Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volatile organic compounds detected”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Volatile Organic Analyzer (VOA) in 2006: Repair, Revalidation, and Restart of Elektron Event

The Volatile Organic Analyzer (VOA) was launched to the International Space Station (ISS) in August 2001 and was the first instrument to provide near real-time measurement of volatile organic compounds in a spacecraft atmosphere. The VOA performed an analysis of the ISS air approximately twice a month for most of its operation through May 2003. This intermittent operation, caused by a software interface issue with the ISS communication bus, slowed the validation of the VOA. However, operational validation was completed in 2003 when analysis of air samples collected in grab sample containers (GSCs) compared favorably with simultaneous VOA runs (1). The VOA has two channels that provide redundant function, albeit at slightly reduced performance, when only one channel is operating (2). Most target compounds can be detected on both channels. In January 2003, the VOA identified a malfunction in the channel 2 preconcentrator and it shut down that channel. The anomaly profile suggested that a fuse might have failed, but the root cause could not be determined. In May 2003, channel 1 was shut down when the detector s elevated temperature could not longer be maintained. Since both VOA channels were now deactivated, VOA operations ended until an in-flight repair could be planned and executed. This paper describes the process to repair the VOA and to revalidate it for operations, and then an account is given of the VOA s contribution following a contingency event on ISS.

Limero, Thomas↗

Comprehensive analysis of airborne contaminants from recent Spacelab missions

The Shuttle experiences unique air contamination problems because of microgravity and the closed environment. Contaminant build-up in the closed atmosphere and the lack of a gravitational settling mechanism have produced some concern in previous missions about the amount of solid and volatile airborne contaminants in the Orbiter and Spacelab. Degradation of air quality in the Orbiter/Spacelab environment, through processes such as chemical contamination, high solid-particulate levels, and high microbial levels, may affect crew performance and health. A comprehensive assessment of the Shuttle air quality was undertaken during STS-40 and STS-42 missions, in which a variety of air sampling and monitoring techniques were employed to determine the contaminant load by characterizing and quantitating airborne contaminants. Data were collected on the airborne concentrations of volatile organic compounds, microorganisms, and particulate matter collected on Orbiter/Spacelab air filters. The results showed that STS-40/42 Orbiter/Spacelab air was toxicologically safe to breathe, except during STS-40 when the Orbiter Refrigerator/Freezer unit was releasing noxious gases in the middeck. On STS-40, the levels of airborne bacteria appeared to increase as the mission progressed; however, this trend was not observed for the STS-42 mission. Particulate matter in the Orbiter/Spacelab air filters was chemically analyzed in order to determine the source of particles. Only small amounts of rat hair and food bar (STS-40) and traces of soiless medium (STS-42) were detected in the Spacelab air filters, indicating that containment for Spacelab experiments was effective.

