Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile collection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

W T Wallace↗

Differential Mobility Spectrometry on the ISS: Successes and Current Concerns

With the construction of the International Space Station (ISS), crew members moved from the relatively short flights of the Space Shuttle (~ 2 weeks) to missions lasting months to a year. As such, environmental monitoring needs also changed, transitioning from a reliance on archival sampling to a combination of archival sampling and in-flight data collection. In the case of trace volatile organic compound (VOC) monitoring, this in-flight monitoring was performed early on by the Volatile Organic Analyzer (VOA), a gas chromatograph-ion mobility spectrometer, which operated on the ISS for 7 years. This large, fixed-position analyzer was replaced by Air Quality Monitors (AQMs), a pair of small gas chromatograph-differential mobility spectrometers, in the spring of 2013. During their initial half decade of use, and covering multiple sets of units, the AQMs performed well, meeting all of their validation criteria and generally showing excellent accuracy when compared to the now-reduced archival samples. These instruments were also used to perform a survey of the US Operating Segment (US Lab Module, European Columbus Module, and Japanese Pressurized Module), confirming that the atmosphere in this segment is well-mixed. The AQMs were also able to provide important information in contingency situations, such as confirming that no ammonia was present on the ISS following alarms suggesting that the coolant loops had leaked in January 2015. As the fleet of AQMs has aged, though, issues of concern have arisen. These have ranged from pervasive electronics board problems to loss of sensitivity due to carbon dioxide to incorrect identification of compounds. Some of these issues are unavoidable due to the nature of the AQM’s use and preparation prior to flight. However, with the extension of the ISS to 2030 (well past its original 2024 lifetime), the fleet of AQMs will be asked to perform longer, requiring solutions to some of the inherent problems. In this presentation, we will discuss the history of the AQM on the ISS with a focus on more recent results. These results show both the continued usefulness of the AQM for atmospheric monitoring and also the current concerns, including: 1) the incorrect identification of benzene, 2) reporting of elevated isopropanol concentrations, and 3) the loss of the reactant ion peak (RIP) that must be resolved in order for the instrument to continue to serve as the primary trace VOC monitor on the ISS.

William T. Wallace↗

Volatiles in interplanetary dust particles

Interplanetary dust particles (IDP's) collected by specially equipped aircraft flying in the stratosphere have generated a lot of interest during the last decade. These particles, consisting of primitive materials originating in small solar system bodies such as comets and asteroids, are complex heterogeneous species with a variety of components. In order to understand the past histories of IDP's, it is particularly important to know the nature of the volatiles present. Volatiles released from a number of IDP's have been studied; however, a large number of particles must be studied in order to establish trends, to classify types of IDP's, and to have comparison data for determining the origins of IDP's. This study involves the analysis of six IDP's using laser microprobe mass spectrometry.

Bustin, Roberta↗

LAVA Subsystem Integration and Testing for the RESOLVE Payload of the Resource Prospector Mission: Mass Spectrometers and Gas Chromatography

The Regolith and Environment Science & Oxygen and Lunar Volatile Extraction (RESOLVE) payload is part of Resource Prospector (RP) along with a rover and a lander that are expected to launch in 2020. RP will identify volatile elements that may be combined and collected to be used for fuel, air, and water in order to enable deeper space exploration. The Resource Prospector mission is a key part of In-Situ Resource Utilization (ISRU). The demand for this method of utilizing resources at the site of exploration is increasing due to the cost of resupply missions and deep space exploration goals. The RESOLVE payload includes the Lunar Advanced Volatile Analysis (LAVA) subsystem. The main instrument used to identify the volatiles evolved from the lunar regolith is the Gas Chromatograph-Mass Spectrometer (GC-MS). LAVA analyzes the volatiles emitted from the Oxygen and Volatile Extraction Node (OVEN) Subsystem. The objective of OVEN is to obtain, weigh, heat and transfer evolved gases to LAVA through the connection between the two subsystems called the LOVEN line. This paper highlights the work completed during a ten week internship that involved the integration, testing, data analysis, and procedure documentation of two candidate mass spectrometers for the LAVA subsystem in order to aid in determining which model to use for flight. Additionally, the examination of data from the integrated Resource Prospector '15 (RP' 15) field test will be presented in order to characterize the amount of water detected from water doped regolith samples.

