Search NASA⌕ Search

SEARCH · Search NASA

Results for “WIDTH”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A slippery slope: systematic uncertainties in the line width baryonic Tully-Fisher relation

The baryonic Tully–Fisher relation (BTFR) is both a valuable observational tool and a critical test of galaxy formation theory. We explore the systematic uncertainty in the slope and the scatter of the observed line-width BTFR utilizing homogeneously measured, unresolved H i observations for 930 isolated galaxies. We measure a fiducial relation of log{sub 10} M{sub baryon}=3.24 log{sub 10} V{sub rot} + 3.21 with observed scatter of 0.25 dex over a baryonic mass range of 10{sup 7.4} to 10{sup 11.3} M{sub ⊙} where V{sub rot} is measured from 20% H i line widths. We then conservatively vary the definitions of M{sub baryon} and V{sub rot}, the sample definition and the linear fitting algorithm. We obtain slopes ranging from 2.64 to 3.53 and scatter measurements ranging from 0.14 to 0.41 dex, indicating a significant systematic uncertainty of 0.25 in the BTFR slope derived from unresolved H i line widths. We next compare our fiducial slope to literature measurements, where reported slopes range from 3.0 to 4.3 and scatter is either unmeasured, immeasurable, or as large as 0.4 dex. Measurements derived from unresolved H i line widths tend to produce slopes of 3.3, while measurements derived strictly from resolved asymptotic rotation velocities tend to produce slopes of 3.9. The single largest factor affecting the BTFR slope is the definition of rotation velocity. The sample definition, the mass range and the linear fitting algorithm also significantly affect the measured BTFR. We find that galaxies in our sample with V{sub rot}<100 km s{sup −1} are consistent with the line-width BTFR of more massive galaxies, but these galaxies drive most of the observed scatter. It is critical when comparing predictions to an observed BTFR that the rotation velocity definition, the sample selection and the fitting algorithm are similarly defined. We recommend direct statistical comparisons between data sets with commensurable properties as opposed to simply comparing BTFR power-law fits.

79 ASTRONOMY AND ASTROPHYSICS↗

Modeling of dislocation channel width evolution in irradiated metals

Defect-free dislocation channel formation has been reported to promote plastic instability during tensile testing via localized plastic flow, leading to a distinct loss of ductility and strain hardening in many low-temperature irradiated materials. In order to study the underlying mechanisms governing dislocation channel width and formation, the channel formation process is modeled via a simple stochastic dislocation-jog process dependent upon grain size, defect cluster density, and defect size. Dislocations traverse a field of defect clusters and jog stochastically upon defect interaction, forming channels of low defect-density. And based upon prior molecular dynamics (MD) simulations and in-situ experimental transmission electron microscopy (TEM) observations, each dislocation encounter with a dislocation loop or stacking fault tetrahedron (SFT) is assumed to cause complete absorption of the defect cluster, prompting the dislocation to jog up or down by a distance equal to half the defect cluster diameter. Channels are predicted to form rapidly and are comparable to reported TEM measurements for many materials. Predicted channel widths are found to be most strongly dependent on mean defect size and correlated well with a power law dependence on defect diameter and density, and distance from the dislocation source. Due to the dependence of modeled channel width on defect diameter and density, maximum channel width is predicted to slowly increase as accumulated dose increases. The relatively weak predicted dependence of channel formation width with distance, in accordance with a diffusion analogy, implies that after only a few microns from the source, most channels observed via TEM analyses may not appear to vary with distance because of limitations in the field-of-view to a few microns. Furthermore, examinations of the effect of the so-called “source-broadening” mechanism of channel formation showed that its effect is simply to add a minimum thickness to the channel without affecting channel dependence on the given parameters.

