Search NASA⌕ Search

SEARCH · Search NASA

Results for “active pixel sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 109 records · Page 6

The Terra Vega Active Light Source: A First Step in a New Approach to Perform Nighttime Absolute Radiometric Calibrations and Early Results Calibrating the VIIRS DNB

A fully automated, National Institute of Standards and Technology (NIST)-traceable artificial light source called Terra Vega has been developed to radiometrically calibrate the Visible Infrared Imaging Radiometer (VIIRS) Day Night Band (DNB) working in high gain stage (HGS) mode. The Terra Vega active point source is a calibrated integrating sphere that is only a fraction in size of a VIIRS DNB pixel. As such, it can be considered analogous to a ground-based photometric reference star. Vicarious calibrations that employ active point sources are different than those that make use of traditional extended sources and can be applyed to quantify the brightness of artificial light sources. The active source is successfully fielded, and early results indicate that it can be used to augment and validate the radiometric calibration of the VIIRS DNB HGS sensor on both the Suomi National Polar-orbiting Partnership (NPP) and NOAA-20 satellites. The VIIRS DNB HGS sensor can benefit from this technology as on-board calibration is challenging and hinges on transferring low gain stage (LGS) calibration using a solar diffuser to the medium gain stage (MGS) and HGS via regions of overlap. Current vicarious calibration methods that use a lunar-illuminated extended source estimate the HGS radiometric accuracy to within 8-15%. By comparison, early results and analysis showed that Terra Vega is stable to about 1%. Under clear dark night conditions, predicted top-of-atmosphere radiance from Terra Vega ranged between 1–11% of VIIRS measured values. Terra Vega’s excellent stability opens up new opportunities to validate and develop nighttime imaging applications based on point sources.

Ryan, Robert↗

Design of an ultra low power CMOS pixel sensor for a future neutron personal dosimeter

Despite a continuously increasing demand, neutron electronic personal dosimeters (EPDs) are still far from being completely established because their development is a very difficult task. A low-noise, ultra low power consumption CMOS pixel sensor for a future neutron personal dosimeter has been implemented in a 0.35 {mu}m CMOS technology. The prototype is composed of a pixel array for detection of charged particles, and the readout electronics is integrated on the same substrate for signal processing. The excess electrons generated by an impinging particle are collected by the pixel array. The charge collection time and the efficiency are the crucial points of a CMOS detector. The 3-D device simulations using the commercially available Synopsys-SENTAURUS package address the detailed charge collection process. Within a time of 1.9 {mu}s, about 59% electrons created by the impact particle are collected in a cluster of 4 x 4 pixels with the pixel pitch of 80 {mu}m. A charge sensitive preamplifier (CSA) and a shaper are employed in the frond-end readout. The tests with electrical signals indicate that our prototype with a total active area of 2.56 x 2.56 mm{sup 2} performs an equivalent noise charge (ENC) of less than 400 e - and 314 {mu}W power consumption, leading to a promising prototype. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

HRPPD photosensors for RICH detectors with a high resolution timing capability

Recently, a new version of DC-coupled High Rate Picosecond Photodetectors (DC-HRPPDs) substantially re-designed for use at the Electron-Ion Collider (EIC) has been developed. A first batch of seven “EIC HRPPDs” was manufactured in early 2024. These HRPPDs are DC-coupled photosensors based on Micro-Channel Plates (MCPs) that have an active area of 104 mm by 104 mm, 32 × 32 direct readout pixel array at a pitch of 3.25 mm, peak quantum efficiency in excess of 30%, exceptionally low dark count rates and timing resolution of 15–20 ps for a single photon detection. As such, these photosensors are very well suited for Ring Imaging CHerenkov (RICH) detectors that can additionally provide high resolution timing capability, especially in a configuration where a detected charged particle passes through the sensor window, which produces a localized flash containing a few dozens of Cherenkov photons in it.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Module Testing Procedures and Results for the CMS Phase-2 Outer Tracker Upgrade at Fermilab

The High-Luminosity LHC (HL-LHC) will operate at significantly increased luminosities and is expected to deliver about 3000 $fb^{-1}$ of proton-proton collision data at $\sqrt{s}=14$ TeV over a decade of operation. To maintain efficient tracking and triggering performance under high pileup and radiation conditions, the CMS experiment is upgrading its tracking detector for Phase-2 operations. The upgraded Outer Tracker (OT) will consist of Pixel-Strip (PS) and Strip-Strip (2S) silicon modules capable of providing tracking information to the Level-1 trigger at 40 MHz. Production and qualification of OT modules have been ongoing for about one year across several assembly and testing centers in the US, Europe, India, and Pakistan, requiring extensive testing to ensure stable operation in the HL-LHC environment. Fermilab is responsible for the production and testing of a significant fraction of the OT modules. The testing activities include IV characterization of silicon sensors, noise and pedestal measurements, verification of communication between module components, and burn-in studies using cold-box systems operated under controlled thermal conditions. Results from module testing and qualification studies performed during production will be presented.

