Search NASA⌕ Search

SEARCH · Search NASA

Results for “X ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Calcium is associated with specific soil organic carbon decomposition products at Blodgett Forest Research Center, Georgetown, California as analysed with scanning transmission X-ray microscopy carbon near-edge X-ray absorption fine structure spectroscopy

This data is from the paper calcium is associated with specific soil organic carbon decomposition products, published in SOIL. DOI: https://doi.org/10.5194/soil-11-381-2025, 2025.This file contains CSVs with spectral data and bulk soil data and there is no specific program required to open this data. The data includes Scanning transmission X-ray microscopy carbon near-edge X-ray absorption fine structure spectroscopy. data from the measurement of samples from the Whole-soil Warming project, run by the Belowground Biogeochemistry team at Blodgett Forest Research Center, Georgetown, California run by the University of California, Berkeley. It also includes bulk soil chemical properties. The University of California's Blodgett Forest Research Station (Forest) is situated in the Sierra Nevada foothills (1370 m a.s.l.) near Georgetown, California. The samples were collected from here: 38.912013, -120.661469, https://maps.app.goo.gl/291bCJ1zVqUhgktz6. The Forest soils were characterised as Alfisols, which are equivalent to Dystric Cambisols (IUSS Working Group WRB, 2015), and formed in granitic parent materials, in a temperate climate, under thinned, mixed-coniferous forest (Fig. S3; Gaudinski et al., 2009). With these analyses we aimed to answer the question, is calcium associated with a specific type of organic matter enriched in aromatic and phenolic carbon at the microscale in samples from Blodgett Forest Research Center? and how does this specific type of carbon respond to experiments targetted at removing and adding calcium to the soils, specifically cation exchange and incubation after calcium addition? Abstract from the paper can be found below: Calcium (Ca) may contribute to the preservation of soil organic carbon (SOC) in more ecosystems than previously thought. Here we provide evidence that Ca is co-located with SOC compounds that are enriched in aromatic and phenolic groups, across different acidic soil-types and locations with different ecosystem properties, differing in terms of climate, parent material, soil type, and vegetation. In turn, this co-localised fraction of Ca-SOC is removed through cation-exchange, and the association is then only re-established during decomposition in the presence of Ca (Ca addition incubation). Thus, highlighting a causative link between decomposition and the co-location of Ca with a characteristic fraction of SOC. Decomposition increases the relative proportion of negatively charged functional groups, which can increase the propensity for the association between SOC and Ca, and in turn, this association inhibits dissolved organic carbon export or further decomposition. We propose that this mechanism could be driven by Ca hotspots on the microscale shifting local decomposition processes and thereby explaining the colocation of Ca with SOC of a specific composition across different acidic soil environments. Incorporating this biogeochemical process into Earth System Models could improve our understanding, predictions, and management of carbon dynamics in soils, and account for their response to Ca-rich amendments.

54 ENVIRONMENTAL SCIENCES↗

Microscopy X-ray imaging enriched with small angle X-ray scattering for few nanometer resolution reveals shock waves and compression in intense short pulse laser irradiation of solids

Understanding how laser pulses compress solids into high-energy-density states requires diagnostics that simultaneously resolve macroscopic geometry and nanometer-scale structure. Here we present a combined X-ray imaging (XRM) and small-angle X-ray scattering (SAXS) approach that bridges this diagnostic gap. Using the Matter in Extreme Conditions end station at LCLS, we irradiated 25 μm copper wires with 45 fs, 0.9 J, 800 nm pulses at 3.5 × 10 19 W/cm 2 while probing with 8.2 keV XFEL pulses. XRM visualizes the evolution of ablation, compression, and inward-propagating fronts with ∼ 200 nm resolution, while SAXS quantifies their nanometer-scale sharpness via the time-resolved evolution of scattering streaks. The joint analysis reveals that an initially smooth compression steepens into a nanometer-sharp shock front after t sh ≈ (18 ± 3) ps, consistent with an analytical steepening model and hydrodynamic simulations. The front reaches a velocity of c sh ≈ 25 k m / s and a lateral width of several tens of microns, demonstrating direct observation of shock formation and decay at solid density for the first time with few-nanometer precision. This integrated XRM–SAXS method establishes a quantitative, multi-scale diagnostic of laser-driven shocks in dense plasmas relevant to inertial confinement fusion, warm dense matter, and planetary physics.