36 MATERIALS SCIENCE↗

Effect of MLC Leaf Width and PTV Margin on the Treatment Planning of Intensity-Modulated Stereotactic Radiosurgery (IMSRS) or Radiotherapy (IMSRT)

We studied the effect of MLC (multileaf collimator) leaf width and PTV (planning target volume) margin on treatment planning of intensity modulated stereotactic radiosurgery (IMSRS) or radiotherapy (IMSRT). Twelve patients previously treated with IMSRS/IMSRT were retrospectively planned with 5- and 3-mm MLC leaf widths and 3- and 2-mm PTV margins using the already contoured clinical target volume and critical structures. The same beam arrangement, planning parameters, and optimization method were used in each of the 4 plans for a given patient. Each plan was normalized so that the prescription dose covered at least 99% of the PTV. Plan indices - D{sub mean} (mean dose), conformity index (CI), V{sub 70} (volume receiving {>=} 70% of the prescription dose), and V{sub 50} (volume receiving {>=} 50% of the prescription dose) - were calculated from the dose-volume histograms (DVHs) of the PTV, normal tissue, and organs at risk (OARs). Hypothesis testing was performed on the mean ratios of plan indices to determine the statistical significance of the relative differences. The PTV was well covered for all plans, as no significant differences were observed for D{sub 95}, V{sub 95}, D{sub max}, D{sub min}, and D{sub mean} of the PTV. The irradiated volume was {approx}23% smaller when 2-mm instead of 3-mm PTV margin was used, but it was only reduced by {approx}6% when the MLC leaf width was reduced from 5 mm to 3 mm. For normal tissue and brainstem, V{sub 70}, V{sub 50}, and D{sub mean} were reduced more effectively by a decrease in MLC width, while D{sub mean} of optic nerve and chiasm were more sensitive to a change in PTV margin. The DVH statistics for the PTV and normal structures from the treatment plan with 5-mm MLC and 2-mm PTV margin were equal to those with 3-mm MLC and 3-mm PTV margin. PTV margin reduction is more effective in sparing the normal tissue and OARs than a reduction in MLC leaf width. For IMSRS, where highly accurate setup and small PTV margins are routinely employed, the use of 5-mm MLC is therefore less desirable.

61 RADIATION PROTECTION AND DOSIMETRY↗

Investigation of Pitch and Jaw Width to Decrease Delivery Time of Helical Tomotherapy Treatments for Head and Neck Cancer

Helical tomotherapy plans using a combination of pitch and jaw width settings were developed for 3 patients previously treated for head and neck cancer. Three jaw widths (5, 2.5, and 1 cm) and 4 pitches (0.86, 0.43, 0.287, and 0.215) were used with a (maximum) modulation factor setting of 4. Twelve plans were generated for each patient using an identical optimization procedure (e.g., number of iterations, objective weights, and penalties, etc.), based on recommendations from TomoTherapy (Madison, WI). The plans were compared using isodose plots, dose volume histograms, dose homogeneity indexes, conformity indexes, radiobiological models, and treatment times. Smaller pitches and jaw widths showed better target dose homogeneity and sparing of normal tissue, as expected. However, the treatment time increased inversely proportional to the jaw width, resulting in delivery times of 24 {+-} 1.9 min for the 1-cm jaw width. Although treatment plans produced with the 2.5-cm jaw were dosimetrically superior to plans produced with the 5-cm jaw, subsequent calculations of tumor control probabilities and normal tissue complication probabilities suggest that these differences may not be radiobiologically meaningful. Because treatment plans produced with the 5-cm jaw can be delivered in approximately half the time of plans produced with the 2.5-cm jaw (5.1 {+-} 0.6 min vs. 9.5 {+-} 1.1 min), use of the 5-cm jaw in routine treatment planning may be a viable approach to decreasing treatment delivery times from helical tomotherapy units.

61 RADIATION PROTECTION AND DOSIMETRY↗

Can cost make a difference dosimetrically? Volumetric modulated arc therapy study for multileaf collimators of various widths for head and neck and prostate cancers

Cancer is a global health issue that disproportionately kills based on stage of disease, cellular pathology, and genetics, to name a few. Another variable to consider in this ongoing fight is treatment machine complexity that leads to elevated development and purchasing cost, leading to a reduced use. Reducing the complexity (in hopes of lowering costs) would benefit underdeveloped, low- and middle-income countries by introducing newer treatment technology, as their currently accepted standards do not meet standards of more advanced, developed countries. In this study, unilateral head and neck (H&N), and prostate cases using volumetric modulated arc therapy (VMAT) were tested with multiple segment widths of 5, 10, 15, and 20 mm to create treatable plans. Pinnacle 9.10v was used for planning purposes. A total of 12 cases were planned with varying multileaf collimator (MLC) widths. Treatment plans were evaluated retrospectively. Results show that altering the MLC widths from 5 through 20 mm produces both comparable and treatable plans up to 99% and 98% target coverage for H&N and prostate, respectively, albeit clinically significant hot spots were shown to increase with increasing segment width. Furthermore, the results show that increasing widths can produce comparable treatment plans as measured against our current Food and Drug Administration (FDA)–approved treatment devices—leading to an increase in treatment efficacy in economically underdeveloped countries.

