer Suite (VIIRS) are major instruments for Earth science observations.Nearly 40 MODIS scientific products and a wide range of VIIRS environmental data records are produced using their global observations. The consistency of the MODIS and VIIRS calibrated data is important for the study of Earth science. This article assesses the calibration consistency of the Aqua MODIS and VIIRS thermal emissive band (TEB) data. To remove the impact of the mismatched relative spectral response (RSR) on the comparisons, the simultaneous nadir observation data from the cross-track infrared sounder (CrIS) and the infrared atmospheric sounding interferometer (IASI) are used as references in two different methods to independently verify the consistency. The comparisons of the MODIS and VIIRS TEB calibrated data show that the brightness temperature (BT) differences for comparable bands between MODIS and VIIRS are in general within 0.2 K for BT larger than 230 K. The differences of all comparable MODIS and VIIRS TEBs are consistent over time. MODIS measurements agree better with N20 VIIRS than with Suomi National Polar-orbiting Partnership (S-NPP) VIIRS. The S-NPP VIIRS measurements are higher than N20 VIIRS, within 0.1 Kfor long-wave infrared (LWIR) bands and 0.3 K for band M13.

Calibration↗

Landsat 8 Remote Sensing Reflectance (Rrs) Products: Evaluations, Intercomparisons, and Enhancements

The Operational Land Imager (OLI) onboard Landsat-8 is generating high-quality aquatic science products, the most critical of which is the remote sensing reflectance (Rrs), defined as the ratio of water-leaving radiance to the total downwelling irradiance just above water. The quality of the Rrs products has not, however, been extensively assessed. This manuscript provides a comprehensive evaluation of Level-1B, i.e., top of atmosphere reflectance, and Rrs products available from OLI imagery under near-ideal atmospheric conditions in moderately turbid waters. The procedure includes a) evaluations of the Rrs products at sites included in the Ocean Color component of the Aerosol Robotic Network (AERONET-OC), b) intercomparisons and cross-calibrations against other ocean color products, and c) optimizations of vicarious calibration gains across the entire OLI observing swath. Results indicate that the near-infrared and shortwave infrared (NIR-SWIR) band combinations yield the most robust and stable Rrs retrievals in moderately turbid waters. Intercomparisons against products derived from the Visible Infrared Imaging Radiometer Suite (VIIRS) and the Moderate Resolution Imaging Spectroradiometer onboard the Aqua platform (MODISA) indicate slight across-track non-uniformities (<1%) associated with OLI scenes in the blue bands. In both product domains (TOA and Rrs), on average, the OLI products were found larger in radiometric responses in the blue channels. Following the implementation of updated vicarious calibration gains and accounting for across-track non-uniformities, matchup analyses using independent in-situ validation data confirmed improvements in Rrs products. These findings further support high-fidelity OLI-derived aquatic science products in terms of both demonstrating a robust atmospheric correction method and providing consistent products across OLI's imaging swath.

Pahlevan, Nima↗

Deconvolution of SNPP VIIRS Solar Diffuser Bidirectional Reflectance Distribution Function On-orbit Change Factor

The Earth-observing Visible Infrared Imaging Radiometer Suite (VIIRS) on the Suomi National Polar-orbiting Partnership satellite regularly calibrates its reflective solar bands (RSBs), primarily through observing an onboard sunlit solar diffuser (SD). The on-orbit change of the value of the SD bidirectional reflectance distribution function (BRDF) is quantified by a numerical factor, called the H-factor, and is determined by the onboard SD stability monitor (SDSM). Because the spectral response function of an SDSM detector spreads in wavelength, the directly measured H-factor is the true H-factor convolved with the spectral response function. To find the true H-factor, we use the traditional direct method and an innovative iterative approach to separately deconvolve the measured H-factor. Our iterative approach relies on two properties of the SDSM detector spectral response function: the central peak width is narrow enough so that the H-factor does not change much over the peak width, and the dominance of the spectral response function’s integral with respect to the wavelength over the width. The iterative approach is more accurate, of a smaller noise impact, much more flexible in terms of interpolation and extrapolation of function values, and faster. We have used deconvolved H-factors to calibrate the NASA SNPP VIIRS RSB Collections 1 and 2 Level-1B products.