Kluge, Thomas [Helmholtz-Zentrum Dresden-Rossendor↗

X-ray emission of the radio-loud quasar SDSS J121426.52+140258.9: independent variations between optical/UV and X-ray emission

To understand the X-ray emission of active galactic nuclei (AGNs), we explored the optical-to-X-ray variation correlation of a radio-loud quasar (RLQ) SDSS J121426.52+140258.9 (hereafter J1214+1402) with multi-epoch observations by the Swift and XMM–Newton telescopes. With the historical multiband data, we found that the infrared-to-X-ray flux of RLQ J1214+1402 should not be dominated by the beamed-jet emission. The Swift optical/UV and X-ray light curves showed that J1214+1402 has two optical states, with low flux before 2014 April 8 and high flux after 2014 June 11, but has no significant X-ray variations during the time range between 2007 March 9 and 2014 August 4. This result was supported by the XMM–Newton observations in the time overlapping with Swift. Interestingly, the early XMM–Newton data prior to the Swift time present two unusual emission epochs when J1214+1402 has relatively low optical fluxes but has the brightest X-ray fluxes. The overall independence of optical-to-X-ray variation seems hard to describe by the disc–corona model. With the X-ray spectral fitting, we find that the soft X-ray excess in J1214+1402 appears only during the high optical state when the X-ray emission is at a low state. The soft X-ray excess in J1214+1402 is difficult to explain by an ionized accretion disc; instead, it may be related to the warm corona.

79 ASTRONOMY AND ASTROPHYSICS↗

X-ray atomic mapping of quantum dots

We report a model-independent atomic-mapping technique for quantum dots (QDs) by combining Bragg reflection x-ray standing wave (XSW) and grazing incidence diffraction (GID) measurements. In this study, we choose GaAs capped InGaAs QDs/GaAs(001) as a model system to show the locations and arrangements of indium atoms within the QDs along various [hkl] directions. This technique directly reveals the actual amount of positional anisotropy and ordering fraction of indium atoms within the QDs by probing the (1¯11), (111), (311), (1¯31), (113), and (1¯13) crystallographic planes. We find that indium atoms are outwardly shifted along the [001] direction by small fractions of the lattice constant, 0.04a GaAs and 0.06a GaAs from Ga sites for 50- and 150-Å GaAs capped InGaAs QDs, respectively. We observe that an improved coherency factor of the indium atoms within the QDs by 45–60% along the [001] and [011] directions reduces the photoluminescence linewidth by 22%, thus making the QDs efficient for QD-laser and optoelectronic device applications. Here, we also find that the position and ordering of In atoms along the (113) and (1¯13) planes are most sensitive to the thickness of the GaAs cap layer. Our XSW-based results are supported by numerical calculations using a QD-macroscopic structural model based on our GID study. We thus show that this atomic-mapping technique will be useful for studying various quantum structures and tuning their properties.

36 MATERIALS SCIENCE↗

The AUREX cell: a versatile operando electrochemical cell for studying catalytic materials using X-ray diffraction, total scattering and X-ray absorption spectroscopy under working conditions

Understanding the structure–property relationship in electrocatalysts under working conditions is crucial for the rational design of novel and improved catalytic materials. This paper presents the Aarhus University reactor for electrochemical studies using X-rays (AUREX) operando electrocatalytic flow cell, designed as an easy-to-use versatile setup with a minimal background contribution and a uniform flow field to limit concentration polarization and handle gas formation. The cell has been employed to measure operando total scattering, diffraction and absorption spectroscopy as well as simultaneous combinations thereof on a commercial silver electrocatalyst for proof of concept. This combination of operando techniques allows for monitoring of the short-, medium- and long-range structure under working conditions, including an applied potential, liquid electrolyte and local reaction environment. The structural transformations of the Ag electrocatalyst are monitored with non-negative matrix factorization, linear combination analysis, the Pearson correlation coefficient matrix, and refinements in both real and reciprocal space. Upon application of an oxidative potential in an Ar-saturated aqueous 0.1 M KHCO 3 /K 2 CO 3 electrolyte, the face-centered cubic (f.c.c.) Ag gradually transforms first to a trigonal Ag 2 CO 3 phase, followed by the formation of a monoclinic Ag 2 CO 3 phase. A reducing potential immediately reverts the structure to the Ag (f.c.c.) phase. Following the electrochemical-reaction-induced phase transitions is of fundamental interest and necessary for understanding and improving the stability of electrocatalysts, and the operando cell proves a versatile setup for probing this. In addition, it is demonstrated that, when studying electrochemical reactions, a high energy or short exposure time is needed to circumvent beam-induced effects.