Matney, M. L.↗

Comets, Asteroids, and the Origin of the Biosphere

During the past few decades, the role of comets in the delivery of water, organics, and prebiotic chemicals to the Biosphere of Earth during the Hadean (4.5-3.8 Ga) period of heavy bombardment has become more widely accepted. However comets are still largely regarded as frigid, pristine bodies of protosolar nebula material that are entirely devoid of liquid water and consequently unsuitable for life in any form. Complex organic compounds have been observed comets and on the water rich asteroid 1998 KY26, which has color and radar reflectivity similar to the carbonaceous meteorites. Near infrared observations have indicated the presence of crystalline water ice and ammonia hydrate on the large Kuiper Belt object (50000) Quaoar with resurfacing that may indicate cryovolcanic outgassing and the Cassini spacecraft has detected water-ice geysers on Saturn s moon Enceladus. Spacecraft observations of the chemical compositions and characteristics of the nuclei of several comets (Halley, Borrelly, Wild 2, and Tempel 1) have now firmly established that comets contain a suite of complex organic chemicals; water is the predominant volatile; and that extremely high temperatures (approx.350-400 K) can be reached on the surface of the very black (albedo-0.03) nuclei when the comets are with 1.5 AU from the Sun. Impact craters and pinnacles observed on comet Wild 2 suggest a thick crust and episodic outbursts and jets observed on the nuclei of several comets are interpreted as indications that localized regimes of liquid water and water vapor can periodically exist beneath the crust of some comets. The Deep Impact observations indicate that the temperature on the nucleus of of comet Tempel 1 at 1.5 AU varied from 330K on the sunlit side to a minimum of 280+/-8 K. It is interesting that even the coldest region of the comet surface was slightly above the ice/liquid water phase transition temperature. These results suggest that pools and films of liquid water can exist in a wide range of temperatures in cavities and voids at different depths just beneath the crust of a comet. The possibility that liquid water may exist over a wide range of temperatures on comets significantly enhances the possibility that these bodies may harbor niches suitable for microbial communities and ecosystems. Such niches would by ideal for the growth of psychrophilic, mesophilic, and possibly even thermophilic chemolithotrophs and photoautotrophs such as the motile filamentous cyanobacteria (e.g., Calothrix, Oscillatoria, Phormidium, and Spirulina) that can grow in geothermal springs and geysers at temperatures ranging from 320K to 345K and in cold polar desert soils. This paper reviews the observational data in support of the hypothesis that liquid water can exist in permafrost-like active regions just beneath the surface of comets when near perihelion and provides additional arguments in support of the hypothesis that comets, carbonaceous meteorites, and asteroids may have played a significant role in the origin and evolution of the Biosphere and in the distribution of microbial life throughout the Solar System.

Hoover, Richard B.↗

Evaluation of the Interference of Tenax®TA Adsorbent With Dimethylformamide Dimethyl Acetal Reagent for Gas Chromatography-Dragonfly Mass Spectrometry and Future Gas Chromatography-Mass Spectrometry in Situ Analysis

Among future space missions, national aeronautics and space administration (NASA) selected two of them to analyze the diversity in organic content within Martian and Titan soil samples using a gas chromatograph – mass spectrometer (GC–MS) instrument. The Dragonfly space mission is planned to be launched in 2027 to Titan's surface and explore the Shangri-La surface region for years. One of the main goals of this mission is to understand the past and actual abundant prebiotic chemistry on Titan, which is not well characterized yet. The ExoMars space mission is planned to be launched in 2028 to Mars’ surface and explore the Oxia Planum and Mawrth Vallis region for years. The main objectives focus on the exploration of the subsurface soil samples, potentially richer in organics, that might be relevant for the search of past life traces on Mars where irradiation does not impact the matrices and organics. One recently used sample pre-treatment for gas chromatography – mass spectrometry analysis is planned on both space missions to detect refractory organic molecules of interest for astrobiology. This pre-treatment is called derivatization and uses a chemical reagent – called dimethylformamide dimethyl acetal (DMF-DMA) – to sublimate organic compounds keeping them safe from thermal degradation and conserving the chirality of the molecules extracted from Titan or Mars’ matrices. Indeed, the detection of building blocks of life or enantiomeric excess of some organics (e.g. amino acids) after DMF-DMA pre-treatment and GC–MS analyses would be both bioindicators. The main results highlighted by our work on DMF-DMA and Tenax®TA interaction and efficiency to detect organic compounds at ppb levels in a fast and single preparation are first that Tenax®TA did not show the onset of degradation until after 150 experiments – a 120 h at 300 °C experiment – which greatly exceeds the experimental lifetimes for the DraMS and GC-space in situ investigations. Tenax®TA polymer and DMF-DMA produce many by-products (about 70 and 46, respectively, depending on the activation temperature). Further, the interaction between the two leads to the production of 22 additional by-products from DMF-DMA degradation, but these listed by-products do not prevent the detection of trace-level organic molecules after their efficient derivatization and volatilization by DMF-DMA in the oven ahead the GC–MS trap and column.

