Search NASA⌕ Search

SEARCH · Search NASA

Results for “X-ray reflectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A versatile Mossbauer spectrometer and its applications in vibration measurement

A Fe-57 Mossbauer spectrometer, equally efficient in transmission and reflection geometries, is described. The radiation detector consists of a 1.524- by 5.08 by 5.08-cm rectangular NaI(Tl) crystal with a hole 1.524 cm in diameter. The front and back faces of the crystal are covered with beryllium windows 0.0127 cm thick and 3.81 cm in diameter. The energy of the radiation accepted for counting ranges from 6.3 keV conversion X-rays to the 14.4 keV reemitted gamma rays. The spectrometer was used to measure various types of low frequency (10 Hz) and low amplitude (0.254 mm) periodic motion of steel specimens.

Singh, J. J.↗

A focusing collector for long wavelength X-ray astronomy.

Rocket studies of the low-energy X-ray sky conducted so far suffer from serious experimental problems. Therefore, an apparatus was design ed to overcome the outstanding experimental problems. The instrument developed was successfully flown in an Aerobee-170 rocket. The new device utilizes a grazing incidence paraboloid as an energy concentrator and low-pass filter. The effective bandpass of the instrument from 100 to 280 eV is determined by the combination of the counter window transmission and the mirror reflectivity.

Yentis, D. J.↗

An investigation of adhesive/adherend and fiber matrix interactions

Research during the report period focused on continued scanning electron microscopy (SEM) and X-ray photoelectron spectroscopy (XPS) of lap shear samples and flatwise tensile specimens and on the surface characterization of TiO2, Ti 6-4, and Ti powders with particular emphasis on their interaction with primer solutions of both polyphenylquinoxaline and LaRC-13 polyimide. The use of SEM and XPS in the analysis of Ti 6-4 adherend surfaces is described as well as differences in Ti 6-4 surface composition after different chemical pretreatments. Analysis of fractured surfaces is used to established the failure mode. The surface acidity of Ti 6-4 coupons can be established by reflectance visible spectroscopy using indicator dyes.

Beck, B.↗

Absorption of X-rays in the interstellar medium

The X-ray photoabsorption cross sections (per hydrogen atom) of interstellar clouds and the intercloud medium are calculated separately, taking into account abundance evolution, self-blanketing by grains, molecule formation, and ionization structure. A reference cross section describing a neutral monatomic gas of elements in solar abundances is computed for purposes of comparison, the cross section of the intercloud medium is calculated by assuming that 15% of the hydrogen is ionized, and the cross section of the clouds is computed for the cases where all hydrogen is in either molecular or atomic form. A comparison of the reference cross section with the others shows that a cross section is increased relative to the reference if abundances are enhanced or if molecular hydrogen exists and is decreased if atoms exist in grains or if hydrogen is ionized. It is noted that the total cross section will be a linear combination of the cross sections of the clouds and the intercloud medium and can reflect the characteristics of a particular line of sight.

Ride, S. K.↗

Imaging slitless spectrometer for X-ray astronomy

Imaging slitless spectrometer, a combination of an X ray transmission /or reflection/ grating and image-forming X ray telescope, is capable of obtaining simultaneous spatial and spectral information about celestial X ray sources.

Gursky, H.↗

Noncontacting device to indicate deflection of turbopump internal rotating parts

Phase 2 (development) which was concluded for the ultrasonic Doppler device and the light-pipe-reflectance device is reported. An ultrasonic Doppler breadboard system was assembled which accurately measured runout in the J-2 LOX pump impeller during operation. The transducer was mounted on the outside of the pump volute using a C-clamp. Vibration was measured by conducting the ultrasonic wave through the volute housing and through the fluid in the volute to the impeller surface. The impeller vibration was also measured accurately using the light-pipe probe mounted in an elastomeric-gland fitting in the pump case. A special epoxy resin developed for cryogenic applications was forced into the end of the fiber-optic probe to retain the fibers. Subsequently, the probe suffered no damage after simultaneous exposure to 2150 psi and 77 F. Preliminary flash X-radiographs were taken of the turbine wheel and the shaft-bearing-seal assembly, using a 2-megavolt X-ray unit. Reasonable resolution and contrast was obtained. A fast-neutron detector was fabricated and sensitivity was measured. The results demonstrated that the technique is feasible for integrated-time measurements requiring, perhaps, 240 revolutions to obtain sufficient exposure at 35,000 rpm. The experimental verification plans are included.

Hamilton, D. B.↗

A Bragg spectrometer for stellar X-ray astronomy.

Poor energy resolution and the steeply varying continuum spectrum make it impossible to obtain with proportional counters an unambiguous identification of certain emission features of Sco X-1. For this reason a Bragg crystal spectrometer was constructed. The instrument, flown successfully aboard an Aerobee-170 rocket, scanned the spectral range from 2.4 to 2.9 keV. The spectrometer consists of two large reflecting crystals of synthetic graphite. The results obtained during the flight of the instrument clearly indicate that the Bragg method can yield much higher sensitivity to line emission than can proportional counter methods.

Kestenbaum, H.↗

Three mirror glancing incidence system for X-ray telescope

A telescope suitable for soft X-ray astronomical observations consists of a paraboloid section for receiving rays at a grazing angle and a hyperboloid section which receives reflections from the paraboloid at a grazing angle and directs them to a predetermined point of focus. A second hyperboloid section is centrally located from the other two surfaces and positioned to reflect from its outer surface radiation which was not first reflected by the paraboloid. A shutter is included to assist in calibration.