Baradia, Sweta [UC, Davis (main)]↗

a-Si:H TFT-silicon hybrid low-energy x-ray detector

Direct conversion crystalline silicon X-ray imagers are used for low-energy X-ray photon (4-20 keV) detection in scientific research applications such as protein crystallography. In this paper, we demonstrate a novel pixel architecture that integrates a crystalline silicon X-ray detector with a thin-film transistor amorphous silicon pixel readout circuit. We describe a simplified two-mask process to fabricate a complete imaging array and present preliminary results that show the fabricated pixel to be sensitive to 5.89-keV photons from a low activity Fe-55 gamma source. Furthermore, this paper presented can expedite the development of high spatial resolution, low cost, direct conversion imagers for X-ray diffraction and crystallography applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real World Use Case Evaluation of Radar Retro-reflectors for Autonomous Vehicle Lane Detection Applications

Lane detection plays a critical role in autonomous vehicles for safe and reliable navigation. Lane detection is traditionally accomplished using a camera sensor and computer vision processing. The downside of this traditional technique is that it can be computationally intensive when high quality images at a fast frame rate are used and has reliability issues from occlusion such as, glare, shadows, active road construction, and more. This study addresses these issues by exploring alternative methods for lane detection in specific scenarios caused from road construction-induced lane shift and sun glare. Specifically, a U-Net, a convolutional network used for image segmentation, camera-based lane detection method is compared with a radar-based approach using a new type of sensor previously unused in the autonomous vehicle space: radar retro-reflectors. This evaluation is performed using ground truth data, obtained by measuring the lane positions and transforming them into pixel coordinates. The performance of each method is assessed using the statistical R2 score, indicating the correlation between the detected lane lines and the ground truth. The results show that the U-Net camera-based method exhibits limitations in accurately detecting and aligning the lane lines, particularly in challenging scenarios. However, the radar-based lane detection method demonstrates a strong correlation with the ground truth which implies that the use of this sensor may improve current reliability issues from conventional camera lane detection approach. Furthermore, the study highlights the limitations of the U-Net model for camera lane detection, especially in scenarios with sun glare. This study shows that infrastructure-based radar retro-reflectors can improve autonomous vehicle lane detection reliability. The integration of different sensor modalities and the development of advanced computer vision algorithms are crucial for improving the accuracy, reliability, and energy efficiency of lane detection systems. Addressing these challenges contributes to the advancement of autonomous vehicles and the realization of safer and more efficient transportation systems.

Brown, Nicolas E.↗

X-Ray Imaging and Spectroscopy Mission

The X-Ray Imaging and Spectroscopy Mission (XRISM) is a joint mission between the Japan Aerospace Exploration Agency (JAXA) and the National Aeronautics and Space Administration (NASA) in collaboration with the European Space Agency (ESA). In addition to the three space agencies, universities and research institutes from Japan, North America, and Europe have joined to contribute to developing satellite and onboard instruments, data-processing software, and the scientific observation program. XRISM is the successor to the ASTRO-H (Hitomi) mission, which ended prematurely in 2016. Its primary science goal is to examine astrophysical problems with precise, high-resolution X-ray spectroscopy. XRISM promises to discover new horizons in X-ray astronomy. It carries a 6 × 6 pixelized X-ray microcalorimeter on the focal plane of an X-ray mirror assembly (Resolve) and a co-aligned X-ray CCD camera (Xtend) that covers the same energy band over a large field of view. XRISM utilizes the Hitomi heritage, but all designs were reviewed. The attitude and orbit control system was improved in hardware and software. The spacecraft was launched from the JAXA Tanegashima Space Center on 2023 September 6 (UTC). During the in-orbit commissioning phase, the onboard components were activated. Although the gate valve protecting the Resolve sensor with a thin beryllium X-ray entrance window was not yet opened, scientific observation started in 2024 February with the planned performance verification observation program. The nominal observation program commenced with the following guest observation program beginning in 2024 September.