SNPP VIIRS↗

Assessment, Validation, and Refinement of the Atmospheric Correction Algorithm for the Ocean Color Sensors

The primary focus of this proposed research is for the atmospheric correction algorithm evaluation and development and satellite sensor calibration and characterization. It is well known that the atmospheric correction, which removes more than 90% of sensor-measured signals contributed from atmosphere in the visible, is the key procedure in the ocean color remote sensing (Gordon and Wang, 1994). The accuracy and effectiveness of the atmospheric correction directly affect the remotely retrieved ocean bio-optical products. On the other hand, for ocean color remote sensing, in order to obtain the required accuracy in the derived water-leaving signals from satellite measurements, an on-orbit vicarious calibration of the whole system, i.e., sensor and algorithms, is necessary. In addition, it is important to address issues of (i) cross-calibration of two or more sensors and (ii) in-orbit vicarious calibration of the sensor-atmosphere system. The goal of these researches is to develop methods for meaningful comparison and possible merging of data products from multiple ocean color missions. In the past year, much efforts have been on (a) understanding and correcting the artifacts appeared in the SeaWiFS-derived ocean and atmospheric produces; (b) developing an efficient method in generating the SeaWiFS aerosol lookup tables, (c) evaluating the effects of calibration error in the near-infrared (NIR) band to the atmospheric correction of the ocean color remote sensors, (d) comparing the aerosol correction algorithm using the singlescattering epsilon (the current SeaWiFS algorithm) vs. the multiple-scattering epsilon method, and (e) continuing on activities for the International Ocean-Color Coordinating Group (IOCCG) atmospheric correction working group. In this report, I will briefly present and discuss these and some other research activities.

Wang, Menghua↗

Initial Assessment of Radiometric Performance of N20 VIIRS Reflective Solar Bands Using Vicarious Approaches

The newly launched (November 18, 2017) polar-orbiting satellite of the Joint Polar Satellite System (JPSS-1), now transitioned to NOAA-20, is the follow-on mission to the SNPP (Suomi National Polar-orbiting Partnership) satellite, launched six years ago. NOAA-20 leads SNPP by a half orbit or about 50 minutes. The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor onboard both NOAA-20 and SNPP spacecraft with nearly identical band spectral responses. Similar to the heritage sensor MODIS, VIIRS has on-board calibration components including a solar diffuser (SD) and a solar diffuser stability monitor (SDSM) for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view (SV) as background reference for calibration. This study provides an initial assessment of calibration of the NOAA-20 VIIRS reflective solar bands (RSB) by inter-comparison with measurements from SNPP VIIRS using various vicarious approaches. The first approach is based on a double difference method using observations from simultaneous nadir overpasses (SNO) with Aqua MODIS. The second is from the collected reflectances over the widely used Liby-4 desert site from 16-day repeatable orbits so each data point has the same viewing geometry relative to the site. The third approach is to use the frequent overpasses over the Dome C snow site. Results of this study provide useful information on NOAA-20 VIIRS post-launch calibration assessment and preliminary analysis of its calibration stability and consistency for the first 6 months

Wu, Aisheng↗

Radiometric gains of satellite sensors of reflected solar radiation - Results from NASA ER-2 aircraft measurements

A method for using congruent aircraft-satellite observations to calibrate a satellite sensor is presented. A calibrated spectroradiometer at an altitude of 19 km above White Sands, NM, is oriented to view White Sands at the satellite overpass time along the same view vector as the satellite sensor. Collected data are transformed into corresponding estimates of sensor band radiance at the satellite (derived from the aircraft measurements), and average count (from the sensor measurements). These are both averaged across the footprint of the spectroradiometer. Results are presented for the evolution of NOAA-11 Advanced Very High Resolution Radiometer (AVHRR) (Bands 1 and 2) gain between November 1988 and October 1990, and for GOES-6 and GOES-7 VISSR/VAS visible bands during the same period. Estimates of uncertainty in the results are presented, as well as ideas for their reduction in future flights.

