Search NASA⌕ Search

SEARCH · Search NASA

Results for “Volume Constraint”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Role of belly board device in the age of intensity modulated radiotherapy for pelvic irradiation

Small bowel dose often represents a limiting factor for radiation treatment of pelvic malignancies. To reduce small bowel toxicity, a belly board device (BBD) with a prone position is often recommended. Intensity modulated radiotherapy (IMRT) could reduce dose to small bowel based on the desired dose-volume constraints. We investigated the efficacy of BBD in conjunction with IMRT. A total of 11 consecutive patients with the diagnosis of rectal cancer, who were candidates for definitive therapy, were selected. Patients were immobilized with BBD in prone position for simulation and treatment. Supine position computed tomography (CT) data were either acquired at the same time or during a diagnostic scan, and if existed was used. Target volumes (TV) as well as organs at risk (OAR) were delineated in both studies. Three-dimensional conformal treatment (3DCRT) and IMRT plans were made for both scans. Thus for each patient, 4 plans were generated. Statistical analysis was conducted for maximum, minimum, and mean dose to each structure. When comparing the normalized mean Gross TV dose for the different plans, there was no statistical difference found between the planning types. There was a significant difference in small bowel sparing when using prone position on BBD comparing 3DCRT and IMRT plans, favoring IMRT with a 29.6% reduction in dose (p = 0.007). There was also a statistically significant difference in small bowel sparing when comparing supine position IMRT to prone-BBD IMRT favoring prone-BBD IMRT with a reduction of 30.3% (p = 0.002). For rectal cancer when small bowel could be a limiting factor, prone position using BBD along with IMRT provides the best sparing. We conclude that whenever a dose escalation in rectal cancer is desired where small bowel could be limiting factor, IMRT in conjunction with BBD should be selected.

61 RADIATION PROTECTION AND DOSIMETRY↗

Bile Acid Malabsorption After Pelvic and Prostate Intensity Modulated Radiation Therapy: An Uncommon but Treatable Condition

Purpose: Intensity modulated radiation therapy (IMRT) is a significant therapeutic advance in prostate cancer, allowing increased tumor dose delivery and increased sparing of normal tissues. IMRT planning uses strict dose constraints to nearby organs to limit toxicity. Bile acid malabsorption (BAM) is a treatable disorder of the terminal ileum (TI) that presents with symptoms similar to radiation therapy toxicity. It has not been described in patients receiving RT for prostate cancer in the contemporary era. We describe new-onset BAM in men after IMRT for prostate cancer. Methods and Materials: Diagnosis of new-onset BAM was established after typical symptoms developed, selenium-75 homocholic acid taurine (SeHCAT) scanning showed 7-day retention of <15%, and patients' symptoms unequivocally responded to a bile acid sequestrant. The TI was identified on the original radiation therapy plan, and the radiation dose delivered was calculated and compared with accepted dose-volume constraints. Results: Five of 423 men treated in a prospective series of high-dose prostate and pelvic IMRT were identified with new onset BAM (median age, 65 years old). All reported having normal bowel habits before RT. The volume of TI ranged from 26-141 cc. The radiation dose received by the TI varied between 11.4 Gy and 62.1 Gy (uncorrected). Three of 5 patients had TI treated in excess of 45 Gy (equivalent dose calculated in 2-Gy fractions, using an {alpha}/{beta} ratio of 3) with volumes ranging from 1.6 cc-49.0 cc. One patient had mild BAM (SeHCAT retention, 10%-15%), 2 had moderate BAM (SeHCAT retention, 5%-10%), and 2 had severe BAM (SeHCAT retention, <5%). The 3 patients whose TI received {>=}45 Gy developed moderate to severe BAM, whereas those whose TI received <45 Gy had only mild to moderate BAM. Conclusions: Radiation delivered to the TI during IMRT may cause BAM. Identification of the TI from unenhanced RT planning computed tomography scans is difficult and may impede accurate dosimetric evaluation. Thorough toxicity assessment and close liaison between oncologist and gastroenterologist allow timely diagnosis and treatment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-BRD-02: Incorporating Uncertainty Analysis in Plan Comparison of VMAT, Double Scattering Proton Plan and IMPT for Lung Irradiation