61 RADIATION PROTECTION AND DOSIMETRY↗

Dosimetric effect of multileaf collimator leaf width on volumetric modulated arc stereotactic radiotherapy for spine tumors

This work aimed to study the dosimetric effect of multileaf collimator (MLC) leaf widths in treatment plans for patients receiving volumetric modulated arc therapy (VMAT) for spine stereotactic body radiation therapy (SBRT). Thirteen patients treated with spine SBRT were retrospectively selected for this study. The patients were treated following the protocol of the Radiation Therapy Oncology Group 0631 (RTOG 0631) for spine metastasis. The prescription dose was 16 Gy in 1 fraction to 90% of the target volume (V16 > 90%). The maximum spinal cord dose of 14 Gy and 10% of the spinal cord receiving < 10 Gy (V10) were the acceptable tolerance doses. For the purpose of this study, 2 dual-arc VMAT plans were created for each patient using 3 different MLC leaf widths: 2.5 mm, 4 mm, and 5 mm. The compliance with the RTOG 0631 protocol, conformity index (CI), dose gradient index (DGI), and number of monitor units (MUs) were compared. The average V16Gy of the targets was 91.8 ± 1.2%, 92.2 ± 2.1%, and 91.7 ± 2.3% for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively (p = 0.78). Accordingly, the average CI was 1.45 ± 0.4, 1.47 ± 0.29, and 1.47 ± 0.31 (p = 0.98), respectively. The average DGI was 0.22 ± 0.04, 0.20 ± 0.06, and 0.22 ± 0.05, respectively (p = 0.77). The average maximum dose to the spinal cord was 12.45 ± 1.0 Gy, 12.80 ± 1.0 Gy, and 12.48 ± 1.1 (p = 0.62) and V10% of the spinal cord was 3.6 ± 2.1%, 5.6 ± 2.8%, and 5.5 ± 3.0% (p = 0.11) for 2.5-mm, 4-mm, and 5-mm leaf widths, respectively. Accordingly, the average number of MUs was 4341 ± 500 MU, 5019 ± 834 MU, and 4606 ± 691 MU, respectively (p = 0.053). The use of 2.5-mm, 4-mm, and 5-mm MLCs achieved similar VMAT plan quality as recommended by the RTOG 0631. The dosimetric parameters were also comparable for the 3 MLCs. In general, any of these leaf widths can be used for spine SBRT using VMAT.

61 RADIATION PROTECTION AND DOSIMETRY↗

Turbulence spreading effects on the ELM size and SOL width

BOUT++ turbulence simulations were performed to investigate the impact of turbulence spreading on the edge localized mode (ELM) size and divertor heat flux width (λ q ) broadening in small ELM regimes. Here, this study is motivated by EAST experiments. BOUT++ linear simulations of a pedestal radial electric field (E r ) scan show that the dominant toroidal number mode (n) shifts from high-n to low-n, with a narrow mode spectrum, and the maximum linear growth rate increases as the pedestal E r well deepens. The nonlinear simulations show that as the net E × B pedestal flow increases, the pressure fluctuation level and its inward penetration beyond the top of the pedestal both increase. This leads to a transition from small ELMs to large ELMs. Both inward and outward turbulence spreading are sensitive to the scrape-off-layer (SOL) plasma profiles. The inward turbulence spreading increases for the steep SOL profiles, leading to increasing pedestal energy loss in the small ELM regime. The SOL width (λ q ) is significantly broadened progressing from the ELM-free to small ELM regime, due to the onset of strong radial turbulent transport. The extent of the SOL width (λ q ) broadening depends strongly on outward turbulence spreading. The fluctuation energy intensity flux Γ ε at the separatrix can be enhanced by increasing either pedestal E r flow shear or local SOL pressure gradient. The λ q is broadened as the fluctuation energy intensity flux Γ ε at the last close flux surface (LCFS) increases. Local SOL E × B flow shear will restrain outward turbulence spreading and the associated heat flux width broadening. Operating in H-mode with small ELMs has the potential to solve two critical problems: reducing the ELM size and broadening the SOL width.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Oscillation-like diffusion of two-dimensional liquid dusty plasmas on one-dimensional periodic substrates with varied widths

