Search NASA⌕ Search

SEARCH · Search NASA

Results for “Wavefront control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Low Order Wavefront Sensing and Control for WFIRST-AFTA Coronagraph

To maintain the required WFIRST Coronagraph performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C use s the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading of the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST -AFTA Coronagraph. We will describe LOWFS/C's Zernike wavefront sensor concept and WFIRST LOWFS/C control design. We will present an overview of our analysis and modeling results on the Zernike wavefront sensor, the line -of-sight jitter suppression loop performance, as well as the low order wavefront error correction with the coronagraph's deformable mirror. In this paper we will also report the LOWFS/C testbed design and the preliminary in-air test results, which show a very promising performance of the Zernike wavefront sensor and FSM feedback loop.

exoplanets↗

Preliminary Jitter Stability Results for the Large UV/Optical/Infrared (LUVOIR) Surveyor Concept Using a Non-Contact Vibration Isolation and Precision Pointing System

The need for high payload dynamic stability and ultra-stable mechanical systems is an overarching technology need for large space telescopes such as the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor concept. The LUVOIR concept includes a 15-meter-diameter segmented-aperture telescope with a suite of serviceable instruments operating over a range of wavelengths between 100nm to 2.5 um. Wavefront error (WFE) stability of less than 10 picometers RMS of uncorrected system WFE per wavefront control step represents a drastic performance improvement over current space-based telescopes being fielded. Through the utilization of an isolation architecture that involves no mechanical contact between the telescope and the host spacecraft structure, a system design is realized that maximizes the telescope dynamic stability performance without driving stringent technology requirements on spacecraft structure, sensors or actuators. Through analysis of the LUVOIR finite element model and linear optical model, the wavefront error and Line-Of-Sight (LOS) jitter performance is discussed in this paper when using the Vibration Isolation and Precision Pointing System (VIPPS) being developed cooperatively with Lockheed Martin in addition to a multi-loop control architecture. The multi-loop control architecture consists of the spacecraft Attitude Control System (ACS), VIPPS, and a Fast Steering Mirror on the instrument. While the baseline attitude control device for LUVOIR is a set of Control Moment Gyroscopes (CMGs), Reaction Wheel Assembly (RWA) disturbance contribution to wavefront error stability and LOS stability are presented to give preliminary results in this paper. CMG disturbance will be explored in further work to be completed.

Sacks, Lia W.↗

OCCAMS: Optically Controlled and Corrected Active Meta-Material Space Structures

Telescopes require sub-wavelength figure (shape) error in order to achieve acceptable Strehl ratios. Traditional methods of achieving this require rigid and therefore heavy mirrors and reaction structures as well as proportionally heavy and expensive spacecraft busses and launch vehicles. This effectively limits the diameter and therefore resolution and collecting area of space optics. Large diameter telescopes must either be heavy or actively controlled. Space telescopes of the size proposed for missions such as TPF (Terrestrial Planet Finder), TPI (Terrestrial Planet Imager), etc. will likely require large active primaries and structures and corrective optics to implement downstream wavefront control. We propose a novel viable enabling technology. High resolution space imaging requires the production of lightweight large aperture optics subject to design tradespace constraints based on nanometer physical tolerances, low system aerial density, high control authority, suitable thermal and mechanical properties, deployment capability, launch vehicle volume constraints, as well as production cost and schedule risk mitigation. Segmented systems impose additional requirements on segment alignment, wavefront phasing, and telescope mass with increased edge diffraction. Photons weigh nothing. Why must even small space telescopes "weigh" tons? Our team is working to demonstrate that they do not, by leveraging 15 years of effort and a novel advanced concept.The ultimate research goal is to refine technology to produce a mission capable ultra-lightweight membrane optic whose shape can be remotely controlled using a laser beam. Using our novel optically-controlled molecular actuators allows substitution of optically-induced control for rigidity and mirror mass. In analogy with noise-canceling headphones, this technique also potentially provides a way to excite vibratory modes to couple with and damp out normal modes of oscillation induced by slewing, other motion and thermal changes, thus allowing a robust response to repointing of a large aperture.