Purpose: We investigate the effect of residual setup and motion errors in lung irradiation for VMAT, double scattering (DS) proton beams and spot scanning (IMPT) in a case study. Methods: The CT image and contour sets of a lung patient treated with 6 MV VMAT is re-planned with DS as well as IMPT subject to the same constraints; V20(lung), V10(lung) and V5(lung)< 15%, 20% and 25% respectively, V20(heart)<25% and V100%(PTV)≥95%. In addition, uncertainty analysis in the form of isocenter shifts (±1–3mm) was incorporated in the DVH calculations to assess the plan robustness. Results: Only the IMPT plan satisfies all the specified constraints. The 3D-conformal DS proton plan is able to achieve better sparing of the lung and heart dose compared to VMAT. For the lung, V20, V10 and V5 are 13%, 19% and 25% respectively for IMPT, 18%, 23% and 30% respectively for DS, and 20%, 30% and 42% respectively for VMAT. For heart: 0.6% for IMPT, 2.4% for DS and 30% for VMAT. When incorporating isocenter shifts in DVH calculations, the maximum changes in V20, V10 and V5 for lung are 14%, 21% and 28% respectively for IMPT. The corresponding max changes are19%, 24% and 32% respectively for DS, and 22%, 32% and 44% respectively for VMAT. The largest change occurs in the PTV coverage. For IMPT, V100%(PTV) varies between 88–96%, while V100%(PTV) for VMAT suffers a larger change compared to DS (Δ=5.5% vs 3.3%). Conclusion: While only IMPT satisfies the stringent dose-volume constraints for the lung irradiation, it is not as robust as the 3D conformal DS plan. DS also has better sparing in lung and heart compared to VMAT and similar PTV coverage. By including isocenter shifts in dose-volume calculations in treatment planning of lung, DS appears to be more robust than VMAT.

60 APPLIED LIFE SCIENCES↗

Evolvable Mars Campaign Long Duration Habitation Strategies: Architectural Approaches to Enable Human Exploration Missions

The Evolvable Mars Campaign (EMC) is the current NASA Mars mission planning effort which seeks to establish sustainable, realistic strategies to enable crewed Mars missions in the mid-2030s timeframe. The primary outcome of the Evolvable Mars Campaign is not to produce "The Plan" for sending humans to Mars, but instead its intent is to inform the Human Exploration and Operations Mission Directorate near-term key decisions and investment priorities to prepare for those types of missions. The FY'15 EMC effort focused upon analysis of integrated mission architectures to identify technically appealing transportation strategies, logistics build-up strategies, and vehicle designs for reaching and exploring Mars moons and Mars surface. As part of the development of this campaign, long duration habitats are required which are capable of supporting crew with limited resupply and crew abort during the Mars transit, Mars moons, and Mars surface segments of EMC missions. In particular, the EMC design team sought to design a single, affordable habitation system whose manufactured units could be outfitted uniquely for each of these missions and reused for multiple crewed missions. This habitat system must provide all of the functionality to safely support 4 crew for long durations while meeting mass and volume constraints for each of the mission segments set by the chosen transportation architecture and propulsion technologies. This paper describes several proposed long-duration habitation strategies to enable the Evolvable Mars Campaign through improvements in mass, cost, and reusability, and presents results of analysis to compare the options and identify promising solutions. The concepts investigated include several monolithic concepts: monolithic clean sheet designs, and concepts which leverage the co-manifested payload capability of NASA's Space Launch System (SLS) to deliver habitable elements within the Universal Payload Adaptor between the SLS upper stage and the Orion/Service module on the top of the vehicle. Multiple modular habitat options for Mars surface and in-space missions are also considered with various functionality and volume splits between modules to find the best balance of reducing the single largest mass which must be delivered to a destination and reducing the number of separate elements which must be launched. Analysis results presented for each of these concepts in this paper include mass/volume/power sizing using parametric sizing tools, identification of unique operational constraints, and limited comments on the additional impacts of reusability/dormancy on system design. Finally, recommendations will be made for promising solutions which will be carried forward for consideration in the Evolvable Mars Campaign work.