DraMS-Dragonfly mission↗

UAS Payload Design for In-Situ Smoke Plume Sensing

To aid in the detection of harmful aerosols and trace gases emitted in wildfires and prescribed burns, we are designing a smoke-specific payload which can be flown on the Black Swift S2™ Uncrewed Aerial System (UAS) platform. The payload will be custom and mounted within the nosecone, equipped with a trace gas sensor suite and particle spectrometer for characterization of wildfire and prescribed burn emissions. This data will aid in the improvement of HYSPLIT3 modeling to make more informed decisions regarding prescribed burns, particularly for mountain valleys in the Pacific Northwest. The trace gas suite will be composed of 8 low-cost trace gas sensors (CH4, CO2, CO, HCN, NO2, NO, O3, and Volatile Organic Compounds (VOCs)). Portable Optical Particle Spectrometer (POPS) measures particle size range between 0.14 to 3 µm, which is crucial for assessing public health impact, air quality, and visibility.

Henry Miller↗

Missing OH Reactivity in the Global Marine Boundary Layer

The hydroxyl radical (OH) reacts with thousands of chemical species in the atmosphere, initiating their removal and the chemical reaction sequences that produce ozone, secondary aerosols, and gas-phase acids. OH reactivity, which is the inverse of OH lifetime,influences the OH abundance and the ability of OH to cleanse the atmosphere. The NASA Atmospheric Tomography (ATom) campaign used instruments on the NASA DC-8 aircraft to measure OH reactivity and more than 100 trace chemical species. ATom presented a unique opportunity to test the completeness of the OH reactivity calculated from the chemical species measurements by comparing it to the measured OH reactivity over two oceans across four seasons. Although, throughout much of the free troposphere, the calculated OH reactivity was below the limit-of-detection for the ATom instrument used to measure OH reactivity, the instrument was able to measure the OH reactivity in and just above the marine boundary layer. The mean measured value of OH reactivity in the marine boundary layer across all latitudes and all ATom deployments was 1.9 s-1, which is 0.5 s-1larger than the mean calculated OH reactivity. The missing OH reactivity, the difference between the measured and calculated OH reactivity, varied between 0 s-1to 3.5 s-1, with the highest values over the Northern Hemisphere Pacific Ocean. Correlations of missing OH reactivity with formaldehyde, dimethyl sulfide, butanal, and sea surface temperature suggest the presence of unmeasured or unknown volatile organic compounds or oxygenated volatile organic compounds associated with ocean emissions.

NASA Atmospheric Tomography (ATom)↗

Two Air Quality Regimes in Total Column NO2 over the Gulf of Mexico in May 2019: Shipboard and Satellite Views

The Satellite Coastal and Oceanic Atmospheric Pollution Experiment (SCOAPE) cruise in the Gulf of Mexico was conducted in May 2019 by NASA and the Bureau of Ocean Energy Management to determine the feasibility of using satellite data to measure air quality in a region of concentrated oil and natural gas (ONG) operations. SCOAPE addressed both technological and scientific issues related to measuring NO2 columns over the Outer Continental Shelf. Featured were nitrogen dioxide (NO 2 ) instruments (Pandora, Teledyne API analyzer) at Cocodrie, LA (29.26°, -90.66°), and on the Research Vessel Point Sur operating off the Louisiana coast with measurements of ozone, carbon monoxide and volatile organic compounds (VOC). The findings: (1) All NO 2 observations revealed two atmospheric regimes over the Gulf, the first influenced by tropical air in 10-14 May, the second influenced by flow from urban areas on 15-17 May; (2) Comparisons of OMI v4 and TROPOMI v1.3 TC (total column) NO 2 data with shipboard Pandora NO 2 column observations averaged 13% agreement with the largest difference during 15-17 May (~20%). At Cocodrie, the satellite-Pandora agreement was ~5%. (3) Three new-model Pandora instruments displayed a TC NO 2 precision of 0.01 Dobson Units (~5%); (4) Regions of smaller, older natural gas operations showed high methane readings from leakage; elevated VOC were also detected. Neither satellite nor spectrometer captured the magnitude of ambient NO 2 variability near ONG platforms. Given an absence of regular air quality monitoring over the Gulf of Mexico, SCOAPE data constitute a baseline against which future observations can be compared.

