Search NASASearch

SEARCH · Search NASA

Results for “accelerometers accelerometer calibration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

EGS Collab Experiment 2: Microseismic Monitoring

This dataset contains continuous seismic waveform data recorded during stimulation and thermal circulation tests for the Enhanced Geothermal Systems (EGS) Collab Experiment #2, conducted from February to September 2022 at the Sanford Underground Research Facility in Lead, South Dakota. This experiment aimed to study and validate models of geothermal systems by injecting high-pressure fluids into rock formations 1200-1500 meters below the surface, inducing microseismic events. The seismic monitoring system included 16 three-component accelerometers and a 24-channel hydrophone array, installed in boreholes surrounding the test area. Data were recorded at high sampling rates using a continuous waveform recording system to monitor seismic activity in real time. The dataset contains the raw data stored in binary format, with files named based on timestamps, and includes calibration certificates for some sensors to facilitate corrections to real units. Users are strongly advised to consult the accompanying detailed report, which outlines the experimental setup, sensor specifications, installation procedures, and data processing methods. The report also describes important nuances, such as the hardware filters on hydrophones, sensor calibration details, and the naming conventions for the recorded data. Proper use of this dataset may require familiarity with seismic data analysis tools, such as the Obspy Python package, and an understanding of the SEED naming conventions used for channel identification.

15 GEOTHERMAL ENERGY

Active nutation controller

An apparatus is described for controlling nutation motion in a spinning body, comprised of an angular accelerometer with its input axis perpendicular to the spin axis of the body, a flywheel with an axis of rotation perpendicular to the axis of the accelerometer and to the spin axis of the body, and a motor for driving the flywheel to attenuate or build nutation. The motor is controlled by circuitry that monitors the output of the angular accelerometer and drives the motor clockwise or counterclockwise during predetermined nutation angles synchronized to the zero crossover points of the accelerometer signal centered about the nutation peaks. The motor drive is phased to damp nutation motion to zero for stabilization. To increase the noise immunity of the system, when the output of the accelerometer falls below a threshold level, the circuitry operates in an open loop, beat mode where data representing the last accelerometer signal that exceeded that threshold level is stored, and the motor drive is controlled by the stored data. In a second version, the motor is controlled to supply a predetermined amount of nutation motion to a body undergoing testing on a spin table for energy dissipation evaluation. In each version, the use of an angular accelerometer rather than a linear accelerometer or gyro to monitor nutation enables placement of the nutation control apparatus at any location relative to the spin axis of the body requiring only crude orientation and no calibration.

Hoffman, H. C.

Development and Calibration of a System-Integrated Rotorcraft Finite Element Model for Impact Scenarios

Two full-scale crash tests of an MD-500 helicopter were conducted in 2009 and 2010 at NASA Langley's Landing and Impact Research Facility in support of NASA s Subsonic Rotary Wing Crashworthiness Project. The first crash test was conducted to evaluate the performance of an externally mounted composite deployable energy absorber (DEA) under combined impact conditions. In the second crash test, the energy absorber was removed to establish baseline loads that are regarded as severe but survivable. The presence of this energy absorbing device reduced the peak impact acceleration levels by a factor of three. Accelerations and kinematic data collected from the crash tests were compared to a system-integrated finite element model of the test article developed in parallel with the test program. In preparation for the full-scale crash test, a series of sub-scale and MD-500 mass simulator tests were conducted to evaluate the impact performances of various components and subsystems, including new crush tubes and the DEA blocks. Parameters defined for the system-integrated finite element model were determined from these tests. Results from 19 accelerometers placed throughout the airframe were compared to finite element model responses. The model developed for the purposes of predicting acceleration responses from the first crash test was inadequate when evaluating more severe conditions seen in the second crash test. A newly developed model calibration approach that includes uncertainty estimation, parameter sensitivity, impact shape orthogonality, and numerical optimization was used to calibrate model results for the full-scale crash test without the DEA. This combination of heuristic and quantitative methods identified modeling deficiencies, evaluated parameter importance, and proposed required model changes. The multidimensional calibration techniques presented here are particularly effective in identifying model adequacy. Acceleration results for the calibrated model were compared to test results and the original model results. There was a noticeable improvement in the pilot and copilot region, a slight improvement in the occupant model response, and an over-stiffening effect in the passenger region. One lesson learned was that this approach should be adopted early on, in combination with the building-block approaches that are customarily used, for model development and pretest predictions. Complete crash simulations with validated finite element models can be used to satisfy crash certification requirements, potentially reducing overall development costs.