Simon, Matthew A.↗

SU-E-T-368: Evaluating Dosimetric Outcome of Modulated Photon Radiotherapy (XMRT) Optimization for Head and Neck Patients

Purpose: The dosimetric outcome of optimized treatment plans obtained by modulating the photon beamlet energy and fluence on a small cohort of four Head and Neck (H and N) patients was investigated. This novel optimization technique is denoted XMRT for modulated photon radiotherapy. The dosimetric plans from XMRT for H and N treatment were compared to conventional, 6 MV intensity modulated radiotherapy (IMRT) optimization plans. Methods: An arrangement of two non-coplanar and five coplanar beams was used for all four H and N patients. Both XMRT and IMRT were subject to the same optimization algorithm, with XMRT optimization allowing both 6 and 18 MV beamlets while IMRT was restricted to 6 MV only. The optimization algorithm was based on a linear programming approach with partial-volume constraints implemented via the conditional value-at-risk method. H and N constraints were based off of those mentioned in the Radiation Therapy Oncology Group 1016 protocol. XMRT and IMRT solutions were assessed using metrics suggested by International Commission on Radiation Units and Measurements report 83. The Gurobi solver was used in conjunction with the CVX package to solve each optimization problem. Dose calculations and analysis were done in CERR using Monte Carlo dose calculation with VMC{sub ++}. Results: Both XMRT and IMRT solutions met all clinical criteria. Trade-offs were observed between improved dose uniformity to the primary target volume (PTV1) and increased dose to some of the surrounding healthy organs for XMRT compared to IMRT. On average, IMRT improved dose to the contralateral parotid gland and spinal cord while XMRT improved dose to the brainstem and mandible. Conclusion: Bi-energy XMRT optimization for H and N patients provides benefits in terms of improved dose uniformity to the primary target and reduced dose to some healthy structures, at the expense of increased dose to other healthy structures when compared with IMRT.

60 APPLIED LIFE SCIENCES↗

Impact of Four-Dimensional Computed Tomography Pulmonary Ventilation Imaging-Based Functional Avoidance for Lung Cancer Radiotherapy

Purpose: To quantify the dosimetric impact of four-dimensional computed tomography (4D-CT) pulmonary ventilation imaging-based functional treatment planning that avoids high-functional lung regions. Methods and Materials: 4D-CT ventilation images were created from 15 non-small-cell lung cancer patients using deformable image registration and quantitative analysis of the resultant displacement vector field. For each patient, anatomic and functional plans were created for intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT). Consistent beam angles and dose-volume constraints were used for all cases. The plans with Radiation Therapy Oncology Group (RTOG) 0617-defined major deviations were modified until clinically acceptable. Functional planning spared the high-functional lung, and anatomic planning treated the lungs as uniformly functional. We quantified the impact of functional planning compared with anatomic planning using the two- or one-tailed t test. Results: Functional planning led to significant reductions in the high-functional lung dose, without significantly increasing other critical organ doses, but at the expense of significantly degraded the planning target volume (PTV) conformity and homogeneity. The average reduction in the high-functional lung mean dose was 1.8 Gy for IMRT (p < .001) and 2.0 Gy for VMAT (p < .001). Significantly larger changes occurred in the metrics for patients with a larger amount of high-functional lung adjacent to the PTV. Conclusion: The results of the present study have demonstrated the impact of 4D-CT ventilation imaging-based functional planning for IMRT and VMAT for the first time. Our findings indicate the potential of functional planning in lung functional avoidance for both IMRT and VMAT, particularly for patients who have high-functional lung adjacent to the PTV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Design and Application of the Exploration Maintainability Analysis Tool