RESOLVE↗

Lunar Advanced Volatile Analysis Integration and Testing

The Regolith and Environment Science Oxygen and Lunar Volatile Extraction (RESOLVE) payload is part of Resource Prospector (RP) along with a rover and a lander that are expected to launch in 2020. RP will identify volatile elements that may be combined and collected to be used for fuel, air, and water in order to enable deeper space exploration. The Resource Prospector mission is a key part of In-Situ Resource Utilization (ISRU). The demand for this method of utilizing resources at the site of exploration is increasing due to the cost of resupply missions and deep space exploration goals. The RESOLVE payload includes the Lunar Advanced Volatile Analysis (LAVA) subsystem. The main instrument used to identify the volatiles evolved from the lunar regolith is the Gas Chromatograph-Mass Spectrometer (GC-MS). LAVA analyzes the volatiles emitted from the Oxygen and Volatile Extraction Node (OVEN) Subsystem. The objective of OVEN is to obtain, weigh, heat and transfer evolved gases to LAVA through the connection between the two subsystems called the LOVEN line. This paper highlights the work completed during a ten week internship that involved the integration, testing, data analysis, and procedure documentation of two candidate mass spectrometers for the LAVA subsystem in order to aid in determining which model to use for flight. Additionally, the examination of data from the integrated Resource Prospector '15 (RP' 15) field test will be presented in order to characterize the amount of water detected from water doped regolith samples.

In-Situ Resource Utilization↗

Volatile products from the interaction of KCl/g/ with Cr2O3 and LaCrO3 in oxidizing environments

Based on cooled target collection methods and high pressure mass spectrometer sampling, oxidative vaporization rates and emanating volatile products were evaluated for interactions of KCl(g) with Cr2O3 and LaCrO3 in oxidizing environments. It was found that: (1) increased rates of oxidative vaporization upon exposure to the reactants are exhibited by chromia and fresh lanthanum chromite samples, and (2) these increased rates result from the heterogeneous formation of complex molecules such as KCl sub 1,2,3CrO3 and KOH sub 1,2CrO3. No increased rates were observed for lanthanum chromite subjected to prolonged oxidative vaporization.

Kohl, F. J.↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Components Refurbishment and Chemical Analysis Facility, SWMU #041 - Per- and Polyfluoroalkyl Substances Site Assessment Report Kennedy Space Center, Florida

This PFAS Site Assessment (SA) Report presents the activities and results associated with PFAS investigations at the Components Refurbishment and Chemical Analysis (CRCA) facility located at Kennedy Space Center (KSC), Florida. In 2022, CRCA was identified as an Area of Potential Concern because the facility stores several potential PFAS-containing chemicals. A groundwater sample collected from an onsite monitoring well detected PFOA and PFOS at concentrations greater than State of Florida provisional Groundwater Cleanup Target Levels (pGCTLs). PFAS SA activities were conducted between March 2022 and February 2024. During this timeframe, a total of 16 direct-push technology (DPT) locations and 82 discrete samples were collected from these locations, along with 90 monitoring well samples. The analytical data screening process focused on State of Florida pGCTLs and United States Environmental Protection Agency (USEPA) Regional Screening Level (RSLs) from November 2023 to evaluate the data. Analytical results identified PFOS, PFOA, and PFBA at concentrations exceeding their respective RSLs at each depth interval (shallow, intermediate, and deep). PFOS and PFOA had the largest footprint of RSL exceedances in each depth interval, but pGCTL exceedances were only observed at limited locations in the shallow and intermediate intervals. PFBA had the highest detections of any PFAS compound, with concentrations exceeding 180,000 nanograms per liter (ng/L), which is 100-times the RSL of 1,800 ng/L in the shallow and intermediate intervals and 10-times the RSL in the deep interval. The maximum PFBA detection was 841,000 ng/L at shallow monitoring well, MW0006. The PFAS SA also included samples collected from the onsite hydraulic containment system (HCS) which was installed to control and treat the onsite chlorinated volatile organic compound (CVOC) plume. Influent and effluent aqueous samples were collected monthly from the system. PFAS concentrations were relatively the same for both influent and effluent samples, indicating that while the HCS has been effective for CVOC treatment, it does not provide any additional treatment for PFAS compounds. Since the HCS has achieved its objectives, the system was shut down in December 2024. PFAS data gaps still exist, to include surface water and soil, which were not sampled during this SA. Soil sampling near the Chemical Process Area is recommended. Surface water and soil sampling at select stormwater outfalls is also recommended. Additionally, further groundwater sampling is recommended (DPT and monitoring well) in all depth intervals to delineate the extent of PFAS impacts at CRCA.