Astronomy↗

HCIT Broadband Contrast Performance Sensitivity Studies

One of the important milestones of the TPF Coronagraph project is to demonstrate the ability to predict the performance sensitivities of the system at levels consistent with exo-planet detection requirement. We want to gain some general understanding about the potentials and the limitations of the current single-Deformable-Mirror (DM) High-contrast imaging testbed (HCIT) system through modeling and simulations. Specifically, we want to understand the effects of some common errors on the EFC-based control of e-field over a half dark-hole region and broadband contrast. Investigated errors include: (1) Absorbing particles on a flat-mirror (2) Defects on the Occulter surface (3) Dead actuators on the DM. We also investigated the effects of control bandwidth on the broadband contrast. We used a MACOS-based simulation algorithm which (1) combines a ray trace, diffraction model, & a broadband wavefront control algorithm (2) is capable of performing full three-dimensional near-field diffraction analysis

exoplanets↗

Low Order Wavefront Sensing and Control for WFIRST Coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

wavefront sensing and control↗

The Potential of Small Space Telescopes for Exoplanet Observations

The imaging of faint exoplanets near bright stars requires the development of very high contrast detection techniques, including both precise wavefront control and deep starlight rejection. A system-level proof-of-principle experiment carried out at at the Palomar Observatory has recently demonstrated that exoplanets can be detected very near stars even with a fairly small (1.5 m diameter) telescope aperture, such as someday might be used by a first space-based exoplanet imaging mission. Using fine-scale wavefront correction across this small aperture, together with fine pointing and focus control, pre- and post-detection speckle reduction, and a vector vortex coronagraph, it has been possible to achieve extremely good starlight rejection within a small number of diffractions beams of the stellar position. This performance has recently allowed the imaging of the three HR8799 planets and the HD32297 disk, thus providing a first system-level validation of the steps needed to achieve high-contrast observations at very small angles. These results thus serve to highlight the potential of small space telescopes aiming at high-contrast exoplanet observations. Specifically, a small-angle coronagraph enables the use of smaller telescopes, thus potentially reducing mission cost significantly.

coronagraphy↗

Wavefront Sensing and Control Technology for Submillimeter and Far-Infrared Space Telescopes

The NGST wavefront sensing and control system will be developed to TRL6 over the next few years, including testing in a cryogenic vacuum environment with traceable hardware. Doing this in the far-infrared and submillimeter is probably easier, as some aspects of the problem scale with wavelength, and the telescope is likely to have a more stable environment; however, detectors may present small complications. Since this is a new system approach, it warrants a new look. For instance, a large space telescope based on the DART membrane mirror design requires a new actuation approach. Other mirror and actuation technologies may prove useful as well.

Redding, Dave↗

Maturing Electron Multiplying Charge Coupled Device Photon-Counting with Variable Multiplication Gain Imaging for a Coronagraphic Instrument

This is an introduction to a US Government Program that conducted high-contrast imaging experiments with an Electron Multiplying Charge Coupled Device (EMCCD) in an interferometric coronagraph. This report will introduce the concepts of “Charge Blooming” and “Starlight Saturation” in the context of high-contrast astronomical imaging. These phenomena adversely affect the performance of high-contrast photon-counting instruments that do not use a mask to physically block starlight in the science channel of the coronagraph. The problems will be presented with the help of images taken with a commercial EMCCD camera in the Visible Nulling Coronagraph at the Goddard Space Flight Center (GSFC). A new clocking scheme for EMCCDs – Variable Multiplication Gain Clocking – will be proposed as a means for suppressing horizontal blooming and starlight saturation in an astronomical camera. This opening report from the program will conclude with an introduction to a new controller for high-contrast imaging with EMCCDs in coronagraphs. This controller is being designed to allow a single frame from an EMCCD to be scanned in multiple modes – photon counting and digitization – to enable direct imaging of an exo-planet and wavefront control of a coronagraph, simultaneously.

Udayan Mallik↗

Low order wavefront sensing and control for WFIRST coronagraph

To maintain the required WFIRST Coronagraph starlight suppression performance in a realistic space environment, a low order wavefront sensing and control (LOWFS/C) subsystem is necessary. The LOWFS/C uses the rejected stellar light from coronagraph to sense and suppress the telescope pointing drift and jitter as well as the low order wavefront errors due to changes in thermal loading on the telescope and the rest of the observatory. In this paper we will present an overview of the low order wavefront sensing and control subsystem for the WFIRST Coronagraph and describe the WFIRST Coronagraph LOWFS function, its design, and modeled performance. We will present experimental results on a dedicated LOWFS/C testbed that show that the LOWFS/C subsystem not only can sense pointing errors better than 0.2 mas but has also experimentally demonstrated closed loop pointing error suppression with residuals better than 0.4 mas rms per axis for the vast majority of observatory reaction wheel speeds.