Nitrogen dioxide↗

In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

Glavin, D. P.↗

Perchlorate and Volatiles of the Brine of Lake Vida (Antarctica): Implication for the in Situ Analysis of Mars Sediments

The cold (-13.4 C), cryoencapsulated, anoxic, interstitial brine of the 27 m-thick ice of Lake Vida (Victoria Valley, Antarctica) contains 49 microgram L-1 of perchlorate and 11 microgram L-1 of chlorate. Lake Vida brine (LVBr) may provide an analog for potential oxychlorine-rich subsurface brine on Mars. LVBr volatiles were analyzed by solid-phase microextraction (SPME) gas chromatography-mass spectrometry (GC-MS) with two different SPME fibers. With the exception of volatile organic sulfur compounds, most other volatiles observed were artifacts produced in the GC injector when the thermal decomposition products of oxychlorines reacted with reduced carbon derived from LVBr and the SPME fiber phases. Analysis of MilliQ water with perchlorate (40 microgram L-1) showed low level of organic artifacts, reflecting carbon limitation. In order to observe sample-derived organic compounds, both in analog samples and on Mars, the molar abundance of reduced carbon in a sample must exceed those of O2 and Cl2 produced during decomposition of oxychlorines. This suggests that the abundance of compounds observed by the Sample Analysis at Mars (SAM) instruments in Sheepbed samples (CB-3, CB5, and CB6) may be controlled by an increase in the reduced-carbon/oxychlorine ratio of these samples. To increase chances of in situ detection of Martian organics during pyrolysis-GC-MS, we propose that the derivatization agents stored on SAM may be used as an external source of reduced carbon, increasing artificially the reduced-carbon to perchlorate ratio during pyrolysis, allowing the expression of more abundant and perhaps more diverse Martian organic matter.

Mars analog experiment↗

MOD: An Organic Detector for the Future Exploration of Mars

The Mars Organic Detector (MOD) is designed to assess whether organic compounds, possibly associated with life, are present in Martian rock and soil samples. MOD has a detection limit that is at least two orders of magnitude more sensitive than the Viking GCMS. MOD is focused on detecting amino acids, amines and PAH (polycyclic aromatic hydrocarbons). Amino acids play an essential role in biochemistry on Earth and PAH are widespread throughout the universe and can provide an indication of the delivery of meteoritic organic material to Mars. The advantage of MOD is the absence of wet chemistry and its simple and robust design. The sample will be extracted from the mineral matrix (0.1 - 1 g of rock-powder) using sublimation and analyzed with a fluorescence detector. The isolation method is based on the fact that amino acids and PAH are volatile at temperatures greater than 150C. The fluorescence detection scheme is based on UV excitation with LED's, optical filters, PrN diode photon detector and a sample calibration reservoir. Fluorescamine is used as a fluorescing reagent for amino acids and amines, while PAH are naturally fluorescent. There is no sample preparation required and the turnaround time for a single analysis is on the order of minutes.