K Alex Murphy↗

JSC Stardust Curation Team

STARDUST, a NASA Discovery-class mission, is the first to return samples from a comet. Grains from comet Wild 2's coma-the gas and dust envelope that surrounds the nucleus-will be collected as well as interstellar dust. The mission which launched on February 7, 1999 will encounter the comet on January 10, 2004. As the spacecraft passes through the coma, a tray of silica aerogel will be exposed, and coma grains will impact there and become captured. Following the collection, the aerogel tray is closed for return to Earth in 2006. A dust impact mass spectrometer on board the STARDUST spacecraft will be used to gather spectra. of dust during the entire mission, including the coma passage. This instrument will be the best chance to obtain data on volatile grains, which will not be well-collected in the aerogel. The dust impact mass spectrometer will also be used to study the composition of interstellar grains. In the past 5 years, analysis of data from dust detectors aboard the Ulysses and Galileo spacecraft have revealed that there is a stream of interstellar dust flowing through our solar system. These grains will be captured during the cruise phase of the STARDUST mission, as the spacecraft travels toward the comet. The sample return capsule will parachute to Earth in February 2006, and will land in western Utah. Once on y the ground, the sample return capsule will be placed into a dry nitrogen environment and flown to the curation lab at JSC.

Zolensky, Michael E.↗

Atmospheric aerosol measurement problems

The present knowledge of the atmospheric aerosols is summarized briefly with respect to geographical distribution, time variations, optical properties, chemical nature, and natural and artificial sources. The measurement techniques for determining aerosol properties are summarized with the limitations and results from each. The problems resulting from variations in refractive index, shape, composition, volatile constituents, relative humidity and time from collection until measurement are described. Needed measurements on atmospheric aerosols are outlined with some of the latest methods for obtaining them, including the needs and goals of some world-wide programs.

Harris, F. S., Jr.↗

Hydrogen and carbon isotopic composition of volatiles in Nakhla: Implications for weathering on Mars

Gases were collected at 120, 200, 300, 415, and 600 and 850 C. Hydrogen yields for the 600 and 850 C aliquots were measured separately and then the gases were combined for isotopic analysis. CO2 samples collected at the two lowest temperature steps amounted to less than 0.5 mu mole and were not analyzed isotopically. Excluding the 120 C temperature step, the bulk delta D of the sample was + 187 percent. Delta D values increase from -91 percent in the 120 C step to +518 percent in the 315 to 850 C step. The hydrogen content is greatest in the 120 C step and is roughly constant in the 200, 300, and 415 C aliquots. Between 415 C and 850 C, the yield drops off considerably. From 850 C to 950 C, virtually no H2 and only minor CO2 (less than 1 mu mole) were extracted. Using the isotopic analysis from the 300, 415, 600, and 850 C temperature collections, the bulk delta C-13 sub (PDB) is 0.0 percent. The heaviest component (delta C-13 sub (PDB) of +29 percent) was collected between 300 and 415 C. The release of hydrogen at the low temperatures reported here is consistent with the breakdown of the phases that constitute the alteration product between approx. 250 and 650 C. Although not as high as the present Martian atmosphere, the high delta D values are consistent with a Martian origin for the meteorites in question.

Watson, L. L.↗

Preparation and Testing of Ice-Enriched Lunar Regolith Simulant for RESOLVE OVEN

The RESOLVE (Regolith and Environment Science and Oxygen and Lunar Volatile Extraction) project seeks to deploy a robotic ISRU lander at the lunar south pole to determine the accessibility of frozen ice and the resource potential at various locations. The OVEN (Oxygen and Volatiles Extraction Node) component will be used to heat samples to 150 C or higher in order to drive off ice and other volatiles, which will then be identified and measured. An ice volatilization system has been developed to specifically collect data on the extraction of water vapor from a sample. Testing of the system was begun in April of this year. This report addresses our current work to test the system in a relevant environment in this case, using simulants with up to 10wt% water ice at 76K, in reduced atmosphere.

Cooper, Bonnie↗

In situ extraction and analysis of volatiles and simple molecules in interplanetary dust particles, contaminants, and silica aerogel

Results are presented for the analyses of eight interplanetary dust particles (IDPs) for the volatile elements H, C, N, O, and S and their molecular species, as well as of the volatiles associated with contaminants (i.e., the compounds used during the collection and curation of IDPs), which were carried out using a laser microprobe interfaced with a quadrupole mass spectrometer. It was found that the volatile species from contaminants were always present in the spectra of IDPs. Despite the contamination problems, several indigenous molecular species could be identified, including OH, CO2 or C2H4, C and CS2, CO2 along with CO (possibly indicating the presence of carbonate), H2S, SO, COS, SO2, and CS2. In some cases, the sulfur components can be attributed to aerosols; however, in one of the IDPs, the presence of H2S, SO, COS, and SO2 indicates the possible presence of elemental sulfur.

