Search NASA⌕ Search

SEARCH · Search NASA

Results for “WALL TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Effect of a surface-to-gap temperature discontinuity on the heat transfer to reusable surface insulation tile gaps

An experimental investigation is presented that was performed to determine the effect of a surface-to-gap wall temperature discontinuity on the heat transfer within space shuttle, reusable surface insulation, tile gaps submerged in a thick turbulent boundary layer. Heat-transfer measurements were obtained on a flat-plate, single-gap model submerged in a turbulent tunnel wall boundary layer at a nominal free-stream Mach number of 10.3 and free-stream Reynolds numbers per meter of 1.5 million, 3.3 million and 7.8 million. Surface-to-gap wall temperature discontinuities of varying degree were created by heating the surface of the model upstream of the instrumented gap. The sweep angle of the gap was varied between 0 deg and 60 deg; gap width and depth were held constant. A surface-to-gap wall temperature discontinuity (surface temperature greater than gap wall temperature) results in increased heat transfer to the near-surface portion of the gap, as compared with the heat transfer under isothermal conditions, while decreasing the heat transfer to the deeper portions of the gap. The nondimensionalized heat transfer to the near-surface portion of the gap is shown to decrease with increasing Reynolds number; in the deeper portion of the gap, the heat transfer increases with Reynolds number.

Throckmorton, D. A.↗

Experimental investigation of the heat-transfer characteristics of an air-cooled sintered porous turbine blade

The results of a heat-transfer investigation on a transpiration-cooled turbine blade are presented. The investigation was made on a static cascade.506::Declassified December 11, 1953. Blade-peripheral wall-temperature distributions were measured and compared with the temperature distribution on a convection-cooled blade. A correlation of the blade-wall temperatures obtained at various gas temperatures and gas weight flows was made on the basis of a temperature-difference ratio. Blade-wall temperatures calculated using an approximate theory for turbulent flow are compared with the measured blade-wall tempeartures.

Schafer, Louis J , Jr↗

RP-2 Thermal Stability and Heat Transfer Investigation for Hydrocarbon Boost Engines

A series of electrically heated tube tests were performed at the NASA Glenn Research Center s Heated Tube Facility to investigate the use of RP-2 as a fuel for next generation regeneratively cooled hydrocarbon boost engines. The effect that test duration, operating condition and test piece material have on the overall thermal stability and materials compatibility characteristics of RP-2 were evaluated using copper and 304 stainless steel test sections. The copper tests were run at 1000 psia, heat flux up to 6.0 Btu/in.2-sec, and wall temperatures up to 1180 F. Preliminary results, using measured wall temperature as an indirect indicator of the carbon deposition process, show that in copper test pieces above approximately 850 F, RP-2 begins to undergo thermal decomposition resulting in local carbon deposits. Wall temperature traces show significant local temperature increases followed by near instantaneous drops which have been attributed to the carbon deposition/shedding process in previous investigations. Data reduction is currently underway for the stainless steel test sections and carbon deposition measurements will be performed in the future for all test sections used in this investigation. In conjunction with the existing thermal stability database, these findings give insight into the feasibility of cooling a long life, high performance, high-pressure liquid rocket combustor and nozzle with RP-2.

VanNoord, J. L.↗

Local Heat-Transfer Measurements for Forced Convection of Hydrogen and Helium at Surface Temperatures Up to 5600 Deg R

Local values of heat-transfer coefficients and average friction coefficients were measured experimentally for helium and hydrogen gas flowing through an electrically heated tungsten tube with a length-diameter ratio of 77 for the following range of conditions: local surface temperatures up to 5600° R, local Reynolds number from 7600 to,39,500, local ratios of surface-to-bulk gas temperature up to 5.6, and heat flux up to 1,700,000 Btu per hour per square foot. A comparison of local heat-transfer coefficients for helium and hydrogen gas is made for several types of wall temperature distribution, which determines whether the data can be correlated by a Dittus-Boelter type equation. A wall temperature distribution for hydrogen is compared with one for helium and found to be essentially the same; this result demonstrates that q dissociation of hydrogen at the tube wall for wall temperatures up to 5200O R has little or no effect on the wall temperature distribution.