Conducting human exploration missions beyond Low Earth Orbit (LEO) will present unique challenges in the areas of supportability and maintainability. The durations of proposed missions can be relatively long and re-supply of logistics, including maintenance and repair items, will be limited or non-existent. In addition, mass and volume constraints in the transportation system will limit the total amount of logistics that can be flown along with the crew. These constraints will require that new strategies be developed with regards to how spacecraft systems are designed and maintained. NASA is currently developing Design Reference Missions (DRMs) as an initial step in defining future human missions. These DRMs establish destinations and concepts of operation for future missions, and begin to define technology and capability requirements. Because of the unique supportability challenges, historical supportability data and models are not directly applicable for establishing requirements for beyond LEO missions. However, supportability requirements could have a major impact on the development of the DRMs. The mass, volume, and crew resources required to support the mission could all be first order drivers in the design of missions, elements, and operations. Therefore, there is a need for enhanced analysis capabilities to more accurately establish mass, volume, and time requirements for supporting beyond LEO missions. Additionally, as new technologies and operations are proposed to reduce these requirements, it is necessary to have accurate tools to evaluate the efficacy of those approaches. In order to improve the analysis of supportability requirements for beyond LEO missions, the Space Missions Analysis Branch at the NASA Langley Research Center is developing the Exploration Maintainability Analysis Tool (EMAT). This tool is a probabilistic simulator that evaluates the need for repair and maintenance activities during space missions and the logistics and crew requirements to support those activities. Using a Monte Carlo approach, the tool simulates potential failures in defined systems, based on established component reliabilities, and then evaluates the capability of the crew to repair those failures given a defined store of spares and maintenance items. Statistical analysis of Monte Carlo runs provides probabilistic estimates of overall mission safety and reliability. This paper will describe the operation of the EMAT, including historical data sources used to populate the model, simulation processes, and outputs. Analysis results are provided for a candidate exploration system, including baseline estimates of required sparing mass and volume. Sensitivity analysis regarding the effectiveness of proposed strategies to reduce mass and volume requirements and improve mission reliability is included in these results.

Stromgren, Chel↗

Thyroid V30 Predicts Radiation-Induced Hypothyroidism in Patients Treated With Sequential Chemo-Radiotherapy for Hodgkin's Lymphoma

Purpose: Hypothyroidism (HT) is a frequent late side effect of Hodgkin's lymphoma (HL) therapy. The purpose of this study is to determine dose-volume constraints that correlate with functional impairment of the thyroid gland in HL patients treated with three-dimensional radiotherapy. Methods and Materials: A total of 61 consecutive patients undergoing antiblastic chemotherapy and involved field radiation treatment (median dose, 32 Gy; range, 30-36 Gy) for HL were retrospectively considered. Their median age was 28 years (range, 14-70 years). Blood levels of thyroid-stimulating hormone (TSH), free triiodo-thyronine (FT3), free thyroxine (FT4), and thyroglobulin antibody (ATG) were recorded basally and at different times after the end of therapy. For the thyroid gland, normal tissue complication probability (NTCP), dosimetric parameters, and the percentage of thyroid volume exceeding 10, 20, and 30 Gy (V10, V20, and V30) were calculated in all patients. To evaluate clinical and dosimetric factors possibly associated with HT, univariate and multivariate logistic regression analyses were performed. Results: Eight of 61 (13.1%) patients had HT before treatment and were excluded from further evaluation. At a median follow-up of 32 months (range, 6-99 months), 41.5% (22/53) of patients developed HT after treatment. Univariate analyses showed that all dosimetric factors were associated with HT (p < 0.05). On multivariate analysis, the thyroid V30 value was the single independent predictor associated with HT (p = 0.001). This parameter divided the patients into low- vs. high-risk groups: if V30 was {<=} 62.5%, the risk of developing HT was 11.5%, and if V30 was >62.5%, the risk was 70.8% (p < 0.0001). A Cox regression curve stratified by two levels of V30 value was created (odds ratio, 12.6). Conclusions: The thyroid V30 predicts the risk of developing HT after sequential chemo-radiotherapy and defines a useful constraint to consider for more accurate HL treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-J-239: IMRT Planning of Prostate Cancer for a MRI-Linac Based On MRI Only