Abel, Peter↗

NASA Tech Briefs, Februrary 2013

Topics covered include: Measurements of Ultra-Stable Oscillator (USO) Allan Deviations in Space; Gaseous Nitrogen Orifice Mass Flow Calculator; Validation of Proposed Metrics for Two-Body Abrasion Scratch Test Analysis Standards; Rover Low Gain Antenna Qualification for Deep Space Thermal Environments; Automated, Ultra-Sterile Solid Sample Handling and Analysis on a Chip; Measuring and Estimating Normalized Contrast in Infrared Flash Thermography; Spectrally and Radiometrically Stable, Wideband, Onboard Calibration Source; High-Reliability Waveguide Vacuum/Pressure Window; Methods of Fabricating Scintillators With Radioisotopes for Beta Battery Applications; Magnetic Shield for Adiabatic Demagnetization Refrigerators (ADR); CMOS-Compatible SOI MESFETS for Radiation-Hardened DC-to-DC Converters; Silicon Heat Pipe Array; Adaptive Phase Delay Generator; High-Temperature, Lightweight, Self-Healing Ceramic Composites for Aircraft Engine Applications; Treatment to Control Adhesion of Silicone-Based Elastomers; High-Temperature Adhesives for Thermally Stable Aero-Assist Technologies; Rockballer Sample Acquisition Tool; Rock Gripper for Sampling, Mobility, Anchoring, and Manipulation; Advanced Magnetic Materials Methods and Numerical Models for Fluidization in Microgravity and Hypogravity; Data Transfer for Multiple Sensor Networks Over a Broad Temperature Range; Using Combustion Synthesis to Reinforce Berms and Other Regolith Structures; Visible-Infrared Hyperspectral Image Projector; Three-Axis Attitude Estimation With a High-Bandwidth Angular Rate Sensor Change_Detection.m; AGATE: Adversarial Game Analysis for Tactical Evaluation; Ionospheric Simulation System for Satellite Observations and Global Assimilative; Modeling Experiments (ISOGAME); An Extensible, User- Modifiable Framework for Planning Activities; Mission Operations Center (MOC) - Precipitation Processing System (PPS) Interface Software System (MPISS); Automated 3D Damaged Cavity Model Builder for Lower Surface Acreage Tile on Orbiter; Mixed Linear/Square-Root Encoded Single-Slope Ramp Provides Low-Noise ADC with High Linearity for Focal Plane Arrays; RUSHMAPS: Real-Time Uploadable Spherical Harmonic Moment Analysis for Particle Spectrometers; Powered Descent Guidance with General Thrust-Pointing Constraints; X-Ray Detection and Processing Models for Spacecraft Navigation and Timing; and Extreme Ionizing-Radiation-Resistant Bacterium

Source record↗

Evaluation of NOAA-20 VIIRS reflective solar bands calibration performance using vicarious approaches