Kminek, G.↗

Organic-rich fluids in Pluto’s interior—A source of cryovolcanic activity

The highly variegated surface of Pluto revealed by the New Horizons spacecraft is composed of both volatile ices (N2, CH4, CO) and H2O ice, all of which are intrinsically colorless. The colors on Pluto reveal a non-ice component generally acknowledged to be a refractory complex organic material (tholins) produced by photolysis in the planet’s atmosphere [1], and by photolysis and radiolysis of the surface ices [2-4]. These processes have produced a range of colors from pale yellow to red to brown, and result in a variation of a factor of 10in albedo across the surface. Tholins are disordered polymer-like materials made of repeating chains of linked subunits and complex combinations of functional groups containing carbon. Nitrogen, oxygen, and other elements can be substituted in both the aliphatic and aromatic subunits. The detection of the spectral absorption of an ammoniated compound associated with surface exposures of red-colored H2O ice (herein, RAW) in the LEISA spectral mapping data from New Horizons suggests that a third source of a colored material is ejected from Pluto’s interior as a water-rich fluid(cryomagma) that rapidly freezes at the low temperature (~40K) of the surface [5,6]. The ammoniated compound is thought to be an ammonia hydrate or an ammoniated salt; the spectral data cover a limited wavelength range, resulting in ambiguity in the identification of the form of the ammonia. The distribution of RAW in the vicinity of tectonically stressed and deformed geological structures, particularly graben (fossae), is seen as the result of both fluid effusion and fountaining ejection of cryoclastic materials in Pluto’s Virgil Fossae region [5,6]. RAW is seen elsewhere on Pluto, both in association with graben complexes and on broad expanses of old surface, but primarily in zones of tectonic stress. The nature of the putative subsurface fluid is unknown, but it must have existed at relatively shallow depths such that the graben faulting could reach it. Geochemical modeling of fluids in the interiors of small planetary bodies in the outer Solar System[7] shows that ammonia-bearing H2O in contact with rock and metal components produce a rich chemical soup, including gases that can, in principle, help propel the fluid from shallow reservoirs through crustal fractures to reach the surface. An organic component of the fluid cryomagma is predicted to originate from thermal processing of the components [ref] and may be an example of one-pot synthesis of such complexes as amino acid precursors [ref].

Dale P Cruikshank↗

Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

Carle, G. C.↗

Rotational Spectroscopy is SubLIME: Site-Specific Identification of Compounds Formed on UV-photolyzed Cosmcs Ice

A variety of organic compounds has been detected in comets, meteorites, and the cold gas enveloping infant stars. These compounds display a range of complexity and include so-called complex organic molecules that may have astrobiological implications. Laboratory studies of photolyzed and nonirradiated interstellar, planetary, and cometary ices have demonstrated many astrochemical formation routes and require sensitive analytical techniques to identify the composition of ice and gas products formed. The unique identification of organics can be challenging and often requires structure-specific techniques to identify structural isomers, conformers, and isotopologues. We present the approaches used in SubLIME, the Sublimation of Laboratory Ices Millimeter/submillimeter Experiment, which uses the structure-specificity of rotational spectroscopy to identify the composition and abundances of sublimated products of UV-photolyzed ice samples. Ices are formed and photolyzed at low temperature (~10 K) and slowly heated to 300 K to sublimate the volatile products. The gas mixture is then investigated with millimeter/submillimeter spectroscopy, and the resulting spectra compared to observational spectra collected with submillimeter/far-IR telescopes. We present the experimental set-up and results of UV-photolyzed interstellar ice analogues containing water (H O) and carbon monoxide (CO). Formation routes for identified molecules are proposed for follow-up experimental and theoretical investigations.

Olivia H. Wilkins↗

General Services Administration Reclamation Yard, SWMU 010, 2021 Groundwater Monitoring Report