Maynard F Taylor↗

Effects of Wall Cooling on Supersonic Modes in High-Enthalpy Hypersonic Boundary Layers over a Cone

High-enthalpy hypersonic boundary-layer transition plays an important role in many entry/descent vehicles. Aerothermodynamic performance of these vehicles strongly depends on the transition location on the surface. However, detailed transition flow physics in these chemically reacting boundary layers are poorly understood and transition estimates during the design phase rely heavily on empirically-derived transition criteria such as 𝑹𝒆(𝜽)/𝑴(𝒆). One of the most intriguing characteristics in hypersonic boundary layers is the presence of unstable supersonic modes, first identified in the 1990s. Due to a recent surge in hypersonic applications, there has been renewed interest in studying the flow physics of supersonic modes using either theory or direct numerical simulations. This paper investigates the rise of supersonic modes in a high-enthalpy hypersonic flow over a 𝟓° half-angle cone at various wall temperatures using both quasiparallel linear stability theory and linear PSE. It was found that supersonic modes exist in all wall temperature conditions including the adiabatic wall case. Cooler wall temperature causes the second Mack mode to become an unstable supersonic mode naturally downstream of the upper-branch neutral location when the wall is sufficiently cooled. In terms of the integrated growth, the second mode is still the dominant mode. Nonetheless, supersonic modes can cause additional series of relatively weaker growth than that of the second mode beyond the peak amplitude location. According to the present linear PSE results, contrary to what was speculated in the literature, supersonic-mode pressure disturbance structure radiated into the freestream is nonacoustic in nature and the formation of unstable supersonic modes is mainly associated with the synchronization of phase speed between the instability and acoustic waves in a nonp ayer, not due to nonlinear modal interaction as suggested in the literature.

Chang, Chau-Lyan↗

PARCEQ2D heat transfer grid sensitivity analysis

The material presented in this paper is an extension of two-dimensional Aeroassist Flight Experiment (AFE) results shown previously. This study has focused on the heating rate calculations to the AFE obtained from an equilibrium real gas code, with attention placed on the sensitivity of grid dependence and wall temperature. Heat transfer results calculated by the PARCEQ2D code compare well with those computed by other researchers. Temperature convergence in the case of kinetic transport has been accomplished by increasing the wall temperature gradually from 300 K to the wall temperature of 1700 K.

Saladino, Anthony J.↗

Effect of wall cooling on the stability of compressible subsonic flows over smooth humps and backward-facing steps

The effect of wall cooling on the two-dimensional linear stability of subsonic flows over two-dimensional surface imperfections is investigated. Results are presented for flows over smooth humps and backward-facing steps with Mach numbers up to 0.8. The results show that, whereas cooling decreases the viscous instability, it increases the shear-layer instability and hence it increases the growth rates in the separation region. The coexistence of more than one instability mechanism makes a certain degree of wall cooling most effective. For the Mach numbers 0.5 and 0.8, the optimum wall temperatures are about 80 pct and 60 pct of the adiabatic wall temperature, respectively. Increasing the Mach number decreases the effectiveness of cooling slightly and reduces the optimum wall temperature.

Al-Maaitah, Ayman A.↗

Effect of wall cooling on the stability of compressible subsonic flows over smooth humps and backward-facing steps

The effect of wall cooling on the two-dimensional linear stability of subsonic flows over two-dimensional surface imperfections is investigated. Results are presented for flows over smooth humps and backward-facing steps with Mach numbers up to 0.8. The results show that, whereas cooling decreases the viscous instability, it increases the shear-layer instability and hence it increases the growth rates in the separation region. The coexistence of more than one instability mechanism makes a certain degree of wall cooling most effective. For the Mach numbers 0.5 and 0.8, the optimum wall temperatures are about 80 pct and 60 pct of the adiabatic wall temperature, respectively. Increasing the Mach number decreases the effectiveness of cooling slightly and reduces the optimum wall temperature.

Al-Maaitah, Ayman A.↗

Ground testing for the no-vent fill of cryogenic tanks - Results of tests for a 71 cubic foot tank

NASA Lewis Research has been investigating the no-vent till method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. Twenty two tests were conducted, ten with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia; transfer pressures of 20, 30, and 45 psia; and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool-down of the higher starting wall temperature fills.

Chato, David J.↗

Ground testing for the no-vent fill of cryogenic tanks: Results of tests for a 71 cubic foot tank

NASA Lewis Research has been investigating the no-vent fill method, since it is a promising approach to transfer liquid while handling the problems of low-g venting. This paper reports the results of a test series for filling a 71 cu ft tank with liquid hydrogen without venting. 22 tests were conducted, 10 with a bottom orifice as the inlet and 12 with a spray bar. Parameters investigated included inlet saturation pressures of approximately 5, 15, and 25 psia, transfer pressures of 20, 30, and 45 psia, and various starting wall temperatures. Of the tests, only the one run at the highest wall temperature (238 R) failed to fill the tank. Test results are compared to a thermodynamic equilibrium model. Overall model-data agreement was good except for the tendency of the model to overshoot during the initial wall cool down of the higher starting wall temperature fills.