Astronomy and AstroPhysics↗

The Illumination of Thunderclouds by Lightning: 1. The Extent and Altitude of Optical Lightning Sources

Abstract Optical space‐based lightning sensors including NOAA's Geostationary Lightning Mapper (GLM) detect lightning though its transient illumination of the surrounding clouds. What space‐based optical lightning sensors measure is influenced by the physical attributes of the light source, the location of the source within the cloud scene, and the spatial variations in cloud composition. We focus on the lightning channels that serve as optical sources for GLM groups and flashes in this first part of our thundercloud illumination study. We match Lightning Mapping Array (LMA) sources with GLM groups and flashes during two thunderstorms to examine channel segments that are active during optical emission. We find that in each storm, the LMA sources matched with GLM groups are small (median: 3 km) compared to GLM pixels (nominal: 8 km), and preferentially come from high altitudes in the cloud (>8–10 km). The detection advantage for high‐altitude sources permits GLM to resolve faint optical pulses near the cloud top that might be missed from lower altitudes. However, the most energetic groups can be detected from all altitudes, and the largest groups largely originate at low altitudes. The relationship between group energy and illuminated area depends on flash development within the cloud medium, and flash development into different cloud regions can be identified by tracking GLM metrics of cloud illumination over time.

58 GEOSCIENCES↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 $\mu$m$^2$ in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e$^-$ and a total dispersion of $\sim$100e$^-$ The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4% - 75.4% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm$^2$ staying within the experimental constraints.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Smart Pixels: In-pixel AI for on-sensor data filtering

We present a smart pixel prototype readout integrated circuit (ROIC) designed in CMOS 28 nm bulk process, with in-pixel implementation of an artificial intelligence (AI) / machine learning (ML) based data filtering algorithm designed as proof-of-principle for a Phase III upgrade at the Large Hadron Collider (LHC) pixel detector. The first version of the ROIC consists of two matrices of 256 smart pixels, each 25$\times$25 µm\textsuperscript{2} in size. Each pixel consists of a charge-sensitive preamplifier with leakage current compensation and three auto-zero comparators for a 2-bit flash-type ADC. The frontend is capable of synchronously digitizing the sensor charge within 25 ns. Measurement results show an equivalent noise charge (ENC) of $\sim$30e\textsuperscript{-} and a total dispersion of $\sim$100e\textsuperscript{-} The second version of the ROIC uses a fully connected two-layer neural network (NN) to process information from a cluster of 256 pixels to determine if the pattern corresponds to highly desirable high-momentum particle tracks for selection and readout. The digital NN is embedded in-between analog signal processing regions of the 256 pixels without increasing the pixel size and is implemented as fully combinatorial digital logic to minimize power consumption and eliminate clock distribution, and is active only in the presence of an input signal. The total power consumption of the neural network is $\sim$ 300 $\mu$W. The NN performs momentum classification based on the generated cluster patterns and even with a modest momentum threshold, it is capable of 54.4\% – 75.4\% total data rejection, opening the possibility of using the pixel information at 40MHz for the trigger. The total power consumption of analog and digital functions per pixel is $\sim$ 6 $\mu$W per pixel, which corresponds to $\sim$ 1 W/cm\textsuperscript{2} staying within the experimental constraints.

Parpillon, Benjamin↗

A laser powder bed fusion system for operando synchrotron x-ray imaging and correlative diagnostic experiments at the Stanford Synchrotron Radiation Lightsource

Laser powder bed fusion (LPBF) is a highly dynamic multi-physics process used for the additive manufacturing (AM) of metal components. Improving process understanding and validating predictive computational models require high-fidelity diagnostics capable of capturing data in challenging environments. Synchrotron x-ray techniques play a vital role in the validation process as they are the only in situ diagnostic capable of imaging sub-surface melt pool dynamics and microstructure evolution during LPBF-AM. In this article, a laboratory scale system designed to mimic LPBF process conditions while operating at a synchrotron facility is described. The system is implemented with process accurate atmospheric conditions, including an air knife for active vapor plume removal. Significantly, the chamber also incorporates a diagnostic sensor suite that monitors emitted optical, acoustic, and electronic signals during laser processing with coincident x-ray imaging. The addition of the sensor suite enables validation of these industrially compatible single point sensors by detecting pore formation and spatter events and directly correlating the events with changes in the detected signal. Experiments in the Ti–6Al–4V alloy performed at the Stanford Synchrotron Radiation Lightsource using the system are detailed with sufficient sampling rates to probe melt pool dynamics. X-ray imaging captures melt pool dynamics at frame rates of 20 kHz with a 2 µm pixel resolution, and the coincident diagnostic sensor data are recorded at 470 kHz. Furthermore, this work shows that the current system enables the in situ detection of defects during the LPBF process and permits direct correlation of diagnostic signatures at the exact time of defect formation.