This report presents a summary of the groundwater monitoring activities that occurred in November and December 2021 at General Services Administration Reclamation Yard, Solid Waste Management Unit 010, located at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. For the purposes of this report, two separate plumes, known as the Polychlorinated Biphenyl (PCB)/Volatile Organic Aromatic (VOA) Plume and the Chlorinated Volatile Organic Compound (VOC) Plume, were identified for this site. The contaminants of concern (COCs) for the PCB/VOA Plume consists of PCBs, 1,2,4-trichlorobenzene, and breakdown products of 1,2,4-trichlorobenzene. The COCs for the Chlorinated VOC Plume are tetrachloroethene, trichloroethene, cis-1,2-dichloroethene, and vinyl chloride. The activities presented in this report include two field events: (1) November 2021 – PCB/VOA Plume groundwater sampling via Direct Push Technology – 70 groundwater samples were collected from 10 locations at varying intervals; and (2) December 2021 – Site-wide semi-annual water level measurements of 54 monitoring wells, redevelopment of 5 monitoring wells, and sampling of 35 monitoring wells. Results for the PCB/VOA plume demonstrated COCs have not rebounded since the 2018 source removal, with groundwater cleanup target levels (GCTLs) exceeded in the 10-30 ft. below ground surface interval only. In the Chlorinated VOC plume area, there were no detections of COCs above a GCTL for at least the second consecutive sampling event for the sampled wells. Cleanup objectives have been met, and it is recommended that VOC monitoring be discontinued. Underground injection control parameters will continue to be monitored in three wells until those analytes return to background concentrations.

GSA Reclamation Yard↗

Wilson Corners SWMU 001 2014 Annual Long Term Monitoring Report Kennedy Space Center, Florida

This document presents the findings of the 2014 Long Term Monitoring (LTM) that was completed at the Wilson Corners site, located at the National Aeronautics and Space Administration (NASA) John F. Kennedy Space Center (KSC), Florida. The goals of the 2014 annual LTM event were to evaluate the groundwater flow direction and gradient and to monitor the vertical and downgradient horizontal extent of the volatile organic compounds (VOCs) in groundwater at the site. The LTM activities consisted of an annual groundwater sampling event in December 2014, which included the collection of water levels from the LTM wells. During the annual groundwater sampling event, depth to groundwater was measured and VOC samples were collected using passive diffusion bags (PDBs) from 30 monitoring wells. In addition to the LTM sampling, additional assessment sampling was performed at the site using low-flow techniques based on previous LTM results and assessment activities. Assessment of monitoring well MW0052DD was performed by collecting VOC samples using low-flow techniques before and after purging 100 gallons from the well. Monitoring well MW0064 was sampled to supplement shallow VOC data north of Hot Spot 2 and east of Hot Spot 4. Monitoring well MW0089 was sampled due to its proximity to MW0090. MW0090 is screened in a deeper interval and had an unexpected detection of trichloroethene (TCE) during the 2013 LTM, which was corroborated during the March 2014 verification sampling. Monitoring well MW0130 was sampled to provide additional VOC data beneath the semi-confining clay layer in the Hot Spot 2 area.

Monitoring↗

Evaluation of a Gas Chromatograph-Differential Mobility Spectrometer for Potential Water Monitoring on the International Space Station

Environmental monitoring for manned spaceflight has long depended on archival sampling, which was sufficient for short missions. However, the longer mission durations aboard the International Space Station (ISS) have shown that enhanced, real-time monitoring capabilities are necessary in order to protect both the crewmembers and the spacecraft systems. Over the past several years, a number of real-time environmental monitors have been deployed on the ISS. Currently, volatile organic compounds (VOCs) in the station air are monitored by the Air Quality Monitor (AQM), a small, lightweight gas chromatograph-differential mobility spectrometer. For water monitoring, real-time monitors are used for total organic carbon (TOC) and biocide analysis. No information on the actual makeup of the TOC is provided presently, however. An improvement to the current state of environmental monitoring could be realized by modifying a single instrument to analyze both air and water. As the AQM currently provides quantitative, compound-specific information for VOCs in air samples, this instrument provides a logical starting point to evaluate the feasibility of this approach. The major hurdle for this effort lies in the liberation of the target analytes from the water matrix. In this presentation, we will discuss our recent studies, in which an electro-thermal vaporization unit has been interfaced with the AQM to analyze target VOCs at the concentrations at which they are routinely detected in archival water samples from the ISS. We will compare the results of these studies with those obtained from the instrumentation routinely used to analyze archival water samples.