Frank, Sara (ORCID:0000000163218363)↗

A variable X-ray chopper system for phase-sensitive detection in synchrotron X-ray scanning tunneling microscopy

An ultra-high-vacuum compatible X-ray chopper system has been designed, constructed and integrated into the XTIP beamline at the Advanced Photon Source at Argonne National Laboratory. The XTIP beamline can operate at soft X-ray energies from 400 eV to 1900 eV while providing a focused beam down to about 10 µm × 10 µm into the synchrotron X-ray scanning tunneling microscopy (SX-STM) endstation instrument. The X-ray chopper is a critical component for separating topographic information from chemical information in SX-STM through phase-sensitive current detection. Depending on the experimental needs, the modulation frequency can be controlled from 100 Hz to 10 kHz. In addition, the chopper system is fully bakeable and can achieve a base pressure of 10 -10 mbar. Facilities for active water cooling have been designed, but passive cooling through copper braids has been shown to be sufficient at standard chopping frequencies. Using an Fe/Al 2 O 3 /CoAl(111) sample, the separation of the SX-STM current into a chemical component and a stable feedback signal is demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a Pixelated Cadmium Telluride Detector System Using a Polychromatic X-Ray Source and Gold Nanoparticle-Loaded Phantoms for Benchtop X-Ray Fluorescence Imaging

In this paper, the imaging dose and scan time have been considered as the two major constraints for routine benchtop x-ray fluorescence computed tomography (XFCT) imaging. One way to address this issue is to acquire x-ray fluorescence (XRF) signals in parallel through a 2D array of single-crystal detectors or a pixelated detector along with the cone-beam x-ray source. To identify a detector system suitable for this purpose, a commercially available, fully spectroscopic cadmium telluride (CdTe) pixelated detector, HEXITEC (High-Energy X-ray Imaging Technology), was tested under the experimental conditions optimized for benchtop XFCT imaging of gold nanoparticles (GNPs). Specifically, two different parallel-hole stainless steel collimators were fabricated and coupled with the detector for seamless integration into our existing benchtop cone-beam XFCT system. After the detector deployment, this benchtop XFCT system was used to detect XRF photons from GNP-loaded phantoms. A pixel-merging algorithm was introduced to enhance the sensitivity of XRF photon detection thereby minimizing the scan time. The effect of pixel-level charge sharing correction algorithms was investigated within the context of benchtop XFCT imaging. The detector energy resolution, in terms of the full width at half maximum (FWHM) values at different gold K-shell XRF energies, was also determined. Of the two charge sharing correction algorithms examined, the charge sharing addition gave better sensitivity than the charge sharing discrimination (csd). On the other hand, under the current experimental conditions, the energy resolution of the HEXITEC detector was the best with the csd and estimated to be 1.56 keV FWHM at 66-69 keV photon energy. Overall, despite some degradation of the detector energy resolution (compared with typical single crystal CdTe detectors), the HEXITEC detector enabled parallel data acquisition under the experimental conditions typical of benchtop XFCT imaging and operated well within our benchtop XFCT setup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The X-Ray Luminosity Function Evolution of Quasars and the Correlation between the X-Ray and Ultraviolet Luminosities

We explore the evolution of the X-ray luminosity function of quasars and the intrinsic correlation between the X-ray and 2500 Å ultraviolet luminosities, utilizing techniques verified in previous works and a sample of over 4000 quasars detected with Chandra and XMM-Newton in the range 0 < z < 5. We find that quasars have undergone significantly less evolution with redshift in their total X-ray luminosity than in other wave bands. We then determine that the best-fit intrinsic power-law correlation between the X-ray and ultraviolet luminosities, of the form ${L}_{{\rm{X}}}^{{\prime} }\propto {({L}_{\mathrm{UV}}^{{\prime} })}^{\gamma }$, is γ = 0.28 ± 0.03, and we derive the luminosity function and density evolution in the X-ray band. We discuss the implications of these results for models of quasar systems.