Annett, Martin S.

Ares I-X Launch Vehicle Modal Test Measurements and Data Quality Assessments

The Ares I-X modal test program consisted of three modal tests conducted at the Vehicle Assembly Building at NASA s Kennedy Space Center. The first test was performed on the 71-foot 53,000-pound top segment of the Ares I-X launch vehicle known as Super Stack 5 and the second test was performed on the 66-foot 146,000- pound middle segment known as Super Stack 1. For these tests, two 250 lb-peak electro-dynamic shakers were used to excite bending and shell modes with the test articles resting on the floor. The third modal test was performed on the 327-foot 1,800,000-pound Ares I-X launch vehicle mounted to the Mobile Launcher Platform. The excitation for this test consisted of four 1000+ lb-peak hydraulic shakers arranged to excite the vehicle s cantilevered bending modes. Because the frequencies of interest for these modal tests ranged from 0.02 to 30 Hz, high sensitivity capacitive accelerometers were used. Excitation techniques included impact, burst random, pure random, and force controlled sine sweep. This paper provides the test details for the companion papers covering the Ares I-X finite element model calibration process. Topics to be discussed include test setups, procedures, measurements, data quality assessments, and consistency of modal parameter estimates.

Templeton, Justin D.

Digital Pitch-And-Roll Monitor

Highly accurate inclinometer developed. Monitors both pitch and roll simultaneously and provides printed output on demand. Includes three mutually perpendicular accelerometers and signal-conditioning circuitry converting outputs of sensors to digital values of pitch and roll. In addition to wind-tunnel applications, system useful in any application involving steady-state, precise sensing of angles, such as calibration of robotic devices and positioners.

Finley, Tom D.

2001 Atlanta Household Travel Survey

The 2001 Atlanta Household Travel Survey collected demographic, socioeconomic, and travel information on work and non-work travel behavior for a 48-hour travel period. The study was conducted on behalf of the Atlanta Regional Commission, and it is an essential element in the transportation planning and modeling efforts for the 13-county Atlanta region. The main objective of the study was to produce data that could be used to develop and calibrate travel demand models for use in travel forecasting, land use planning, and air quality planning to improve the transportation system. The second component in the survey was the deployment of an electronic travel diary with person-based GPS and an accelerometer to collect health and activity information. Travel data includes trip generation, trip distribution, and modal choice. The survey recruited a total of 12,184 households to participate in the study. Of these, 8,069 households (66%) completed travel. The 8,069 households, when weighted, represent 21,323 persons, 14,449 vehicles, and 126,127 places visited from April 2001 through April 2002. This dataset is part of the Metropolitan Travel Survey Archive, which includes travel surveys from numerous public agencies across the United States and is archived by the Transportation Secure Data Center to ensure their continued public availability.

1Hz data

Unsteady environments and responses of the shuttle combined loads orbiter test

Both separate and combined wind tunnel and vibration shaker tests were conducted on two structural panels representative of the Shuttle orbiter in the NASA LaRC 8-foot transonic pressure tunnel (TPT) to determine the effects of combined loads on the thermal protection system (TPS). The primary objective of this test was to provide a combined full-scale load environment and realistic time history of the dynamic pressures, Mach numbers (through transonic), and dynamic structural responses of these panels. The panels were selected from orbiter locations where interactive load sources such as aerodynamic shock waves, turbulent boundary layers, strut-induced vorticity, and substrate deformation combined to provide high bonding loads between the TPS and the orbiter structure. The test panels for this program were highly instrumented with static and dynamic pressure gages, accelerometers, deflectometers, strain gages, Schileren and high-speed photography, and special instrumentation necessary to determine TPS/structure interface loads and tile motions. Two test specimens of each orbiter panel were utilized. Both were high-fidelity representations of the selected orbiter location. The first panel (calibration panel) for each test was utilized to calibrate the tunnel and shaker system as well as provide a data-gathering source for applied static and dynamic loads. The second panel (test panel) for each test was subjected to flight time exposures only so that TPS characteristics as a function of flight mission exposure could be determined. These tests were the last in a series that was suce6ssfully completed and necessary to certify the TPS prior to the first launching of the Shuttle.