Wallace, William T.↗

Wilson Corners SWMU 001 2019-2020 Annual Long-Term Monitoring Report Kennedy Space Center, Florida

This report presents a summary of the long-term monitoring (LTM) activities that occurred in 2019 and 2020 at Wilson Corners, Solid Waste Management Unit 001, at the John F. Kennedy Space Center (KSC), Florida. The site is monitored under KSC’s Resource Conservation and Recovery Act Corrective Action Program. Adaptive site management is being utilized through ongoing assessment, design, and interim measures. This approach also meets the requirements of Chapter 62-780, Florida Administrative Code. The goal of LTM at this site is threefold: to determine groundwater flow characteristics, monitor the downgradient concentration trends, and monitor select locations internal to the groundwater plume. Every 5 years, upgradient and side-gradient monitoring wells are sampled to verify delineation. The last time this was performed was in 2015. Sampling of these wells in 2020 was replaced with the direct push technology investigations in October 2020 and April 2021. The activities presented in this report include three field events: (1) December 2019 -groundwater gauging of 38 monitoring wells and sampling of 36 monitoring wells; (2) May 2020 - groundwater sampling of 7 monitoring wells; and (3) December 2020 - groundwater gauging of 49 monitoring wells and sampling of 43 monitoring wells. During the December 2019 and May 2020 events, monitoring wells were sampled using passive diffusion bags and were analyzed for a “full list” of volatile organic compounds (VOCs), including Freon 113. During the December 2020 event, the low flow sampling method was used, and samples were analyzed for a “select list” of VOCs, including Freon 113. The following conclusions can be made based on the 2019 and 2020 LTM results: •In December 2019 and December 2020, groundwater flow for the site was generally to the west with the individual zones only varying by occasional northerly and southerly components. This is generally consistent with historical observations at the site. •The GCTL plume continues to extend both horizontally and vertically beyond our current monitoring well network. •The vertical extent of VOCs was historically generally delineated by monitoring wells screened greater than 48 feet bls. The results from the two vertical extent monitoring wells WILC-MW0078 and WILC-MW0130 that were sampled during the 2019 and 2020 LTM indicate that groundwater VOC concentrations in both wells were greater than the GCTL. •Freon 113 was not detected above GCTLs during the 2019 and 2020 LTM events. Based on groundwater sampling activities performed during this reporting period, including recent DPT groundwater sampling conducted for the implementation of an air sparge system, the following recommendations are provided: •Install 10 new monitoring wells, which will be sampled along with 49 existing monitoring wells, to assist with delineation of the low concentration plume. The wells are listed inTable 4-1, and the proposed locations are presented on Figures4 -1 through 4-5. (Figures 4-1, 4-2, 4-3, and 4-5 also show updated plumes and proposed performance monitoring well locations. This information will be discussed and presented under a separate cover.) •Modify the annual LTM sampling plan as presented inTable 4-1. •Sampling for future events at the site will be conducted using low flow pumping methods. The next annual LTM sampling event is currently planned for December 2021. Please note the 10 new monitoring wells will not be installed before this event but will be installed as part of the upcoming IM construction and will be sampled during baseline sampling, along with the 49 existing monitoring wells. Following this sampling event, it is recommended that the Annual LTM be combined with the performance monitoring under the IM implementation, and LTM be temporarily discontinued. Objectives of the 2021 LTM are to: (i) evaluate groundwater gradient and flow direction by collecting depth to water measurements from LTM wells; (ii) continue monitoring the peripheral VOC trends in the northern, southern, and western portions of the site by monitoring existing wells and installing and monitoring new wells as recommended; and (iii) monitor select internal plume wells.

