At least 109 records · Page 6

Ferroelectric Fluid Flow Control Valve

An active valve is controlled and driven by external electrical actuation of a ferroelectric actuator to provide for improved passage of the fluid during certain time periods and to provide positive closure of the valve during other time periods. The valve provides improved passage in the direction of flow and positive closure in the direction against the flow. The actuator is a dome shaped internally prestressed ferroelectric actuator having a curvature, said dome shaped actuator having a rim and an apex. and a dome height measured from a plane through said rim said apex that varies with an electric voltage applied between an inside and an outside surface of said dome shaped actuator.

Jalink, Antony, Jr.↗

Individual Susceptibility to Hypobaric Environments: An Update

Astronauts are at risk for developing decompression sickness (DCS) while exposed to the hypobaric environment of the extravehicular suit in space, in terrestrial hypobaric chambers, and during ascent from neutral buoyancy training dives. There is increasing recognition that DCS risk is different between diving and altitude exposures, with many individual parameters and environmental factors implicated as risk factors for development of DCS in divers but are not recognized as risk factors in altitude exposures. Much of the literature to date has focused on patent foramen ovale (PFO), which has long been considered a major risk factor for DCS in diving exposures, but its link to serious DCS in altitude exposures remains unclear. Knowledge of those risk factors specific to hypobaric DCS may help identify susceptible individuals and aid in astronaut selection, crew assignment, and mission planning. This paper reviews the current literature pertaining to these risk factors, including PFO, anthropometric parameters, gender, menstrual cycle, lifetime diving experience, physical fitness, biochemical levels, complement activation, cigarette smoking, fluid balance, and ambient temperature. Further research to evaluate pertinent risk factors for DCS in altitude exposures is recommended.

Law, Jennifer↗

Geoscience Laser Altimetry System (GLAS) Loop Heat Pipe Anomaly and On Orbit Testing

The Geoscience Laser Altimetry System (GLAS) is the sole instrument on the ICESat Satellite. On day 230 of 2003, the GLAS Component Loop Heat Pipe (CLHP) entered a slow circulation mode that resulted in the main electronics box reaching its hot safing temperature, after which the entire instrument was turned off. The CLHP had a propylene working fluid and was actively temperature controlled via a heater on the compensation chamber. The slow circulation mode happened right after a planned propulsive yaw maneuver with the spacecraft. It took several days to recover the CLHP and ensure that it was still operational. The recovery occurred after the entire instrument was cooled to survival temperatures and the CLHP compensation chamber cycled on a survival heater. There are several theories as to why this slow circulation mode exhibited itself, including: accumulation of Non-Condensible Gas (NCG), the secondary wick being under designed or improperly implemented, or an expanded (post-launch) leak across the primary wick. Each of these is discussed in turn, and the secondary wick performance is identified as the most likely source of the anomalous behavior. After the anomaly, the CLHP was controlled to colder temperatures to improve its performance (as the surface tension increases with lower temperature, as does the volume of liquid in the compensation chamber) and only precursor pulses occurred later in the mission. After GLAS s last laser failed, in late 2009, a decision was made to conduct engineering tests of both LHPs to try and duplicate this flight anomaly. The engineering tests consisted of control setpoint changes, sink changes, and one similar propulsive Yaw maneuver. The only test that showed any similar anomaly precursors on the CLHP was the propulsive maneuver followed by a setpoint increase. The ICESat Satellite was placed in a decaying orbit and ended its mission on August 30, 2010 in Barents Sea.

Baker, Charles↗

Passive Stabilization of Rotating Spacecraft Using Dynamic Fluid-Pressure Equilibrium

Rotating spacecraft can provide artificial gravity for long-term space missions, but the design of a Guidance and Control scheme for these vehicles is nuanced. For a three-segment vehicle with the propulsion element located at the center of mass, the vehicle must stabilize itself about this point even in the event of various off-nominal circumstances. Thus, a robust and passive spin stabilization system is needed. In this paper, the dynamics of this system are explored and constraints are placed on the performance and controllability. A controller is thus developed based on assumptions regarding the fluid transfer between elements, and the result is simulated. Generalized methodology is then extracted and extended applications are explored, such as a conceptual fluid ring and active mass displacement for attitude control.