Chato, David J.↗

A dual-cooled hydrogen-oxygen rocket engine heat transfer analysis

The potential benefits of simultaneously using hydrogen and oxygen as rocket engine coolants are described. A plug-and-spool rocket engine was examined at heat fluxes ranging from 9290 to 163,500 kW/sq m, using a combined 3-D conduction/advection analysis. Both counter flow and parallel flow cooling arrangements were analyzed. The results indicate that a significant amount of heat transfer to the oxygen occurs, reducing both the hot side wall temperature of the rocket engine and also reducing the exit temperature of the hydrogen coolant. In all heat flux and coolant flow rates examined, the total amount of heat transferred to the oxygen was found to be largely independent of the oxygen coolant flow direction. At low heat flux/low coolant flow (throttled) conditions, the oxygen coolant absorbed more than 30 percent of the overall heat transfer from the rocket engine exhaust gasses. Also, hot side wall temperatures were judged to decrease by approximately 120 K in the throat area and up to a 170 K combustion chamber wall temperature reduction is expected if dual cooling is applied. The reduction in combustion chamber wall temperatures at throttled conditions is especially desirable since tha analysis indicates that a double temperature maxima, one at the throat and another in the combustion chamber, occurs with a traditional hydrogen cooled only engine. Conversely, a dual cooled engine essentially eliminates any concern for overheating in the combustion chamber.

Kacynski, Kenneth J.↗

LES-Based Analysis of Film Cooling in a High-Pressure Turbine Rotor Including Effects of Purge and Tip Flow

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Secondary Flows↗

A GPU-based Approach for Turbomachinery Application

Accurate modeling of coolant airflows, which form protective films over turbine blades, is essential for designing fuel-efficient and environmentally sustainable gas turbine engines. Excessive coolant reduces thermal efficiency, while insufficient coolant leads to blade overheating and causes damage. Therefore, precise prediction of flow field interactions with cooling air is critical for optimizing turbine performance. This study numerically investigates the cooling effectiveness of purge and film cooling flows within a high-pressure turbine (HPT) rotor using Large Eddy Simulation (LES). The study utilizes NASA Glenn Research Center’s Glenn-HT solver. The simulation models ethe conditions of the Penn State University START rotating rig. A high-fidelity structured mesh comprising up to 800 million cells is employed to resolve high-Reynolds number flow (Re ≈ 350,000) and to capture intricate secondary flow structures, including tip leakage and purge-induced vortices. Film cooling effectiveness computations are highly sensitive to boundary conditions at the cooling holes and to grid resolution. Even with well-resolved grids and included plena, strong mixing challenges traditional eddy viscosity models. To address this, a simplified configuration is simulated: a truncated row of shaped holes on the suction side near the leading edge and a row on the pressure side, both fed from internal plena while the purge slot and tip clearance are also modeled. Two isothermal LES cases are conducted at two distinct wall temperatures, which yield the adiabatic wall temperature and the heat transfer coefficient. The definition and means of computation of the effectiveness is discussed in this paper. The simulations reveal detailed three-dimensional unsteady flow features, including coherent vortical structures and secondary flows originating from the purge cavity. Film cooling effectiveness and Nusselt number distributions are presented for both the blade surface and tip, highlighting regions of elevated heat transfer and complex thermal behavior. These findings underscore the importance of high-resolution LES and realistic boundary conditions in capturing the dynamics of purge and film cooling, offering valuable insights for improving turbine blade design and thermal management strategies.

Gas Turbine↗

Development of a Polysilicon Process Based on Chemical Vapor Deposition of Dichlorosilane in an Advanced Siemen's Reactor

Dichlorosilane (DCS) was used as the feedstock for an advanced decomposition reactor for silicon production. The advanced reactor had a cool bell jar wall temperature, 300 C, when compared to Siemen's reactors previously used for DCS decomposition. Previous reactors had bell jar wall temperatures of approximately 750 C. The cooler wall temperature allows higher DCS flow rates and concentrations. A silicon deposition rate of 2.28 gm/hr-cm was achieved with power consumption of 59 kWh/kg. Interpretation of data suggests that a 2.8 gm/hr-cm deposition rate is possible. Screening of lower cost materials of construction was done as a separate program segment. Stainless Steel (304 and 316), Hastalloy B, Monel 400 and 1010-Carbon Steel were placed individually in an experimental scale reactor. Silicon was deposited from trichlorosilane feedstock. The resultant silicon was analyzed for electrically active and metallic impurities as well as carbon. No material contributed significant amounts of electrically active or metallic impurities, but all contributed carbon.

