Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray binaries”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

Orbital precession in Hercules X-1

It is noted that the 35-day X-ray high-low cycle of Her X-1 could be explained in terms of periodic obscuration of the source by a tilted and precessing 'slaved' accretion disk, which would require precession of the mass-shedding star and, consequently, a precessing binary orbit. Four months of Uhuru data obtained in 1972 are analyzed to determine whether the orbital precession can be detected as a Doppler modulation in the arrival times of the 1.24-sec X-ray pulsations. The precession geometry is examined, the test for precession is outlined, and a marginally significant indication of orbital precession in the Hz Her/Her X-1 system is obtained. Possible biases in the analysis are evaluated, and the spin-axis misalignment of HZ Her is estimated from the measured tilt of the orbit.

Deeter, J. E.↗

The X-ray polarization experiment on the OSO-8

The OSO-8 satellite, launched on June 21, 1975 contains two X-ray polarimeters. These polarimeters use mosaic crystals of graphite to yield polarization-sensitive Bragg reflection of stellar X-rays. The crystals reflect a narrow energy bandwidth centered at 2.6 and 5.2 keV. The polarimeter background signal is minimized by mounting the crystals on parabolic surfaces which focus the diffracted X-rays onto small-area, beryllium-window proportional counters. This technique permits the observation of low-intensity X-ray sources and reduces the possibility of systematic background effects which could lead to a false signature of polarization. A description of the instrument is given, and the sensitivity to polarization, particularly in regard to binary sources, is discussed. Preliminary results for Cen X-3 and GX5-1 are presented.

Weisskopf, M. C.↗

Thermal expansion: Metallic elements and alloys

The introductory sections of the work are devoted to the theory of thermal expansion of solids and to methods for the measurement of the linear thermal expansion of solids (X-ray methods, high speed methods, interferometry, push-rod dilatometry, etc.). The bulk of the work is devoted to numerical data on the thermal linear expansion of all the metallic elements, a large number of intermetallics, and a large number of binary alloy systems and multiple alloy systems. A comprehensive bibliography is provided along with an index to the materials examined.

Touloukian, Y. S.↗

The transient X-ray source A0620-00 - Intensity variations and evidence for an 8 day periodicity

The X-ray intensity of the transient source A0620-00 has been measured frequently with the SAS-3 X-ray Observatory from August 8, 1975 to February 13, 1976. This brightest of all known X-ray transients shows intensity variations on a time scale of days superposed on a general decline. Intensity data for the period from January 7 to February 13, 1976, show evidence of an approximate 7.8-day periodicity that may be the result of binary motion.

Matilsky, T.↗

Triaxial degenerate dwarfs and pulsing X-ray sources

It is shown that triaxial configurations for rotating degenerate dwarfs consisting entirely of fluid are not limited to forms analogous to the Jacobi ellipsoids. Arguments are presented which rule out only the specialized class of uniformly rotating analogs of the Jacobi ellipsoid for some degenerate dwarfs. Several ways of forming triaxial degenerate dwarfs are examined along with the characteristic lifetimes of such objects. Noting that some of the alternative forms may exist in mass-transfer binary systems, consideration is given to the secondaries in Her X-1 and Cen X-3. It is suggested that the secondary in Her X-1 must be close to an analog of a Dedekind ellipsoid, and plausible triaxial white-dwarf configurations are proposed for the secondary in Cen X-3.

Durisen, R. H.↗

Intense soft X-ray flux from Hercules X-1

An intense flux of soft X-rays extending up to at least 1 keV has been observed from Her X-1. If the soft X-ray intensity is corrected for interstellar absorption, the luminosity in the 0.16-0.28 keV band is comparable to that from 2 to 10 keV. This confirms the conclusion of Shulman et al. (1975) but extends the detection of this flux to higher energy, a different binary phase, and to a time 19 periods later in the 35-day cycle. These observations suggest that this soft emission may be a stable feature in the spectrum of Her X-1 during its X-ray on state. It appears difficult to account for the high soft X-ray luminosity by current simple models of the X-ray source.

Catura, R. C.↗

The transient periodic X-ray source in Taurus, A0535+26

Eighteen X-ray light curves of the 104-sec periodicity in the Taurus X-ray nova A 0535+26 are analyzed which were obtained by SAS-3 in six energy intervals between 1 and 35 keV during the period from May 30 to June 2, 1975. It is shown that the pulse structure is relatively simple at energies above 19 keV, but develops a complex series of five irregularly spaced maxima at lower energies. The energy spectrum averaged over the 104-sec period is found to be extremely hard, with a best-fit temperature of about 30 keV for the exponential spectrum, an excess at about 15 keV, and a steepening above 20 keV. It is suggested that A 0535+26 may be a compact object in a binary system containing the peculiar Be star HDE 245770. The transient behavior could arise due to episodic mass loss by the primary or because the compact object is in a highly eccentric orbit about the companion, with appreciable mass transfer occurring only at periastron.