The newly launched polar-orbiting NOAA-20 satellite is the follow-on mission to the SNPP (Suomi National Polar-orbiting Partnership) satellite. Both satellites are in an afternoon orbit with a close equatorial cross time. The Visible Infrared Imaging Radiometer Suite (VIIRS) is a key sensor onboard NOAA-20 and SNPP. The two VIIRS sensors are within the same engineering design with nearly identical spectral ranges. Its on-board calibration components include a solar diffuser and a solar diffuser stability monitor for the reflective solar bands (RSB), a V-groove blackbody for the thermal emissive bands (TEB), and a space view as background reference. This study evaluates calibration performance of the NOAA-20 VIIRS RSB using the first internally released L1B data product by NASA Land SIPS, which has consistent calibration coefficient look up tables (LUT) throughout the entire mission. Several independent vicarious approaches are used to examine the stability and consistence of reflectance. The first approach is based on a double difference method by comparison with SNPP VIIRS using observations from simultaneous nadir overpasses (SNO) with Aqua MODIS. The second is based on the reflectance trends from 16-day repeatable orbits obtained over the widely used Liby-4 desert site so each data point has the nearly same viewing angles relative to the site. The third approach is to use the frequent overpasses over the Dome C snow site. Results of this study provide NOAA-20 VIIRS post-launch calibration stability performance and radiometric agreement with SNPP for the first 18 months of mission.

VIIRS↗

A Method for Rapid Measurement of Contrast Sensitivity on Mobile Touch-Screens

Touch-screen displays in cell phones and tablet computers are now pervasive, making them an attractive option for vision testing outside of the laboratory or clinic. Here we de- scribe a novel method in which subjects use a finger swipe to indicate the transition from visible to invisible on a grating which is swept in both contrast and frequency. Because a single image can be swiped in about a second, it is practical to use a series of images to zoom in on particular ranges of contrast or frequency, both to increase the accuracy of the measurements and to obtain an estimate of the reliability of the subject. Sensitivities to chromatic and spatio-temporal modulations are easily measured using the same method. A proto- type has been developed for Apple Computer's iPad/iPod/iPhone family of devices, implemented using an open-source scripting environment known as QuIP (QUick Image Processing, http://hsi.arc.nasa.gov/groups/scanpath/research.php). Preliminary data show good agreement with estimates obtained from traditional psychophysical methods as well as newer rapid estimation techniques. Issues relating to device calibration are also discussed.

contrast sensitivity↗

Method and apparatus for instantaneous band ratioing in a reflectance radiometer

A hand-held instrument is provided to compare information from selected infrared and visible bands in the 0.4 to 2.5 micrometer range, to perform ratioing via a dividing circuit (17) and to directly read out, via a display system (18), ratio values in a continuous digital display. The dual-beam, ratioing radiometer contains two optical trains (10, 12), each having two repeater lenses (L1a, L1b and L2a, L2b) and a cooled lead sulfide detector (D1, D2). One of the trains (10) is pivotal to facilitate measurements at distances ranging from about 1 meter to infinity. The optical trains are intersected by a set of two coaxially-mounted filter wheels (F1, F2), each containing up to five interference filters and slits to pass radiation filtered by the other. Filters with band passes as narrow as 0.01 micrometer are used in the region 0.4 to 2.5 micrometers. The total time for a calibration and measurement is only a few seconds. It is known from previous field studies using prior art devices, that materials, e.g., clay minerals, and carbonate minerals such as limestone, have unique spectral properties in the 2.0 to 2.5 micrometer region. Using properly chosen spectral filters, and ratioing the signals to remove the effect of topography on the brightness measured, the instrument can be used for real-time analysis of reflecting materials in the field. Other materials in the broader range of 0.4 to 2.5 micrometers (and even beyond) could be similarly identified once the reflectance spectrum of the material is established by any means.