Arevidson, A. N.↗

Comparison of two procedures for predicting rocket engine nozzle performance

Two nozzle performance prediction procedures which are based on the standardized JANNAF methodology are presented and compared for four rocket engine nozzles. The first procedure required operator intercedence to transfer data between the individual performance programs. The second procedure is more automated in that all necessary programs are collected into a single computer code, thereby eliminating the need for data reformatting. Results from both procedures show similar trends but quantitative differences. Agreement was best in the predictions of specific impulse and local skin friction coefficient. Other compared quantities include characteristic velocity, thrust coefficient, thrust decrement, boundary layer displacement thickness, momentum thickness, and heat loss rate to the wall. Effects of wall temperature profile used as an input to the programs was investigated by running three wall temperature profiles. It was found that this change greatly affected the boundary layer displacement thickness and heat loss to the wall. The other quantities, however, were not drastically affected by the wall temperature profile change.

Davidian, Kenneth J.↗

Comparison of two procedures for predicting rocket engine nozzle performance

Two nozzle performance prediction procedures which are based on the standardized JANNAF methodology are presented and compared for four rocket engine nozzles. The first procedure required operator intercedence to transfer data between the individual performance programs. The second procedure is more automated in that all necessary programs are collected into a single computer code, thereby eliminating the need for data reformatting. Results from both procedures show similar trends but quantitative differences. Agreement was best in the predictions of specific impulse and local skin friction coefficient. Other compared quantities include characteristic velocity, thrust coefficient, thrust decrement, boundary layer displacement thickness, momentum thickness, and heat loss rate to the wall. Effects of wall temperature profile used as an input to the programs was investigated by running three wall temperature profiles. It was found that this change greatly affected the boundary layer displacement thickness and heat loss to the wall. The other quantities, however, were not drastically affected by the wall temperature profile change.

Davidian, Kenneth J.↗

Deposit formation in hydrocarbon rocket fuels: Executive summary

An experimental program was conducted to study deposit formation in hydrocarbon fuels under flow conditions that exist in high-pressure, rocket engine cooling systems. A high pressure fuel coking test apparatus was designed and developed and was used to evaluate thermal decomposition (coking) limits and carbon deposition rates in heated copper tubes for two hydrocarbon rocket fuels, RP-1 and commercial-grade propane. Tests were also conducted using JP-7 and chemically-pure propane as being representative of more refined cuts of the baseline fuels. A parametric evaluation of fuel thermal stability was performed at pressures of 136 atm to 340 atm, bulk fuel velocities in the range 6 to 30 m/sec, and tube wall temperatures in the range 422 to 811K. In addition, the effect of the inside wall material on deposit formation was evaluated in selected tests which were conducted using nickel-plated tubes. The results of the tests indicated that substantial deposit formation occurs with RP-1 fuel at wall temperatures between 600 and 800K, with peak deposit formation occurring near 700K. No improvements were obtained when de-oxygenated JP-7 fuel was substituted for RP-1. The carbon deposition rates for the propane fuels were generally higher than those obtained for either of the kerosene fuels at any given wall temperature. There appeared to be little difference between commercial-grade and chemically-pure propane with regard to type and quantity of deposit. The results of tests conducted with RP-1 indicated that the rate of deposit formation increased slightly with pressure over the range 136 atm to 340 atm. Finally, plating the inside wall of the tubes with nickel was found to significantly reduce carbon deposition rates for RP-1 fuel.

Roback, R.↗

Full-coverage film cooling

Transpiration cooling is treated and then full coverage discrete hole injection for three injection orientations. Spacings with pitch to diameter ratios of 5 and 10 are discussed. The array is staggered, with the transverse pitch and the streamwise pitch the same. Results are presented in terms of the Stanton number using the heat transfer coefficient defined in terms of the difference between the wall temperature and the free stream temperature. Two values of Stanton number are provided for each situation: one with the injectant at wall temperature, and the other with the injectant at free stream temperature. These two values are equivalent to knowing the heat transfer coefficient and the adiabatic effectiveness. The heat transfer coefficient thus defined is used with the actual wall temperature to and the actual gas temperature to calculate the heat load. The principle of superposition thus invoked is valid exactly when the governing equations are linear.

Moffat, R. J.↗