P. H. Schuetz

Advancements in Force and Angle Measurement by the NFMTC

The National Force Measurement Technology Capability (NFMTC) is a nationwide partnership established in 2008 and sponsored by NASA’s Aeronautics Evaluation and Test Capabilities (AETC) project to maintain and further develop force and angle measurement capabilities primarily for NASA’s ground test facilities. One of the NFMTC’s primary objectives is to develop new force and angle measurement capabilities to meet the needs of researchers testing in NASA’s ground test facilities. This work will highlight several new capabilities that are either at or near operational readiness. A new six-component flow-through balance was designed and fabricated to support an upcoming retropropulsion test campaign at the NASA Langley Unitary Plan Wind Tunnel. The balance employs membranes in place of bellows, which have historically been used, and passes the flow through load bearing parts of the balance. Flow through the balance is optimized via the addition of flow guides, which are manufactured as separate parts, and attached to the balance. Calibration of this new flow-through balance demonstrates that it can suitably characterize the load and pressure ranges it was designed for, which provides aero researchers a new tool to directly measure retropropulsion performance of powered descent vehicles. Balances used in NASA’s ground test facilities are typically either single-piece balances or floating-frame balances. Historically, these two types of balances have generally used different front-end (model) attachments. Single-piece balances generally have a cylindrical front end that is forward of any measuring sections and at a reduced diameter relative to the balance outer diameter. Floating-frame balances generally have front end fits that extend over one or more measuring sections and that engage at the balance outer diameter. Recently, the NFMTC fabricated a single-piece balance with a front end fit that is compatible with the hardware used to calibrate floating-frame balances. Calibration results evaluating this front end fit will be presented. From a recent survey of angle measurement needs, the development of smaller angle measurement packages was identified as one area of improvement. Micro-electromechanical systems (MEMS) are continually being refined to provide high performance accelerometers that are a fraction of the volume of the quartz flexure based accelerometers that are standard in wind tunnels. A survey of commercial off-the-shelf MEMS accelerometers was conducted, and it identified the Safran Colibrys MS lines to be of adequate performance. Single-axis test boards and tri-axis rigid-flex production boards were designed and fabricated with a volume of approximately .18 cubic inches. The boards were designed to provide all the necessary conditioning for the MEMS accelerometers at levels to meet or exceed all requirements for the MS line sensors. Preliminary testing of these assembled sensor packages has demonstrated acceptable performance for wind-tunnel angle measurement. Several new rotating balances are at various stages of completion for NASA Glenn Research Center’s fan drive rigs. These balances provide direct measurement of thrust and torque of a driven fan or fan section to provide an estimate of fan efficiency and net thrust. Three two-component balances have been recently completed, and one six-component balance is in active development. A custom rotating telemetry system has been developed to support testing with these balances, and the telemetry system is integrated into the forward end of each one. The telemetry system is designed to remove mechanical sliprings by using an optical ethernet-based slipring for data transmission.

Force measurement

An ultrasonic flowmeter for measuring dynamic liquid flow

A novel oscillating pipe system was developed to provide dynamic calibration wherein small sinusoidal signals with amplitudes of 0.5 to 10% of the steady-state flow were added to the steady-state flow by oscillating the flowmeter relative to the fixed pipes in the flow system. Excellent agreement was obtained between the dynamic velocities derived from an accelerometer mounted on the oscillating pipe system and those sensed by the flowmeter at frequencies of 7, 19, and 30 Hz. Also described were the signal processing techniques used to retrieve the small sinusoidal signals which were obscured by the fluid turbulence.

Carpini, T. D.

Redundant Strapdown Laser Gyro Navigation System

For the last several years, NASA has pursued the development of low-cost high-reliability inertial navigation systems that would satisfy a broad spectrum of future space and avionics missions. Two specific programs have culminated in the construction of a Redundant Strapdown Laser Gyro Navigation System. These two programs were for development of a space ultrareliable modular computer (SUMC) and a redundant laser gyro inertial measurement unit (IMU). The SUMC is a digital computer that employs state-of-the-art large-scale integrated circuits configured in a functional modular breakdown. The redundant laser gyro IMU is a six-pack strapdown sensor package in a dodecahedron configuration which uses six laser gyros to provide incremental angular positions and six accelerometers for linear velocity outputs. The sensor arrangement allows automatic accommodation of two failures; a third failure can be tolerated provided it can be determined. The navigation system also includes redundant power supplies, built-in test-equipment (BITE) circuits for failure detection, and software which provides for navigation, redundancy management, and automatic calibration and alignment.