36 MATERIALS SCIENCE↗

Design methodology: edgeless 3D ASICs with complex in-pixel processing for pixel detectors

The design methodology for the development of 3D integrated edgeless pixel detectors with in-pixel processing using Electronic Design Automation (EDA) tools is presented. A large area 3 tier 3D detector with one sensor layer and two ASIC layers containing one analog and one digital tier, is built for x-ray photon time of arrival measurement and imaging. A full custom analog pixel is 65μm x 65μm. It is connected to a sensor pixel of the same size on one side, and on the other side it has approximately 40 connections to the digital pixel. A 32 x 32 edgeless array without any peripheral functional blocks constitutes a sub-chip. The sub-chip is an indivisible unit, which is further arranged in a 6 x 6 array to create the entire 1.248cm x 1.248cm ASIC. Each chip has 720 bump-bond I/O connections, on the back of the digital tier to the ceramic PCB. All the analog tier power and biasing is conveyed through the digital tier from the PCB. The assembly has no peripheral functional blocks, and hence the active area extends to the edge of the detector. This was achieved by using a few flavors of almost identical analog pixels (minimal variation in layout) to allow for peripheral biasing blocks to be placed within pixels. The 1024 pixels within a digital sub-chip array have a variety of full custom, semi-custom and automated timing driven functional blocks placed together. The methodology uses a modified mixed-mode on-top digital implementation flow to not only harness the tool efficiency for timing and floor-planning but also to maintain designer control over compact parasitically aware layout. The methodology uses the Cadence design platform, however it is not limited to this tool.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BrachyView, A novel inbody imaging system for HDR prostate brachytherapy: Design and Monte Carlo feasibility study

Purpose: High dose rate (HDR) brachytherapy is a form of radiation therapy for treating prostate cancer whereby a high activity radiation source is moved between predefined positions inside applicators inserted within the treatment volume. Accurate positioning of the source is essential in delivering the desired dose to the target area while avoiding radiation injury to the surrounding tissue. In this paper, HDR BrachyView, a novel inbody dosimetric imaging system for real time monitoring and verification of the radioactive seed position in HDR prostate brachytherapy treatment is introduced. The current prototype consists of a 15 Multiplication-Sign 60 mm{sup 2} silicon pixel detector with a multipinhole tungsten collimator placed 6.5 mm above the detector. Seven identical pinholes allow full imaging coverage of the entire treatment volume. The combined pinhole and pixel sensor arrangement is geometrically designed to be able to resolve the three-dimensional location of the source. The probe may be rotated to keep the whole prostate within the transverse plane. The purpose of this paper is to demonstrate the efficacy of the design through computer simulation, and to estimate the accuracy in resolving the source position (in detector plane and in 3D space) as part of the feasibility study for the BrachyView project.Methods: Monte Carlo simulations were performed using the GEANT4 radiation transport model, with a {sup 192}Ir source placed in different locations within a prostate phantom. A geometrically accurate model of the detector and collimator were constructed. Simulations were conducted with a single pinhole to evaluate the pinhole design and the signal to background ratio obtained. Second, a pair of adjacent pinholes were simulated to evaluate the error in calculated source location.Results: Simulation results show that accurate determination of the true source position is easily obtainable within the typical one second source dwell time. The maximum error in the estimated projection position was found to be 0.95 mm in the imaging (detector) plane, resulting in a maximum source positioning estimation error of 1.48 mm.Conclusions: HDR BrachyView is a feasible design for real-time source tracking in HDR prostate brachytherapy. It is capable of resolving the source position within a subsecond dwell time. In combination with anatomical information obtained from transrectal ultrasound imaging, HDR BrachyView adds a significant quality assurance capability to HDR brachytherapy treatment systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First results from a multiplexed and massive instrument with sub-electron noise Skipper-CCDs