The long-time diffusion of two-dimensional dusty plasmas on a one-dimensional periodic substrate with varying widths is investigated using Langevin dynamical simulations. When the substrate is narrow and the dust particles form a single row, the diffusion is the smallest in both directions. In this study, we find that as the substrate width gradually increases to twice its initial value, the long-time diffusion of the two-dimensional dusty plasmas first increases, then decreases, and finally increases again, giving an oscillation-like diffusion with varying substrate widths. When the width increases to a specific value, the dust particles within each potential well arrange themselves in a stable zigzag pattern, greatly reducing the diffusion and leading to the observed oscillation in the diffusion with the increase in the width. In addition, the long-time oscillation-like diffusion is consistent with the number of dust particles that are hopping across the potential wells of the substrate.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ENERGY-DEPENDENT GAMMA-RAY BURST PULSE WIDTH DUE TO THE CURVATURE EFFECT AND INTRINSIC BAND SPECTRUM

Previous studies have found that the width of the gamma-ray burst (GRB) pulse is energy dependent and that it decreases as a power-law function with increasing photon energy. In this work we have investigated the relation between the energy dependence of the pulse and the so-called Band spectrum by using a sample including 51 well-separated fast rise and exponential decay long-duration GRB pulses observed by BATSE (Burst and Transient Source Experiment on the Compton Gamma Ray Observatory). We first decompose these pulses into rise and decay phases and find that the rise widths and the decay widths also behave as a power-law function with photon energy. Then we investigate statistically the relations between the three power-law indices of the rise, decay, and total width of the pulse (denoted as {delta}{sub r}, {delta}{sub d}, and {delta}{sub w}, respectively) and the three Band spectral parameters, high-energy index ({alpha}), low-energy index ({beta}), and peak energy (E{sub p} ). It is found that (1) {alpha} is strongly correlated with {delta}{sub w} and {delta}{sub d} but seems uncorrelated with {delta}{sub r}; (2) {beta} is weakly correlated with the three power-law indices, and (3) E{sub p} does not show evident correlations with the three power-law indices. We further investigate the origin of {delta}{sub d}-{alpha} and {delta}{sub w}-{alpha}. We show that the curvature effect and the intrinsic Band spectrum could naturally lead to the energy dependence of the GRB pulse width and also the {delta}{sub d}-{alpha} and {delta}{sub w}-{alpha} correlations. Our results hold so long as the shell emitting gamma rays has a curved surface and the intrinsic spectrum is a Band spectrum or broken power law. The strong {delta}{sub d}-{alpha} correlation and inapparent correlations between {delta}{sub r} and the three Band spectral parameters also suggest that the rise and decay phases of the GRB pulses have different origins.

79 ASTRONOMY AND ASTROPHYSICS↗

FREQUENCY DEPENDENCE OF PULSE WIDTH FOR 150 RADIO NORMAL PULSARS

The frequency dependence of the pulse width is studied for 150 normal pulsars, mostly selected from the European Pulsar Network, for which the 10% multifrequency pulse widths can be well fit with the Thorsett relationship W {sub 10} = Aν{sup μ} + W {sub 10,} {sub min}. The relative fraction of pulse width change between 0.4 GHz and 4.85 GHz, η = (W {sub 4.85} – W {sub 0.4})/W {sub 0.4}, is calculated in terms of the best-fit relationship for each pulsar. It is found that 81 pulsars (54%) have η < –10% (group A), showing considerable profile narrowing at high frequencies, 40 pulsars (27%) have –10% ≤η ≤ 10% (group B), meaning a marginal change in pulse width, and 29 pulsars (19%) have η > 10% (group C), showing a remarkable profile broadening at high frequencies. The fractions of the group-A and group-C pulsars suggest that the profile narrowing phenomenon at high frequencies is more common than the profile broadening phenomenon, but a large fraction of the group-B and group-C pulsars (a total of 46%) is also revealed. The group-C pulsars, together with a portion of group-B pulsars with slight pulse broadening, can hardly be explained using the conventional radius-to-frequency mapping, which only applies to the profile narrowing phenomenon. Based on a recent version of the fan beam model, a type of broadband emission model, we propose that the diverse frequency dependence of pulse width is a consequence of different types of distribution of emission spectra across the emission region. The geometrical effect predicting a link between the emission beam shrinkage and spectrum steepening is tested but disfavored.