Hartmetz, C. P.↗

Microwave AeroGel Volatile Collector (MAGVC) Aerogel and Microwave Radiation Study

The MAGVC is a volatile extraction system that uses microwave radiation to sublimate and collect water trapped in regolith on the lunar surface It is comprised of: - Microwave source (magnetron) - Aerogel-insulated chamber (depicted as a dome) - Volatile storage system (depicted as 4 tanks) - Autonomous operating system

Aerogel↗

Search for organic and volatile inorganic compounds in two surface samples from the Chryse Planitia region of Mars

Two surface samples collected from the Chryse Planitia region of Mars were heated to temperatures up to 500 C, and the volatiles that they evolved were analyzed with a gas chromatograph-mass spectrometer. Only water and carbon dioxide were detected. This implies that organic compounds have not accumulated to the extent that individual components could be detected at levels of a few parts per billion by weight in the samples. Proposed mechanisms for the accumulation and destruction of organic compounds are discussed in the light of this limit.

Biemann, K.↗

Investigating Bennu’s Volatile Accretion History Through Step-Heating N-Ne-Ar Analyses of Single Aggregate Particles

NASA’s OSIRIS-REx spacecraft delivered a sample from the carbonaceous asteroid (101955) Bennu to Earth on September 24, 2023. Since Bennu presumably accreted in the outer protoplanetary disk, beyond Jupiter’s orbit, the collected material is expected to be rich in highly volatile elements such as H, C, N, and noble gases—similar to Ivuna-type (CI) carbonaceous chondrites and material from asteroid (162173) Ryugu returned by JAXA’s Hayabusa2 spacecraft. This type of material may have contributed to the volatile inventory of Earth and the other terrestrial planets. Bulk CI chondrites record a narrow range of δ 15 N values (i.e., the permil difference from the atmospheric 15 N/ 14 N ratio), averaging between +42 and 49‰. In contrast, recent analyses at CRPG’s noble gas facility revealed that two pelletized Ryugu samples have lower δ 15 N values of +18.1 ± 0.9‰ and +19.5 ± 0.9‰. Together with the low measured N abundances, this observation suggests that Ryugu has lost a 15 N-rich, labile organic phase due to pervasive aqueous alteration. Subsequent high-resolution step-heating analyses of an additional Ryugu particle demonstrated that the δ 15 N value varies significantly during successive extraction steps (between +1.0 ± 1.0‰ and 65.8 ± 1.1‰); the variable N isotopic composition points to the presence of several isotopically distinct N-carrier phases in CI-type material. Here, we report preliminary N-Ne-Ar results obtained for individual particles from an aggregate Bennu sample using the Noblesse-HR (Nu Instruments) noble gas mass spectrometer at CRPG’s noble gas facility. In a companion abstract, we will present the noble gas (He, Ne, Ar, Kr, Xe) characteristics of other aggregate particles determined with a HELIX MC Plus. Whereas the abundance and isotopic composition of noble gases permit detection of various presolar phases and the so-called phase Q, as well as quantification of solar wind–derived and cosmogenic components, the abundance and isotopic composition of N are expected to provide further insights into the origin and evolution of N-bearing phases in carbonaceous asteroids.

E Füri↗

Degassing history of Mars from Martian atmosphere samples

A comparison of the abundances of Ar-40 and He-4 (radiogenic) in various terrestrial planetary atmospheres provides clues to the volcanic and tectonic histories of the planets while the amount of primordial noble gases in the planetary atmospheres provides clues to the quantities of volatile rich materials captured by each planet. The noble gas contents of Mars, Earth, and Venus clearly show that the absolute abundances of isotopes of gases are directly proportional to the amounts of degassed CO2 into the planetary atmosphere. Several basic geological units can be seen on the global geological map of Mars. The enormous size of volcanic and tectonic structures of Mars, despite its smaller size, provide invaluable clues to the degassing history of Mars. Therefore, the collection of samples of Martian atmosphere and soil volatiles is imperative to understand the origin and evolution of the atmosphere and its interaction with the Martian surface. Surface properties of Martian rocks, soils, breccias, and regolith and their chemistry are also generic to any discussion on the origin and evolution of the atmosphere of Mars. The differences in absolute abundances of gases in the planetary atmospheres are amenable to many alternative interpretations. These alternative interpretations can be tested by imposing additional constraints derived from the isotopic results of noble gases in the atmospheres of the planets.

Rao, A. S. P.↗