Here, we present a new instrument composed of a large number of sub-electron noise Skipper-CCDs operated with a two stage analog multiplexed readout scheme suitable for scaling to thousands of channels. New, thick, 1.35 Mpix sensors, from a new foundry, are glued into a Multi-Chip Module (MCM) printed circuit board on a ceramic substrate which has 16 sensors each. The instrument, that can hold up-to 16 MCMs, a total of 256 Skipper-CCD sensors (called a Super-Module with ≈ 130 grams of active mass and 346 Mpix), is part of the R&D effort of the OSCURA experiment which will have ≈ 94 super-modules. Experimental results with 10 MCMs and 160 Skipper-CCDs sensors are presented in this paper. This is already the largest ever built instrument with single electron sensitivity CCDs using nondestructive readout, both, in terms of active mass and number of channels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Single-photon detection using large-scale high-temperature MgB2 sensors at 20 K

Abstract Ultra-fast single-photon detectors with high current density and operating temperature can benefit space and ground applications, including quantum optical communication systems, lightweight cryogenics for space crafts, and medical use. Here we demonstrate magnesium diboride (MgB 2 ) thin-film superconducting microwires capable of single-photon detection at 1.55 μ m optical wavelength. We used helium ions to alter the properties of MgB 2 , resulting in microwire-based detectors exhibiting single-photon sensitivity across a broad temperature range of up to 20 K, and detection efficiency saturation for 1 μ m wide microwires at 3.7 K. Linearity of detection rate vs incident power was preserved up to at least 100 Mcps. Despite the large active area of up to 400 × 400 μ m 2 , the reset time was found to be as low as ~ 1 ns. Our research provides possibilities for breaking the operating temperature limit and maximum single-pixel count rate, expanding the detector area, and raises inquiries about the fundamental mechanisms of single-photon detection in high-critical-temperature superconductors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SpaceNet 9—Cross-Sensor Alignment of Optical and SAR Imagery

Precise registration of high-resolution synthetic aperture radar (SAR) and optical imagery is necessary for realizing the full potential and benefits of multimodal image analysis. However, two significant challenges presently exist. First, there is a lack of annotated datasets and benchmarks available for high-resolution SAR–optical image registration. Second, an assessment of efficient and reliable image registration methods that can precisely align these modalities is lacking. Here, we present a holistic description of the SpaceNet 9 Challenge and its results. We present a description of the dataset and baseline algorithm along with the results of the challenge, including a description of the winning algorithms. We release the SpaceNet 9 dataset along with open-sourcing the winning algorithms and baseline. The objective of SpaceNet 9 was to compute a dense displacement map that indicates the shift needed to align pixels in an optical image to the pixels in a SAR image. The challenge launched in April 2025 and was active for approximately two months. The top five solutions reduced image alignment error from approximately 34 m to under 13 m for public and private test data, with the best results obtaining a registration error of only 8.5 and 6.7 m on the public testing and private testing dataset, respectively. Usage of pretrained image matching models, robust outlier rejection with RANSAC, and estimating local displacement were common among the top solutions. The results of this challenge provide insight into high-resolution SAR–optical image registration and offer opportunities for future benchmarking in this domain. The baseline algorithm, winning solutions, and datasets are available at https://spacenet.ai/sn9-challenge/.

benchmark datasets↗

Radiation Imaging with Event Camera

Neuromorphic or event-based imaging is a new, commercially available sensor technology inspired by how the human eye works. Instead of measuring frames at a fixed rate, the camera measures changes in pixel intensity asynchronously. This difference in readout architecture results in a high dynamic range and low latency. Event-based cameras have been used in a variety of applications, including object tracking, navigation, and lidar technologies. However, event-based cameras have not been adequately researched for their ability to image high-energy particles. This report explores the use of an event camera for imaging alpha, beta, and X-rays particles, when coupled with scintillator screens to convert high-energy particles into visible light. Methods to process event data were developed and are presented here, along with the results. The event camera can measure alpha and beta particles with comparable performance to that of a conventional camera. Event cameras can also image higher-activity sources and offer the possibility of discriminating particle interaction types on the basis of timing differences, which typical cameras cannot do. Additionally, event cameras can image objects with an X-ray source when the source strength dynamically changes but does not create a high-contrast image during static X-ray measurement.

47 OTHER INSTRUMENTATION↗