79 ASTRONOMY AND ASTROPHYSICS↗

SDSS-IV MaNGA: calibration of astrophysical line-widths in the Hα region using HexPak observations

ABSTRACT We have re-observed $\rm \sim$40 low-inclination, star-forming galaxies from the MaNGA survey (σ ∼ 65 km s−1) at ∼6.5 times higher spectral resolution (σ ∼ 10 km s−1) using the HexPak integral field unit on the WIYN 3.5-m telescope. The aim of these observations is to calibrate MaNGA’s instrumental resolution and to characterize turbulence in the warm interstellar medium and ionized galactic outflows. Here we report the results for the Hα region observations as they pertain to the calibration of MaNGA’s spectral resolution. Remarkably, we find that the previously reported MaNGA line-spread-function (LSF) Gaussian width is systematically underestimated by only 1 per cent. The LSF increase modestly reduces the characteristic dispersion of H ii regions-dominated spectra sampled at 1–2 kpc spatial scales from 23 to 20 km s−1 in our sample, or a 25 per cent decrease in the random-motion kinetic energy. This commensurately lowers the dispersion zeropoint in the relation between line-width and star-formation rate surface-density in galaxies sampled on the same spatial scale. This modest zero-point shift does not appear to alter the power-law slope in the relation between line-width and star-formation rate surface-density. We also show that adopting a scheme whereby corrected line-widths are computed as the square root of the median of the difference in the squared measured line width and the squared LSF Gaussian avoids biases and allows for lower signal-to-noise data to be used reliably.

Chattopadhyay, Sabyasachi↗

Strain dependence of peak widths of reciprocal-and -space distribution functions of metalic glasses from in-situ x-ray scattering and molecular dynamics simulations.

We have examined the relationship between the variance in the atomic-level hydrostatic pressure, <{Delta}p{sup 2}>{sup 1/2}, and the widths of the first peaks in the reciprocal- and real-space distribution functions for elastically deformed metallic glasses. In situ synchrotron x-ray scattering studies performed on a binary Cu{sub 64.5}Zr{sub 35.5} glass subject to uniaxial loading reveal that the width of the first peak in the reduced-pair distribution function is dependent on the different elastic responses of the partial-pair correlations. Molecular dynamics (MD) simulations of the same binary glass, as well as a single-component glass, subject to hydrostatic deformation show that the widths of the first peaks in the partial-pair distribution functions are affected by length-scale-dependent changes in the relative atomic separation in the first nearest-neighbor shell. Moreover, the MD simulations show that the strain dependencies of the partial-pair peak widths do not necessarily match the strain-dependence of <{Delta}p{sup 2}>{sup 1/2}. The results suggest that the widths of the peaks in the reciprocal- and real-space functions are not solely dependent on <{Delta}p{sup 2}>{sup 1/2} but rather are also affected by the atomic rearrangements associated with elastic deformation.

36 MATERIALS SCIENCE↗

R-matrix and dynamical model calculations of three-body resonance decay widths

Calculations of the decay widths of three-body resonances are considered using both R-matrix and dynamical three-body theoretical models. The R-matrix approach, which treats the three-body decay as two, ordered two-body decays, has both simultaneous and sequential particle emission pathways, each with an associated decay width. The question of how these two widths should be combined to determine the total resonance width is considered using comparisons with the width deduced from fully dynamical three-body model calculations. We use the decay of the well-understood {sup 6}He(2{sup +}, 1.8 MeV) resonance (into {sup 4}He+n+n) as a benchmark case.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Scaling of the giant dipole resonance widths in hot rotating nuclei from the ground state values