Purpose: : To investigate dosimetric differences between MRI- and CT-based IMRT planning for prostate cancer, the impact of a magnetic field in a MRI-Linac, and to explore the feasibility of IMRT planning based on MRI alone. Methods: IMRT plans were generated based on CT and MRI images acquired on two representative prostate-cancer patients using clinical dose volume constraints. A research planning system (Monaco, Elekta), which employs a Monte Carlo dose engine and includes a perpendicular magnetic field of 1.5T from an MRI-Linac, was used. Bulk electron density assignments based on organ-specific values from ICRU 46 were used to convert MRI (T2) to pseudo CT. With the same beam configuration as in the original CT plan, 5 additional plans were generated based on CT or MRI, with or without optimization (i.e., just recalculation) and with or without the magnetic field. The plan quality in terms of commonly used dose volume (DV) parameters for all plans was compared. The statistical uncertainty on dose was < 1%. Results: For plans with the same contour set but without re-optimization, the DV parameters were different from those for the original CT plan, mostly less than 5% with a few exceptions. These differences were reduced to mostly less than 3% when the plans were re-optimized. For plans with contours from MRI, the differences in the DV parameters varied depending on the difference in the contours as compared to CT. For the optimized plans with contours from MR, the differences for PTV were less than 3%. Conclusion: The prostate IMRT plans based on MRI-only for a MR-Linac were practically similar as compared to the CT plan under the same beam and optimization configuration if the difference on the structure delineation is excluded, indicating the feasibility of using MRI-only for prostate IMRT.

60 APPLIED LIFE SCIENCES↗

MO-C-BRD-01: SBRT I: Overview of Simulation, Planning, and Delivery

SBRT is having a dramatic impact on radiation therapy of early-stage, locally advanced cancers. Treatment planning of SBRT is characterized by precise target volume delineation, highly conformal dose distribution, sharp dose gradient outside the target volume, and meticulous tumor motion management. Stringent dose volume constraints of SBRT require the treatment planning to be highly personalized. Not only the complete patient's medical information (anatomy, tumor size/shape/location/motion, breathing pattern, health status) should be taken into consideration during planning, but also a wide range of factors including imaging techniques (imaging modality, breathing control, immobilization, patient position, etc.), treatment planning techniques (3D-conformal, dynamic conformal arcs, IMRT, VMAT, etc.), image guidance techniques (CBCT, orthogonal X-Ray, fiducial marker tracking, fluoroscopy, etc.), and delivery techniques (FFF, gating, tracking, etc.). In addition, potential pitfalls may exist in SBRT techniques and processes, such as target volume error in 4DCT and image registration error in image guidance. How to manage these affecting factors to achieve optimal, personalized SBRT treatment plans remains a great challenge. In this proposal, we will review technologies, share experiences, and discuss strategies concerning SBRT simulation, planning, and delivery. Learning Objectives: Understand requirements and challenges of SBRT treatment planning Discuss information-driven strategies of developing optimal SBRT plans Discuss practical considerations and potential pitfalls of SBRT treatment planning.

60 APPLIED LIFE SCIENCES↗

Toxicity of Three-Dimensional Conformal Radiotherapy for Accelerated Partial Breast Irradiation

Purpose: To assess the incidence and severity of late normal tissue toxicity using three-dimensional conformal radiotherapy to deliver accelerated partial breast irradiation. Methods and Materials: A total of 60 patients were treated with three-dimensional conformal radiotherapy for accelerated partial breast irradiation. Treatment planning and delivery were in strict accordance with the technique and specified dose-volume constraints of the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol. Late toxicity was evaluated according to the Radiation Therapy Oncology Group grading schema. The cosmetic outcome was scored using the Harvard criteria. Univariate logistic regression analysis was performed to evaluate the correlation of dosimetric variables with outcome. Results: At a median follow-up of 15 months, moderate-to-severe late toxicity developed in 10% of patients. The most pronounced late toxicity was subcutaneous fibrosis: 25% Grade 2-4 and 8.3% Grade 3-4. The modified planning tumor volume/whole breast volume ratio, ratio of the volume of breast tissue receiving 5%, 20%, 50%, and 80% of the prescription dose to the whole breast volume, and maximal dose within the breast correlated with the development of fibrosis (p = .10, p = .03, p = .04, p = .06, p = .09, and p = .046, respectively). The overall cosmetic outcome was good to excellent in 81.7%, fair in 11.7%, and poor in 6.7%. The presence of subcutaneous fibrosis, modified planning tumor volume/whole breast volume ratio, ratio of the volume of breast tissue receiving 5% and 20% of the prescription dose to the whole breast volume, and pathologic specimen volume correlated with the risk of a fair/poor cosmetic outcome (p < .001, p = .02, p = .05, p = .04, p = .01, respectively). Conclusion: The three-dimensional conformal radiotherapy technique for accelerated partial breast irradiation as specified in the National Surgical Adjuvant Breast and Bowel Project B-39/Radiation Therapy Oncology Group 0413 protocol resulted in a remarkably high rate of moderate-to-severe late normal tissue effects, despite the relatively brief follow-up period. The toxic events correlated clearly with several dose-volume parameters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-492: Influence of Clipping PTV in Build-Up Region On IMRT Plan Quality and Deliverability