Goetz, Alexander F. H.↗

CLARREO Pathfinder Mission Overview and its Intercalibration Capabilities

NASA's Climate Absolute Radiance and Refractivity Observatory (CLARREO) Pathfinder (CPF) mission will deploy an Earth-observing reflected solar (RS) spectrometer, designed to measure Earth-reflected solar radiation from the International Space Station with a remarkable SI-traceable radiometric uncertainty of 0.3% (k=1). This spectrometer, known as the Hyperspectral Imager for Climate Science (HySICS), will provide measurements within a spectral range of 350-2300 nm with 3-nm spectral intervals. Covering a nadir swath of 70 km, HySICS captures 480 discrete measurement pixels that provide spectrally-resolved Earth-reflected radiances. The CPF mission encompasses two principal objectives. The first objective is to demonstrate on-orbit calibration methodologies that achieve and uphold an unprecedented level of accuracy while maintaining traceability to SI standards. The second objective is to showcase an innovative on-orbit intercalibration approach, which involves the intercalibration of two other RS sensors—namely, the shortwave (SW) channel of the Clouds and the Earth’s Radiant Energy System (CERES) and the Reflective Solar (RS) bands of the Visible Infrared Imager Radiometer Suite (VIIRS)—against CPF benchmark measurements. The targeted intercalibration methodology uncertainty for these target instruments is 0.3% (k=1). Empowered by the CPF payload's two-axis pointing capability, moderate spatial sampling of 0.5 km, and wide spectral coverage, the CPF instrument will capture near-simultaneous temporal, spatial, angular, and spectrally matched observations with intercalibration targets. The CPF intercalibration science development team has devised novel methods to address spatial, spectral, polarization, and angular differences between CPF and the target instruments' intercalibration footprints to achieve the stringent 0.3% intercalibration methodology uncertainty. Comprehensive details of these methods and their validation will be elaborated upon during the conference presentation.

Hyperspectral↗

Radiometric calibration and monitoring of NOAA AVHRR visible data

Results and corrections to calibration for the NOAA-7, -8, -9, -10, and -11 AVHRR Channel 1 data, covering the period from July 1983 through December 1989, are presented. Results from the NOAA-7 and NOAA-9 analysis are used as examples to illustrate key points and present detailed results. In the AVHRR monitor procedure, the spatial variability index is calculated first to classify the data as CLEAR or CLOUD. This classification is then used to sort the data to produce three 1D radiance histograms for different surface types. The surface reflectances are retrieved from the radiances, and a set of reflectance filters are applied to sort the data into global surface reflectance maps. An examination of the NOAA-7 results shows that the NOAA-7 radiometer sensitivity actually decreased at a rate of about 0.5-1.0 percent per year. Trends inferred from the point measurements representing independent calibrations at different times, using models, known sites, and coincident aircraft measurements, agree well with the satellite methods.

Brest, Christopher L.↗

Center Director's Discretionary Fund 2005 Annual Report

The FY 2005 CDDF projects were selected from the following spaceport and range technology and science areas: fluid system technologies; spaceport structures and materials; command, control, and monitoring technologies; and biological sciences (including support for environmental stewardship). The FY 2005 CDDF research projects involved development of the following: a) Capacitance-based moisture sensors to optimize plant growth in reduced gravity; b) Commodity-free calibration methods; c) Application of atmospheric plasma glow discharge to alter the surface properties of polymers for improved electrostatic dissipation characteristics; d) A wipe-on, wipe-off chemical process to remove lead oxides found in paint; e) A robust metabolite profiling platform for better understanding the "law" of biological regulation; f) An explanation of the excavation processes that occur when a jet of gas impinges on a bed of sand; g) "Smart coatings" to detect and control corrosion at an early stage to prevent further corrosion h) A model that can produce a reliable diagnosis of the quality of a software product; i) The formulation of advanced materials to meet system safety needs to minimize electrostatic charges, flammability, and radiation exposure; j) A lab-based instrument that uses the electro-optic Pockels effect to make static electric fields visible; k) A passive volatile organic compound (VOC) cartridge to filter, identify, and quantify VOCs flowing into or emanating from plant flight experiments.