79 ASTRONOMY AND ASTROPHYSICS↗

XRISM high-resolution X-ray spectroscopy of Cygnus X-1: Highly ionized iron absorption structures

We present the first high-resolution X-ray spectral analysis of Cygnus X-1 using XRISM. The observation wa3s carried out from 2024 April 7 to 10, covering the orbital phase range 0.65–0.17 during its low/hard state. Taking advantage of the exceptional energy resolution of the Resolve instrument, we examined highly ionized iron absorption lines and characterized the ionization states, column densities, and line-of-sight velocities of the absorbing plasma. Spectral analysis revealed an ionization parameter of $\xi \sim 3$, column densities of a few $\times 10^{21}$ cm$^{-2}$, and a blueshifted velocity of $\sim$100 km s$^{-1}$. The observation was divided into two phases: before and after orbital phase $\phi _{\rm {orb}} = 0.9$, corresponding to non-dipping and dipping intervals. While only weak absorption features were present before $\phi _{\rm {orb}} = 0.9$, strong absorption by He-like and H-like Fe appeared during the dipping phase. We measured equivalent widths of 2.3, 0.4, and 1.2 eV for He-like Fe K$\alpha$ and H-like Ly$\alpha _1$ and Ly$\alpha _2$, respectively—demonstrating the capability of XRISM Resolve to securely detect narrow absorption features of only a few eV. These measurements trace the motion of the absorbing material and offer insight into the kinematics and spatial distribution of the wind in the vicinity of the black hole. These findings enhance our understanding of wind-fed accretion in Cygnus X-1 and highlight the importance of continued high-resolution X-ray observations to further constrain the physical properties of winds and accretion flows in high-mass X-ray binaries.

Astronomy and AstroPhysics↗

Dark-field x-ray microscopy for 2D and 3D imaging of microstructural dynamics at the European x-ray free-electron laser

Dark field x-ray microscopy (DXFM) can visualize microstructural distortions in bulk crystals. Using the femtosecond x-ray pulses generated by x-ray free-electron lasers (XFELs), DFXM can achieve sub-μm spatial resolution and <100 fs time resolution simultaneously. In this paper, we demonstrate ultrafast DFXM measurements at the European XFEL to visualize an optically driven longitudinal strain wave propagating through a diamond single crystal. We also present two DFXM scanning modalities that are new to the XFEL sources: spatial 3D and 2D axial-strain scans with sub-μm spatial resolution. With this progress in XFEL-based DFXM, we discuss new opportunities to study multi-timescale spatiotemporal dynamics of microstructures.

47 OTHER INSTRUMENTATION↗

Analysis of X-ray images and spectra (aXis2000): A toolkit for the analysis of X-ray spectromicroscopy data

Spectromicroscopy refers to analytical methods that combine imaging and spectroscopy to provide detailed, spatially resolved analytical information about a sample, such as the type and quantitative spatial distributions of chemical components, geometric or magnetic alignment information, crystal structure, etc. The analysis of X-ray images and spectra (aXis2000) software described in this work provides a set of routines within a single, integrated, graphical-oriented package to read, display, manipulate and analyze spectromicroscopy data, with particular focus on soft X-ray spectromicroscopy methods such as scanning transmission X-ray microscopy (STXM), X-ray photoemission electron microscopy (XPEEM), scanning photoelectron X-ray microscopy (SPEM) and transmission X-ray microscopy (TXM). Here, this free software is described and compared to other software that can provide similar or complementary capabilities. Examples of spectromicroscopic analyses using advanced features of aXis2000 are provided.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resonant X-ray emission spectroscopy from broadband stochastic pulses at an X-ray free electron laser

Abstract Hard X-ray spectroscopy is an element specific probe of electronic state, but signals are weak and require intense light to study low concentration samples. Free electron laser facilities offer the highest intensity X-rays of any available light source. The light produced at such facilities is stochastic, with spikey, broadband spectra that change drastically from shot to shot. Here, using aqueous ferrocyanide, we show that the resonant X-ray emission (RXES) spectrum can be inferred by correlating for each shot the fluorescence intensity from the sample with spectra of the fluctuating, self-amplified spontaneous emission (SASE) source. We obtain resolved narrow and chemically rich information in core-to-valence transitions of the pre-edge region at the Fe K-edge. Our approach avoids monochromatization, provides higher photon flux to the sample, and allows non-resonant signals like elastic scattering to be simultaneously recorded. The spectra obtained match well with spectra measured using a monochromator. We also show that inaccurate measurements of the stochastic light spectra reduce the measurement efficiency of our approach.