Rotating↗

Fluidic Fence Flow Control on A 30° Swept Wing in Compressible Freestreams

A 30° swept wing with a NACA 64(3)-618 airfoil cross-section was evaluated in four different freestream conditions with Mach numbers increasing from 0.05 to 0.7 using computational fluid dynamics simulations. Active flow control (AFC) through a streamwise row of vortex generating jets was applied at 70% span, blowing inboard to obstruct the development of spanwise flow and increase lift outboard of the control location. The effectiveness of the AFC was evaluated at α = 5° and 10° as freestream Mach number increased and the AFC mass flow coefficient was held constant. Increases to lift coefficient were reduced at higher Mach numbers, but the ratio of change in lift coefficient and the AFC momentum coefficient remained roughly constant. The fluidic fence caused decreased pressure coefficients on the outboard wing sections, but this region of decreased pressure coefficient moved aft on the chord with increasing Mach number. Mach 0.7 is higher than the critical Mach number of the wing and produced interesting interplay with the AFC, as the suction surface shock moved forward on the inboard wing section but moved aft on the outboard wing section.

Evan J McFadden↗

Fluidic Fence Flow Control on A 30° Swept Wing in Compressible Freestreams

A 30° swept wing with a NACA 64(3)-618 airfoil cross-section was evaluated in four different freestream conditions with Mach numbers increasing from 0.05 to 0.7 using computational fluid dynamics simulations. Active flow control (AFC) through a streamwise row of vortex generating jets was applied at 70% span, blowing inboard to obstruct the development of spanwise flow and increase lift outboard of the control location. The effectiveness of the AFC was evaluated at α = 5° and 10° as freestream Mach number increased and the AFC mass flow coefficient was held constant. Increases to lift coefficient were reduced at higher Mach numbers, but the ratio of change in lift coefficient and the AFC momentum coefficient remained roughly constant. The fluidic fence caused decreased pressure coefficients on the outboard wing sections, but this region of decreased pressure coefficient moved aft on the chord with increasing Mach number. Mach 0.7 is higher than the critical Mach number of the wing and produced interesting interplay with the AFC, as the suction surface shock moved forward on the inboard wing section but moved aft on the outboard wing section.

Evan J McFadden↗

Enclosure for thermoelectric refrigerator and method

An enclosed structure is provided for use with a refrigerator having a door assembly. The enclosed structure preferably contains superinsulation materials and a plurality of matching drawers. The enclosed structure preferably includes corner joints which minimize thermal energy transfer between adjacent superinsulation panels. The refrigerator may include a cooling system having a thermoelectric device for maintaining the temperature within the refrigerator at selected values. If desired, a fluid cooling system and an active gasket may also be provided between the door assembly and the enclosed structure. The fluid cooling system preferably includes a second thermoelectric device to maintain the temperature of fluid flowing through the active gasket at a selected value. The drawers associated with the refrigerator may be used for gathering, processing, shipping and storing food or other perishable items.

Park, Brian V.↗

P and W Cryogenic Fluid-Film Bearing and Seal Technology Development and Implementation

This presentation will summarize Pratt & Whitney's past, present, and future activities toward cryogenic fluid-film bearing and seal technology development and implementation. The three major areas of focus for this technology are analytical models and design tools, component testing, and technology implementation. The analytical models and design tools area will include a summary of current tools along with an overview of P&W's new full 3-D Navier-Stokes solution for hydrostatic bearings, HYDROB3D. P&W's comprehensive component test program, including teaming with the Air Force Phillips Laboratory, NASA's Marshall Space Flight Center, and Carrier Corporation, will be outlined. Component test programs consisting of material development and testing, surface patterns/roughness, pocket and orifice geometry variations, and static and dynamic performance of both journal and thrust bearings will be summarized. Finally, the technology implementation area will show the benefits and plans for P&W to incorporate this technology into products.

Pelfrey, Philip C.↗

Activated-Carbon Sorbent With Integral Heat-Transfer Device

Prototype adsorption device used, for example, in adsorption heat pump, to store natural gas to power automobile, or to separate components of fluid mixtures. Device includes activated carbon held together by binder and molded into finned heat-transfer device providing rapid heating or cooling to enable rapid adsorption or desorption of fluids. Concepts of design and fabrication of device equally valid for such other highly thermally conductive devices as copper-finned tubes, and for such other high-surface-area sorbents as zeolites or silicates.

Jones, Jack A.↗

Fractional watt Vuillemier cryogenic refrigerator program engineering notebook. Volume 1: Thermal analysis

The cryogenic refrigerator thermal design calculations establish design approach and basic sizing of the machine's elements. After the basic design is defined, effort concentrates on matching the thermodynamic design with that of the heat transfer devices (heat exchangers and regenerators). Typically, the heat transfer device configurations and volumes are adjusted to improve their heat transfer and pressure drop characteristics. These adjustments imply that changes be made to the active displaced volumes, compensating for the influence of the heat transfer devices on the thermodynamic processes of the working fluid. Then, once the active volumes are changed, the heat transfer devices require adjustment to account for the variations in flows, pressure levels, and heat loads. This iterative process is continued until the thermodynamic cycle parameters match the design of the heat transfer devices. By examing several matched designs, a near-optimum refrigerator is selected.