Wilson, Dan↗

Terahertz focusing of multiple wavelengths by graphene metasurfaces

Metasurfaces can achieve nearly arbitrary wavefront control based on manipulation of the wave phase profile. We propose a metasurface based on double graphene cut-wire resonators which can cover the complete 2π phase region with high reflection efficiency. This full phase coverage is essential for efficient wavefront manipulation, without reflecting energy into unwanted channels. A mirror capable of focusing multiple wavelengths is demonstrated numerically based on the proposed structure. The mirror can effectively focus terahertz (THz) waves from 1.2 to 1.9 THz to the same focal point by changing the Fermi level of each graphene resonator separately. The presented metasurface could provide a powerful platform for controlling THz waves, including focusing, beam steering, beam shaping, and holography.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exo-C: A Dedicated Probe-scale Space Mission for Coronagraphic Imaging and Spectroscopy of Exoplanetary Systems

"Exo-C", the Exoplanet Coronagraph, is a concept for a dedicated probe-scale (< $1B) space mission optimized for direct imaging of exoplanetary systems. It was the product of a detailed mission study carried in 2013-2015 under the sponsorship of the NASA Astrophysics Division. Exo-C was designed to be capable of spectrally characterizing 1-2 dozen nearby exoplanets in reflected visible light, discovering previously undetected planets, and imaging structure in hundreds of circumstellar disks. It would obtain unique science results on planets down to super-Earth size and serve as a technology pathfinder toward an eventual flagship-class mission to find and characterize habitable Earth-like exoplanets. Key design elements are an unobscured telescope aperture, an internal coronagraph with deformable mirrors for precise wavefront control, and an orbit and observatory design chosen for high thermal stability. ExoC’s telescope aperture, orbit, mission lifetime, and spacecraft bus are all comparable to those of the highly successful Kepler mission. Much of the needed technology development (precision pointing, wavefront sensing and correction, high contrast integral field spectroscopy, detector flight readiness) has been advanced by the WFIRST Coronagraph Instrument (CGI) project over the past several years. Mission performance, mass, power, and cost estimates have also benefited from detailed work by the WFIRST CGI team. A Cost and Technical Evaluation (CATE) was performed in 2015 by the Aerospace Corporation. Today Exo-C is a backup option to WFIRST CGI. It could nominally be implemented within seven years from project start. This white paper summarizes the study final report, with updates on performance and technical readiness as of spring 2019.

Karl R. Stapelfeldt↗

The Parabolic Deformable Mirror Testbed at NASA Goddard Space Flight Center

One of the primary goals of future coronagraph space missions is to spectrally characterize Earth-like exoplanets. Observing efficiency is critical and directly related to how large of a field of view we can correct and the bandwidth of that correction. In addition to the coronagraph itself, the bandwidth and depth of contrast is related to the wavefront control system, which classically uses two deformable mirrors (DMs) in series. The minimum distance between these DMs is determined by the Talbot distance of the beam, meaning it scales as the square of the beam size. NASA Goddard is exploring an alternative design architecture to the two-DM approach in which the reimaging optics for the coronagraph are also deformable and we only retain a high-order pupil DM. With these off-axis parabolic elements being made deformable, the long propagation distance between the two DMs is eliminated. Goddard has procured an off-axis parabolic DM (PDM or OAP DM) from vendor ALPAO, France. A testbed is currently being built to test the PDM and demonstrate its utility for achieving high contrast in a coronagraph. The testbed is also being built with an integrated low-order wavefront sensing capability, allowing for integrated testing of a dynamic environment with multiple estimation and control loops.

Hari Subedi↗

Dynamic Testbed Demonstration of WFIRST Coronagraph Low Order Wavefront Sensing and Control (LOWFS/C)

To maintain the required performance of WFIRST Coronagraph in a realistic space environment, a Low Order Wavefront Sensing and Control (LOWFS/C) subsystem is necessary. The LOWFS/C uses a Zernike wavefront sensor (ZWFS) with the phase shifting disk combined with the starlight rejecting occulting mask. For wavefront error corrections, WFIRST LOWFS/C uses a fast steering mirror (FSM) for line-of-sight (LoS) correction, a focusing mirror for focus drift correction, and one of the two deformable mirrors (DM) for other low order wavefront error (WFE) correction. As a part of technology development and demonstration for WFIRST Coronagraph, a dedicated Occulting Mask Coronagraph (OMC) testbed has been built and commissioned. With its configuration similar to the WFIRST flight coronagraph instrument the OMC testbed consists of two coronagraph modes, Shaped Pupil Coronagraph (SPC) and Hybrid Lyot Coronagraph (HLC), a low order wavefront sensor (LOWFS), and an optical telescope assembly (OTA) simulator which can generate realistic LoS drift and jitter as well as low order wavefront error that would be induced by the WFIRST telescope’s vibration and thermal changes. In this paper, we will introduce the concept of WFIRST LOWFS/C, describe the OMC testbed, and present the testbed results of LOWFS sensor performance. We will also present our recent results from the dynamic coronagraph tests in which we have demonstrated of using LOWFS/C to maintain the coronagraph contrast with the presence of WFIRST-like line-of-sight and low order wavefront disturbances.