The systematics of the giant dipole resonance (GDR) widths in hot and rotating nuclei are studied in terms of temperature T, angular momentum J, and mass A. The different experimental data in the temperature range of 1-2 MeV have been compared with the thermal shape fluctuation model (TSFM) in the liquid drop formalism using a modified approach to estimate the average values of T, J, and A in the decay of the compound nucleus. The values of the ground state GDR widths have been extracted from the TSFM parametrization in the liquid drop limit for the corrected T, J, and A for a given system and compared with the corresponding available systematics of the experimentally measured ground state GDR widths for a range of nuclei from A=45 to 194. Amazingly, the nature of the theoretically extracted ground state GDR widths matches remarkably well, though 1.5 times smaller, with the experimentally measured ground state GDR widths consistently over a wide range of nuclei.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Connection between asymptotic normalization coefficients and resonance widths of mirror states

Resonance widths are important characteristics of unstable nuclear states playing a crucial role in nuclear structure, nuclear reactions, and nuclear astrophysics. However, often it is difficult or impossible to determine the resonance widths from experiments, especially when required nuclei are unstable or the resonance widths are too small. In this paper, I suggest an indirect method of determination of resonance widths using transfer reactions populating bound states. From this reaction, one can extract the amplitudes of the tails of the bound-state wave functions. These amplitudes are called the asymptotic normalization coefficients (ANCs). The ANC method became one of the benchmarks of the Cyclotron Institute. Once the ANC is experimentally determined, one can find the resonance width of the mirror nuclei using the technique developed in this paper. Mirror nuclei are the ones in which the total number of nucleons is the same but the number of the protons of one of the nuclei is equal to the number of the neutrons of another nucleus. In this paper, 5 different examples of the application of the developed method are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Two-photon and one-photon-one-vector meson decay widths of the f{sub 0}(1370), f{sub 2}(1270), f{sub 0}(1710), f{sub 2}{sup '}(1525), and K{sub 2}*(1430)

We calculate the radiative decay widths, two-photon ({gamma}{gamma}) and one-photon-one-vector meson (V{gamma}), of the dynamically generated resonances from vector-meson-vector-meson interaction in a unitary approach based on the hidden-gauge Lagrangians. In the present paper we consider the following dynamically generated resonances: f{sub 0}(1370), f{sub 0}(1710), f{sub 2}(1270), f{sub 2}{sup '}(1525), K{sub 2}*(1430), two strangeness=0 and isospin=1 states, and two strangeness=1 and isospin=1/2 states. For the f{sub 0}(1370) and f{sub 2}(1270) we reproduce the previous results for the two-photon decay widths and further calculate their one-photon-one-vector decay widths. For the f{sub 0}(1710) and f{sub 2}{sup '}(1525) the calculated two-photon decay widths are found to be consistent with data. The {rho}{sup 0{gamma}}, {omega}{gamma} and {phi}{gamma} decay widths of the f{sub 0}(1370), f{sub 2}(1270), f{sub 0}(1710), f{sub 2}{sup '}(1525) are compared with the results predicted by other approaches. The K*{sup +{gamma}} and K*{sup 0{gamma}} decay rates of the K{sub 2}*(1430) are also calculated and compared with the results obtained in the framework of the covariant oscillator quark model. The results for the two states with strangeness=0, isospin=1 and two states with strangeness=1, isospin=1/2 are predictions that need to be tested by future experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Effect of MLC leaf width on treatment adaptation and accuracy for concurrent irradiation of prostate and pelvic lymph nodes