Miller, W. S.↗

The metabolic and hemodynamic effects of prolonged bed rest in normal subjects

Investigation in six normal subjects of the effects of chronic bed rest on the interrelationships between cardiovascular hemodynamics, catecholamine metabolism, vascular reactivity, renin and aldosterone activity, and electrolyte and fluid balance. Negative sodium and potassium balances and reductions in plasma volume were observed in all subjects, but plasma renin activity and aldosterone secretory rate showed no significant change. Other findings included the observation that major decreases in sodium balance and plasma volume occurred in the early bed rest period and did not correlate closely with the degree of orthostatic intolerance.

Chobanian, A. V.↗

Generalized Fluid System Simulation Program

A general purpose program implemented on a computer analyzes steady state and transient flow in a complex fluid network, modeling phase changes, compressibility, mixture thermodynamics and external body forces such as gravity and centrifugal force. A preprocessor provides for the inter- active development of a fluid network simulation having nodes and branches. Mass, energy, and specie conservation equations are solved at the nodes, and momentum conservation equations are solved in the branches. Contained herein are subroutines for computing "real fluid" thermodynamic and thermophysical properties for 12 fluids, and a number of different source options are provided for model- ing momentum sources or sinks in the branches. The system of equations describing the fluid network is solved by a hybrid numerical method that is a combination of the Newton-Raphson and successive substitution methods. Application and verification of this invention are provided through an example problem, which demonstrates that the predictions of the present invention compare most reasonably with test data.

Alok Kumar Majumdar↗

Using second-sound shock waves to probe the intrinsic critical velocity of liquid helium II

A critical velocity truly intrinsic to liquid helium II is experimentally sought in the bulk fluid far from the apparatus walls. Termed the 'fundamental critical velocity,' it necessarily is caused by mutual interactions which operate between the two fluid components and which are activated at large relative velocities. It is argued that flow induced by second-sound shock waves provides the ideal means by which to activate and isolate the fundamental critical velocity from other extraneous fluid-wall interactions. Experimentally it is found that large-amplitude second-sound shock waves initiate a breakdown in the superfluidity of helium II, which is dramatically manifested as a limit to the maximum attainable shock strength. This breakdown is shown to be caused by a fundamental critical velocity. Secondary effects include boiling for ambient pressures near the saturated vapor pressure or the formation of helium I boundary layers at higher ambient pressures. When compared to the intrinsic critical velocity discovered in highly restricted geometries, the shock-induced critical velocity displays a similar temperature dependence and is the same order of magnitude.

Turner, T. N.↗

Status of NASA. Marshall Space Flight Center CFD application and validation activities

NASA Marshall Space Flight Center personnel presented a paper on the status of MSFC computational fluid dynamics application and validation activities. Subjects discussed included the Space Shuttle Main Engine studies, unsteady multistage turbine loads, fuel pump discharge volutes, and injector LOX inlet results based on fundamental flows, subcomponents, and interactive components/systems.

Schutzenhofer, L. A.↗

Mapping by VESGEN of Blood Vessels in the Retinas of Astronauts Pre- and Post-Flight to the ISS

