Search NASA⌕ Search

SEARCH · Search NASA

Results for “accelerator test facility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

A Project to Design and Build the Magnets for a New Test Beamline, the ATF2, at KEK

In order to achieve the high luminosity required at the proposed International Linear Collider (ILC), it is critical to focus the beams to nanometer size with the ILC Beam Delivery System, and to maintain the beams collisions with a nanometer-scale stability. To establish the technologies associated with this ultra-high precision beam handling, a special beamline has been designed and built as an extension of the existing extraction beamline of the Accelerator Test Facility at KEK, Japan. The ATF provides an adequate ultra-low emittance electron beam that is comparable to the ILC requirements; the ATF2 mimics the ILC final focus system to create a tightly focused, stable beam. There are 37 magnets in the ATF2, 29 quadrupoles, 5 sextupoles and 3 bends. These magnets had to be acquired in a short time and at minimum cost, which led to various acquisition strategies; but nevertheless they had to meet strict requirements on integrated strength, physical dimensions, compatibility with existing magnet movers and beam position monitors, mechanical stability and field stability and quality. This paper will describe how 2 styles of quadrupoles, 2 styles of sextupoles, one dipole style and their supports were designed, fabricated, refurbished or modified, measured and aligned by a small team of engineers from 3 continents.

43 PARTICLE ACCELERATORS↗

ATF2 High Availability Power Supplies

ATF2 is an accelerator test facility modeled after the final focus beamline envisioned for the ILC. By the end of 2008, KEK plans to commission the ATF2 [1]. SLAC and OCEM collaborated on the design of 38 power systems for beamline magnets. The systems range in output power from 1.5 kW to 6 kW. Since high availability is essential for the success of the ILC, Collaborators employed an N+1 modular approach, allowing for redundancy and the use of a single power module rating. This approach increases the availability of the power systems. Common power modules reduces inventory and eases maintenance. Current stability requirements are as tight as 10 ppm. A novel, SLAC designed 20-bit Ethernet Power Supply Controller provides the required precision current regulation. In this paper, Collaborators present the power system design, the expected reliability, fault immunity features, and the methods for satisfying the control and monitoring challenges. Presented are test results and the status of the power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cavity Beam Position Monitor System for ATF2

The Accelerator Test Facility 2 (ATF2) in KEK, Japan, is a prototype scaled demonstrator system for the final focus required for a future high energy lepton linear collider. The ATF2 beam-line is instrumented with a total of 38 C and S band resonant cavity beam position monitors (CBPM) with associated mixer electronics and digitizers. The current status of the BPM system is described, with a focus on operational techniques and performance. The ATF2 C-band system is performing well, with individual CBPM resolution approaching or at the design resolution of 50 nm. The changes in the CBPM calibration observed over three weeks can probably be attributed to thermal effects on the mixer electronics systems. The CW calibration tone power will be upgraded to monitor changes in the electronics gain and phase. The four S-band CBPMs are still to be investigated, the main problem associated with these cavities is a large cross coupling between the x and y ports. This combined with the large design dispersion in that degion makes the digital signal processing difficult, although various techniques exist to determine the cavity parameters and use these coupled signals for beam position determination.