Jennifer Lynn Joyal↗

Characterization of Errors in Satellite-Based HCHO/NO 2 Tropospheric Column Ratios With Respect to Chemistry, Column-to-PBL Translation, Spatial Representation, and Retrieval Uncertainties

The availability of formaldehyde (HCHO) (a proxy for volatile organic compound reactivity) and nitrogen dioxide (NO 2 ) (a proxy for nitrogen oxides) tropospheric columns from ultraviolet–visible (UV–Vis) satellites has motivated many to use their ratios to gain some insights into the near-surface ozone sensitivity. Strong emphasis has been placed on the challenges that come with transforming what is being observed in the tropospheric column to what is actually in the planetary boundary layer (PBL) and near the surface; however, little attention has been paid to other sources of error such as chemistry, spatial representation, and retrieval uncertainties. Here we leverage a wide spectrum of tools and data to quantify those errors carefully. Concerning the chemistry error, a well-characterized box model constrained by more than 500 h of aircraft data from NASA's air quality campaigns is used to simulate the ratio of the chemical loss of HO 2 + RO 2 (LRO x ) to the chemical loss of NO x (LNO x ). Subsequently, we challenge the predictive power of HCHO/NO 2 ratios (FNRs), which are commonly applied in current research, in detecting the underlying ozone regimes by comparing them to LRO x /LNO x . FNRs show a strongly linear (R 2 =0.94) relationship with LRO x /LNO x , but only on the logarithmic scale. Following the baseline (i.e., ln(LRO x /LNO x ) = −1.0 ± 0.2) with the model and mechanism (CB06, r2) used for segregating NO x -sensitive from VOC-sensitive regimes, we observe a broad range of FNR thresholds ranging from 1 to 4. The transitioning ratios strictly follow a Gaussian distribution with a mean and standard deviation of 1.8 and 0.4, respectively. This implies that the FNR has an inherent 20 % standard error (1σ) resulting from not accurately describing the RO x –HO x cycle. We calculate high ozone production rates (PO 3 ) dominated by large HCHO × NO 2 concentration levels, a new proxy for the abundance of ozone precursors. The relationship between PO 3 and HCHO × NO 2 becomes more pronounced when moving towards NO x -sensitive regions due to nonlinear chemistry; our results indicate that there is fruitful information in the HCHO × NO 2 metric that has not been utilized in ozone studies. The vast amount of vertical information on HCHO and NO 2 concentrations from the air quality campaigns enables us to parameterize the vertical shapes of FNRs using a second-order rational function permitting an analytical solution for an altitude adjustment factor to partition the tropospheric columns into the PBL region. We propose a mathematical solution to the spatial representation error based on modeling isotropic semivariograms. Based on summertime-averaged data, the Ozone Monitoring Instrument (OMI) loses 12 % of its spatial information at its native resolution with respect to a high-resolution sensor like the TROPOspheric Monitoring Instrument (TROPOMI) (> 5.5 × 3.5 km 2 ). A pixel with a grid size of 216 km 2 fails at capturing ∼ 65 % of the spatial information in FNRs at a 50 km length scale comparable to the size of a large urban center (e.g., Los Angeles). We ultimately leverage a large suite of in situ and ground-based remote sensing measurements to draw the error distributions of daily TROPOMI and OMI tropospheric NO 2 and HCHO columns. At a 68 % confidence interval (1σ), errors pertaining to daily TROPOMI observations, either HCHO or tropospheric NO 2 columns, should be above 1.2–1.5 × 10 16 molec. cm −2 to attain a 20 %–30 % standard error in the ratio. This level of error is almost non-achievable with the OMI given its large error in HCHO. The satellite column retrieval error is the largest contributor to the total error (40 %–90 %) in the FNRs. Due to a stronger signal in cities, the total relative error (< 50 %) tends to be mild, whereas areas with low vegetation and anthropogenic sources (e.g., the Rocky Mountains) are markedly uncertain (> 100 %). Our study suggests that continuing development in the retrieval algorithm and sensor design and calibration is essential to be able to advance the application of FNRs beyond a qualitative metric.

Amir H. Souri↗