Hoover, R. B.↗

Conical focusing crystal spectrometers for cosmic X-ray astronomy

A crystal spectrometer for rocket and satellite experiments is described. Parallel X rays from a stellar object are reflected at constant angle by Bragg crystals arranged around the sector of a cone so that a single wavelength is brought to a focus onto the axis of the cone. The aberrations produced when this array is tilted to change the wavelength are considered. It is shown that these are minimized by moving cone and detector in a nearly theta to two-theta motion and by using a small-angle sector. In a specific design for a satellite instrument using LiF crystal to observe a spectral region including the iron lines at 1.9 A, a spectral resolution of 3 mA over a spectral range of 1.6-2.1 A can be obtained, with the cosmic-ray background rate, and hence the time to detect a weak line decreased by a factor 80 compared to a flat crystal spectrometer. Examples of performance for a low energy rocket experiment are also given.

Woodgate, B. E.↗

Stellar and solar X-ray polarimetry

Astronomical stellar and solar studies involving X-ray polarimetry are discussed along with the statistical limitations inherent in polarimeter measurements and the design principles of a number of polarimeter types. Attention is given to photoelectric polarimeters, secondary fluorescence X-ray polarimeters, Borrmann-effect polarimeters, circular polarization analyzers, gamma-ray polarimeters, and multilayer reflection polarimeters. Bragg crystal polarimeters are considered, taking into account the theory of the polarimeter operation, aspects of instrument design, and the occurrence of systematic errors. The design and the performance of a rocket and a satellite Thomson-scattering polarimeter are also examined.

Novick, R.↗

Observations of the Circinus X-1 region

The X-ray telescope on board the OSO-7 satellite has provided observations of the Cir X-1 region for over 110 days between December 1971 and March 1973. Although statistically significant fluctuations in the 7- to 11-keV flux were measured, no periodicities in the range between 5 hours and 100 days were found to an upper limit of about 40 percent amplitude. Intensities in the 7- to 57-keV range show variability by a factor of approximately 25 and changes in the spectral shape reflected by a number spectral index varying from about 1.1 to about 3.0. There is a positive correlation between intensity and spectral shape, with a steeper spectrum at times of peak intensity. Although power-law, exponential, and blackbody spectral shapes are equally good fits to these data alone, examination of all the available data appears to rule out a simple blackbody spectrum, at least at times of maximum intensity.

Baity, W. A.↗

Mineralogy, petrology, and geochemistry of the lunar samples

The geochemistry of the bulk moon is considered, taking into account the large-scale chemical view of the lunar surface which has been obtained with the aid of three remote sensing experiments utilizing X-ray fluorescence, a gamma-ray spectrometer, and visible and near infrared reflectance measurements. Attention is also given to the regolith, the mare basins, and the lunar highlands and crust.

Warner, J.↗

Molecular hydrogen in the Galaxy and galactic gamma rays

Recent surveys of 2.6-cm CO emission and 100-MeV gamma-radiation in the galactic plane reveal a striking correlation suggesting that both emissions may be primarily proportional to the line-of-sight column density of H2 in the inner Galaxy. Both the gamma-ray and CO data suggest a prominent ring or arm consisting of cool clouds of H2 at a galactocentric distance of about 5 kpc with a mean total hydrogen density equivalent to approximately 5 atoms per cu cm. Estimates are made of column densities of H2 at 0 deg galactic longitude and are compared with estimates from infrared and X-ray absorption measurements. These estimates are all consistent, indicating that H2 is far more abundant than H I in the inner Galaxy and is the key to a more satisfactory explanation of the gamma-ray observations than previous suggestions. The importance of H2 in understanding galactic gamma-ray observations is also reflected in the correlation of galactic-latitude distribution of gamma-rays and dense dust clouds. The deduced cosmic-ray distribution inferred from the calculations is similar to that of galactic supernova remnants, suggesting a galactic origin for most cosmic rays.

Stecker, F. W.↗

Vignetting characteristics of the S-056 X-ray telescope

A ray trace analysis of the vignetting characteristics of the S-056 X ray telescope is presented. The relative energy is calculated in the spot formed in the focal plane of the S-056 X ray telescope by an off axis point source at infinity for off axis angles of 0, 1, 2, ..., 35 arc minutes. At each off axis angle, the relative energies are evaluated using theoretical X ray reflectivity curves for wavelengths of 8.34 A, 17.57 A, and 27.39 A, and also using an experimental X ray reflectivity curve for 8.34 A. The effects of vignetting due purely to the geometry of the S-056 optical system are evaluated separately, as well as jointly with the effects of mirror reflectivity.

Foreman, J. W., Jr.↗

Backscatter of hard X-rays in the solar atmosphere

The solar photosphere backscatters a substantial fraction of the hard X rays from solar flares incident upon it. This reflection was studied using a Monte Carlo simulation which takes into account Compton scattering and photo-electric absorption. Both isotropic and anisotropic X ray sources are considered. The bremsstrahlung from an anisotropic distribution of electrons are evaluated. By taking the reflection into account, the inconsistency is removed between recent observational data regarding the center-to-limb variation of solar X ray emission and the predictions of models in which accelerated electrons are moving down toward the photosphere.

Bai, T.↗

Design, fabrication and expected performance of the HEAO-B X ray telescope

The X-ray telescope of the second High Energy Astronomy Observatory (HEAO-B) is described. The design consists of four concentric paraboloid/hyperboloid pairs. Focal length is 3.44 meters, paraboloid diameters vary from 580-336 mm, grazing angles vary from 70 to 40 arcmin for paraxial rays, segment lengths are 511 mm. The reflecting surfaces are nickel-coated fused quartz and the resolution is limited by assembly errors (for small field angles) and design aberrations (for large field angles). The local slope, roundness, and surface roughness are identified as the primary optical tolerances connected with the individual elements.

Van Speybroeck, L. P.↗