43 PARTICLE ACCELERATORS↗

Laser Wakefield Acceleration Driven by a CO2 Laser (STELLA-LW) - Final Report

The original goals of the Staged Electron Laser Acceleration – Laser Wakefield (STELLA-LW) program were to investigate two new methods for laser wakefield acceleration (LWFA). In pseudo-resonant LWFA (PR-LWFA), a laser pulse experiences nonlinear pulse steepening while traveling through the plasma. This steepening allows the laser pulse to generate wakefields even though the laser pulse length is too long for resonant LWFA to occur. For the conditions of this program, PR-LWFA requires a minimum laser peak power of 3 TW and a low plasma density (10^16 cm^-3). Seeded self-modulated LWFA (seeded SM-LWFA) combines LWFA with plasma wakefield acceleration (PWFA). An ultrashort (~100 fs) electron beam bunch acts as a seed in a plasma to form a wakefield via PWFA. This wakefield is subsequently amplified by the laser pulse through a self-modulated LWFA process. At least 1 TW laser power and, for a ~100-fs bunch, a plasma density ~10^17 cm^-3 are required. STELLA-LW was located on Beamline #1 at the Brookhaven National Laboratory (BNL) Accelerator Test Facility (ATF). The ATF TW CO2 laser served as the driving laser beam for both methods. For PR-LWFA, a single bunch was to probe the wakefield produced by the laser beam. For seeded SM-LWFA, the ATF linac would produce two bunches, where the first would be the seed and the second would be the witness. A chicane would compress the first bunch to enable it to generate wakefields via PWFA. The plasma source was a short-length, gas-filled capillary discharge with the laser beam tightly focused in the center of the capillary, i.e., no laser guiding was used, in order to obtain the needed laser intensity. During the course of the program, several major changes had to be made. First, the ATF could not complete the upgrade of the CO2 laser to the 3 TW peak power needed for the PR-LWFA experiment. Therefore, the PR-LWFA experiment had to be abandoned leaving only the seeded SM-LWFA experiment. Second, the ATF discovered that the chicane bifurcated the incoming bunch into two compressed bunches separated in time and energy. With the available equipment it was not possible to stop the bifurcation. In an attempt to still deliver a single compressed bunch to the experiment, a slit was used to block one of the bunches, but this also blocked any witness bunch. Third, the loss of the witness bunch meant a different method for detecting the effect of the laser beam on the wakefield had to be implemented. Hence, a coherent Thomson scattering (CTS) diagnostic was designed and assembled. Unfortunately, further tests with blocking one of the double-bunches showed that wakefield generation was too unstable and difficult to control for the seeded SM-LWFA experiment. Luckily, it was found that a fast-rising (~50 fs) bunch could be created along Beamline #2 that was capable of generating wakefields, did not use the chicane, and was more stable. Thus, as the fourth major change, the entire STELLA-LW apparatus, including the CTS diagnostic, was moved from Beamline #1 to Beamline #2. Because this move occurred near the end of the program, only a single 2-week run could be performed. During the run it was found the laser beam transmission through the capillary discharge was severely degraded when the plasma was on. This loss of transmission appeared to be due to defocusing of the laser beam probably caused by laser-induced ionization creating a lens effect inside the capillary. Defocusing could also cause laser light to strike the capillary wall, thereby producing ablation and localized changes in the plasma density. Any changes in the plasma density would disrupt the plasma resonance condition for the wakefield. It was also discovered after the run that the ATF laser was producing multiple output pulses. The leading pulse could have caused ionization that interfered with transmission of the following pulses. Worse yet, the peak power in each of the pulses was several times smaller than if all the pulse energy was in a single pulse. This meant each pulse had less than 1 TW power. Wakefield formation with no laser beam present was confirmed by observing energy loss of the fast-raising seed bunch passing through the capillary discharge. When the laser beam was sent into the plasma, no CTS signal was detected, probably due to defocusing of the laser light, changes in the plasma density due to laser-induced ionization, and insufficient peak power in the individual pulses. It is for these reasons we were not able to validate the seeded SM-LWFA predictions. In summary, the STELLA-LW experiment was not able to demonstrate seeded SM-LWFA or PR-LWFA primarily because of limitations of the ATF CO2 laser, both in its deliverable peak power and its ability to provide a single laser pulse.

43 PARTICLE ACCELERATORS↗

Measurements of terahertz radiation generated using a metallic, corrugated pipe

Here, a method for producing narrow-band THz radiation proposes passing an ultra-relativistic beam through a metallic pipe with small periodic corrugations. We present results of a measurement of such an arrangement at Brookhaven's Accelerator Test Facility (ATF). Our pipe was copper and was 5 cm long; the aperture was cylindrically symmetric, with a 1 mm (radius) bore and a corrugation depth (peak-to-peak) of 60 µm. In the experiment we measured both the effect on the beam of the structure wakefield and the spectral properties of the radiation excited by the beam. We began by injecting a relatively long beam compared to the wavelength of the radiation, but with short rise time, to excite the structure, and then used a downstream spectrometer to infer the radiation wavelength. This was followed by injecting a shorter bunch, and then using an interferometer (also downstream of the corrugated pipe) to measure the spectrum of the induced THz radiation. For the THz pulse we obtain and compare with calculations: the central frequency, the bandwidth, and the spectral power—compared to a diffraction radiation background signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Simulation study of CO 2 laser-plasma interactions and self-modulated wakefield acceleration

3D numerical simulations of the interaction of a powerful CO 2 laser with hydrogen jets demonstrating the role of ionization on the characteristics of induced wakes are presented. Simulations using SPACE, a parallel relativistic Particle-in-Cell code, are performed in support of the plasma wakefield accelerator experiments being conducted at the Brookhaven National Laboratory (BNL) Accelerator Test Facility (ATF). A novelty of the SPACE code is its set of efficient atomic physics algorithms that compute ionization and recombination rates on the grid and transfer them to particles. The influence of ionization on the spectrum of pump laser has been studied for a range of gas densities.Simulations reproduce both Stokes and anti-Stokes shifts in the spectrum of pump laser, similar to those observed in experiments in the spectrum of probe. A good agreement has been achieved with the experiments on the effect of variation in gas density on Stokes/anti-Stokes intensity. In addition, self-injection and trapping of electrons into the self-modulated wakes has been observed and analyzed. Here, the experimentally validated code SPACE will be used for predictive simulations to guide future experiments at BNL ATF.