Fuller, Franklin D. (ORCID:0000000237737087)↗

Operando X-Ray Diffraction During High Temperature Electrolysis

This work presents the design, development, and deployment of an operando X-ray diffraction (XRD) system for high-temperature electrolysis (HTE), enabling real-time characterization of solid oxide electrolysis cells (SOECs) under true operational conditions. The integration of an HTE test stand within a synchrotron radiation environment, mimicking the conditions of a laboratory setup, aims to enhance our understanding of the degradation processes affecting the performance and longevity of SOECs. Utilizing a custom furnace and a high precision motor stack assembly at the Stanford Synchrotron Radiation Lightsource (SSRL), the system revealed unparalleled insights into the structural evolution of SOEC components through various operational stages, including initial heat ramp, cell reduction, fuel ramp, and wet electrolysis. Initial results demonstrate the significant impact of the initial heating and cooling on secondary phase formation within the SOEC, highlighting the utility of operando XRD for developing more efficient and durable hydrogen production technologies.

08 HYDROGEN↗

Path-Integrated X-Ray Images for Multi-Surface Digital Image Correlation (PI-DIC)

X-ray imaging offers unique possibilities for Digital Image Correlation (DIC), opening the door for full-field deformation measurements of a test article in complex environments where optical DIC suffers severe biases or is impossible. While X-ray DIC has been performed in the past with standard DIC codes designed for optical images, the path-integrated nature of X-ray images places constraints on the experimental setup, predominantly that only a single surface of interest moves/deforms. These requirements are difficult to realize for many practical situations and limit the amount of information that can be garnered in a single test. Other X-ray based diagnostics such as Digital Volume Correlation (DVC) and Projection DVC (P-DVC) overcome these obstacles, but DVC is limited to quasi-static tests, and both DVC and P-DVC necessitate high-resolution computed tomography (CT) scan(s) and often require a potentially invasive pattern throughout the volume of the specimen. Here this work presents a novel approach to measure time-resolved displacements and strains on multiple surfaces from a single series of 2D, path-integrated (PI) X-ray images, called PI-DIC. The principle of optical flow or conservation of intensity—the foundation of DIC—was reframed for path-integrated images, for an exemplar setup comprised of two plates moving and deforming independently. Synthetic images were generated for rigid translations, rigid rotations, and uniform stretches, where each plate underwent a unique motion/deformation. Experimental specimens were fabricated (either an aluminum plate with tantalum features or a plastic plate with steel features) and the two specimens were independently translated. PI-DIC was successfully demonstrated with the synthetic images and validated with the experimental images. Prescribed displacements were recovered for each plate from the single set of path-integrated, deformed images. Errors were approximately 0.02 px for the synthetic images with 1.5% image noise, and 0.05 px for the experimental images. These results provide the foundation for PI-DIC to measure motion and deformation of multiple, independent surfaces with subpixel accuracy from a single series of path-integrated X-ray images.

47 OTHER INSTRUMENTATION↗

Surface analysis insight note: X‐ray photoelectron spectroscopy analysis of battery electrodes—Challenges with nickel–manganese–cobalt and Li examples using an Al Kα x‐ray source

X‐ray photoelectron spectroscopy (XPS) has become a highly important tool for the analysis of battery materials and components. However, both anecdotal and detailed analysis of selected parts of the literature indicate that many reports of XPS on battery electrodes have significant analysis or data flaws. In this paper, we highlight several of the common challenges that analysts face when using XPS for battery materials, pointing to recent literature that addresses many of the critical issues associated with sample preparation as well as data collection and analysis. A common error for battery materials (and other materials) involves ignoring peak overlaps and interferences. Specifically, when a “minor” peak associated with a component in relatively high concentration overlaps or contributes to the primary peak (or one recommended for quantitative analysis) from a different element in the material. Overlap issues apply to many battery electrodes composed of many elements with complex photoelectron peak structures, as well as those involving peaks with seemingly simpler spectral envelopes such as Li and F. Examples of issues associated with battery systems are highlighted by a discussion of challenges associated with XPS analysis of Li and nickel–manganese–cobalt (NMC) electrodes in battery systems. Lithium analysis has challenges associated with the preparation and an often‐unrecognized peak overlap with F. In our laboratory and in the literature, NMC electrodes are often examined and new XPS users do not always recognize interference of the Auger signal from F KLL (in or on the electrode) with Ni 2p photoelectron spectrum when generated with Al Kα X‐rays. The use of simulated spectra involving both F and NiO demonstrates the extent of F Auger contributions to the Ni 2p signal strength as a function of the F/Ni atom ratio in the material and suggests spectra information that can be used to identify how significant effects will be on the resultant spectra. Our analysis demonstrates that in many cases overlap issues are significant for real electrode materials.

25 ENERGY STORAGE↗