Purpose: To study the influence of clipping PTV from body contour on plan quality and deliverability in build-up region for superficial target. Methods: Five previously treated patients of post-operative carcinoma of parotid were re-planned for IMRT (6MV X-rays, sliding window technique, five fields and 60Gy/30 fractions) using eclipse treatment planning system (TPS) by keeping dose volume constraints and all other parameters constant, only PTV was clipped from body contour by 0mm, 1mm, 2mm and 3mm respectively. Planned fluence was transferred to previously scanned solid water phantom by placing I’matriXX array at 0.5cm depth (2mm slab+3mm inherent). Fluence was delivered by Varian CL2300C/D linac at 99.5cm source to detector distance. Measured fluence was compared with TPS dose plane using 2D gamma evaluation using 3%/3mm DTA criteria. Total MU (monitor unit) required to deliver a plan was also noted. For plan quality, PTV, maximum-dose, minimum-dose, coverage index (CI=PTV volume covered by prescription dose/PTV) and heterogeneity index HI=D5/D95 were analyzed using dose volume histogram (DVH). Results: The Result of gamma function analysis for I’matriXX and TPS were 97.63±1.79%, 97.48±0.99, 98.08±0.89% and 98.01±0.78% at 0.5cm build-up depth for 0, 1, 2 and 3mm PTV clipping, respectively. I’matriXX measured dose was higher compared to TPS. Total MU required for delivering a plan were 552±61, 503±47, 436±24 and 407±22. Maximum-dose to PTV was 6635.80±62.01cGy, 6635.80±40.60cGy, 6608.43±51.07cGy and 6564.20±28.51cGy. Similarly, minimum-dose to PTV was 3306.23±458.56cGy, 3546.57±721.01cGy, 4591.43±298.81cGy and 4861.90±412.40cGy. CI was 0.9347±0.020, 0.9398±0.021, 0.9448±0.022 and 0.9481±0.021. Similarly, HI was 1.089±0.015, 1.084±0.014, 1.078±0.009 and 1.074±0.008 for 0, 1, 2 and 3mm PTV clipping, respectively. Conclusion: Gamma function analysis resulted in almost similar results. However, I’matriXX was overestimating the dose compared to TPS. MU required to deliver a plan decreases with increase in PTV clipping. CI, PTV minimum-dose and plan homogeneity increases with increase in PTV clipping from skin.

60 APPLIED LIFE SCIENCES↗

SU-E-T-615: Plan Comparison Between Photon IMRT and Proton Plans Incorporating Uncertainty Analysis