Bradt, H.↗

High-energy X-ray observations of the southern sky

Results are reported for high-energy (above 17 keV) balloon-borne X-ray observations in the southern sky which detected at least five sources that produced X-ray counts above background with a significance of four or more standard deviations. The probable sources observed include GX 301-2 (3U 1223-62), GX 1+4 (3U 1728-24), GX 5-1 (3U 1758-25), GX 3+1 (3U 1744-26), and GX 331-1. It is noted that some or all of the flux attributed to GX 5-1 might be due to 3U 1820-30 and that GX 3+1 was not completely resolved from GX 1+4. Energy spectra are given for each source along with upper limits to periodic fluctuations of the detected fluxes in the frequency range from 0.01 to 100 Hz. A possible observation of a flux from the eclipsing binary source 3U 1700-37 is discussed.

Ricker, G. R.↗

The discovery of rapidly repetitive X-ray bursts from a new source in Scorpius

Rapidly repetitive X-ray bursts have been observed from a new X-ray source in Scorpius. More than 2000 bursts were observed during the 4-day continual SAS-3 observations of this source designated MXB 1730-335. The time interval between bursts varied from a minimum of about 6 s to a maximum of about 5 minutes. The energy in a given burst is approximately linearly proportional to the time interval to the next burst. The largest bursts observed last for about 60 s and represent an energy release of approximately 10 to the 40th ergs for an assumed distance to the source of 10 kpc. The smallest bursts observed last only for a few seconds. We suggest that the bursts are caused by sporadic precipitations of plasma from a reservoir in the magnetosphere of a neutron star. The reservoir is replenished at a nearly constant rate by mass transferred from a binary companion.

Lewin, W. H. G.↗

Optical candidates for two X-ray sources.

Suggestion of the bright stars X Per and HD 77581 as possible candidates for the X-ray sources 2U 0352+30 and 2U 0900-40 respectively. The first is an active, rapidly rotating Be star which is losing mass. The second is similar to BD+34.3815 deg, a likely candidate for Cyg X-1, in spectral type and in the possibility that it may be a short-period binary.

Brucato, R. J.↗

High energy and solar astronomy, overview

A survey of our own galaxy and neighboring galaxies using X-rays, gamma rays, and cosmic rays is outlined. High energy astrophysic results suggest the presence of a new acceleration mechanism where the inflow of matter on collapsed objects seems to be one of the sources of complex time variations in binary systems.

Mcdonald, F. B.↗

Discovery of the binary nature of SMC X-1 from Uhuru.

The X-ray source in the Small Magellanic Cloud SMC X-1 was observed by Uhuru on numerous occasions from December 1970 through April 1972. As previously reported by Leong et al. (1971), the source was seen to be variable. It was found that SMC X-1 occults with a period of 3.8927 days. The energy spectrum is cut off at low energies and flat. There is no large-amplitude periodic pulsation. The luminosity observed makes the binary source SMC X-1 comparable in strength to both the stronger galactic sources and the discrete sources in the Large Magellanic Cloud.

Schreier, E.↗

Pulsed X-ray observations of Cen X-3 from Ariel-5

The 4.8 second X-ray pulsations from Centaurus X-3 were monitored by the MSSL collimated proportional counter on board Ariel-5 between 18-27 January 1975. Analysis of the source Doppler effect shows that the pulsation period of Cen X-3 decreased by 3.70 + or - 0.04 milliseconds during the preceding 2.3 years. The Doppler analysis also yields updated values for the binary phase and period of Cen X-3. Phase zero occurred at JD 2442438.628 + or - 0.003, and the average heliocentric binary period between October 1972 and January 1975 was 2.087129 + or - 0.000007 days. Light curves of the 4.8 second pulsations in the 3-9 keV band are characterized by two pronounced peaks, in contrast with the single peak profiles observed by Uhuru.

Tuohy, I. R.↗

Optical observations of HDE 226868 = Cygnus X-1: A review

The present state of knowledge of the binary system HDE226868 = Cygnus X-1 is summarized, including system dimensions, nature of the secondary X-ray source, and mass transfer properties. Some deficiencies in the optical observations are pointed out; these deficiencies make interpretation of the system difficult, but can be corrected.

Bolton, C. T.↗

The X-ray variability of Vela X-1 (3U 0900-40)

From observations of Vela X-1 with the MSSL 2.5-7.5 keV detector onboard Copernicus, the behavior of the source can be characterized by three phases: (1) high intensity, (2) low intensity, and (3) eclipse. Combining data from the 1972 Uhuru observations with eclipse observation yields a binary period of 8.963 + or - 0.001 days with zero phase on 1975 Feb. 6.97 + or - 0.04 UT. The low intensity phase is interpreted as being due to increased absorption in an accretion wake traveling across the line of sight (the spectral slope remains relatively constant throughout the cycle). Another period of enhanced absorption immediately after exit from eclipse may be due to a bow shock. Comparison of the two observations suggests that these structures vary from cycle to cycle and, since the orbital period is long, probably during each cycle.

Charles, P. A.↗