Mcpherson, B. W.

(abstract) A Miniature, High-Sensitivity, Electron-Tunneling Accelerometer

A prototype low-noise accelerometer has been fabricated with an electron-tunneling transducer. By measuring the tunneling current between an electrode on the proof mass and a feedback-controlled monitor electrode, very small accelerations can be detected with high responsivity. This particular prototype (10x10x1.5 mm) was designed for underwater acoustic measurement from a few hertz to 1 kHz. The measured responsivity below the fundamental device resonance at 100 Hz is roughly 1500 volts per m/s(sup 2) with a measured noise spectral density of 10(sup -6) m/s(sup 2) per root hertz or less between 30 and 300 Hz. The noise floor is controlled primarily by 1/f noise in the tunneling current although the noise floor reaches the theoretical molecular-agitation limit at 100 hertz. The responsivity and directivity of the device were measured in a standard gradient-hydrophone calibrator; the noise floor was determined in a vacuum-ionization chamber assembled from commercial off-the-shelf components; and the detailed dynamics of the proof-mass motion were examined using a heterodyne laser interferometer that was scanned across the surface and synchronously detected with respect to the excitation.

accelerometer electron tunneling acoustic measurem

A preliminary look at techniques used to obtain airdata from flight at high angles of attack

Flight research at high angles of attack has posed new problems for airdata measurements. New sensors and techniques for measuring the standard airdata quantities of static pressure, dynamic pressure, angle of attack, and angle of sideslip were subsequently developed. The ongoing airdata research supporting NASA's F-18 high alpha research program is updated. Included are the techniques used and the preliminary results. The F-18 aircraft was flown with three research airdata systems: a standard airdata probe on the right wingtip, a self-aligning airdata probe on the left wingtip, and a flush airdata system on the nose cone. The primary research goal was to obtain steady-state calibrations for each airdata system up to an angle of attack of 50 deg. This goal was accomplished and preliminary accuracies of the three airdata systems were assessed and are presented. An effort to improve the fidelity of the airdata measurements during dynamic maneuvering is also discussed. This involved enhancement of the aerodynamic data with data obtained from linear accelerometers, rate gyros, and attitude gyros. Preliminary results of this technique are presented.

Moes, Timothy R.

Thrust Stand for Electric Propulsion Performance Evaluation

An electric propulsion thrust stand capable of supporting thrusters with total mass of up to 125 kg and 1 mN to 1 N thrust levels has been developed and tested. The mechanical design features a conventional hanging pendulum arm attached to a balance mechanism that transforms horizontal motion into amplified vertical motion, with accommodation for variable displacement sensitivity. Unlike conventional hanging pendulum thrust stands, the deflection is independent of the length of the pendulum arm, and no reference structure is required at the end of the pendulum. Displacement is measured using a non-contact, optical linear gap displacement transducer. Mechanical oscillations are attenuated using a passive, eddy current damper. An on-board microprocessor-based level control system, which includes a two axis accelerometer and two linear-displacement stepper motors, continuously maintains the level of the balance mechanism - counteracting mechanical %era drift during thruster testing. A thermal control system, which includes heat exchange panels, thermocouples, and a programmable recirculating water chiller, continuously adjusts to varying thermal loads to maintain the balance mechanism temperature, to counteract thermal drifts. An in-situ calibration rig allows for steady state calibration both prior to and during thruster testing. Thrust measurements were carried out on a well-characterized 1 kW Hall thruster; the thrust stand was shown to produce repeatable results consistent with previously published performance data.

Markusic, T. E.

Increasing Density and Reducing Costs of Data Acquisition

There are a number of reasons why it is important to increase the density of data acquisition functions. Sensor fusion seeks to integrate large numbers of sensors into a decision network. Addition of health monitoring functions may incur additional sensor requirements. But at the same time, it is important to reduce the per-channel costs of data acquisition systems. Often the most significant cost is the management of data acquisition networks, which incurs substantial costs associated with transducer installation, configuration, calibration, and maintenance. Alternatives that lower the cost of the transducer system and reduce the data acquisition system channel count will directly impact initial system costs. Other techniques that affect maintenance and operating costs will contribute to reducing life cycle costs. This paper describes work undertaken to explore alternative architectures for lowering the cost per transducer function using a MEMS-based accelerometer as the model.

Schmalzel, J. L.