Purpose: In this study, we investigate the effect of setup uncertainty on DVH calculations which may impact plan comparison. Methods: Treatment plans (6 MV VMAT calculated on Pinnacle TPS) were chosen for different disease sites: brain, prostate, H&N and spine in this retrospective study. A proton plan (PP) using double scattering beams was generated for each selected VMAT plan subject to the same set of dose-volume constraints as in VMAT. An uncertainty analysis was incorporated on the DVH calculations in which isocenter shifts from 1 to 5 mm in each of the ±x, ±y and ±z directions were used to simulate the setup uncertainty and residual positioning errors. A total of 40 different combinations of isocenter shifts were used in the re-calculation of DVH of the PTV and the various OARs for both the VMAT and the corresponding PT. Results: For the brain case, both VMAT and PP are comparable in PTV coverage and OAR sparing, and VMAT is a clear choice for treatment due to its ease of delivery. However, when incorporating isoshifts in DVH calculations, a significant change in dose-volume relationship emerges. For example, both VMAT and PT provide adequate coverage, even with ±3mm isoshift. However, +3mm isoshift results in increase of V40(Lcochlea, VMAT) from 7.2% in the original plan to 45% and V40(R cochlea, VMAT) from 75% to 92%. For protons, V40(Lcochlea, PT) increases from 62% in the initial plan to 75%, while V40(Rcochea, PT) increases from 7% to 26%. Conclusion: DVH alone may not be sufficient to allow an unequivocal decision in plan comparison, especially when two rival plans are very similar in both PTV coverage and OAR sparing. It is a good practice to incorporate uncertainty analysis on photon and proton plan comparison studies to test the plan robustness in plan evaluation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

User's manual for the HYPGEN hyperbolic grid generator and the HGUI graphical user interface

The HYPGEN program is used to generate a 3-D volume grid over a user-supplied single-block surface grid. This is accomplished by solving the 3-D hyperbolic grid generation equations consisting of two orthogonality relations and one cell volume constraint. In this user manual, the required input files and parameters and output files are described. Guidelines on how to select the input parameters are given. Illustrated examples are provided showing a variety of topologies and geometries that can be treated. HYPGEN can be used in stand-alone mode as a batch program or it can be called from within a graphical user interface HGUI that runs on Silicon Graphics workstations. This user manual provides a description of the menus, buttons, sliders, and typein fields in HGUI for users to enter the parameters needed to run HYPGEN. Instructions are given on how to configure the interface to allow HYPGEN to run either locally or on a faster remote machine through the use of shell scripts on UNIX operating systems. The volume grid generated is copied back to the local machine for visualization using a built-in hook to PLOT3D.

Chan, William M.↗

The Effect of Dose-Volume Parameters and Interfraction Interval on Cosmetic Outcome and Toxicity After 3-Dimensional Conformal Accelerated Partial Breast Irradiation

Purpose: To evaluate dose-volume parameters and the interfraction interval (IFI) as they relate to cosmetic outcome and normal tissue effects of 3-dimensional conformal radiation therapy (3D-CRT) for accelerated partial breast irradiation (APBI). Methods and Materials: Eighty patients were treated by the use of 3D-CRT to deliver APBI at our institutions from 2003-2010 in strict accordance with the specified dose-volume constraints outlined in the National Surgical Adjuvant Breast and Bowel Project B39/Radiation Therapy Oncology Group 0413 (NSABP-B39/RTOG 0413) protocol. The prescribed dose was 38.5 Gy in 10 fractions delivered twice daily. Patients underwent follow-up with assessment for recurrence, late toxicity, and overall cosmetic outcome. Tests for association between toxicity endpoints and dosimetric parameters were performed with the chi-square test. Univariate logistic regression was used to evaluate the association of interfraction interval (IFI) with these outcomes. Results: At a median follow-up time of 32 months, grade 2-4 and grade 3-4 subcutaneous fibrosis occurred in 31% and 7.5% of patients, respectively. Subcutaneous fibrosis improved in 5 patients (6%) with extended follow-up. Fat necrosis developed in 11% of women, and cosmetic outcome was fair/poor in 19%. The relative volume of breast tissue receiving 5%, 20%, 50%, 80%, and 100% (V5-V100) of the prescribed dose was associated with risk of subcutaneous fibrosis, and the volume receiving 50%, 80%, and 100% (V50-V100) was associated with fair/poor cosmesis. The mean IFI was 6.9 hours, and the minimum IFI was 6.2 hours. The mean and minimum IFI values were not significantly associated with late toxicity. Conclusions: The incidence of moderate to severe late toxicity, particularly subcutaneous fibrosis and fat necrosis and resulting fair/poor cosmesis, remains high with continued follow-up. These toxicity endpoints are associated with several dose-volume parameters. Minimum and mean IFI values were not associated with late toxicity.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Launch vehicle performance using metallized propellants