Zhou, Hanying↗

Micromachined, Electrostatically Deformable Reflectors

Micromachined, closed-loop, electrostatically actuated reflectors (microCLEARs) provide relatively simple and inexpensive alternatives to large, complex, expensive adaptive optics used to control wavefronts of beams of light in astronomy and in experimental laser weapons. Micromachining used to make deformable mirror, supporting structure, and actuation circuitry. Development of microCLEARs may not only overcome some of disadvantages and limitations of older adaptive optics but may also satisfy demands of potential market for small, inexpensive deformable mirrors in electronically controlled film cameras, video cameras, and other commercial optoelectronic instruments.

Bartman, Randall K.↗

Design and Modeling of the Off-Axis Parabolic Deformable (OPD) Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Subedi, Hari↗

Design and Modeling of the Off-Axis Parabolic Deformable Mirror Laboratory

Coronagraph-equipped direct imaging missions need an active wavefront control system to cancel out the optical aberrations that degrade the performance of the coronagraphs. A fast steering mirror is used to control Line-of-Sight (LoS) pointing error caused by the telescope jitter. In addition to controlling other low-order aberrations such as astigmatism and coma, high stroke, high actuator density deformable mirrors (DMs) are also used to control the electric field at the required high spatial frequencies. We are designing a testbed to verify a different deformable architecture, where the powered optic in the optical train are controllable and have lower actuator count compared to the existing DMs with flat nominal surfaces. This simplifies the packaging issue for space missions and reduces both cost and risk of having the entire coronagraph instrument's performance depending on one or two high-actuator count DMs. The testbed would also be capable of testing different low-order wavefront sensing algorithms, which focuses in the near-term on a new adaptive Kalman filtering and gradient decent method to estimate the harmonic LoS errors that affect space telescopes. In long run, we would test different machine learning techniques to estimate low-order aberrations and non-linear algorithms for digging the region of high contrast called the dark holes (DH).

Communication↗

NASA Tech Briefs, March 2010

Topics covered include: Software Tool Integrating Data Flow Diagrams and Petri Nets; Adaptive Nulling for Interferometric Detection of Planets; Reducing the Volume of NASA Earth-Science Data; Reception of Multiple Telemetry Signals via One Dish Antenna; Space-Qualified Traveling-Wave Tube; Smart Power Supply for Battery-Powered Systems; Parallel Processing of Broad-Band PPM Signals; Inexpensive Implementation of Many Strain Gauges; Constant-Differential-Pressure Two-Fluid Accumulator; Inflatable Tubular Structures Rigidized with Foams; Power Generator with Thermo-Differential Modules; Mechanical Extraction of Power From Ocean Currents and Tides; Nitrous Oxide/Paraffin Hybrid Rocket Engines; Optimized Li-Ion Electrolytes Containing Fluorinated Ester Co-Solvents; Probabilistic Multi-Factor Interaction Model for Complex Material Behavior; Foldable Instrumented Bits for Ultrasonic/Sonic Penetrators; Compact Rare Earth Emitter Hollow Cathode; High-Precision Shape Control of In-Space Deployable Large Membrane/Thin-Shell Reflectors; Rapid Active Sampling Package; Miniature Lightweight Ion Pump; Cryogenic Transport of High-Pressure-System Recharge Gas; Water-Vapor Raman Lidar System Reaches Higher Altitude; Compact Ku-Band T/R Module for High-Resolution Radar Imaging of Cold Land Processes; Wide-Field-of-View, High-Resolution, Stereoscopic Imager; Electrical Capacitance Volume Tomography with High-Contrast Dielectrics; Wavefront Control and Image Restoration with Less Computing; Polarization Imaging Apparatus; Stereoscopic Machine-Vision System Using Projected Circles; Metal Vapor Arcing Risk Assessment Tool; Performance Bounds on Two Concatenated, Interleaved Codes; Parameterizing Coefficients of a POD-Based Dynamical System; Confidence-Based Feature Acquisition; Algorithm for Lossless Compression of Calibrated Hyperspectral Imagery; Universal Decoder for PPM of any Order; Algorithm for Stabilizing a POD-Based Dynamical System; Mission Reliability Estimation for Repairable Robot Teams; Processing AIRS Scientific Data Through Level 3; Web-Based Requesting and Scheduling Use of Facilities; AutoGen Version 5.0; Time-Tag Generation Script; PPM Receiver Implemented in Software; Tropospheric Emission Spectrometer Product File Readers; Reporting Differences Between Spacecraft Sequence Files; Coordinating "Execute" Data for ISS and Space Shuttle; Database for Safety-Oriented Tracking of Chemicals; Apparatus for Cold, Pressurized Biogeochemical Experiments; Growing B Lymphocytes in a Three-Dimensional Culture System; Tissue-like 3D Assemblies of Human Broncho-Epithelial Cells; Isolation of Resistance-Bearing Microorganisms; Oscillating Cell Culture Bioreactor; and Liquid Cooling/Warming Garment.

Source record↗