Research by NASA [1] established that significant risks for visual and ocular impairments associated with increased intracranial pressure (VIIP) are incurred by microgravity spaceflight, especially long-duration missions. It is well established in physiology and pathology that a fundamental role of the microvasculature is to mediate fluid transfers and remodel actively in response to environmental, immune and other stresses. We therefore hypothesize that remodeling of retinal blood vessels necessarily occurs during accommodation of microgravity-induced fluid shifts prior to subsequent development of visual and ocular impairments. Potential contributions of retinal vascular remodeling to VIIP etiology are therefore being investigated by NASA's innovative VESsel GENeration Analysis (VESGEN) software for two studies: (1) U.S. crew members before and after ISS missions, and (2) head-down tilt in human subjects before and after 70 days of bed rest. We anticipate that results of the two studies will be complete by the Investigators Workshop (January 22, 2017). METHODS: For the 2013 NASA NRA award, we are concluding the analysis of 30 degree infrared (IR) Heidelberg Spectralis images of retinal blood vessels by VESGEN (patents pending), a mature, automated software developed as a translational and basic vascular research discovery tool, particularly for retinal vascular disease. Subjects of our retrospective study include eight ISS crew members monitored for routine occupational surveillance pre- and post-flight, who provided their study consents to NASAs Lifetime Surveillance of Astronaut Health (LSAH) in coordination with approval of the VESGEN retrospective study protocol by NASAs Institutional Review Board (IRB). The ophthalmic retinal images (average image resolution, approximately 5.6 microns per pixel) are blinded as to pre and post ISS status until the second portion of our study, when VESGEN results will be correlated with other ophthalmic and medical findings for the crew members. Due to image resolution challenges, a novel Matlab tool was developed for aligning pre and post images, and comparing (querying) the two images for differences in the morphology of small vessels. RESULTS: During the past year, LSAH approved the release of all astronaut retinal images to our study for VESGEN analysis. Substantial progress on the initial blinded portion of the study is in place. We anticipate that VESGEN analysis of the 32 Spectralis IR retinal images will be complete for presentation at the 2017 IWS meeting. CONCLUSIONS: Modified retinal vascular patterning may offer early-stage predictions of ocular changes resulting in decreased visual acuity for the VIIP syndrome. Novel insights provided by VESGEN into progressively pathological and blinding vascular remodeling in the human retina currently help to guide other NIH- and NASA-supported therapeutic studies of retinal disease and modeling of the VIIP risk. Results of our vascular investigation of the retinas of astronauts pre- and post-flight may help advance the understanding of both healthy and pathological adaptations to fluid shifts in microgravity associated with the VIIP syndrome. Preliminary results indicate that imaging of higher resolution, such as the new OCT angiography (OCT-A) technology, will be required to determine conclusively the role of the smaller retinal and choroidal vessels in VIIP etiology.

VESGEN↗

Pratt and Whitney Activities

An example of Computational Fluid Dynamics (CFD) application in the seal area is described. This effort consisted of optimizing specific seals in the Space Shuttle Main Engine Alternate Turbopump Development (SSME ATD) and resulted in design of a seal tested which demonstrated 30 percent lower leakage than the standard design at the same clearance. This example shows the potential of identifying seal geometry parameters which reduce internal flow leakages detrimental to component and turbopump efficiencies. This information can than be used to develop an analytical design procedure for controlling leakage in any given application or environment.

Syed, Saadat A.↗

Organic-rich fluids in Pluto’s interior—A source of cryovolcanic activity

The highly variegated surface of Pluto revealed by the New Horizons spacecraft is composed of both volatile ices (N2, CH4, CO) and H2O ice, all of which are intrinsically colorless. The colors on Pluto reveal a non-ice component generally acknowledged to be a refractory complex organic material (tholins) produced by photolysis in the planet’s atmosphere [1], and by photolysis and radiolysis of the surface ices [2-4]. These processes have produced a range of colors from pale yellow to red to brown, and result in a variation of a factor of 10in albedo across the surface. Tholins are disordered polymer-like materials made of repeating chains of linked subunits and complex combinations of functional groups containing carbon. Nitrogen, oxygen, and other elements can be substituted in both the aliphatic and aromatic subunits. The detection of the spectral absorption of an ammoniated compound associated with surface exposures of red-colored H2O ice (herein, RAW) in the LEISA spectral mapping data from New Horizons suggests that a third source of a colored material is ejected from Pluto’s interior as a water-rich fluid(cryomagma) that rapidly freezes at the low temperature (~40K) of the surface [5,6]. The ammoniated compound is thought to be an ammonia hydrate or an ammoniated salt; the spectral data cover a limited wavelength range, resulting in ambiguity in the identification of the form of the ammonia. The distribution of RAW in the vicinity of tectonically stressed and deformed geological structures, particularly graben (fossae), is seen as the result of both fluid effusion and fountaining ejection of cryoclastic materials in Pluto’s Virgil Fossae region [5,6]. RAW is seen elsewhere on Pluto, both in association with graben complexes and on broad expanses of old surface, but primarily in zones of tectonic stress. The nature of the putative subsurface fluid is unknown, but it must have existed at relatively shallow depths such that the graben faulting could reach it. Geochemical modeling of fluids in the interiors of small planetary bodies in the outer Solar System[7] shows that ammonia-bearing H2O in contact with rock and metal components produce a rich chemical soup, including gases that can, in principle, help propel the fluid from shallow reservoirs through crustal fractures to reach the surface. An organic component of the fluid cryomagma is predicted to originate from thermal processing of the components [ref] and may be an example of one-pot synthesis of such complexes as amino acid precursors [ref].

Dale P Cruikshank↗