Nurge, Mark↗

JACIE Radiometric Assessment of QuickBird Multispectral Imagery

Radiometric calibration of commercial imaging satellite products is required to ensure that science and application communities can place confidence in the imagery they use and can fully understand its properties. Inaccurate radiometric calibrations can lead to erroneous decisions and invalid conclusions and can limit intercomparisons with other systems. To address this calibration need, the NASA Stennis Space Center (SSC) Earth Science Applications (ESA) directorate,through the Joint Agency for Commercial Imagery Evaluation (JACIE) framework, established a commercial imaging satellite radiometric calibration team consisting of two groups: 1) NASA SSC ESA, supported by South Dakota State University, and 2) the University of Arizona Remote Sensing Group. The two groups determined the absolute radiometric calibration coefficients of the Digital Globe 4-band, 2.4-m QuickBird multispectral product covering the visible through near-infrared spectral region. For a 2-year period beginning in 2002, both groups employed some variant of a reflectance-based vicarious calibration approach, which required ground-based measurements coincident with QuickBird image acquisitions and radiative transfer calculations. The groups chose several study sites throughout the United States that covered nearly the entire dynamic range of the QuickBird sensor. QuickBird at-sensor radiance values were compared with those estimated by the two independent groups to determine the QuickBird sensor's radiometric accuracy. Approximately 20 at-sensor radiance estimates were vicariously determined each year. The estimates were combined to provide a high-precision radiometric gain calibration coefficient. The results of this evaluation provide the user community with an independent assessment of the QuickBird sensor's absolute calibration and stability over the 2-year period. While the techniques and method described reflect those developed at the NASA SSC, the results of both JACIE team groups are included in this paper.

Pagnutti, Mary↗

Thin-Filament Pyrometry Developed for Measuring Temperatures in Flames

Many valuable advances in combustion science have come from observations of microgravity flames. This research is contributing to the improved efficiency and reduced emissions of practical combustors and is benefiting terrestrial and spacecraft fire safety. Unfortunately, difficulties associated with microgravity have prevented many types of measurements in microgravity flames. In particular, temperature measurements in flames are extremely important but have been limited in microgravity. A novel method of measuring temperatures in microgravity flames is being developed in-house at the National Center for Microgravity Research and the NASA Glenn Research Center and is described here. Called thin-filament pyrometry, it involves using a camera to determine the local gas temperature from the intensity of inserted fibers glowing in a flame. It is demonstrated here to provide accurate measurements of gas temperatures in a flame simultaneously at many locations. The experiment is shown. The flame is a laminar gas jet diffusion flame fueled by methane (CH4) flowing from a 14-mm round burner at a pressure of 1 atm. A coflowing stream of air is used to prevent flame flicker. Nine glowing fibers are visible. These fibers are made of silicon carbide (SiC) and have a diameter of 15 m (for comparison, the average human hair is 75 m in diameter). Because the fibers are so thin, they do little to disturb the flame and their temperature remains close to that of the local gas. The flame and glowing filaments were imaged with a digital black-and-white video camera. This camera has an imaging area of 1000 by 1000 pixels and a wide dynamic range of 12 bits. The resolution of the camera and optics was 0.1 mm. Optical filters were placed in front of the camera to limit incoming light to 750, 850, 950, and 1050 nm. Temperatures were measured in the same flame in the absence of fibers using 50-m Btype thermocouples. These thermocouples provide very accurate temperatures, but they generally are not useful in microgravity tests because they measure temperature at only one location at a time. Thermocouple measurements at a height of 11 mm above the burner were used to calibrate the thin-filament pyrometry system at all four wavelengths. This calibration was used to perform thin-filament pyrometry at other heights above the burner. One such profile is shown in this graph; this is for a height of 21 mm. The agreement between the pyrometry measurements and thermocouple results at this height is excellent in the range of 1000 to 2000 K, with an estimated uncertainty of 50 K and an estimated upper limit of 2500 K. Neither the thermocouple nor the thin-filament pyrometry temperatures have been corrected for radiation, but the correction is expected to be nearly the same for both methods. We anticipate that thin-filament pyrometry similar to that developed here will become an important diagnostic for studies of microgravity flames owing to its accuracy and its ability to simultaneously measure finely spaced temperatures.

Sunderland, Peter B.↗