Metallized propellant propulsion systems are considered as replacements for the solid rocket boosters and liquid sustainer stages on the current launch vehicles: both the Space Transportation System (STS) and the Titan 4. Liquid rocket boosters for the STS were analyzed as replacements for current solid rocket boosters. These boosters can provide a liquid propulsion system within the volume constraints of a solid rocket booster. A replacement for the Space Shuttle Main Engines using metallized O2/H2/Al was studied. The liquid stages of the Titan 4 were also investigated; the Aerozine-50 (A-50) fuel was replaced with metallized storable A-50/Al. A metallized propellant is similar to a traditional liquid propellant. However, it has metal particles, such as aluminum, that are suspended in a gelled fuel, such as hydrogen, RP-1, A-50 or monomethyl hydrazine (MMH). The fuels then undergo combustion with liquid oxygen or nitrogen tetroxide (NTO). These propellants provide options for increasing the performance of existing launch vehicle chemical propulsion systems by increasing fuel density or specific impulse or both. These increases in density and specific impulse can significantly reduce the propulsion system liftoff weight and allow a liquid rocket booster to fit into the same volume as an existing solid rocket booster. Also, because gelled fuels are akin to liquid propellants, metallized systems can provide enhanced controllability over solid propulsion systems. Gelling of the propellant also reduces the sensitivity to impacts and consequently reduces the propellant explosion hazard.

Palaszewski, Bryan A.↗

Launch vehicle performance using metallized propellants

Metallized propellant propulsion systems are considered as replacements for the solid rocket boosters and liquid sustainer stages on the current launch vehicles: both the Space Transportation System (STS) and the Titan 4. Liquid rocket boosters for the STS were analyzed as replacements for current solid rocket boosters. These boosters can provide a liquid propulsion system within the volume constraints of a solid rocket booster. A replacement for the Space Shuttle Main Engines using metallized 02/H2/A1 was studied. The liquid stages of the Titan 4 were also investigated; the Aerozine-50 (A-50) fuel was replaced with metallized storable A-50/A1. A metallized propellant is similar to a traditional liquid propellant. However, it has metal particles, such as aluminum, that are suspended in a gelled fuel, such as hydrogen, RP-1, A-50 or monomethyl hydrazine (MMH). The fuels then undergo combustion with liquid oxygen or nitrogen tetroxide (NTO). These propellants provide options for increasing the performance of existing launch vehicle chemical propulsion systems by increasing fuel density or specific impulse or both. These increases in density and specific impulse can significantly reduce the propulsion system liftoff weight and allow a liquid rocket booster to fit into the same volume as an existing solid rocket booster. Also, because gelled fuels are akin to liquid propellants, metallized systems can provide enhanced controllability over solid propulsion systems. Gelling of the propellant also reduces the sensitivity to impacts and consequently reduces the propellant explosion hazard.

Palaszewski, Bryan↗

Computational needs survey of NASA automation and robotics missions. Volume 1: Survey and results

NASA's operational use of advanced processor technology in space systems lags behind its commercial development by more than eight years. One of the factors contributing to this is that mission computing requirements are frequently unknown, unstated, misrepresented, or simply not available in a timely manner. NASA must provide clear common requirements to make better use of available technology, to cut development lead time on deployable architectures, and to increase the utilization of new technology. A preliminary set of advanced mission computational processing requirements of automation and robotics (A&R) systems are provided for use by NASA, industry, and academic communities. These results were obtained in an assessment of the computational needs of current projects throughout NASA. The high percent of responses indicated a general need for enhanced computational capabilities beyond the currently available 80386 and 68020 processor technology. Because of the need for faster processors and more memory, 90 percent of the polled automation projects have reduced or will reduce the scope of their implementation capabilities. The requirements are presented with respect to their targeted environment, identifying the applications required, system performance levels necessary to support them, and the degree to which they are met with typical programmatic constraints. Volume one includes the survey and results. Volume two contains the appendixes.

Davis, Gloria J.↗