Search NASA⌕ Search

SEARCH · Search NASA

Results for “active subspaces”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

92 records · Page 6

Deformable segmentation of 3D MR prostate images via distributed discriminative dictionary and ensemble learning

Purpose: Automatic prostate segmentation from MR images is an important task in various clinical applications such as prostate cancer staging and MR-guided radiotherapy planning. However, the large appearance and shape variations of the prostate in MR images make the segmentation problem difficult to solve. Traditional Active Shape/Appearance Model (ASM/AAM) has limited accuracy on this problem, since its basic assumption, i.e., both shape and appearance of the targeted organ follow Gaussian distributions, is invalid in prostate MR images. To this end, the authors propose a sparse dictionary learning method to model the image appearance in a nonparametric fashion and further integrate the appearance model into a deformable segmentation framework for prostate MR segmentation. Methods: To drive the deformable model for prostate segmentation, the authors propose nonparametric appearance and shape models. The nonparametric appearance model is based on a novel dictionary learning method, namely distributed discriminative dictionary (DDD) learning, which is able to capture fine distinctions in image appearance. To increase the differential power of traditional dictionary-based classification methods, the authors' DDD learning approach takes three strategies. First, two dictionaries for prostate and nonprostate tissues are built, respectively, using the discriminative features obtained from minimum redundancy maximum relevance feature selection. Second, linear discriminant analysis is employed as a linear classifier to boost the optimal separation between prostate and nonprostate tissues, based on the representation residuals from sparse representation. Third, to enhance the robustness of the authors' classification method, multiple local dictionaries are learned for local regions along the prostate boundary (each with small appearance variations), instead of learning one global classifier for the entire prostate. These discriminative dictionaries are located on different patches of the prostate surface and trained to adaptively capture the appearance in different prostate zones, thus achieving better local tissue differentiation. For each local region, multiple classifiers are trained based on the randomly selected samples and finally assembled by a specific fusion method. In addition to this nonparametric appearance model, a prostate shape model is learned from the shape statistics using a novel approach, sparse shape composition, which can model nonGaussian distributions of shape variation and regularize the 3D mesh deformation by constraining it within the observed shape subspace. Results: The proposed method has been evaluated on two datasets consisting of T2-weighted MR prostate images. For the first (internal) dataset, the classification effectiveness of the authors' improved dictionary learning has been validated by comparing it with three other variants of traditional dictionary learning methods. The experimental results show that the authors' method yields a Dice Ratio of 89.1% compared to the manual segmentation, which is more accurate than the three state-of-the-art MR prostate segmentation methods under comparison. For the second dataset, the MICCAI 2012 challenge dataset, the authors' proposed method yields a Dice Ratio of 87.4%, which also achieves better segmentation accuracy than other methods under comparison. Conclusions: A new magnetic resonance image prostate segmentation method is proposed based on the combination of deformable model and dictionary learning methods, which achieves more accurate segmentation performance on prostate T2 MR images.

60 APPLIED LIFE SCIENCES↗

Analysis of seismicity at observed at station BCE using subspace detectors

A dynamic correlation processor (DCP) was used to process 90 days of 3-component seismic data recorded by station BCE. Two methods of detector creation were compared. The first attempted to span the signal space with a small number of subspace detectors having minimal projections on one another, and the second used a much larger number of detectors with substantial inter-template projections. After two passes over the data the results were compared, and the second approach was found to have produced more than 3 times the number of detections. For events in common, the average correlation statistic for the second approach was 0.77 compared to a statistic of 0.65 for the first approach. Also, analysis of the detection statistics as a function of SNR showed a strong functional relationship between SNR and correlation statistic for the second approach not found in the first approach. I interpret this to mean that the intra-group variability of signals produced by the second method is due primarily to noise rather than variations in source or path. These results show that (in an environment with large numbers of repeaters) if precise classification is a goal, it is better to operate a DCP with many correlators with substantial inter-template projections and that fully span the signal space. The performance of the DCP was also measured using a small set of “ground truth” picks for BCE from the Chip Brogan catalog. The catalog spanned less than three days out of the 90 days of the experiment and is also incomplete, but the comparison identified 12 signals missed by the DCP because of low SNR. Combining detections by the DCP and picks from the Brogan catalog, identifies 76 unique signals. Of these, the DCP detected 64 (84%) and the Catalog contained between 48/76 (63%) and 48/62 (77%). Analysis of time-of-day and day-of-week statistics was not useful in identifying the signal sources. However, magnitude recurrence statistics were consistent with mining induced seismicity (a preponderance of small sources). Failure of the temporal discriminants may indicate that the events being detected are not coupled in the same way to the mining activity, e.g. secondary failures. Correlation data from explosions at the Nevada test site (NTS) were used to bound the separation of events within groups. Nearly all the NTS correlations with the same passband and time bandwidth product as the detections and having a correlation statistic >= 0.8 are from sources separated by less than 1 km. Even at correlation values of 0.6 nearly all the source separations are less than about 3 km. Because the DCP detectors were formed to span the signal space at a correlation value of 0.9 and because the intra-group variability is most likely due to noise and not source variability, it is likely that the sources associated with each detector are separated by one km or less, and almost certain that the majority are separated by no more than 3 km.

47 OTHER INSTRUMENTATION↗