Purpose: The aim of the study was to evaluate the impact of multileaf collimator (MLC) leaf width on treatment adaptation and delivery accuracy for concurrent treatment of the prostate and pelvic lymph nodes with intensity modulated radiation therapy (IMRT). Methods: Seventy-five kilovoltage cone beam CTs (KV-CBCT) from six patients were included for this retrospective study. For each patient, three different IMRT plans were created based on a planning CT using three different MLC leaf widths of 2.5, 5, and 10 mm, respectively. For each CBCT, the prostate displacement was determined by a dual image registration. Adaptive plans were created by shifting selected MLC leaf pairs to compensate for daily prostate movements. To evaluate the impact of MLC leaf width on the adaptive plan for each daily CBCT, three MLC shifted plans were created using three different leaf widths of MLCs (a total of 225 adaptive treatment plans). Selective dosimetric endpoints for the tumor volumes and organs at risk (OARs) were evaluated for these adaptive plans. Using the planning CT from a selected patient, MLC shifted plans for three hypothetical longitudinal shifts of 2, 4, and 8 mm were delivered on the three linear accelerators to test the deliverability of the shifted plans and to compare the dose accuracy of the shifted plans with the original IMRT plans. Results: Adaptive plans from 2.5 and 5 mm MLCs had inadequate dose coverage to the prostate (D99 < 97%, or D{sub mean} < 99% of the planned dose) in 6%-8% of the fractions, while adaptive plans from 10 mm MLC led to inadequate dose coverage to the prostate in 25.3% of the fractions. The average V{sub 56Gy} of the prostate over the six patients was improved by 6.4% (1.6%-32.7%) and 5.8% (1.5%-35.7%) with adaptive plans from 2.5 and 5 mm MLCs, respectively, when compared with adaptive plans from 10 mm MLC. Pelvic lymph nodes were well covered for all MLC adaptive plans, as small differences were observed for D99, D{sub mean}, and V{sub 50.4Gy}. Similar OAR sparing could be achieved for the bladder and rectum with all three MLCs for treatment adaptation. The MLC shifted plans can be accurately delivered on all three linear accelerators with accuracy similar to their original IMRT plans, where gamma (3%/3 mm) passing rates were 99.6%, 93.0%, and 92.1% for 2.5, 5, and 10 mm MLCs, respectively. The percentages of pixels with dose differences between the measurement and calculation being less than 3% of the maximum dose were 85.9%, 82.5%, and 70.5% for the original IMRT plans from the three MLCs, respectively. Conclusions: Dosimetric advantages associated with smaller MLC leaves were observed in terms of the coverage to the prostate, when the treatment was adapted to account for daily prostate movement for concurrent irradiation of the prostate and pelvic lymph nodes. The benefit of switching the MLC from 10 to 5 mm was significant (p Much-Less-Than 0.01); however, switching the MLC from 5 to 2.5 mm would not gain significant (p= 0.15) improvement. IMRT plans with smaller MLC leaf widths achieved more accurate dose delivery.

61 RADIATION PROTECTION AND DOSIMETRY↗

TH-C-18A-05: Characteristics and Accuracy of CT Radiation Profile Width Measurements Using Radiochromic Films

Purpose: To investigate the impact of several acquisition and image analysis factors on the accuracy of CT beam width measurement using Gafchromic XR-QA2 film and an off the shelf document scanner. Methods: The film was carefully placed at the iso-center and exposed at various x-ray beam energies (80–140 kVp), exposure levels (50–400 mAs), and nominal beam widths (1.25, 5, and 10 mm). Films were scanned on a RICOH MP3501 flat-bed document scanner using reflection mode and various spatial resolutions (100 to 600 dpi) and locations within the scanner bed. Radiation dose profiles were derived by converting the net reflection measurements to dose values (in mGy) through film calibration (which is also described here). The beam widths were characterized by the FWHM and FWTM of the dose profiles and the deviations from the hybrid reference standards were quantified. The impact of x-ray beam energy, exposure intensity, film calibration, and the uniformity and spatial resolution of the document scanner were investigated. Results: The uncertainties in both FWHM and FWTM caused by varying beam energy, exposure level, and scanner uniformity were all within approximately 5%. Increasing scanner spatial resolution increased the uncertainty in both FWHM and FWTM (R2 = 0.35–0.71), with the FWTM affected by more than five times than the FWHM (28% vs. 4.9%). When uncalibrated dose profiles were used, the FWHM and FWTM were over-estimated by as much as 11.6% and 7.6%, respectively. Narrower beam width was more sensitive to the film calibration than the wider one (R2 = 0.68 and 0.85 for the FWHM and FWTM, respectively). Conclusion: Measurement of CT beam width using Gafchromic XR-QA2 films is robust against x-ray energy, exposure level, and scanner uniformity. It can provide adequate accuracy for all practical purposes with appropriate film calibration and scanner spatial resolution (100 dpi or less)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