97 MATHEMATICS AND COMPUTING↗

A general Bayesian algorithm for the autonomous alignment of beamlines

Autonomous methods to align beamlines can decrease the amount of time spent on diagnostics, and also uncover better global optima leading to better beam quality. The alignment of these beamlines is a high-dimensional expensive-to-sample optimization problem involving the simultaneous treatment of many optical elements with correlated and nonlinear dynamics. Bayesian optimization is a strategy of efficient global optimization that has proved successful in similar regimes in a wide variety of beamline alignment applications, though it has typically been implemented for particular beamlines and optimization tasks. In this paper, we present a basic formulation of Bayesian inference and Gaussian process models as they relate to multi-objective Bayesian optimization, as well as the practical challenges presented by beamline alignment. We show that the same general implementation of Bayesian optimization with special consideration for beamline alignment can quickly learn the dynamics of particular beamlines in an online fashion through hyperparameter fitting with no prior information. We present the implementation of a concise software framework for beamline alignment and test it on four different optimization problems for experiments on X-ray beamlines at the National Synchrotron Light Source II and the Advanced Light Source, and an electron beam at the Accelerator Test Facility, along with benchmarking on a simulated digital twin. We discuss new applications of the framework, and the potential for a unified approach to beamline alignment at synchrotron facilities.

47 OTHER INSTRUMENTATION↗

Channeling and radiation experiments at SLAC

Since 2014, a SLAC-Aarhus-Ferrara-CalPoly collaboration augmented by members of ANL and MIT has performed electron and positron channeling experiments using bent silicon crystals at the SLAC End Station A Test Beam as well as the FACET accelerator test facility. These experiments have revealed a remarkable channeling efficiency of about 24% under our conditions. Volume reflection is even more efficient with almost the whole beam taking part in the reflection process. A positron experiment demonstrated quasi-channeling oscillations for the first time at high beam energy. In our most recent experiment we measured the spectrum of gamma radiation for crystal orientations covering channeling and volume reflection. We report this series of experiments supports the development of more advanced crystalline devices capable e.g. of producing narrow-band gamma rays with electron beams or studying the interaction of the electrons with the wakefields generated in the crystal at high beam intensity.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Preliminary Report on Oak Ridge National Laboratory Testing of Drake/ACSS/MA2/E3X

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of a new conductor technology under real world conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr with E3X Technology a standard overhead conductor with an inorganic high emissivity, low absorptivity surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides initial results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Report on Oak Ridge National Laboratory Testing of Southwire 795 C7 Round Wire

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductors and conductor instrumentation under field conditions. PCAT is set up to capture large amounts of data during testing.

36 MATERIALS SCIENCE↗

Report on Oak Ridge National Laboratory Testing of Ambient Cure TransPowr E3X®

A key to industry acceptance of a new technology is extensive validation in field trials. The Powerline Conductor Accelerated Test facility (PCAT) at Oak Ridge National Laboratory (ORNL) is specifically designed to evaluate the performance and reliability of novel overhead conductor and conductor instrumentation under field conditions. The facility is set up to capture large amounts of data during testing. General Cable used the ORNL PCAT facility to validate the performance of TransPowr® with Ambient Cure E3X™ Technology—a standard overhead conductor with a high emissivity, low absorptivity ambient cure surface coating. Extensive testing has demonstrated a significant improvement in conductor performance across a wide range of operating temperatures with respect to uncoated conductor of the same type, indicating that E3X Technology can provide a reduction in temperature, a reduction in sag, and an increase in ampacity when applied to the surface of any overhead conductor. This report provides results of that testing.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Fermilab Cryogenic Test Facilities

Fermi National Accelerator Laboratory (Fermilab) has multiple cryogenic test facilities, undertaking testing of superconducting magnets, Superconducting Radio Frequency (SRF) cavities, SRF cryomodules and other helium cryogenic components. The test areas within Fermilab include: Meson Cryogenic Test facility (Meson), Industrial Building 1 (IB-1), Heavy Assembly Building/Illinois Accelerator Research Center (HAB/IARC), New Muon Lab, (NML) and the Cryomodule Test Facility (CMTF). Meson and HAB/IARC utilize repurposed Tevatron era reciprocating engine based cryogenic refrigerator systems, whereas CMTF and IB-1 utilize gas bearing turbine based coldboxes. Each of these test areas support the various Fermilab projects and collaborations including the Linear Coherent Light Source II (LCLS-II), Proton Improvement Plan II (PIP-II), High Luminosity Large Hadron Collider (HL-LHC), and Mu2e. This paper outlines the diverse and extensive cryogenic test capabilities within Fermilab.

43 PARTICLE ACCELERATORS↗

New Approach and Test Facility for High Field Accelerator Magnets R&D

This paper presents a new approach for developing and demonstrating high field magnet technology based on a magnet and test facility developed specifically for it. The traditional approach for carrying out high field magnet R&D has been building a new magnet to demonstrate a new design, new material or new technology. However, building a high field magnet is time consuming and expensive. To overcome this limitation, Brookhaven National Laboratory (BNL) built and successfully tested a 10 T Nb 3 Sn dipole DCC017 with large enough open or clear space (31 mm wide and 338 mm high) so that a pair of racetrack coils could be inserted into this opening without disassembling the magnet. The motivation be-hind this design was to facilitate a magnet R&D program where the new coils (with a large range in width and height accommodated) would reside in a high field region in direct contact with the existing coils (just as other magnet coils) and thus become an integral part of the magnet. We summarize the approach, the magnet, the test facility, past experiences, current and future test plans and planned up-grade. Here, the magnet facility is now available to service the needs of the wider community for testing cable and insert coils in a back-ground field of up to 10 T.

43 PARTICLE ACCELERATORS↗