Precision Closed-Loop Orbital Maneuvering System Design and Performance for the Magnetospheric Multiscale Formation

NASAs Magnetospheric Multiscale (MMS) mission successfully launched on March 13,2015 (UTC) consists of four identically instrumented spin-stabilized observatories that function as a constellation to study magnetic reconnection in space. The need to maintain sufficiently accurate spatial and temporal formation resolution of the observatories must be balanced against the logistical constraints of executing overly-frequent maneuvers on a small fleet of spacecraft. These two considerations make for an extremely challenging maneuver design problem. This paper focuses on the design elements of a 6-DOF spacecraft attitude control and maneuvering system capable of delivering the high-precision adjustments required by the constellation designers specifically, the design, implementation, and on-orbit performance of the closed-loop formation-class maneuvers that include initialization, maintenance, and re-sizing. The maneuvering control system flown on MMS utilizes a micro-gravity resolution accelerometer sampled at a high rate in order to achieve closed-loop velocity tracking of an inertial target with arc-minute directional and millimeter-per second magnitude accuracy. This paper summarizes the techniques used for correcting bias drift, sensor-head offsets, and centripetal aliasing in the acceleration measurements. It also discusses the on-board pre-maneuver calibration and compensation algorithms as well as the implementation of the post-maneuver attitude adjustments.

Maneuver and Attitude Dynamics

Precision Closed-Loop Orbital Maneuvering System Design and Performance for the Magnetospheric Multi-Scale Mission (MMS) Formation

NASA's Magnetospheric Multi-Scale (MMS) mission successfully launched on March 13, 2015 (UTC) consists of four identically instrumented spin-stabilized observatories that function as a constellation to study magnetic reconnection in space. The need to maintain sufficiently accurate spatial and temporal formation resolution of the observatories must be balanced against the logistical constraints of executing overly-frequent maneuvers on a small fleet of spacecraft. These two considerations make for an extremely challenging maneuver design problem. This paper focuses on the design elements of a 6-DOF spacecraft attitude control and maneuvering system capable of delivering the high-precision adjustments required by the constellation designers---specifically, the design, implementation, and on-orbit performance of the closed-loop formation-class maneuvers that include initialization, maintenance, and re-sizing. The maneuvering control system flown on MMS utilizes a micro-gravity resolution accelerometer sampled at a high rate in order to achieve closed-loop velocity tracking of an inertial target with arc-minute directional and millimeter-per-second magnitude accuracy. This paper summarizes the techniques used for correcting bias drift, sensor-head offsets, and centripetal aliasing in the acceleration measurements. It also discusses the on-board pre-maneuver calibration and compensation algorithms as well as the implementation of the post-maneuver attitude adjustments.

Determination and Control

Cryogenic Angle Measurement at NASA Langley

NASA’s National Transonic Facility is one of the few cryogenic wind-tunnel facilities in the world, where tunnel conditions may reach -250 F. Model angle of attack (AoA) at NTF is typically measured by an on-board accelerometer package that is exposed to the cryogenic tunnel conditions. These NTF AoA packages house two Q-Flex accelerometers in a compact heated environment in order to maintain constant temperature of the sensors for stability. Recently, drift in sensor output was observed in one of the NTF AoA packages. The drift is correlated with the AoA package temperature and cryogenic soak time. This paper studies the temperature and time dependent behavior of the NTF AoA packages, and reviews their design and calibration. Recommended improvements to the AoA packages are made to improve the stability of the model angle of attack measurements at cryogenic conditions.

Toro, Kenneth G.

Developing a self-diagnostic system for piezoelectric sensors

Measurement techniques for developing a self-diagnostic system for piezoelectric sensors are presented. The self-diagnostic system uses two types of measurement techniques based on passive and active evaluation of the piezoelectric element. Both hard and soft failures can be detected by this system. Hard failures such as loss of sensor signal and change in sensor output resistance are determined by monitoring the sensor's output resistance, voltage or current. These are passive measurements of the sensor's output condition. Soft failures include changes in sensor calibration and mounting conditions. Soft failures are detected by measuring structural/electrical impedance of the piezoelectric sensor. Active measurement techniques are used to calculate changes in piezoelectric element properties related to soft failures. This paper describes the general operating principles of a self-diagnostic system and discusses the design of an active/passive measurement technique required for this system to function. Experimental results using two types of piezoelectric accelerometers are presented.

Flanagan, Patrick M.